ETEleonora Tagliabue

Eleonora Tagliabue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eleonora Tagliabue has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Robust Distance Estimation With Out-of-Distribution Detection in Ophthalmic Surgery

    by Marius Briel, Ludwig Haide, Mathias Reincke, Rebekka Peter, Nicola Piccinelli, Gernot Kronreif, Franziska Mathis-Ullrich, Eleonora Tagliabue

    Micrometer-scale precision is vital for patient safety in ophthalmic surgery. Recent advancements in instrument-integrated optical sensors aim to accurately measure instrument-to-tissue distances. However, the reliability of these measurements is often hindered by segmentation errors caused by artifacts in the signal. We propose a deep learning framework to identify optical coherence tomography (OCT) M-scans that fall outside the expected distribution. Our approach incorporates adaptive remote center of motion (RCM)-informed retinal modeling along with time series analysis to effectively detect and rectify segmentation errors. This method estimates retinal distances and their associated confidence levels by leveraging retinal models, instrument positions, and validated distance data. Validation tests conducted on ex vivo human eyes reveal that our pipeline achieves an 88.8% accuracy in identifying out-of-distribution (OOD) measurements. Furthermore, distance estimation improved by 89% and 93% when compared to two existing methods, resulting in an overall mean absolute error (MAE) of less than 40 μm across diverse conditions, including scans with blood and obstructions. This research enhances the accuracy of instrument-to-retina distance estimation, thereby contributing to improved patient safety in ophthalmic surgical procedures. The proposed method has potential applications beyond ophthalmic surgery, offering benefits to a variety of surgical disciplines and sensorequipped instruments.

  • Rectification of Cornea Induced Distortions in Microscopic Images for Assisted Ophthalmic Surgery

    by Rebekka Peter, Erik Oberschulte, Atharva Vaidya, Thomas Lindemeier, Franziska Mathis-Ullrich, Eleonora Tagliabue

    Image distortions induced by the high refractive power of the eye's optical components challenge the accuracy of geometric information derived from intra-operative sensor data in ophthalmic surgery. Correcting these distortions is vital for advancing surgical assistance systems that rely on geometric scene comprehension. In this work, we focus on cornea induced distortions (CIDs) in surgical microscope images of the anterior eye. We employ a convolutional neural network (CNN) with stereo fusion layers to predict distortion distribution maps (DDMs) to correct CIDs in stereo images. To enable supervised learning, we introduce CIDCAT, a synthetic surgical microscope dataset generated through a rendering pipeline using a digital eye model. We address the domain gap between the synthetic training data and the unlabeled target domain of real surgical images by employing an auxiliary task of semantic segmentation to regularizes the feature encoder. Our rectification model reduces the cornea induced pupil radius error from 8.56% to 0.72% and improves the structural similarity by over 9% for synthetic CIDCAT images. Our semantic segmentation driven domain regularization technique enables the translation to real surgical images. The CIDCAT dataset enables the investigation of CIDs and the implementation of a CID rectification model. Our proposed CID rectification model demonstrate successful minimization of CIDs while preserving image integrity. The work represents a significant advancement in research on computer-assistance and robotic solutions for ophthalmic surgery that rely on a distortion-free, three-dimensional understanding of the patient's eye.


  • Open Access

    A Shared Control Architecture for Vitreoretinal Surgery With Safety Guarantee Using Control Barrier Functions

    by Nicola Piccinelli, Federico Vesentini, Marius Briel, Ludwig Haide, Eleonora Tagliabue, Marco Pellegrini, Gernot Kronreif, Riccardo Muradore

    Control Barrier Functions (CBFs) provide a powerful framework for enforcing real-time safety in control systems and have seen increasing applications in safety-critical domains, such as surgical robotics. In vitreoretinal microsurgery, where precision and tissue protection are crucial, we propose a shared control approach that leverages CBFs to maintain the robot's end-effector within a safe zone above the retina. Using real-time 3D reconstruction from an instrument-integrated Optical Coherence Tomography (iiOCT) system mounted on the surgical tool, we define a safety band between two offset surfaces derived from the reconstructed retina. A hybrid controller drives the tool into the band when outside and then enforces forward invariance using a CBF-based quadratic program. Concurrently, haptic feedback proportional to the deviation from the band centre guides the surgeon toward the optimal working distance. We validate our method in ex vivo pig eye experiments, performing a simulated Vitreous Shaving (VS), showing improved safety and operator awareness.


