MVMayra Torres Vasques

Mayra Torres Vasques

*This is an algorithmically generated author record based on publicly available information.

Mayra Torres Vasques has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Aging and post-polymerization effects on conversion degree and properties of additive splint materials

    by Leandro Ruivo de Santis, Lucas Silveira Fernandes, Mayra Torres Vasques, Nataly Rabelo Mina Zambrana, Ítallo Emídio Lira Viana, Taís Scaramucci Forlin, Guilherme de Siqueira Ferreira Anzaloni Saavedra, Carlos Eduardo Francci

    The study objective was to analyze dimensional change, flexural strength, surface hardness, wear profile, and conversion degree of different additive splint materials under various post-polymerization conditions of time and artificial aging. Two additive manufacturing systems (Cara Print 4.0, Dima Print Ortho, Kulzer; SprintRay Pro, SprintRay Splint, SprintRay), and a thermally activated resin control (Clássico) were evaluated in artificial aging (deionized water or saliva; 28 or 84 days at 37°C), with recommended or doubled post-polymerization cycles. Dimensional change (surface metrology), flexural strength (ISO 20795-1:2013), fractography (SEM), Knoop hardness, two-body wear profilometry (150,000 cycles; 3mmØ; 20N; 2.1Hz), and conversion degree (FTIR spectroscopy) were assessed. Two-way ANOVA and post-hoc Tukey tests were used for parametric data, and Kruskal-Wallis and post-hoc Dunn tests, for non-parametric data (α = 0.05). Results indicated no statistically significant differences in dimensional change or flexural strength among the materials. Recommended post-polymerization cycles resulted in lower hardness for additive resins than the thermally activated control. Doubling post-polymerization time significantly increased flexural strength and hardness of Dima Print Ortho, but decreased flexural strength of SprintRay Splint, and did not affect wear resistance. Dima Print Ortho demonstrated the highest wear resistance. Artificial aging did not affect flexural strength, surface wear, or dimensional change, but negatively impacted the hardness of all materials except Dima Print Ortho. The conversion degree was unaffected by post-polymerization time, and no significant differences were found among the materials. Overall, additive materials exhibited mechanical and dimensional properties comparable to thermally activated resin, with doubling post-polymerization time positively influencing the properties.


  • Open Access

    Clinical profile of Brazilian patients with temporomandibular joint disorder and orofacial pain: A 20-year retrospective study

    by Reinaldo Missaka, Sérgio Nakazone, Mayra Torres Vasques, Albani Gouveia Zampol, Lucas Silva Mendes, Márcio Katsuyoshi Mukai, Maria Gabriela Haye Biazevic, Rosemary Sadami Arai Shinkai, Tomie Toyota de Campos

    Temporomandibular joint disorder (TMD) comprises several musculoskeletal conditions in the orofacial region, with chronic pain and/or dysfunction involving the temporomandibular joint (TMJ) and masticatory muscles. This study assessed the clinical characteristics of patients with TMD treated at a public tertiary care facility in Brazil. In this retrospective study, we assessed data from adult patients attending the Center for Occlusion, TMD, and Orofacial Pain at a Brazilian school of dentistry, from 2000 to 2020. Data from eligible charts were collected: demographic variables, clinical complaints, location of pain, pain intensity (10-point VAS), duration of treatment, and therapeutic procedures. Data were analyzed using descriptive and inferential statistics at the 0.05 significance level. The sample consisted of 2324 patients (79.4 % females) with a median age of 38 years and median duration of treatment of 35 days. Major clinical complaints were craniofacial pain (including in the TMJ region) (82.9 %), self-reported bruxism (clenching/grinding) (44.6 %), and clicking/crepitation (39.1 %). Craniofacial pain was associated with female gender and age of 39 years and older, but not with bruxism. The most frequent procedures were counseling (96.5 %), exercises (47.5 %), occlusal splints (18.5 %), and physiotherapy (13.8 %). Reduction in pain intensity was moderately associated with multiple (3 or more) therapies and longer duration of treatment. It can be concluded that the patients presented a diversity of clinical characteristics requiring individualized treatment. A multimodal, interdisciplinary therapeutic approach, including counseling, appears to benefit most patients with TMD-related pain.


