Carlos Eduardo Francci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos Eduardo Francci has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Francisco Cesar
Universidade de São Paulo, Brazil
3 shared publications - Camila Pontes Custódio
Department of Prothesis, School of Dentistry University of São Paulo São Paulo Brazil
2 shared publications - Guilherme Schmitt de Andrade
Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos 12245-000, SP, Brazil
2 shared publications - Guilherme de Siqueira Ferreira Anzaloni Saavedra
Universidade Estadual Paulista, Brazil
2 shared publications - João Paulo Mendes Tribst
Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam, and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, North Holland, The Netherlands
2 shared publications - Samara Franco da Silva
Department of Biomaterials and Oral Biology, School of Dentistry University of São Paulo São Paulo Brazil
2 shared publications
Latest Publications
- Open Access
Adhesive Cementation of Glass-Fiber Posts: A Narrative Review of Materials and Techniques
This review aims to synthesize current evidence-based protocols to guide clinicians toward predictable and durable adhesive cementation of glass-fiber posts in intraradicular dentin. Endodontically treated teeth (ETTs) frequently exhibit significant structural loss, requiring additional retention strategies, such as glass-fiber posts bonded with resin cements. Clinical outcomes depend on multiple factors, including adequate dentin substrate preparation, appropriate adhesive strategies, and precise cementation techniques. The presence of smear layer debris may compromise adhesion; therefore, effective cleaning protocols are essential to ensure a contaminant-free substrate. Surface treatments of glass-fiber posts may enhance chemical bonding by exposing glass fibers and improving silane coupling. The selection of resin cement systems must consider limitations related to light transmission, polymerization depth, and the adhesive strategy employed. Moisture control and proper solvent volatilization are critical to optimizing bond strength, as is the prevention of contamination during cement application. Techniques that minimize porosity improve cement homogeneity and reduce interfacial defects that may act as failure initiation sites. Furthermore, the choice of core build-up material plays an important role in restoration durability. Collectively, these considerations demonstrate the importance of material selection and clinical technique in achieving reliable adhesive cementation of glass-fiber posts.
Open AccessAdhesive Cementation of Glass-Fiber Posts: A Narrative Review of Materials and Techniques
This review aims to synthesize current evidence-based protocols to guide clinicians toward predictable and durable adhesive cementation of glass-fiber posts in intraradicular dentin. Endodontically treated teeth (ETTs) frequently exhibit significant structural loss, requiring additional retention strategies, such as glass-fiber posts bonded with resin cements. Clinical outcomes depend on multiple factors, including adequate dentin substrate preparation, appropriate adhesive strategies, and precise cementation techniques. The presence of smear layer debris may compromise adhesion; therefore, effective cleaning protocols are essential to ensure a contaminant-free substrate. Surface treatments of glass-fiber posts may enhance chemical bonding by exposing glass fibers and improving silane coupling. The selection of resin cement systems must consider limitations related to light transmission, polymerization depth, and the adhesive strategy employed. Moisture control and proper solvent volatilization are critical to optimizing bond strength, as is the prevention of contamination during cement application. Techniques that minimize porosity improve cement homogeneity and reduce interfacial defects that may act as failure initiation sites. Furthermore, the choice of core build-up material plays an important role in restoration durability. Collectively, these considerations demonstrate the importance of material selection and clinical technique in achieving reliable adhesive cementation of glass-fiber posts.