  • Open Access

    Assistive Functions in Robot-Assisted Vitreoretinal Surgery: A User Study from Phantom to In Vivo

    by Nicola Piccinelli, Ludwig Haide, Marius Briel, Alain Jungo, Eleonora Tagliabue, Moritz Schmid, Raphael Sznitman, Marco Pellegrini, Angeli Christy Yu, Massimo Busin, et al.

  • Distance-Based Shared Control for Vitreoretinal Surgery

    by Marius Briel, Dongyue Wu, Maximilian Hess, Ludwig Haide, Nicola Piccinelli, Gernot Kronreif, Marco Pellegrini, Eleonora Tagliabue, Franziska Mathis-Ullrich

    The fragility of ocular tissues combined with the limited surgical workspace demands precise instrument control and focus, making sensor-integrated robotic systems a promising solution. In this letter, we introduce a surgical system for telemanipulated endolaser photocoagulation that leverages instrument-integrated optical coherence tomography (iiOCT) for accurate distance measurement. We have developed a controller that maintains a specified instrument-to-retina distance, complemented by haptic shared control to assist the ophthalmic surgeon throughout the procedure. We conducted a pilot study involving 12 participants, including an expert vitreoretinal surgeon, to evaluate the system's performance across three levels of user assistance. The distance-based controller demonstrated a significant improvement in axial precison compared to telemanipulated trials, achieving a mean error of $4\,{\upmu}$m and a standard deviation of $69\,{\upmu}$m across all subjects. Experiments conducted on porcine eyes confirmed the feasibility of our approach on ex vivo tissues.


  • Open Access

    Autonomous Robotic Surgical Systems: Needing Common Sense to Achieve Higher Levels of Autonomy [Opinion]

    by Eleonora Tagliabue, Marco Bombieri, Paolo Fiorini, Diego Dall’aLba

    While executing a surgical procedure, surgeons not only rely on their specific medical knowledge but also on a set of skills that are “obvious” to them and allow for intuitively evaluating and reacting to the intervention evolution. Such skills belong to what is usually called common sense , which is essential to carry out an intervention. Although general common sense refers to all the basic concepts about the world and belongs to all human beings (e.g., the fact that a needle must be inserted from tip to eye), we believe that field-specific common sense is developed depending on individual experiences within a field of expertise. In surgery, field-specific common sense is the “glue” knowledge that is not explicitly described in surgical manuals, but it is acquired during lengthy surgical training. For example, a textbook does not explicitly describe how the needle should be held nor how it should be inserted in the human body, but this information is known by the domain experts. Understanding how to describe, represent, and learn this knowledge is paramount to developing robust and reliable autonomous robotic surgical systems (ARSSs). Developing ARSSs is a research trend of great interest for which taxonomies and paradigms have already been proposed. For more details, the reader is referred to [1] and [2]. The importance and challenges of common sense have been discussed in other fields [3], [4], but to the best of our knowledge, this aspect has not yet been addressed in robotic surgery.


