LSLucas Soustelle

Lucas Soustelle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lucas Soustelle has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Open Test–Retest Dataset of Rapid Myelin Mapping Acquisitions

    by Steven L. Meisler, Taylor Salo, Matthew Cieslak, Brooke L. Sevchik, Juliette Brook, Guillaume Duhamel, Olivier M. Girard, Bart Larsen, Shraddha Pandey, Lucinda M. Sisk, et al.

    Myelin supports rapid and efficient neural communication and is implicated in brain development, learning, aging, and neurological disease. Although numerous magnetic resonance imaging (MRI) approaches have been proposed to characterize myelin in vivo, they have rarely been evaluated together within the same participants and across repeated acquisitions. To address these gaps, we introduce the Myelin Imaging Reliability and ReprOducibility Resource (MIRROR), an openly available multimodal test– retest MRI dataset of diffusion MRI (dMRI), inhomogeneous magnetization transfer imaging (ihMT), quantitative susceptibility mapping (QSM), MP2RAGE, T 1 w/T 2 w ratio mapping, and transverse relaxometry in 22 healthy adults. We evaluated gray–white matter differentiation, intermetric correspondence, test–retest reliability, and participant specificity across 27 myelin-sensitive metrics. Gray–white matter differentiation was strong for dMRI derivatives, MP2RAGE-derived R 1 , T 1 w/T 2 w, and ihMT, while being substantially weaker for QSM measures. Intermetric spatial correlations were generally strongest within acquisition or modeling families. Test–retest reliability was generally high, particularly for dMRI-derived metrics, but was more variable among QSM-, ihMT-, and R 2 *-derived measures. Regional spatial profiles were also highly participant-specific, with discriminability approaching its upper bound for most metrics. All imaging data, derived maps, and processing code are openly released. MIRROR provides a benchmark for characterizing the measurement properties and practical tradeoffs of scalable myelin-sensitive MRI methods, supporting principled acquisition selection and accelerating methodological development and validation.

  • Open Access

    SNR ‐Efficient Inhomogeneous Magnetization Transfer ( ihMT ) for Clinical Applications at 7 T

    by Timothy Anderson, Niklas Wallstein, Lucas Soustelle, Thomas Troalen, Gopal Varma, David C. Alsop, Maxime Guye, Guillaume Duhamel, Olivier M. Girard

    Purpose: Inhomogeneous MT (ihMT) is an MRI modality sensitive to Myelin, the lipid‐rich membrane surrounding the axons. A novel ihMT saturation strategy and its associated correction at UHF are proposed. The aim is to generate a strong ihMT effect within a clinically compatible scan time while complying with SAR constraints at 7 T. Methods: The MT preparation module of the proposed approach was shortened, reducing power deposition and allowing for shorter scan time while maximizing SNR efficiency. Optimization of the sequence was validated on (2 mm iso.) on a 7 T clinical scanner. Example high resolution images were acquired (1–1.4 mm iso.). Model‐based corrections were applied and their impact on ihMT quantification was studied. Numerical simulations and error quantifications were performed to complement experimental data. Results: Fewer bursts () of cosine‐modulated MT preparation pulses () performed at maximal yielded strong ihMT signal with better SNR efficiency as compared to previously proposed long saturation trains (). correction showed a reliability range () which challenged applicability in strong hypo‐intense areas. High resolution acquisitions showed acceptable SNR () for resolutions down to 1 mm iso., enabling studies of fine structures (e.g., deep gray nuclei) with added specificity provided by ihMT. Conclusion: ihMT applications at 7 T are enabled. While whole‐brain imaging requires further work to compensate for inhomogeneities, localized applications (e.g., Thalamus) are immediately feasible within clinically compatible scan time (< min). Similar sequence improvements are expected at lower field strengths (e.g., ).

  • Open Access

    Structural Characterization of Cardiac Free‐Running Purkinje Fibers Using Inhomogeneous Magnetization Transfer (ihMT): A Proof of Concept MRI‐Histology Approach

    by Arash Forodighasemabadi, Evgenios N. Kornaropoulos, Marion Constantin, Lucas Soustelle, Fanny Vaillant, Jude Leury, Richard Walton, Olivier Bernus, Bruno Quesson, Olivier M. Girard, et al.