- Open Access
- 23 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Translucency Changes of Ceramic Veneers After Aging When Cemented on Substrates With Different Saturation: Effect of Ceramic Translucency and Resin Cement Shade
Objective: To evaluate the effect of ceramic translucency and resin cement shade on the translucency alteration after aging over different substrates. Methods: Sixty specimens were divided into 12 groups ( n = 5) composed of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) in three translucencies (HT, MT, LT). The 0.5 mm thick specimens were cemented with Variolink Esthetic LC (Ivoclar Vivadent) Light+ (L+) and Neutral (N) over resin substrates A1 and A4. Samples were subjected to 20,000 aging thermocycles, alternating 55°C–5°C (30 s). Spectral reflectance was measured using a spectrophotometer (CM‐3700d—Konica Minolta) at four intervals: before aging (t0) and after 10,000 (t10), 15,000 (t15), and 20,000 (t20) cycles. The Translucency Parameter (TP 00 ) and the ΔTP 00 were calculated. The thresholds for translucency perceptibility (TPT 00 ) and acceptability (TAT 00 ) were set at 0.62 and 2.62, respectively. Statistical analysis was performed using four‐way repeated measures ANOVA and Tukey's post hoc test ( α = 0.05). Results: Aging time, ceramic translucency, resin cement color and substrate saturation had a significant effect ( p < 0.001) on TP 00 . While TP 00 values declined across all groups, the lowest values for each measurement moment were consistently observed in the LTL+ groups [1.70 (t0) to 0.90 (t20)]. All ΔTP 00 values remained below the acceptability threshold (TAT = 2.62). Conclusion: Aging resulted in a generalized decrease in translucency across all groups, particularly over lighter substrates and when using chromatic resin cement. However, no clinically unacceptable alterations were observed. Clinical Significance: Clinicians should select materials based on the balance between initial masking and long‐term stability. For dark substrates, LT ceramics ensure consistent optical stability during aging, regardless of the resin cement shade. While combining translucent ceramics (HT/MT) with chromatic resin cements is an effective strategy for initial masking, clinicians must be aware that ceramic translucency is the primary factor controlling the final optical outcome over time.
- 23 August 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessTranslucency Changes of Ceramic Veneers After Aging When Cemented on Substrates With Different Saturation: Effect of Ceramic Translucency and Resin Cement Shade
Objective: To evaluate the effect of ceramic translucency and resin cement shade on the translucency alteration after aging over different substrates. Methods: Sixty specimens were divided into 12 groups ( n = 5) composed of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) in three translucencies (HT, MT, LT). The 0.5 mm thick specimens were cemented with Variolink Esthetic LC (Ivoclar Vivadent) Light+ (L+) and Neutral (N) over resin substrates A1 and A4. Samples were subjected to 20,000 aging thermocycles, alternating 55°C–5°C (30 s). Spectral reflectance was measured using a spectrophotometer (CM‐3700d—Konica Minolta) at four intervals: before aging (t0) and after 10,000 (t10), 15,000 (t15), and 20,000 (t20) cycles. The Translucency Parameter (TP 00 ) and the ΔTP 00 were calculated. The thresholds for translucency perceptibility (TPT 00 ) and acceptability (TAT 00 ) were set at 0.62 and 2.62, respectively. Statistical analysis was performed using four‐way repeated measures ANOVA and Tukey's post hoc test ( α = 0.05). Results: Aging time, ceramic translucency, resin cement color and substrate saturation had a significant effect ( p < 0.001) on TP 00 . While TP 00 values declined across all groups, the lowest values for each measurement moment were consistently observed in the LTL+ groups [1.70 (t0) to 0.90 (t20)]. All ΔTP 00 values remained below the acceptability threshold (TAT = 2.62). Conclusion: Aging resulted in a generalized decrease in translucency across all groups, particularly over lighter substrates and when using chromatic resin cement. However, no clinically unacceptable alterations were observed. Clinical Significance: Clinicians should select materials based on the balance between initial masking and long‐term stability. For dark substrates, LT ceramics ensure consistent optical stability during aging, regardless of the resin cement shade. While combining translucent ceramics (HT/MT) with chromatic resin cements is an effective strategy for initial masking, clinicians must be aware that ceramic translucency is the primary factor controlling the final optical outcome over time.