  • Open Access

    Autonomous Robotic System for Breast Biopsy With Deformation Compensation

    by Sandro Ferrari, Eleonora Tagliabue, Bogdan Mihai Maris, Paolo Fiorini

    Image-guided biopsy is the most common technique for breast cancer diagnosis. Although magnetic resonance imaging (MRI) has the highest sensitivity in breast lesion detection, ultrasound (US) biopsy guidance is generally preferred due to its non-invasiveness and real-time image feedback during the insertion. In this work, we propose an autonomous robotic system for US-guided biopsy of breast lesions identified on pre-operative MRI. After initial MRI to breast registration, the US probe attached to the robotic manipulator compresses the breast tissues until a pre-determined force level is reached. This technique, known as preloading, will allow to minimize lesion displacement during the needle insertion. Our workflow integrates a deformation compensation strategy based on patient-specific biomechanical model to update the US probe orientation keeping the target lesion on the US image plane during compression. By relying on a deformation model, the proposed system does not require lesion visibility on US. Experimental evaluation is performed to assess the performance of the system on a realistic breast phantom with 15 internal lesions, considering different preloading forces. The deformation compensation strategy allows to improve localization accuracy, and as a consequence final probe positioning, for all considered lesions. Median lesion localization error is 3.3 mm, which is lower than the median lesion radius, when applying a preloading of 2 N, which guarantees both minimal needle insertion error and tissue stress.


  • Sim-to-Real Transfer for Visual Reinforcement Learning of Deformable Object Manipulation for Robot-Assisted Surgery

    by Paul Maria Scheikl, Eleonora Tagliabue, Balazs Gyenes, Martin Wagner, Diego Dall'ALba, Paolo Fiorini, Franziska Mathis-Ullrich

    Automation holds the potential to assist surgeons in robotic interventions, shifting their mental work load from visuomotor control to high level decision making. Reinforcement learning has shown promising results in learning complex visuomotor policies, especially in simulation environments where many samples can be collected at low cost. A core challenge is learning policies in simulation that can be deployed in the real world, thereby overcoming the sim-to-real gap. In this letter, we bridge the visual sim-to-real gap with an image-based reinforcement learning pipeline based on pixel-level domain adaptation and demonstrate its effectiveness on an image-based task in deformable object manipulation. We choose a tissue retraction task because of its importance in clinical reality of precise cancer surgery. After training in simulation on domain-translated images, our policy requires no retraining to perform tissue retraction with a 50% success rate on the real robotic system using raw RGB images. Furthermore, our sim-to-real transfer method makes no assumptions on the task itself and requires no paired images. This letter introduces the first successful application of visual sim-to-real transfer for robotic manipulation of deformable objects in the surgical field, which represents a notable step towards the clinical translation of cognitive surgical robotics.


  • Intra-operative Update of Boundary Conditions for Patient-Specific Surgical Simulation

    by Eleonora Tagliabue, Marco Piccinelli, Diego Dall’aLba, Juan Verde, Micha Pfeiffer, Riccardo Marin, Stefanie Speidel, Paolo Fiorini, Stéphane Cotin


  • Data-Driven Intra-Operative Estimation of Anatomical Attachments for Autonomous Tissue Dissection

    by Eleonora Tagliabue, Diego Dall'ALba, Micha Pfeiffer, Marco Piccinelli, Riccardo Marin, Umberto Castellani, Stefanie Speidel, Paolo Fiorini

    The execution of surgical tasks by an Autonomous Robotic System (ARS) requires an up-to-date model of the current surgical environment, which has to be deduced from measurements collected during task execution. In this work, we propose to automate tissue dissection tasks by introducing a convolutional neural network, called BA-Net, to predict the location of attachment points between adjacent tissues. BA-Net identifies the attachment areas from a single partial view of the deformed surface, without any a-priori knowledge about their location. The proposed method guarantees a very fast prediction time, which makes it ideal for intra-operative applications. Experimental validation is carried out on both simulated and real world phantom data of soft tissue manipulation performed with the da Vinci Research Kit (dVRK). The obtained results demonstrate that BA-Net provides robust predictions at varying geometric configurations, material properties, distributions of attachment points and grasping point locations. The estimation of attachment points provided by BA-Net improves the simulation of the anatomical environment where the system is acting, leading to a median simulation error below 5 mm in all the tested conditions. BA-Net can thus further support an ARS by providing a more robust test bench for the robotic actions intra-operatively, in particular when replanning is needed. The method and collected dataset are available at https://gitlab.com/altairLab/banet .