NSN. Sathishkumar

N. Sathishkumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


N. Sathishkumar has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A combined digital microfluidic test for assessing infection and immunity status for viral disease in saliva

    by N. Sathishkumar, Jose Gilberto Camacho Valenzuela, Nguyen H. Le, Anthony K. C. Yong, Martin A. Rossotti, Joshua Dahmer, Alexandros A. Sklavounos, Martin Plante, Daniel Brassard, Lidija Malic, et al.

    Population assessments of infection and immunity status are critical for public health response to infectious disease. Most microfluidic tools are developed to assess one or the other – few assess both. This study introduces a multiplexed, fully automated digital microfluidic (DMF) platform designed to detect viral protein as a proxy for infection status and host IgG and IgA antibodies as a marker for immunity status. SARS-CoV-2 and patient saliva were used as a model system to evaluate the concept. Specifically, the infection assay relied on nanobody-based capture and detection agents specific to SARS-CoV-2 trimeric spike protein, with a limit of detection (LOD) of 3.8 ng mL−1 in saliva. And the immunity relied on monoclonal antibodies for host IgG and IgA specific to SARS-CoV-2 spike S1 domain, with LODs of 4.8 ng mL−1 and 13.3 ng mL−1 in saliva, respectively. Clinical validation in saliva samples from human subjects experiencing symptoms (n = 14) showed strong correlation with PCR and commercial ELISA, achieving 100% sensitivity and 100% specificity for infection detection and 100% sensitivity with 91.7% and 90.9% specificity for host IgG and IgA, respectively. These results highlight potential applications for the new system as a portable diagnostic tool for outbreak surveillance and public health management, as a step toward preparing for the next global pandemic.


  • Open Access

    A compartmentalization-free microfluidic digital assay for detecting picogram levels of protein analytes

    by Nguyen H. Le, N. Sathishkumar, Alinaghi Salari, Ryan Manning, Raymond E. Meyer, Cheuk W. Kan, Alexander D. Wiener, Martin A. Rossotti, Sheldon Decombe, Richard P. S. de Campos, et al.

    This work introduces a compartmentalization-free digital detection technique that enhances sensitivity for detecting low-abundance proteins in an automated microfluidic format.


  • Direct comparison of colorimetric signal amplification techniques in lateral flow immunoassays

    by N. Sathishkumar, Bhushan J. Toley

    The lateral flow immunoassay (LFIA) is widely adopted for point-of-care testing, but its limit of detection (LoD) falls short of that of laboratory-based immunoassays. Several techniques have been proposed to enhance the LoD of LFIAs using visual colorimetric readouts, yet a direct comparison of the LoDs achieved by these techniques has not been performed. In this work, we measure the LoDs of LFIAs designed for the detection of a malaria protein, PfHRP2, using four different colorimetric signal generation techniques: (i) AuNP(40 nm)-tagged detection antibodies (base case), (ii) AuNP-based enhancement of AuNP(40 nm) signal, (iii) oxidation of chloronaphthol/diaminobenzidine (CN/DAB) using HRP-tagged detection antibodies, and (iv) oxidation of CN/DAB using polyHRP(400)-tagged detection antibodies. The LoDs and the 95% confidence intervals of the LoDs achieved by the 4 techniques were 19.34 (13.37–27.62) ng mL−1, 9.57 (6.76–13.28) ng mL−1, 21.57 (14.26–32.18) ng mL−1, and 6.09 (2.23–13.47) ng mL−1, respectively. Contrary to popular perception, enzymatic signal generation using HRP-tagged detection antibodies did not improve the LoD compared to the base case of AuNP-based signal generation. Further studies revealed that the very high extinction coefficient of gold nanoparticles renders them an excellent choice for colorimetric detection, surpassing the performance of enzymatic signal generation using HRP-tagged antibodies. However, enzymatic signal generation using polyHRP-tagged antibodies improved the LoD compared to the base case. These results show that enzymatic signal amplification should not be a priori assumed to be superior to AuNP-based signal generation; and provide a reference point to LFIA developers to select an appropriate signal generation modality.