- Open Access
- 29 July 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 171
Effect of violet and blue light activation on in-office bleaching with 6% hydrogen peroxide: color change, penetration into the pulp chamber and bleaching gel stability
This study evaluated color change, hydrogen peroxide (HP) penetration into the pulp chamber, gel properties, and temperature variation during in-office bleaching with 6% HP combined with different light sources. Sixty extracted sound premolars were randomly allocated into three groups (n = 20): (1) 6% HP without light activation, (2) 6% HP activated by violet light, and (3) 6% HP activated by blue light. Bleaching procedures followed the manufacturers’ recommendations. HP penetration into the pulp chamber was quantified using UV-Vis spectrophotometry. Color change was assessed with a digital spectrophotometer (WI D ). Initial and final HP concentration and pH were determined by titration and a digital pH meter, respectively. Temperature variations during light activation were measured using a thermocouple. Data were analyzed using ANOVA and Tukey’s test (α = 0.05). The 6% HP + violet or blue light groups exhibited lower HP penetration compared with the 6% HP group ( p = 0.02). The 6% HP + violet light group showed higher whitening values compared with the other groups ( p < 0.001). The 6% HP group retained a higher HP concentration ( p = 0.001). Light-irradiated groups exhibited higher temperature variation and greater pH reduction compared with the 6% HP group ( p < 0.001). The violet-light protocol combined with 6% HP resulted in higher whitening values and reduced HP diffusion into the pulp chamber. However, light activation was also associated with increased temperature variation and slight pH reduction, which should be considered when interpreting the biological safety of these protocols.
- 29 July 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 171
Open AccessEffect of violet and blue light activation on in-office bleaching with 6% hydrogen peroxide: color change, penetration into the pulp chamber and bleaching gel stability
This study evaluated color change, hydrogen peroxide (HP) penetration into the pulp chamber, gel properties, and temperature variation during in-office bleaching with 6% HP combined with different light sources. Sixty extracted sound premolars were randomly allocated into three groups (n = 20): (1) 6% HP without light activation, (2) 6% HP activated by violet light, and (3) 6% HP activated by blue light. Bleaching procedures followed the manufacturers’ recommendations. HP penetration into the pulp chamber was quantified using UV-Vis spectrophotometry. Color change was assessed with a digital spectrophotometer (WI D ). Initial and final HP concentration and pH were determined by titration and a digital pH meter, respectively. Temperature variations during light activation were measured using a thermocouple. Data were analyzed using ANOVA and Tukey’s test (α = 0.05). The 6% HP + violet or blue light groups exhibited lower HP penetration compared with the 6% HP group ( p = 0.02). The 6% HP + violet light group showed higher whitening values compared with the other groups ( p < 0.001). The 6% HP group retained a higher HP concentration ( p = 0.001). Light-irradiated groups exhibited higher temperature variation and greater pH reduction compared with the 6% HP group ( p < 0.001). The violet-light protocol combined with 6% HP resulted in higher whitening values and reduced HP diffusion into the pulp chamber. However, light activation was also associated with increased temperature variation and slight pH reduction, which should be considered when interpreting the biological safety of these protocols.
- 4 December 2025
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 146
Effect of delivery mode on bond strength of a self-adhesive resin cement
- 4 December 2025
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 146
Effect of delivery mode on bond strength of a self-adhesive resin cement
- Open Access
- 30 October 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 62 (5) , 779-782
Laminate veneers phenomena: Esthetics above biology and function?
Indirect laminate veneers can deliver excellent esthetic results, but their use must remain secondary to biological and functional principles, requiring an ethical and evidence-based approach during treatment planning.
- 30 October 2025
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 62 (5) , 779-782
Open AccessLaminate veneers phenomena: Esthetics above biology and function?
Indirect laminate veneers can deliver excellent esthetic results, but their use must remain secondary to biological and functional principles, requiring an ethical and evidence-based approach during treatment planning.