    The cardiac Purkinje network plays a critical role in maintaining synchronized ventricular activation but remains difficult to image due to its fine and complex structure. Conventional MRI techniques lack sufficient contrast to distinguish the structural composition of Purkinje fibers (PFs). This study investigates the potential of inhomogeneous magnetization transfer (ihMT) as a novel contrast mechanism for visualizing and differentiating subregions of the Purkinje network. Five fixed ex vivo sheep hearts containing free‐running PFs were scanned using a 9.4 T MRI system with a 2D ihMT RARE sequence. ihMTR maps were analyzed using manually defined regions of interest (ROIs) corresponding to free‐running fibers, the Purkinje–myocardial junction (PMJ), and the surrounding myocardium. Histological analysis was performed on matched tissue sections to quantify collagen types I and III, adipocytes, Purkinje cells, and cardiomyocytes. Three ihMT protocols that produced high ihMTR values in free‐running fibers (9.25–10.83%) and strong contrast relative to myocardium (2.00–2.17%) and the PMJ (2.99–3.40%) in 1 sample were selected and applied to all samples. Across all hearts, mean ihMTR values were consistently higher in free‐running fibers compared to the PMJ (11.5 ± 1.5% vs 9.0 ± 2.9%). Histological analysis revealed significantly greater collagen content in free‐running regions compared with the PMJ (72.4 ± 15.9% vs 31.1 ± 13.1%; p = 0.001), along with higher adipocyte content at the PMJ compared to free‐running regions (12.3 ± 6.1% vs 3.8 ± 2.7%, not significant). Collagen type III was more prominent at the PMJ but remained a minor component overall. These findings demonstrate that ihMT imaging can distinguish PF subregions based on underlying microstructural differences, particularly collagen and adipocyte distribution. This study lays the groundwork for developing biophysical models to interpret ihMT signals in terms of tissue composition and microstructure, providing a foundation for future studies.


  • Myelin imaging in MRI using ultra-short echo time sequences

    by Lucas Soustelle

    Imagerie de la myéline par IRM à temps d'écho ultracourt: L'évaluation non-invasive de la myéline dans la substance blanche du système nerveux central est fondamentale pour le suivi de pathologies telles que la sclérose en plaques. La myéline est majoritairement constituée de lipides et de protéines : du fait des nombreuses interactions dans ces macromolécules, les temps de relaxation transversale sont très courts (T2 < 1 ms), rendant indétectables ces signaux par des séquences conventionnelles. Les méthodes standards d’imagerie par RMN pour la caractérisation de la myéline reposent sur la modélisation des interactions entre les protons aqueux et la structure myélinisée. Néanmoins, la sélectivité et la robustesse de ces méthodes indirectes peuvent être remises en cause. Les séquences à temps d’écho ultracourt (UTE – TE < 1 ms) permettraient de faire l’acquisition directe des signaux issus de la matrice semi-solide de la myéline. Le développement de telles méthodes pour la mise en contraste positif et sélectif de la myéline sur système préclinique est l’objet de cette thèse. La validation de chacune des méthodes a été menée sur modèle murin ex vivo en confrontant des animaux sains et démyélinisés. Les résultats à partir des méthodes UTE montrent une sélectivité significative à la démyélinisation, suggérant l’adéquation de la technique pour l'évaluation de la myéline dans la substance blanche.

  • Open Access

    Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations

    by Gopal Varma, Aaron K. Grant, Lucas Soustelle, Olivier M. Girard, Guillaume Duhamel, David C. Alsop

    Purpose: To evaluate Frequency Alternation at Low duty cycle for Single Offset (FALSO) as a novel Magnetization Transfer (MT) preparation scheme to increase speed and/or spatial resolution of inhomogeneous MT (ihMT) MRI by reducing the number of volumes required. Methods: We compared FALSO MT to standard single frequency MT preparations using signal simulations and ihMT data acquired in a rat brain at 9.4 T and human brains at 3 T. Using FALSO MT preparations, combined with optimized Variable Flip Angle (VFA) MPRAGE readouts, we also acquired ihMT data at high resolution (down to 1.4 mm isotropic) to demonstrate the reduction in acquisitions required for ihMT images of sufficient SNR. Results: We found no statistically significant difference between ihMT ratios from data acquired using FALSO MT preparations versus averaging data following separate positive and negative frequency offset MT acquisitions (as in regular ihMT to account for MT asymmetry). Use of VFA (relative to constant flip angle) readouts allowed high‐resolution ihMT images with a minimal number of volumes to be acquired and reduced variance in ihMT ratios within ROIs. Conclusion: FALSO MT preparations allow for a reduction in the number of acquisitions required for ihMT while still controlling for MT asymmetry. IhMT data acquired with VFA readouts allow for higher resolution acquisitions in the same scan time. The combination of FALSO MT and VFA readouts can be used to increase the spatial and/or temporal resolution of ihMT experiments, allowing for easier clinical translation and improving the utility of ihMT in neurological studies of myelin.

