XLXiaohua Lei

Xiaohua Lei

*This is an algorithmically generated author record based on publicly available information.

Xiaohua Lei has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spontaneous rotation of a toric implantable collamer lens related to abnormal ciliary body morphology: a case report

    by Qian Chen, Qingyan Zeng, Zheng Wang, Chao Pan, Xiaohua Lei, Weina Tan

    Background: This is a case of spontaneous toric implantable collamer lens (TICL) rotation that occurred twice in the left eye of a patient. Case presentation: A 24-year-old gentleman received TICL implantation for treatment of myopic astigmatism encountered with spontaneous rotation of approximately 90° from its original position. TICL reposition procedure was performed with visual outcome of 20/16. Surprisingly, a re-rotation of TICL occurred. The patient underwent a replacement of non-toric ICL with a larger size after careful re-evaluation with final visual outcome of 20/20. A short and small ciliary process with shallow ciliary sulcus and posteriorly positioned ciliary body was found by Ultrasound Biomicroscopy (UBM). Conclusions: The unique morphology of the ciliary body may have a potential association with the vault and instability of implanted ICL. Careful examination of the ciliary body morphology is essential in preoperative evaluation.


  • Open Access

    Comprehensive evaluation of total corneal refractive power by ray tracing in predicting corneal power in eyes after small incision lenticule extraction

    by Chao Pan, Weina Tan, Yanjun Hua, Xiaohua Lei

    To assess the prediction accuracy of four variations of total corneal refractive power (TCRP) by the ray tracing method in determining corneal power in eyes after myopic small incision lenticule extraction (SMILE). Forty eyes of forty patients who had undergone myopic SMILE were enrolled in this prospective study. Manifest refraction and Pentacam HR were performed preoperatively and three months or more postoperatively. Mean keratometry (Km), true net power (TNP), equivalent keratometry readings (EKR) and 4 subtypes of TCRP (pupil centered or apex centered within a ring or a zone)—TCRPpupil,ring, TCRPpupil,zone, TCRPapex,ring and TCRPapex,zone—were recorded and compared to the theoretical postoperative keratometry value using the clinical history method (CHM). The only keratometric values that showed no statistically significant differences from the CHM were 4.0 mm and 4.5 mm EKR, 6.0 mm TCRPpupil,zone and TCRPapex,zone. Pearson’s correlation test revealed that 4.0 mm TCRPpupil,zone exhibited the highest correlation coefficient (r = 0.974) followed by TCRPapex,zone 4.0 mm (0.972) and EKR 4.5 mm (0.970). The 95% limits of agreement (LOA) of the 4.0 mm EKR and CHM, the 4.5 mm EKR and CHM, the 6.0 mm TCRPpupil,zone and CHM, the 6.0 mm TCRPapex,zone and CHM were (-1.27 to 1.22 D), (-1.04 to 0.98 D), (-1.39 to 1.08 D) and (-1.38 to 0.96 D), respectively, while the modified 4.0 mm TCRPpupil,zone (TCRPpuil,zone + 0.70 D) and TCRPapex,zone (TCRPapex,zone+0.70 D) yielded the narrowest 95% LOA of (-0.96 to 0.95 D) and (-0.96D, 1.05 D). Total corneal refractive power using the ray tracing method could predict corrected corneal power derived from the CHM in eyes following SMILE surgery after simple modification.


  • Corneal power measurement with a new aberrometer/corneal topographer in eyes after small incision lenticule extraction for myopia

    by Chao Pan, Weina Tan, Yanjun Hua, Xiaohua Lei

    To assess corneal power measurements obtained by the OPD SCAN III Topographer in eyes with prior myopic small incision lenticule extraction (SMILE) surgery.