- 6 January 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (4) , 357-365
Impact of the resin cement opacity on the final color of conservative ceramic restorations and on its ability to mask substrates of different saturations
- 6 January 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (4) , 357-365
Impact of the resin cement opacity on the final color of conservative ceramic restorations and on its ability to mask substrates of different saturations
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e017
Aging and post-polymerization effects on conversion degree and properties of additive splint materials
The study objective was to analyze dimensional change, flexural strength, surface hardness, wear profile, and conversion degree of different additive splint materials under various post-polymerization conditions of time and artificial aging. Two additive manufacturing systems (Cara Print 4.0, Dima Print Ortho, Kulzer; SprintRay Pro, SprintRay Splint, SprintRay), and a thermally activated resin control (Clássico) were evaluated in artificial aging (deionized water or saliva; 28 or 84 days at 37°C), with recommended or doubled post-polymerization cycles. Dimensional change (surface metrology), flexural strength (ISO 20795-1:2013), fractography (SEM), Knoop hardness, two-body wear profilometry (150,000 cycles; 3mmØ; 20N; 2.1Hz), and conversion degree (FTIR spectroscopy) were assessed. Two-way ANOVA and post-hoc Tukey tests were used for parametric data, and Kruskal-Wallis and post-hoc Dunn tests, for non-parametric data (α = 0.05). Results indicated no statistically significant differences in dimensional change or flexural strength among the materials. Recommended post-polymerization cycles resulted in lower hardness for additive resins than the thermally activated control. Doubling post-polymerization time significantly increased flexural strength and hardness of Dima Print Ortho, but decreased flexural strength of SprintRay Splint, and did not affect wear resistance. Dima Print Ortho demonstrated the highest wear resistance. Artificial aging did not affect flexural strength, surface wear, or dimensional change, but negatively impacted the hardness of all materials except Dima Print Ortho. The conversion degree was unaffected by post-polymerization time, and no significant differences were found among the materials. Overall, additive materials exhibited mechanical and dimensional properties comparable to thermally activated resin, with doubling post-polymerization time positively influencing the properties.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e017
Open AccessAging and post-polymerization effects on conversion degree and properties of additive splint materials
The study objective was to analyze dimensional change, flexural strength, surface hardness, wear profile, and conversion degree of different additive splint materials under various post-polymerization conditions of time and artificial aging. Two additive manufacturing systems (Cara Print 4.0, Dima Print Ortho, Kulzer; SprintRay Pro, SprintRay Splint, SprintRay), and a thermally activated resin control (Clássico) were evaluated in artificial aging (deionized water or saliva; 28 or 84 days at 37°C), with recommended or doubled post-polymerization cycles. Dimensional change (surface metrology), flexural strength (ISO 20795-1:2013), fractography (SEM), Knoop hardness, two-body wear profilometry (150,000 cycles; 3mmØ; 20N; 2.1Hz), and conversion degree (FTIR spectroscopy) were assessed. Two-way ANOVA and post-hoc Tukey tests were used for parametric data, and Kruskal-Wallis and post-hoc Dunn tests, for non-parametric data (α = 0.05). Results indicated no statistically significant differences in dimensional change or flexural strength among the materials. Recommended post-polymerization cycles resulted in lower hardness for additive resins than the thermally activated control. Doubling post-polymerization time significantly increased flexural strength and hardness of Dima Print Ortho, but decreased flexural strength of SprintRay Splint, and did not affect wear resistance. Dima Print Ortho demonstrated the highest wear resistance. Artificial aging did not affect flexural strength, surface wear, or dimensional change, but negatively impacted the hardness of all materials except Dima Print Ortho. The conversion degree was unaffected by post-polymerization time, and no significant differences were found among the materials. Overall, additive materials exhibited mechanical and dimensional properties comparable to thermally activated resin, with doubling post-polymerization time positively influencing the properties.
- Open Access
- 21 October 2024
- Published by IntechOpen
Color Effects in Dental Ceramic Laminate Veneers
We live in the esthetic age, and dentistry is no exception. The pursuit of the perfect smile is a constant in today’s society, and ceramic veneers are among the most commonly performed treatments. With the trend toward minimally invasive dentistry, these veneers are becoming more conservative, with thicknesses less than 0.5 mm. To perform such treatments, the ceramic restorative material must adhere to a dental substrate using a bonding agent. Each of these individual factors, which together form a restorative system, has different optical characteristics that will influence the final color of the restoration. For ceramics, the type, microstructure, thickness, translucency, and color need to be analyzed beforehand. For the dental substrate, saturation and tissue type (dentin or enamel) will have an impact; and for the bonding agent, its color, translucency/opacity, brand, thickness, internal composition, and color changes with aging will be important considerations. This chapter is aimed at clinicians who seek to make esthetic restorative planning for ceramic veneers more precise, meet patient expectations, and successfully navigate the challenges of complex cases. Here, we present the variables involving the optical and color effects that influence conservative ceramic restorations and their behavior in terms of longevity and esthetic maintenance. Enjoy!