  • Open Access

    Accuracy Comparison among 3D-Printing Technologies to Produce Dental Models

    by Jun Ho Kim, Otavio Henrique Pinhata-Baptista, Ana Paula Ayres, Renan Lúcio Berbel da Silva, Jacqueline Ferreira Lima, Gabriel Sardinha Urbano, Juliana No-Cortes, Mayra Torres Vasques, Arthur Rodriguez Gonzalez Cortes

    Background: Little is known on accuracy comparisons among 3D-printing trueness and precision to produce dental models. The purpose of this study was to investigate the accuracy of different 3D-printing technologies (SLA; DLP; LCD poly and monochromatic; and Polyjet). Methods: Fifteen models were manufactured by the five different 3D printers used in this study. The manufactured models were physically measured in the corresponding lengths for trueness and reproducibility. Means and standard deviations were obtained for the five computer-aided manufacturing (CAM) methods and compared. Results: No significant difference was found in the comparison between observers in all measurements performed with the different model algorithms. Pairwise Wilcoxon non-parametric test comparisons of trueness between 3D-printers revealed statistically significant differences between Stratasys versus Anycubic (p = 0.025) and Anycubic versus Form 2 (p = 0.048). Conclusion: The present findings suggest that the 3D-printing methods may have small significant discrepancies when compared to the original digital files, which may not be clinically relevant. In addition, there were no significant discrepancies among median measurements of each printing method (within 3D-printer analysis), which suggests that, for dental casts, all of the studied devices performed similarly.


  • Open Access

    The influence of the post-processing method on knoop hardness of photosensitive resins for 3D SLA printer used in Dentistry

    by Mayra Torres Vasques, Julia Nascimento Mulder, Debora Santos Machado, Dalva Cruz Lagana

    Objectives: The aim of this study is to compare the mechanical characteristics of resins for 3D printers with the acrylic resins that have been used in Dentistry, according to the post-processing method. Materials and Methods: Using an SLA 3D printer (Form 2 – Formlabs, Massachusetts, USA), samples (discs) were produced with the printer’s resins, Dental SG®, Dental LT®, Clear®, and Grey®. Samples made of thermopolimerized and auto polymerized acrylic resins were produced as well (Gold Standart parameters). The Knoop Hardness (KH) tests were performed using microdurometer HMV-2 (Shimadzu, Kyoto, Japan). Results: The results showed the Dental SG resin presented the highest KH, compared with thermopolimerized acrylic resin, the Clear and Dental LT resins KH were compared with auto polymerized acrylic resin, and the non-post cured Grey resin (not for intraoral use), as well as the Dental LT resin, showed the lowest KH. Conclusions: Considering the hardness, the printer’s resins are comparable with the acrylic resins established, when the post-processing method is thoroughly followed. The absence of material’s post-processing reduce significantly the material’s hardness. Clinical relevance: Regarding the use of 3D printing in Dentistry, the development of materials adequate for the equipment, biocompatible for intraoral uses, and compatible mechanical proprieties are essential.


  • Open Access

    Accuracy and Internal Fit of 3D printed Occlusal Splint, according to the printing position

    by Mayra Torres Vasques, Dalva Cruz Laganá

    Understanding the importance of 3D printing strategies is a key to obtain predictable, optimized and consistent dental appliances using digital technologies. This study aims to present the influence of printing orientation on the intraoral fit of full arch coverage splints. Splints were designed for two patients using the CAD software and printed in a SLA 3D printer with different orientations (0, 30, and 90 degrees), and the internal fit was checked on patients’ mouth. Differen­ces between the fit of the splints were verified, with the worst results for 90º oriented splints, although more detailed studies are recommended by the authors. DESCRIPTORS | Three-Dimensional Printing; Accuracy; Dimensional Measurement; Occlusal Splint; Print Orientation.