MBMarius Briel

Marius Briel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marius Briel has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Robust Distance Estimation With Out-of-Distribution Detection in Ophthalmic Surgery

    by Marius Briel, Ludwig Haide, Mathias Reincke, Rebekka Peter, Nicola Piccinelli, Gernot Kronreif, Franziska Mathis-Ullrich, Eleonora Tagliabue

    Micrometer-scale precision is vital for patient safety in ophthalmic surgery. Recent advancements in instrument-integrated optical sensors aim to accurately measure instrument-to-tissue distances. However, the reliability of these measurements is often hindered by segmentation errors caused by artifacts in the signal. We propose a deep learning framework to identify optical coherence tomography (OCT) M-scans that fall outside the expected distribution. Our approach incorporates adaptive remote center of motion (RCM)-informed retinal modeling along with time series analysis to effectively detect and rectify segmentation errors. This method estimates retinal distances and their associated confidence levels by leveraging retinal models, instrument positions, and validated distance data. Validation tests conducted on ex vivo human eyes reveal that our pipeline achieves an 88.8% accuracy in identifying out-of-distribution (OOD) measurements. Furthermore, distance estimation improved by 89% and 93% when compared to two existing methods, resulting in an overall mean absolute error (MAE) of less than 40 μm across diverse conditions, including scans with blood and obstructions. This research enhances the accuracy of instrument-to-retina distance estimation, thereby contributing to improved patient safety in ophthalmic surgical procedures. The proposed method has potential applications beyond ophthalmic surgery, offering benefits to a variety of surgical disciplines and sensorequipped instruments.

  • Open Access

    Intraoperative fusion of models and data for robust distance sensing

    by Marius Briel, Ludwig Haide, Tobias Weber, Alain Jungo, Nicola Piccinelli, Gernot Kronreif, Franziska Mathis-Ullrich, Eleonora Tagliabue

    Purpose: Instrument-integrated optical sensors are gaining popularity in microsurgery due to their ability to provide accurate measurements of instrument-to-tissue distances, enabling precise instrument control. However, obstructions in the optical path can result in measurement errors. In this work, we propose a method to improve robustness of distance information from sensorized microsurgical instruments. Methods: Our pipeline integrates a rapid search algorithm to identify relevant neighboring data points, as well as geometric and non-geometric techniques to accurately model the local tissue structure. Additionally, we implement a fusion of measurement and model to identify and overcome disturbances, e.g., obstructions from surgical instruments or semantic segmentation errors. Results: Our simulation examines the effect of different modeling parameters and techniques on distance prediction, yielding a mean absolute error of less than 0.02 mm when using the local spline fit. Experiments in ex vivo human eyes show that our pipeline achieves up to 89 % error reduction when compared to sensor only. Conclusion: Our method improves the reliability of instrument-integrated optical sensors. This work could enable distance-based instrument control in challenging conditions, thereby enhancing surgical precision in delicate ophthalmic procedures. Our approach can be generalized to any surgery with sensorized instruments and beyond.


  • Open Access

    A Shared Control Architecture for Vitreoretinal Surgery With Safety Guarantee Using Control Barrier Functions

    by Nicola Piccinelli, Federico Vesentini, Marius Briel, Ludwig Haide, Eleonora Tagliabue, Marco Pellegrini, Gernot Kronreif, Riccardo Muradore

    Control Barrier Functions (CBFs) provide a powerful framework for enforcing real-time safety in control systems and have seen increasing applications in safety-critical domains, such as surgical robotics. In vitreoretinal microsurgery, where precision and tissue protection are crucial, we propose a shared control approach that leverages CBFs to maintain the robot's end-effector within a safe zone above the retina. Using real-time 3D reconstruction from an instrument-integrated Optical Coherence Tomography (iiOCT) system mounted on the surgical tool, we define a safety band between two offset surfaces derived from the reconstructed retina. A hybrid controller drives the tool into the band when outside and then enforces forward invariance using a CBF-based quadratic program. Concurrently, haptic feedback proportional to the deviation from the band centre guides the surgeon toward the optimal working distance. We validate our method in ex vivo pig eye experiments, performing a simulated Vitreous Shaving (VS), showing improved safety and operator awareness.