- 21 October 2024
- Published by IntechOpen
Open AccessColor Effects in Dental Ceramic Laminate Veneers
We live in the esthetic age, and dentistry is no exception. The pursuit of the perfect smile is a constant in today’s society, and ceramic veneers are among the most commonly performed treatments. With the trend toward minimally invasive dentistry, these veneers are becoming more conservative, with thicknesses less than 0.5 mm. To perform such treatments, the ceramic restorative material must adhere to a dental substrate using a bonding agent. Each of these individual factors, which together form a restorative system, has different optical characteristics that will influence the final color of the restoration. For ceramics, the type, microstructure, thickness, translucency, and color need to be analyzed beforehand. For the dental substrate, saturation and tissue type (dentin or enamel) will have an impact; and for the bonding agent, its color, translucency/opacity, brand, thickness, internal composition, and color changes with aging will be important considerations. This chapter is aimed at clinicians who seek to make esthetic restorative planning for ceramic veneers more precise, meet patient expectations, and successfully navigate the challenges of complex cases. Here, we present the variables involving the optical and color effects that influence conservative ceramic restorations and their behavior in terms of longevity and esthetic maintenance. Enjoy!
- 24 September 2019
- Published by Editora e Distribuidora Educacional in Journal of Health Sciences
- Vol. 21 (3) , 284-289
Microhardness, Color Stability and Microstructural Analysis of Prefabricated Composite Resin Veneers
The aim of the work was to determine Knoop microhardness (KH), color stability (ΔE00) and microstructure of prefabricated composite resin veneers (PCRVs). Two PCRVs systems (Componeer Brilliant New Generation, Coltene, Altstätten, Switzerland; and Direct Veneer, Edelweiss, Wolfurt, Austria) were tested. KH was measured at the buccal surface of the PCRVs. Color analyze was evaluated by a spectrophotometer and ΔE00 calculated using CIEDE2000 formula. Microstructure of the PCRVs was characterized using scanning electron microscopy (SEM). Data of KH and ΔE00 were subjected to One-way ANOVA followed by Tukey post hoc test (α=0.05). Componeer (KH = 46) and Edelweiss (KH = 43) presented statistical similar hardness results (p>0.05). Componeer (ΔE00water= 0.1 and ΔE00coffee= 13.4) showed lower ΔE00 than Edelweiss (ΔE00water= 0.5 and ΔE00coffee= 18.7). SEM-images indicated similar microstructures of the PCRVs tested. Although PCRVs present similar microhardness and microstructure, Componeer showed higher color stability and lower extrinsic pigmentation to coffee in comparison to Edelweiss. Direct composite resin veneer treatment might be simplified with PCRVs. However, the high pigmentation observed in the PCRVs could generate aesthetic failures over the time.Keywords: Microscopy, Electron, Scanning. Color. Dental Veneers.ResumoO objetivo do trabalho foi determinar a microdureza Knoop (KH), estabilidade de cor (ΔE00) e a microestrutura de facetas de resina composta pré-fabricadas. Os sistemas de facetas Componeer e Edelweiss foram testados. Para cada sistema, a microdureza foi avaliada na superfície vestibular das facetas. A análise da estabilidade de cor foi feita mediante o emprego de um espectrofotômetro e a alteração de cor foi calculada seguindo a fórmula determinada pelo CIEDE2000. A microestrutura dos sistemas foi observada e caracterizada a partir de um microscópio eletrônico de varredura. Os resultados de microdureza e alteração de cor foram submetidos a análise de variância de um fator complementados pelo teste de Tukey (α=0,05). Os sistemas de facetas pré-fabricadas de resina composta apresentaram valores estatisticamente similares de microdureza (p>0,05). O grupo Componeer apresentou uma alteração de cor inferior em relação ao grupo Edelweiss. Os dois sistemas apresentaram uma elevada pigmentação após imersão em solução com café. A microestrutura dos sistemas se mostrou similar em função da avaliação das imagens em microscopia. Apesar dos sistemas apresentarem microdureza e microestrutura similares, o sistema Componeer gerou menor alteração de cor com menor pigmentação a bebida corante empregada em comparação ao sistema Edelweiss. A técnica de facetas dentárias pode ser simplificada utilizando um sistema de facetas pré-fabricadas de resina composta. Todavia, a elevada pigmentação observada no presente estudo deve ser levada em consideração já que o tratamento com esse tipo faceta tende a ser um procedimento estético com durabilidade elevada.Palavras-chaves: Microscopia Eletrônica de Varredura. Cor. Facetas Dentárias.