  • Open Access

    Digital microfluidics with distance-based detection – a new approach for nucleic acid diagnostics

    by Man Ho, N. Sathishkumar, Alexandros A. Sklavounos, Jianxian Sun, Ivy Yang, Kevin P. Nichols, Aaron R. Wheeler

    There is great enthusiasm for using loop-mediated isothermal amplification (LAMP) in point-of-care nucleic acid amplification tests (POC NAATs), as an alternative to PCR. While isothermal amplification techniques like LAMP eliminate the need for rapid temperature cycling in a portable format, these systems are still plagued by requirements for dedicated optical detection apparatus for analysis and manual off-chip sample processing. Here, we developed a new microfluidic system for LAMP-based POC NAATs to address these limitations. The new system combines digital microfluidics (DMF) with distance-based detection (DBD) for direct signal readout. This is the first report of the use of (i) LAMP or (ii) DMF with DBD – thus, we describe a number of characterization steps taken to determine optimal combinations of reagents, materials, and processes for reliable operation. For example, DBD was found to be quite sensitive to background signals from low molecular weight LAMP products; thus, a Capto™ adhere bead-based clean-up procedure was developed to isolate the desirable high-molecular-weight products for analysis. The new method was validated by application to detection of SARS-CoV-2 in saliva. The method was able to distinguish between saliva containing no virus, saliva containing a low viral load (104 genome copies per mL), and saliva containing a high viral load (108 copies per mL), all in an automated system that does not require detection apparatus for analysis. We propose that the combination of DMF with distance-based detection may be a powerful one for implementing a variety of POC NAATs or for other applications in the future.


  • Open Access

    Transport Phenomena at Test and Control Lines in Lateral Flow Immunoassays Reveal a Path to Expanding Their Dynamic Range

    by Sathishkumar N, Bhushan Toley

    This study presents theoretical underpinnings for how the dynamic range of a lateral flow immunoassay (LFIA) may be expanded by real-time imaging. The dynamic range of a sandwich LFIA is limited by the ‘hook effect’, according to which, test line signal intensities reduce with increasing analyte concentration beyond a threshold analyte concentration. Rey et al. (Anal Chem, 2017, 89(9)) have shown experimentally that the hook effect in sandwich LFIAs may be mitigated by real-time imaging of test and control line, but theoretical understanding of the transport phenomena that govern this phenomenon is lacking. In fact, transport phenomena at the control line of an LFIA have never been modelled. In this paper, we use a transport-reaction model to understand how the kinetics of signal generation at the test and control lines of an LFIA relate to analyte concentration. Using this model, we developed a method for determination of analyte concentration accurately over a much larger range than the traditional end-point detection method. The model was validated using a commercially available lateral flow assay (home pregnancy test) on which real time imaging was conducted using a time-lapse app on a smartphone; there was a strong agreement between the predictions of our model and experiments results. The newly developed readout method increased the dynamic range for the detection of human chorionic gonadotropin (hCG) to 3 orders of magnitude (compared to ~1.5 orders of magnitude achieved by traditional end-point detection), without any modification to the test strip.

  • Experimental Measurement of Parameters Governing Flow Rates and Partial Saturation in Paper-Based Microfluidic Devices

    by Dharitri Rath, N. Sathishkumar, Bhushan J. Toley

    Paper-based microfluidic devices are rapidly becoming popular as a platform for developing point-of-care medical diagnostic tests. However, the design of these devices largely relies on trial and error, owing to a lack of proper understanding of fluid flow through porous membranes. Any porous material having pores of multiple sizes contains partially saturated regions, i.e. regions where less than 100% of the pores are filled with fluid. The capillary pressure and permeability of the material change as a function of the extent of saturation. While methods to measure these relationships have been developed in other fields of study, these methods have not yet been adapted for paper for use by the larger community of analytical chemists. In the current work, we present a set of experimental methods that can be used to measure the relationships between capillary pressure, permeability, and saturation for any commercially available paper membrane. These experiments can be performed using commonly available lab instruments. We further demonstrate the use of the Richard’s equation in modelling imbibition into 2D paper networks, thus adding new capability to the field. Predictions of spatiotemporal saturation from the model were in strong agreement with experimental measurements. To make these methods readily accessible to a wide community of chemists, biologists, and clinicians, we present the first report of a simple protocol to measure the flow rates considering the effect of partial saturation. Use of this protocol could drastically reduce the trial and error involved in designing paper-based microfluidic devices.


  • Multidimensional Paper Networks: A New Generation of Low-Cost Pump-Free Microfluidic Devices

    by Bhushan J. Toley, Debayan Das, Ketan A. Ganar, Navjot Kaur, Mithlesh Meena, Dharitri Rath, N. Sathishkumar, Shruti Soni