  • Open Access

    Assistive Functions in Robot-Assisted Vitreoretinal Surgery: A User Study from Phantom to In Vivo

    by Nicola Piccinelli, Ludwig Haide, Marius Briel, Alain Jungo, Eleonora Tagliabue, Moritz Schmid, Raphael Sznitman, Marco Pellegrini, Angeli Christy Yu, Massimo Busin, et al.

  • Distance-Based Shared Control for Vitreoretinal Surgery

    by Marius Briel, Dongyue Wu, Maximilian Hess, Ludwig Haide, Nicola Piccinelli, Gernot Kronreif, Marco Pellegrini, Eleonora Tagliabue, Franziska Mathis-Ullrich

    The fragility of ocular tissues combined with the limited surgical workspace demands precise instrument control and focus, making sensor-integrated robotic systems a promising solution. In this letter, we introduce a surgical system for telemanipulated endolaser photocoagulation that leverages instrument-integrated optical coherence tomography (iiOCT) for accurate distance measurement. We have developed a controller that maintains a specified instrument-to-retina distance, complemented by haptic shared control to assist the ophthalmic surgeon throughout the procedure. We conducted a pilot study involving 12 participants, including an expert vitreoretinal surgeon, to evaluate the system's performance across three levels of user assistance. The distance-based controller demonstrated a significant improvement in axial precison compared to telemanipulated trials, achieving a mean error of $4\,{\upmu}$m and a standard deviation of $69\,{\upmu}$m across all subjects. Experiments conducted on porcine eyes confirmed the feasibility of our approach on ex vivo tissues.


  • Open Access

    Curvature-corrected retinal registration of diagnostic OCT with instrument-integrated OCT

    by Marius Briel, Ludwig Haide, Michael Meyling, Benjamin Saalfrank, Philipp Matten, Nicola Piccinelli, Gernot Kronreif, Maria Francesca Spadea, Eleonora Tagliabue, Franziska Mathis-Ullrich

    Vitreoretinal surgery, requiring precise microscale tissue manipulation, is well-suited for robotic assistance. Image registration enhances surgeons’ visual perception by aligning high-resolution preoperative OCT images with the intraoperative environment, improving visibility of anatomical features not seen in microscope images. However, optical distortions from the cornea, lens, eye curvature, and scanning patterns challenge the use of diagnostic data in robotic navigation. This study introduces a novel technique for curvature-corrected retinal registration, integrating diagnostic OCT with instrument-integrated OCT. The pipeline comprises feature extraction, curvature correction, initial alignment, and fine registration. Experiments using an artificial model eye and ex vivo porcine eye validate the method. Curvature correction achieves accuracy comparable to existing methods, with deviations of 17 $$\upmu$$ m for the model eye and 460 $$\upmu$$ m for the porcine eye. Post-registration, the fiducial marker error reduces to 103 $$\upmu$$ m for the model eye and 318 $$\upmu$$ m for the porcine eye. Our method provides intraoperative diagnostic context, enabling reliable topological assistance in retinal robotic systems.


