HŞHasan Selim Şengel

Hasan Selim Şengel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hasan Selim Şengel has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • DESIGN AND STRUCTURAL ANALYSIS OF A PRECAST INDUSTRIAL BUILDING

    by Tezcan Turalı, R. Tuğrul Erdem, Tolga Yılmaz, H. Selim Şengel

    This study examines the design and structural analysis of a precast reinforced concrete industrial building composed of three halls. The building includes a partial second floor located in the upper left section of the plan, where the story heights are 438 and 440 cm respectively. The structural system consists of precast columns and beams, roof purlins, trusses, gutter elements, and the connection details that link these components. The use of a precast system is preferred in industrial construction because it shortens production and installation time, reduces overall cost, and significantly minimizes on site operations. The structural analysis was carried out with the Sap2000 program, and dead, live, snow, wind, and seismic loads were modeled in accordance with the relevant national standards. The design process followed the requirements of TS 498, TS EN 1991-1-3, TS EN 1991-1-4, Specification for the Design, Calculation and Construction of Steel Structures-2016, and the Turkish Building Earthquake Code 2018. The behavior of the building was evaluated using a linear elastic analysis approach, and the resulting displacements, internal forces, and connection forces remained within code limits. An increase in stiffness was observed in the region containing the second floor, and this condition contributed positively to the overall stability of the structure. The findings indicate that the building provides a balanced load carrying capacity under both vertical and horizontal actions, demonstrating that precast reinforced concrete systems offer a reliable and economically advantageous solution for industrial facilities.

  • Open Access

    Performance investigation of a mixed slab building with beam and ribbed slabs

    by Burak Yüksek, Recep Tuğrul Erdem, Tolga Yılmaz, Hasan Selim Şengel

    Over time deterioration in material properties, unauthorized modifications, or construction defects can negatively affect the seismic behavior of structural members. Therefore, the in-situ identification and performance analysis of reinforced concrete elements, carried out to ensure the safety of the existing building stock, have become a fundamental part of examining structural characteristics and developing disaster risk reduction strategies. In this study, the structural performance analysis of an existing reinforced concrete building with a mixed slab system was conducted by using the STA4CAD V13.1 software. For this purpose, nonlinear pushover analysis was performed for each seismic direction. As the existing reinforced concrete building did not satisfy the requirements for the single-mode method prescribed in TBDY (2018), a multi-mode pushover analysis was conducted for the structure. Based on the results of nonlinear multi-mode pushover analysis, the damage states of the structural members were determined, and the performance level of the structure was evaluated. The targeted performance level of controlled damage, as defined in the Turkish Building Earthquake Code-2018 TBEC (2018), could not be achieved for the analyzed residential-type reinforced concrete building. However, the collapse prevention performance level was determined due to the damage occurrence in the structural elements.

  • On the evaluation of lateral-torsional buckling of web-tapered cantilevers with doubly symmetric I-section

    by Tolga Yılmaz, Mustafa Sertçelik, Hasan Selim Şengel

    Recently, structural engineers have tended to design stronger and lighter structures due to economic reasons, technical developments in computer-aided design, and improvements in manufacturing. The demand for designing stronger and lighter structures has led to the compulsory considering structural efficiency and stability loss at the design level. Lateral-torsional buckling (LTB) is a major stability loss for web-tapered cantilevers with doubly symmetric I-section, which are aesthetic and structurally efficient. The elastic LTB loads of these cantilevers should be calculated at the design level since the LTB may happen before bending stress reaches yield. Studies related to the LTB of cantilevers are rare and require numerical solutions since the LTB mode shape of cantilevers is complex compared to simply supported beams. The present study introduces an analytical procedure based on the energy method for calculating elastic LTB of web-tapered cantilevers with doubly-symmetric I-section in two different forms. The analytical model considers different transverse load types, positions of loads, and web tapering degrees. The analytical solutions were validated with one-dimensional finite element analysis using a beam element. Excellent accordance between results was demonstrated. The general LTB behavior of web-tapered cantilevers with doubly symmetric I-section was clarified with detailed comments based on results obtained from the presented analytical model.


