Takao Ono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takao Ono has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
Kazuhiko Matsumoto
Osaka Univ, SANKEN, Ibaraki, Osaka 5670047, Japan
30 shared publications- Yasushi Kanai
International Center for Synchrotron Radiation Innovation Smart, Tohoku University, 468-1 Aramaki Aza-Aoba, Aoba-ku, Sendai 980-8572, Japan
24 shared publications - Shota Ushiba
Murata Manufacturing Co., Ltd., 1-10-1 Higashikotari, Nagaokakyo-shi, Kyoto 617-8555, Japan
15 shared publications Koichi Inoue
Osaka Univ, Ibaraki, Osaka 5670047, Japan
13 shared publicationsMasahiko Kimura
Murata Mfg Co Ltd, 1-10-1 Higashikotari, Nagaokakyo, Kyoto 6178555, Japan
11 shared publicationsShinsuke Tani
Murata Mfg Co Ltd, 1-10-1 Higashikotari, Nagaokakyo, Kyoto 6178555, Japan
9 shared publications
Latest Publications
- 9 March 2026
- Published by World Scientific Pub Co Pte Ltd in Fluctuation and Noise Letters
- Vol. 25 (05)
Preservability and Fluctuations in the Binding Activity of Sugar Chains to Influenza Viruses
An international influenza outbreak represents one of the most serious public health crises of global concern. The dissemination of influenza A virus variants necessitates continuous monitoring owing to the high mutation rate of the virus. Therefore, this study aimed to engineer a nanocarbon-based biosensor that is capable of identifying the preferred host of the virus. The practical implementation of biosensors for constant surveillance requires their preservation for several years. This paper documents the preservability of sugar chain probes using pyrenylated sialylglycopeptide and neoglycoprotein and examines relative errors associated with fluctuations in binding activity. Atomic force microscopy revealed that substantial relative errors may be associated with partially degraded sugar chains, and that the cleaning process appears to be crucial in probe preparation.
- 9 March 2026
- Published by World Scientific Pub Co Pte Ltd in Fluctuation and Noise Letters
- Vol. 25 (05)
Preservability and Fluctuations in the Binding Activity of Sugar Chains to Influenza Viruses
An international influenza outbreak represents one of the most serious public health crises of global concern. The dissemination of influenza A virus variants necessitates continuous monitoring owing to the high mutation rate of the virus. Therefore, this study aimed to engineer a nanocarbon-based biosensor that is capable of identifying the preferred host of the virus. The practical implementation of biosensors for constant surveillance requires their preservation for several years. This paper documents the preservability of sugar chain probes using pyrenylated sialylglycopeptide and neoglycoprotein and examines relative errors associated with fluctuations in binding activity. Atomic force microscopy revealed that substantial relative errors may be associated with partially degraded sugar chains, and that the cleaning process appears to be crucial in probe preparation.
- 1 April 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (4) , 049401
Erratum: Drift suppression of solution-gated graphene field-effect transistors through electrolyte submersion [Appl. Phys. Express 17 045002 (2024)]
- 1 April 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (4) , 049401
Erratum: Drift suppression of solution-gated graphene field-effect transistors through electrolyte submersion [Appl. Phys. Express 17 045002 (2024)]
- Open Access
- 1 April 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (4) , 045002
Drift suppression of solution-gated graphene field-effect transistors through electrolyte submersion
In solution-gated graphene FETs (SG-GFETs), cations in electrolyte solutions can intercalate between graphene and SiO2. Such permeation affects substrate-induced hole doping effects, resulting in drifts in the charge neutrality point (CNP) of SG-GFETs. In this study, we investigated the effect of submerging GFETs in electrolyte solutions on CNP values. The results revealed that the CNP decreased considerably from approximately 180 mV to nearly zero with the increase in the immersion period. The CNP drifts during electrical measurements were also suppressed by the prolonged submersion. These insights can be used for developing improved SG-GFETs.
- 1 April 2024
- Published by IOP Publishing in Applied Physics Express
- Vol. 17 (4) , 045002
Open AccessDrift suppression of solution-gated graphene field-effect transistors through electrolyte submersion
In solution-gated graphene FETs (SG-GFETs), cations in electrolyte solutions can intercalate between graphene and SiO2. Such permeation affects substrate-induced hole doping effects, resulting in drifts in the charge neutrality point (CNP) of SG-GFETs. In this study, we investigated the effect of submerging GFETs in electrolyte solutions on CNP values. The results revealed that the CNP decreased considerably from approximately 180 mV to nearly zero with the increase in the immersion period. The CNP drifts during electrical measurements were also suppressed by the prolonged submersion. These insights can be used for developing improved SG-GFETs.
