SPSantiago Pujol

Santiago Pujol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Santiago Pujol has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Discussion of Paper by Chin, Cheng, Lepage, and Lequesne

    by Prateek Shah, Santiago Pujol, Liam Pledger, Lucas Laughery

  • Open Access

    Estimating the dynamic properties of wall-frame structures

    by Liam Pledger, Santiago Pujol, Reagan Chandramohan

    This study outlines a robust method to approximate the dynamic properties of wall-frame structures with a reasonable degree of reliability based on simple mechanics. The seismic response and drift demand of a structure are largely influenced by its first translational period and mode-shape. This study develops a method to estimate the storey stiffness of a wall, which can be combined with the storey stiffness of a frame to estimate the fundamental period and mode-shape for wall-frame structures. The fundamental period and mode-shape are calculated using this effective storey stiffness and Rayleigh’s principle. A total of 301 wall-frame structures were sized to evaluate the reliability of the proposed method. Structures ranged from 2 to 25 storeys tall. The fundamental period and mode-shape estimated using the proposed method were compared with results from eigenvalue analysis of a detailed linear structural model. The proposed method leads to approximately 4% error on average for estimating the fundamental period of regular structures. The proposed method leads to 5% error on average for irregular structures with partial height walls, as well as variations in storey height, and lateral stiffness. For regular wall-frame structures, the proposed method led to average errors of 4% when estimating the roof mode-shape factor and 2% when estimating the maximum difference in mode-shape factor from one floor to the next, a proxy for storey drift. These errors were 5% and 15% for irregular structures with partial height walls. Results were also compared with estimates obtained from existing empirical equations to approximate the period of wall-frame structures, highlighting that empirical equations lead to greater error, between 15 and 70% depending on the equation. The method outlined in this paper enables users to estimate or corroborate the fundamental period, mode-shape, and lateral displacement for a dual wall-frame structure with a reasonable degree of reliability, suitable for preliminary design and linear analysis. Tools have been developed in MathCAD and python to automate the procedure for estimating the dynamic properties of wall-frame structures and are available here.

  • Influence of prior shaking on seismic drift demands

    by Prateek Shah, Jonathan Monical, Aishwarya Puranam, Santiago Pujol, Charles Kerby

    Following the 2011 downtown Christchurch earthquake, 60% of buildings in Christchurch were demolished and reconstructed. Such practices are costly in terms of money and carbon emissions. Structures need to be proportioned so that they can be reused after one or several ground motions. To do so, it is important to understand the effect of previous shaking on drift demands. Past studies conducted to investigate the effect of previous shaking were based almost exclusively on numerical analyses that used a limited set of parameters. Conclusions from past numerical analyses do not lead to a clear consensus, and results from past studies have not been systematically vetted against measurements from structures tested in the laboratory or evidence from the field. To address these issues, the plausible effects of previous shaking on drift demands were re-evaluated using (1) numerical analyses of Single and Multi-Degree-of-Freedom oscillators with an expanded set of parameters and (2) measurements from 220 experimental tests of structures subjected to repeated simulated base motions. The compiled evidence supports at least two conclusions: (1) Repeats of medium or high-intensity motions strong enough to cause yielding in their first occurrence are unlikely to produce large relative increases in peak drift demands in structures with stable force–displacement relationships not susceptible to brittle failures. This phenomenon was observed in repeated motions not preceded by more intense motions, as well as in repeated motions preceded by more intense motions. The latter observation had not been reported in the literature to date. (2) Increases in peak drift demands were observed to be likely to occur if the first motion (in a sequence of motions containing a pair of repeated motions) is mild enough not to cause cracking and/or yielding, but the second instance of the same motion is preceded by larger intensity motions causing cracking and/or yielding.


  • Effect of displacement cycles on the drift capacity of reinforced concrete structural walls

    by Edgar Chacón-Valero, Santiago Pujol, Matías Hube, Liam Pledger, Charles Kerby

    Estimating the drift capacity (DC) of reinforced concrete (RC) structural walls is crucial to assess seismic performance of buildings in earthquake-prone regions. Numerous investigations have been conducted on the subject. Nevertheless, most of these investigations focus on walls without prior damage and a single expected earthquake. Recent tests conducted on RC walls suggest that displacement history does not affect DC, if the maximum amplitude of previous cycles is smaller than a threshold, regardless of the number of applied cycles. How to define such threshold and how prior cycles with amplitudes exceeding it affect DC remains unclear. This study assessed the effect of cyclic displacement history—or displacement cycles—on the DC of RC structural walls, using a statistical analysis. Results indicate that DC decreases as the intensity of cyclic displacement history increases. Nevertheless, this decrease is considerably smaller than differences between measured values of DC and estimates obtained using available empirical formulations and a calibrated machine learning algorithm.