  • Effect of waste steel tire wired concrete on the mechanical behavior under impact loading

    by Hasan Selim Şengel, Kutluhan Ethem Kınık, Hakan Erol, Mehmet Canbaz

    In this experimental study the effect of waste steel tire wire was investigated on the concrete bollards of mechanical behavior under impact loading. Concrete bollards were produced using three different dimensions with three different volumes of waste steel tire wire (0%, 5% and 10%). The concrete was 30 MPa strength. The concrete bollards were cast into molds with a size of 100x100 mm, 150x150 mm and 200x200 mm and standard length of 1100 mm prism. Nine cube specimens of three different dimensions are tested. 84 kg of an impact load is used with the drop height of 400 mm in this study. Compressive strength tests were achieved. Concrete bollards were kept in laboratory standard conditions. According to the results of study compressive strength of the concrete vary between 25-30 MPa. The use of waste steel tire wire in the concrete bollards contributes to the less crack, less deflection, more acceleration and more energy dissipation at the end of the specimens. The experimental test aimed to research the effect of waste steel tire wired concrete on the mechanical behavior under impact loading as a possible environmentally friendly and sustainable solution. It can be said that the results provide the potential usage of waste steel tire wire manufacturing friendly to nature and sustainability of the concrete bollards. Generally, the usage of waste steel tire wire in concrete could be an innovative method in the construction industry.


  • Effect of steam‒curing on the glass fiber reinforced concrete

    by Mehmet Canbaz, Mouad Bensaoud, Hakan Erol, Hasan Selim Şengel

    Due to the increased need to use precast concrete to reduce construction duration and to accelerate the cement reaction process to achieve the required concrete resistance that enables the elements to gain the required strength to handle the loads generated by the transportation process, many companies use steam curing methods to expedite the hydration process. The steam curing process negatively affects the concrete strength, especially in the long term. Fibers of different types are used to improve the interior composition of concrete and increase its crack resistance. The purpose of the current study was to determine the effect of the glass fiber on the behavior of steam-cured concrete. In this study 90 concrete cubes were used with 15cm dimensions, three different weight ratios of glass fibers (0%, 0.12%, and 0.24%) with two curing methods standard curing in the water tank (water curing - WC) for 3, 7, and 28 days, and steam curing (SC) for 4 and 8 hours. Nine specimens of each mix were cast in 12 mm, and 24 mm fibers length and tested for each curing duration and method. The results of this study indicate that fiber glass addition to the steam-cured concrete has a positive effect on the concrete unit weight and the ultrasonic pulse velocity. Moreover, the result showed that the tensile and compressive strength of the concrete has been positively affected by the length of the fiber more than the fiber weight percentage.


  • Mechanical behavior investigation of rubberized concrete barriers in impact load

    by Hasan Selim Şengel, Ahmet Şahin Özgören, Hakan Erol, Mehmet Canbaz

    Approximately 1.5 million waste tires are produced annually. Waste tires in landfills and stocks cause toxic chemicals to pollute the soil and cause major fires. Waste tires are a global environmental problem. This problem gave an idea of recycling of waste tires instead of landfills and stocks. In this paper, an experimental study is conducted to review the behavior under impact load of rubberized concrete with conventional concrete. Three different mixes were made by adding crumb rubber (0%, 5% and 10%) by volume to the concrete. Nine cantilever column specimens of three type cross section (10x10, 15x15 and 20x20 cm2) were used to investigate the behavior under impact load. The specimens with higher rubberized concrete have longer impact load duration at the initial peak point. Specimens with rubber content become much flexible than normal specimens. Furthermore, the damage level of columns is greater with increasing rubber content. Therefore, the specimens with higher rubberized concrete absorb more impact energy. The barriers with higher rubber content minimize injury and demise when an accidental impact happens. Using concrete with rubber content reduces costs and produces an environmentally sustainable solution.

  • Numerical evaluation of reinforced concrete slabs with fixed support under impact load

    by Tolga Yılmaz, Hasan Selim Şengel

    Reinforced concrete (RC) structural members may be subjected to impact load besides quasi-static load or other dynamic loads like earthquake and wind loads in their service periods. Many research emphasized that although impact load acts on structural members for a short time, it caused considerable damage to these members or even collapses the whole structure. Thus, it becomes crucial to consider and accurately evaluate the impact load effect in the design process. The present study intends to introduce a finite element model (FEM) verified with the test data for the accurate evaluation of load-deflection behavior and damage patterns of the fixed supported RC slabs exposed to impact load. First, a nonlinear FEM including strain-rate effect for both concrete and steel reinforcement, and crack visualization algorithm has been established by using LS-DYNA software. Then, the dynamic responses obtained by the present FEM have been compared with the experimental data presented in a previous study existing in the literature and it is found that the present FEM yields accurate results for the RC slab subjected to impact load and it can be safely used in the design process. In the second part of the study, using the verified FEM, the effects of applied input impact energy, the application point of impact load, and hammer geometry on the dynamic responses and failure characteristics of the RC slabs exposed to the impact loading were investigated and interpreted in detail.