- Open Access
- 23 March 2024
- Published by The Electrochemical Society of Japan in Electrochemistry
- Vol. 92 (3) , 037006
Graphene Field-Effect Transistors with Surface-Charge Modulation for C-Reactive Protein Detection in Artificial Saliva
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 23 March 2024
- Published by The Electrochemical Society of Japan in Electrochemistry
- Vol. 92 (3) , 037006
Open AccessGraphene Field-Effect Transistors with Surface-Charge Modulation for C-Reactive Protein Detection in Artificial Saliva
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 12 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP14
Great enhancement of sensitivity for SARS-CoV-2 detection by integrated graphene FET biosensor using ζ potential modulator
By modulating a ζ potential of graphene FET (G-EFT), the sensitivity of G-FET could be enhanced than that without modulation. Therefore, 1 × 107 FFU ml−1 SARS-CoV-2 was detected using G-FET modified with the ζ potential modulator which is the cation polymer with the positive charge. This method is based on the relationship between the surface charge and the sensitivity, in which the highest sensitivity is obtained when the ζ potential is 0 and/or the surface charge is almost 0. In this study, the microfluidic channel was installed on G-FET to get the precise result because it could wash away the free-floating virus and the physical adsorbed virus. 32 G-FETs including the reference FETs were integrated on the silicon substrate and the precise results were obtained by subtracting the noise terms.
- 12 February 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP14
Open AccessGreat enhancement of sensitivity for SARS-CoV-2 detection by integrated graphene FET biosensor using ζ potential modulator
By modulating a ζ potential of graphene FET (G-EFT), the sensitivity of G-FET could be enhanced than that without modulation. Therefore, 1 × 107 FFU ml−1 SARS-CoV-2 was detected using G-FET modified with the ζ potential modulator which is the cation polymer with the positive charge. This method is based on the relationship between the surface charge and the sensitivity, in which the highest sensitivity is obtained when the ζ potential is 0 and/or the surface charge is almost 0. In this study, the microfluidic channel was installed on G-FET to get the precise result because it could wash away the free-floating virus and the physical adsorbed virus. 32 G-FETs including the reference FETs were integrated on the silicon substrate and the precise results were obtained by subtracting the noise terms.
- Open Access
Challenges for Field-Effect-Transistor-Based Graphene Biosensors
Owing to its outstanding physical properties, graphene has attracted attention as a promising biosensor material. Field-effect-transistor (FET)-based biosensors are particularly promising because of their high sensitivity that is achieved through the high carrier mobility of graphene. However, graphene-FET biosensors have not yet reached widespread practical applications owing to several problems. In this review, the authors focus on graphene-FET biosensors and discuss their advantages, the challenges to their development, and the solutions to the challenges. The problem of Debye screening, in which the surface charges of the detection target are shielded and undetectable, can be solved by using small-molecule receptors and their deformations and by using enzyme reaction products. To address the complexity of sample components and the detection mechanisms of graphene-FET biosensors, the authors outline measures against nonspecific adsorption and the remaining problems related to the detection mechanism itself. The authors also introduce a solution with which the molecular species that can reach the sensor surfaces are limited. Finally, the authors present multifaceted approaches to the sensor surfaces that provide much information to corroborate the results of electrical measurements. The measures and solutions introduced bring us closer to the practical realization of stable biosensors utilizing the superior characteristics of graphene.
Open AccessChallenges for Field-Effect-Transistor-Based Graphene Biosensors
Owing to its outstanding physical properties, graphene has attracted attention as a promising biosensor material. Field-effect-transistor (FET)-based biosensors are particularly promising because of their high sensitivity that is achieved through the high carrier mobility of graphene. However, graphene-FET biosensors have not yet reached widespread practical applications owing to several problems. In this review, the authors focus on graphene-FET biosensors and discuss their advantages, the challenges to their development, and the solutions to the challenges. The problem of Debye screening, in which the surface charges of the detection target are shielded and undetectable, can be solved by using small-molecule receptors and their deformations and by using enzyme reaction products. To address the complexity of sample components and the detection mechanisms of graphene-FET biosensors, the authors outline measures against nonspecific adsorption and the remaining problems related to the detection mechanism itself. The authors also introduce a solution with which the molecular species that can reach the sensor surfaces are limited. Finally, the authors present multifaceted approaches to the sensor surfaces that provide much information to corroborate the results of electrical measurements. The measures and solutions introduced bring us closer to the practical realization of stable biosensors utilizing the superior characteristics of graphene.