- 24 September 2019
- Published by Editora e Distribuidora Educacional in Journal of Health Sciences
- Vol. 21 (3) , 284-289
Microhardness, Color Stability and Microstructural Analysis of Prefabricated Composite Resin Veneers
The aim of the work was to determine Knoop microhardness (KH), color stability (ΔE00) and microstructure of prefabricated composite resin veneers (PCRVs). Two PCRVs systems (Componeer Brilliant New Generation, Coltene, Altstätten, Switzerland; and Direct Veneer, Edelweiss, Wolfurt, Austria) were tested. KH was measured at the buccal surface of the PCRVs. Color analyze was evaluated by a spectrophotometer and ΔE00 calculated using CIEDE2000 formula. Microstructure of the PCRVs was characterized using scanning electron microscopy (SEM). Data of KH and ΔE00 were subjected to One-way ANOVA followed by Tukey post hoc test (α=0.05). Componeer (KH = 46) and Edelweiss (KH = 43) presented statistical similar hardness results (p>0.05). Componeer (ΔE00water= 0.1 and ΔE00coffee= 13.4) showed lower ΔE00 than Edelweiss (ΔE00water= 0.5 and ΔE00coffee= 18.7). SEM-images indicated similar microstructures of the PCRVs tested. Although PCRVs present similar microhardness and microstructure, Componeer showed higher color stability and lower extrinsic pigmentation to coffee in comparison to Edelweiss. Direct composite resin veneer treatment might be simplified with PCRVs. However, the high pigmentation observed in the PCRVs could generate aesthetic failures over the time.Keywords: Microscopy, Electron, Scanning. Color. Dental Veneers.ResumoO objetivo do trabalho foi determinar a microdureza Knoop (KH), estabilidade de cor (ΔE00) e a microestrutura de facetas de resina composta pré-fabricadas. Os sistemas de facetas Componeer e Edelweiss foram testados. Para cada sistema, a microdureza foi avaliada na superfície vestibular das facetas. A análise da estabilidade de cor foi feita mediante o emprego de um espectrofotômetro e a alteração de cor foi calculada seguindo a fórmula determinada pelo CIEDE2000. A microestrutura dos sistemas foi observada e caracterizada a partir de um microscópio eletrônico de varredura. Os resultados de microdureza e alteração de cor foram submetidos a análise de variância de um fator complementados pelo teste de Tukey (α=0,05). Os sistemas de facetas pré-fabricadas de resina composta apresentaram valores estatisticamente similares de microdureza (p>0,05). O grupo Componeer apresentou uma alteração de cor inferior em relação ao grupo Edelweiss. Os dois sistemas apresentaram uma elevada pigmentação após imersão em solução com café. A microestrutura dos sistemas se mostrou similar em função da avaliação das imagens em microscopia. Apesar dos sistemas apresentarem microdureza e microestrutura similares, o sistema Componeer gerou menor alteração de cor com menor pigmentação a bebida corante empregada em comparação ao sistema Edelweiss. A técnica de facetas dentárias pode ser simplificada utilizando um sistema de facetas pré-fabricadas de resina composta. Todavia, a elevada pigmentação observada no presente estudo deve ser levada em consideração já que o tratamento com esse tipo faceta tende a ser um procedimento estético com durabilidade elevada.Palavras-chaves: Microscopia Eletrônica de Varredura. Cor. Facetas Dentárias.
- 8 July 2017
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (2) , 961-970
Micro-CT and FE-SEM enamel analyses of calcium-based agent application after bleaching
- 8 July 2017
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (2) , 961-970
Micro-CT and FE-SEM enamel analyses of calcium-based agent application after bleaching