  • Effect of carbon fibers on the mechanical properties of steam-cured concrete

    by Mehmet Canbaz, Mouad Bensaoud, Hakan Erol, H. Selim Şengel

    While the use of the steam-curing method in the precast concrete can result in an early high compressive strength and thus can increase the production rate of structural elements, it should be noted that the steam-curing method has some negative effects on the mechanical properties of concrete due to the fact that the high-temperature steam causes micro-cracks. On the other hand, the inclusion of carbon fibers enhanced the overall mechanical properties in terms of high tensile strength and modulus of elasticity. This paper aimed to investigate the effect of adding carbon fibers to steam-cured concrete. Twenty-seven cube specimens of 15 cm dimensions were used to investigate the unit weights, the ultrasonic pulse velocity, the compressive strength, and the split tensile strength of the concrete. Three different mixes were made by adding carbon fibers (0%, 0.12% and 0.24%) by weight to the concrete. Three of each were kept in a standard curing environment for 3, 7 and 28 days. Three specimens of each mix were steam-cured for 4 hours, and three specimens were steam-cured for 8 hours. The result showed a significant increase in the rate of gaining compressive strength under steam-curing with an enhancement in the tensile strength due to the presence of fibers, all without compromising the integrity of the concrete and without increasing the amount of voids.

  • Open Access

    TONOZ ÇATILI YAPILARA ETKİYEN RÜZGÂR YÜKÜ TESİRLERİNİN ASCE, AIJ, AS/NZS VE TS EN 1991-1-4 YÖNETMELİKLERİNE GÖRE KARŞILAŞTIRILMASI

    by Muhammed Karagöz, Hasan Selim Şengel

    Mühendisler tarafından tasarımı yapılan binalar kullanıcılarına hizmet ettiği sürece karşılaşacakları yükleri güvenli şekilde taşıyacak dayanımda tasarlanırlar. Yapıların ömürleri boyunca karşılaşacakları birçok yük etkisi vardır. Bunlardan bir tanesi de rüzgâr yüküdür. Bu çalışmada dikdörtgen taban alanı olan ve tonoz çatı tipinde çatısı bulunan bir yapı seçilmiş ve rüzgâr yükleri altında meydana gelen yük değerleri elde edilmeye çalışılmıştır. Binaya etkiyen rüzgâr yükleri TS EN 1991-1-4, ASCE 7.05, AIJ, AS/NZS yönetmelikleri kullanılarak elde edilmiştir. Yükseklikleri 6m, 8m, 10m ve 12 metre olan ve tonoz çatı yüksekliği ise 1,5 metre olan yapı örnekleri kullanılmıştır. Rüzgâr etkisi sonucu ön duvarlar, arka duvarlar ve çatı yüzeylerinde oluşan dış basınç katsayılar elde edilmiştir. Bu basınç katsayıları kullanılarak taban kesme kuvveti ve taban moment değerleri elde edilmeye çalışılmıştır. Elde edilen sonuçlar birbiri ile kıyaslanmış ve sonuçlar hakkında yorumlar yapılmıştır.

  • Analysis of historical structures by using finite element method in Iznik Yeşil Mosque

    by Aykut Uray, Hasan Selim Şengel, Serdar Çarbaş

    In this study, non-destructive tests and laboratory tests were carried out in order to determine the material properties in Iznik Yeşil Mosque, Iznik District, Bursa Province. For the purpose of determining the soil characteristics of the building, the soil survey studies conducted in the Iznik Yeşil Mosque area were investigated. The finite element model was formed by making a three dimensional model study of the structure. With the finite element model, static analysis, modal analysis and behavioral spectrum analysis were performed under vertical loads in order to collect data for the damaged areas of the structure.