  • Open Access

    Intraoperative 3-D Reconstruction and Geometric Modeling Using Sensorized Microsurgical Instruments

    by Marius Briel, Ludwig Haide, Jule Emmrich, Nicola Piccinelli, Gernot Kronreif, Eleonora Tagliabue, Franziska Mathis-Ullrich

    Precise micrometer-scale tissue manipulation is essential for successful microsurgery. Despite advancements in intraoperative sensing and instrument tracking, providing accurate real-time feedback on instrument positions relative to critical tissue structures remains challenging. This research aims to reliably reconstruct fine-grained anatomical surfaces intraoperatively using a smart instrument with fiber-based distance sensing. First, instrument-integrated optical coherence tomography sensor readings are integrated with instrument tracking to reconstruct accurate surface point clouds. Subsequently, radial basis functions, ordinary Kriging, and B-splines are utilized for surface modeling, employing tailored basis functions and smoothing parameters. The proposed methods are validated in the context of vitreoretinal surgery through simulations and with ex vivo studies involving porcine and human cadaver eyes. In simulations, radial basis function interpolation demonstrates the highest robustness across varying noise levels and eye shapes. In ex vivo studies, ordinary Kriging outperformed, yielding root mean square errors of 14.7 μm for the porcine eye and 38.1 μm for the human eye, with 99.7% and 96.5% of absolute errors below 100 μm. The proposed methods effectively model featurerich micro-anatomical surfaces and enable model-based assistance and automation, ultimately enhancing surgical precision in delicate ophthalmic procedures.


  • Open Access

    GEYEDANCE: An OCT-Enhanced Multi-Modal Feedback Platform for Robot-Assisted Ophthalmic Surgery

    by Nicola Piccinelli, Ludwig Haide, Marius Briel, Alain Jungo, Eleonora Tagliabue, Tommaso Da Col, Moritz Schmid, Raphael Sznitman, Marco Pellegrini, Angeli Christy Yu, et al.

    Vitreoretinal surgery includes a group of highly complex microsurgical procedures that demand precision. Robotic systems can enhance surgical performance, particularly for novice surgeons, while ensuring patient safety through advanced sensing capabilities. Optical Coherence Tomography (OCT), commonly used for eye anatomy imaging, is typically implemented via microscopes or diagnostic devices. This paper introduces the GEYEDANCE system, a bilateral teleoperated microsurgery platform integrating OCT directly at the end-effector of its remote manipulator, offering multi-modal feedback. The system enables intraoperative global eye modelling and surface reconstruction by exploiting a neural network-based tool-to-tissue distance estimation module. Its performance was validated in the operating room using ex-vivo eyes, effectively simulating the surgical steps of various vitreoretinal procedures.


  • Open Access

    Intraoperative adaptive eye model based on instrument-integrated OCT for robot-assisted vitreoretinal surgery

    by Marius Briel, Ludwig Haide, Maximilian Hess, Jan Schimmelpfennig, Philipp Matten, Rebekka Peter, Matthias Hillenbrand, Eleonora Tagliabue, Franziska Mathis-Ullrich

    Purpose: Pars plana vitrectomy (PPV) is the most common surgical procedure performed by retinal specialists, highlighting the need for model-based assistance and automation in surgical treatment. An intraoperative retinal model provides precise anatomical information relative to the surgical instrument, enhancing surgical precision and safety. Methods: This work focuses on the intraoperative parametrization of retinal shape using 1D instrument-integrated optical coherence tomography distance measurements combined with a surgical robot. Our approach accommodates variability in eye geometries by transitioning from an initial spherical model to an ellipsoidal representation, improving accuracy as more data is collected through sensor motion. Results: We demonstrate that ellipsoid fitting outperforms sphere fitting for regular eye shapes, achieving a mean absolute error of less than 40 $$\upmu \hbox {m}$$ μ m in simulation and below 200 $$\upmu \hbox {m}$$ μ m on 3D printed models and ex vivo porcine eyes. The model reliably transitions from a spherical to an ellipsoidal representation across all six tested eye shapes when specific criteria are satisfied. Conclusion: The adaptive eye model developed in this work meets the accuracy requirements for clinical application in PPV within the central retina. Additionally, the global model effectively extrapolates beyond the scanned area to encompass the retinal periphery.This capability enhances PPV procedures, particularly through virtual boundary assistance and improved surgical navigation, ultimately contributing to safer surgical outcomes.