  • Open Access

    On estimating the drift capacity of reinforced concrete walls with lap splices at their bases

    by W. Pollalis, C. Kerby, S. Pujol

    Failures in reinforced concrete (RC) structural walls have been reported to occur at longitudinal lap splices in earthquakes as far back as 1964 (Kunze et al. in JP 62:635–650, 1965) and as recently as 2023 (Pujol et al. in ES 63:777, 2024). Design codes such as ACI318-19 (2019) and JSCE Standard Specification for Concrete Structures (2007) have been adjusted accordingly and have banned the placement of lap splices near sections where longitudinal reinforcement is expected to yield in reinforced concrete structural walls. But minimizing lap splice vulnerabilities in new construction does not address existing buildings that may be vulnerable to earthquakes because of lap splices placed at or near critical sections. A simple, rapid assessment technique should be adopted to address the large number of existing buildings with potentially vulnerable RC walls. To investigate the deformation capacity of structural walls with lap splices near sections where longitudinal reinforcement yields, a two-part experimental program is ongoing: four large-scale walls with non-staggered lap splices were tested at Purdue University (Pollalis Drift capacity of reinforced concrete walls with lap splices, Purdue University: West Lafayette, 2021) and two large-scale walls with staggered lap splices have been tested at the University of Canterbury (Kerby et al. Experimental study of staggered lap splices in RC structural walls, 2023). Results from these six tests are added to a dataset of 15 previous tests of walls with non-staggered lap splices compiled by Almeida et al. (JSE 143:853, 2017). A method to estimate drift capacity of walls with lap splices is proposed based on estimates of lap splice strength, steel stress–strain relationships, and moment-area theorems. Two sets of assumptions can be used to produce estimates of drift capacity. The first set of assumptions applies when detailed information of reinforcement stress–strain relationships is available, and the second set of assumptions applies when reinforcement stress–strain relationships must be assumed. Both sets of assumptions produce reasonable estimates of the drift capacity of walls with lap splices, and the second set of assumptions can be used for rapid assessment given minimal information about the detailing and material properties of a wall.


  • Top Cited Papers
    Open Access

    Quantitative evaluation of the damage to RC buildings caused by the 2023 southeast Turkey earthquake sequence

    by Santiago Pujol, Idris Bedirhanoglu, Cemalettin Donmez, Jeffrey D Dowgala, Meltem Eryilmaz‐Yildirim, Kari Klaboe, Fahri Baran Koroglu, Rémy D Lequesne, Baki Ozturk, Liam Pledger, et al.

    Data from 15 earthquakes that occurred in 12 different countries are presented showing that, without better drift control, structures built with building codes allowing large seismic drifts are likely to keep leaving a wide wake of damage ranging from cracked partitions to building overturning. Following the earthquake sequence affecting southeast Turkey in 2023, a team led by Committee 133 of the American Concrete Institute surveyed nearly 250 reinforced concrete buildings in the area extending from Antakya to Malatya. Buildings ranging from 2 to 16 stories were surveyed to assess their damage and evaluate the robustness of their structures in relation to overall stiffness, as measured by the relative cross‐sectional areas of structural walls and columns. The majority of the buildings were estimated to have been built in the past 10 years. Yet, the structures surveyed were observed to have amounts of structural walls and columns comparable with amounts reported after the Erzincan (1992), Duzce (1999), and Bingol (2003) Earthquakes in Turkey. These amounts are, on average, much smaller than the wall and column amounts used in Chile and Japan. Because of that lack of robustness and given the intensities of the motions reported from Antakya to Malatya (with 10 stations with peak ground velocity (PGV) of 100 cm/s or more), it is concluded that structures in this region experienced large drifts. Excessive drift (1) exposed a myriad of construction and detailing problems leading to severe structural damage and collapse, (2) induced overturning caused by p‐delta for some buildings, and (3) caused widespread damage to brittle masonry partitions. The main lesson is simple: ductility is necessary but not sufficient. It is urgent that seismic drift limits are tightened in high‐seismicity regions worldwide.


  • Open Access

    Earthquake response of reinforced concrete frames with infill and active external confinement: Tests and dataset

    by Charles Kerby, Jonathan Monical, Santiago Pujol

    One option to retrofit reinforced concrete (RC) frames is the construction of infill walls. Infill increases lateral strength and stiffness but tends to reduce drift capacity relative to bare frames. Few studies have quantified the reductions in drift demand attributable to infills prior to failure. This report summarizes data from experiments designed to compare drift demands of frames with and without infill. Included data come from two experimental programs completed at Purdue University which focused on the in‐plane dynamic response of reduced‐scale, non‐ductile RC frames to uniaxial simulated earthquake ground motions. 254 dynamic tests were conducted on bare frames, frames with masonry infill walls, and frames with timber infill walls. In 11 of 14 test series, active confinement was applied to columns using external post‐tensioned reinforcement. The complete dataset is open‐access online on Zenodo, DOI: 10.5281/zenodo.6954967.


  • Dynamic response of a Single-Degree-of-Freedom system containing Phase Transforming Cellular Materials

    by William Pollalis, Prateek Shah, Yunlan Zhang, Nilesh Mankame, Pablo Zavattieri, Santiago Pujol


  • Open Access

    Observations about the seismic response of RC buildings in Mexico City

    by Sergio Alcocer, Anahid Behrouzi, Sergio Brena, Kenneth J Elwood, Ayhan Irfanoglu, Michael Kreger, Rémy Lequesne, Gilberto Mosqueda, Santiago Pujol, Aishwarya Puranam, et al.

    Over 2000 buildings were surveyed by members of the Colegio de Ingenieros (CICM) and Sociedad Mexicana de Ingenieria Estructural (SMIE) in Mexico City following the Puebla‐Morelos Earthquake of 2017. This inventory of surveyed buildings included nearly 40 collapses and over 600 buildings deemed to have structural damage. Correlation of damage with peak ground acceleration (PGA), peak ground velocity (PGV), predominant spectral period, building location, and building properties including height, estimated stiffness, and presence of walls or retrofits was investigated for the surveyed buildings. The evidence available suggests that (1) ground motion intensity (PGV) drove the occurrence of damage and (2) buildings with more infill and stiff retrofit systems did better than other buildings.