- Open Access
- 13 December 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (51) , 49270-49277
Biosensing with Surface-Charge-Modulated Graphene Field-Effect Transistors beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits the sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and nonfunctionalized GFETs into a chip and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 13 December 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (51) , 49270-49277
Open AccessBiosensing with Surface-Charge-Modulated Graphene Field-Effect Transistors beyond Nonlinear Electrolytic Screening
In field-effect transistor (FET) biosensors, charge screening in electrolyte solutions limits the sensitivity, thereby restricting the applicability of FET sensors. This is particularly pronounced in graphene FET (GFET) biosensors, where the bare graphene surface possesses a strongly negative charge, which impedes the high sensitivity of GFETs owing to nonlinear electrolytic screening at the interfaces between graphene and liquid. In this study, we counteracted the negative surface charge of graphene by decorating positively charged compounds and demonstrated the sensing of C-reactive protein (CRP) with surface-charge-modulated GFETs (SCM-GFETs). We integrated multiple SCM-GFETs with anti-CRP antibodies and nonfunctionalized GFETs into a chip and measured differentials to eliminate background changes to improve measurement reliability. The FET response corresponded to the fluorescence images, which visualized the specific adsorption of CRP. The estimated dissociation constant was consistent with previously reported values; this supports the conclusion that the results are attributed to specific adsorption. Conversely, the signal in GFETs without decoration was obscured by noise because of nonlinear electrolytic screening, further emphasizing the significance of surface-charge modulation. The limit of detection of the system was determined to be 2.9 nM. This value has the potential to be improved through further optimization of the surface charges to align with specific applications. Our devices effectively circumvent nonlinear electrolytic screening, opening the door for further advancements in GFET biosensor technology.
- 3 November 2023
- Published by Elsevier in Microchemical Journal
- Vol. 196
Semi-quantitative graphene chemiresistor enzyme immunoassay for simple and sensitive antigen detection
- 3 November 2023
- Published by Elsevier in Microchemical Journal
- Vol. 196
Semi-quantitative graphene chemiresistor enzyme immunoassay for simple and sensitive antigen detection
- 1 June 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (6) , 067002
Elastomer-coated graphene biosensor and its response to enzymatic reactions
Graphene biosensors have the potential to be excellent applications of two-dimensional materials, because graphene has high mobility and specific surface area. However, it is difficult to stably obtain consistent responses from graphene biosensors owing to external disturbances and the lack of understanding their sensing mechanism. We propose a graphene biosensor coated with a gas-permeable silicone elastomer, poly(dimethylsiloxane). The elastomer coating allows only the gas molecules to reach the graphene surface, suppressing the disturbances from other factors, and thereby eliciting stable responses to target ammonia molecules in solution. It allowed us to clarify the relationship between ammonia production via urease reactions and conductivity changes of the graphene biosensor. The biosensor responses were modeled using the combination of the dissociation equilibrium of ammonia, Langmuir’s adsorption isotherm, and Michaelis–Menten equation. Findings of this study lay the foundation for practical applications of stable graphene biosensors based on our reasonable response model.
- 1 June 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (6) , 067002
Elastomer-coated graphene biosensor and its response to enzymatic reactions
Graphene biosensors have the potential to be excellent applications of two-dimensional materials, because graphene has high mobility and specific surface area. However, it is difficult to stably obtain consistent responses from graphene biosensors owing to external disturbances and the lack of understanding their sensing mechanism. We propose a graphene biosensor coated with a gas-permeable silicone elastomer, poly(dimethylsiloxane). The elastomer coating allows only the gas molecules to reach the graphene surface, suppressing the disturbances from other factors, and thereby eliciting stable responses to target ammonia molecules in solution. It allowed us to clarify the relationship between ammonia production via urease reactions and conductivity changes of the graphene biosensor. The biosensor responses were modeled using the combination of the dissociation equilibrium of ammonia, Langmuir’s adsorption isotherm, and Michaelis–Menten equation. Findings of this study lay the foundation for practical applications of stable graphene biosensors based on our reasonable response model.
- 26 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
- Vol. 1 (4) , 1086-1092
Carrier-Type Switching with Gas Detection Using a Low-Impedance Hybrid Sensor of 2D Graphene Layer and MoOx Nanorod 3D Network
- 26 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Engineering Materials
- Vol. 1 (4) , 1086-1092
Carrier-Type Switching with Gas Detection Using a Low-Impedance Hybrid Sensor of 2D Graphene Layer and MoOx Nanorod 3D Network