  • Open Access

    Ultrasound and MRI Are Not Interchangeable for Measuring Muscle Cross‐Sectional Area: Analysis of Reliability and Validity in 10 Lower Limb Muscles Considering Sex Differences

    by Yoko Kunimasa, Robin Macchi, Caroline Nicol, Baptiste Corcelle, Constance P. Michel, Marc‐Adrien Hostin, Lucas Soustelle, David Bendahan

    Ultrasound‐based anatomical cross‐sectional area (US‐ACSA) measurement using extended‐field‐of‐view (EFOV) imaging offers a practical alternative to magnetic resonance imaging (MRI‐ASCA) measurements. Although its reliability and validity have previously been assessed, previous studies have focused only on a single or limited number of muscles with little attention to effects of muscle size and sex. This study was conducted in ten lower limb muscles of varying sizes in males and females in order to assess the reliability and validity of US‐ACSA measurements using MRI as the gold standard method. Twelve males and twelve females participated in this study. US‐ and MRI‐ACSA were measured twice, one day apart. Reliability was assessed using intraclass correlation coefficients (ICC 2,3 ), standard error of measurement (SEM) and minimal detectable change (MDC). Validity was examined using Pearson product‐moment correlation and Bland–Altman analysis. A linear model was used to evaluate the effects of muscle size and sex. ICC 2,3 , SEM and MDC ranged from 0.992% to 0.999%, 0.50%–1.90% and 1.25%–5.36% for US‐ACSA and from 0.952% to 0.998%, 0.90%–4.76% and 2.51%–13.19% for MRI‐ACSA. US‐ACSA showed strong correlations with MRI‐ACSA ( r = 0.73–0.95). A systematic underestimation of MRI values (relative bias: −11.5% to −23.7%) was identified, with no systematic effect of muscle size or sex. These findings suggest that US‐ACSA measurements of lower limb muscles are highly reliable regardless of muscle size and sex. However, due to the large systematic bias, US‐ and MRI‐based ACSAs measurements are not interchangeable.


  • Open Access

    Structural Characterization of Cardiac Purkinje Fibers Using Inhomogeneous Magnetization Transfer (ihMT): A proof of Concept MRI-Histology Approach

    by Arash Forodighasemabadi, Evgenios N. Kornaropoulos, Marion Constantin, Lucas Soustelle, Fanny Vaillant, Jude Leury, Richard Walton, Olivier Bernus, Bruno Quesson, Olivier M. Girard, et al.

    BACKGROUND: The cardiac Purkinje network plays a critical role in maintaining synchronized activation of ventricles but remains challenging to image due to its fine and unique structure. Conventional MRI techniques lack sufficient contrast to distinguish the underlying structural composition of Purkinje Fibers (PF). PURPOSE: This study investigates the potential of inhomogeneous Magnetization Transfer (ihMT) as a novel contrast mechanism for visualizing and differentiating subregions of the PF. METHODS: Five fixed ex-vivo sheep hearts (n = 5) containing free running PF were scanned with a 9.4T MRI using a 2D ihMT RARE sequence. ASSESSMENT: ihMTR maps were analyzed using manually defined regions-of-interest (ROIs) corresponding to free-running PF, insertion points, and myocardium. Histological analysis (light and polarized microscopy) was performed on matched sections to quantify collagen types I and III, adipocytes, Purkinje cells, and cardiomyocytes. RESULTS: Three ihMT protocols, which produced high ihMTR values in free-running PF (9.25–10.83%) and strong absolute contrast relative to the myocardium (2.00–2.17%) and insertion points (2.99–3.40%) in one sample were selected and applied to all samples. Across all samples, mean ihMTR in free-running was consistently higher than in insertion points (11.5 ± 1.5% vs. 9.0 ± 2.9%). Histological analysis revealed a significantly greater collagen content in free-running regions compared with insertion points (72.4 ± 15.9% vs. 31.1 ± 13.1%; p = 0.001), along with higher adipocyte content at insertion points vs. free-running regions (12.3 ± 6.1% vs. 3.8 ± 2.7%, non-significant). Collagen type III was more prominent at insertion points but remained a minor component overall. CONCLUSION: ihMT imaging can distinguish PF subregions based on microstructural differences, particularly collagen and adipocyte distribution. This study lays the groundwork for developing biophysical models to interpret ihMT signals in terms of tissue composition and microstructure, providing a foundation for future studies. Sponsor: This study received financial support from the French Government by the National Research Agency (ANR; SYNATRA ANR-21-CE19-0014-01) and Région Nouvelle Aquitaine (convention N°AAPR2022-2021-16609210).

  • Open Access

    Neuromelanin Contrast Optimization and Improved Visualization of the Substantia Nigra in a 3D Gradient‐Echo Sequence With Magnetization Transfer

    by Begoña Garate Andikoetxea, Antonio Martín‐Bastida, Marta Vidorreta, María Cruz Rodríguez‐Oroz, Lucas Soustelle, Thomas Troalen, Maria A. Fernández‐Seara

    Neuromelanin (NM) magnetic resonance imaging has been used to evaluate the loss of melanized neurons in the substantia nigra, the main characteristic of Parkinson disease, typically by measuring the contrast ratio (CR) between the NM‐rich areas and the cerebral peduncles in the midbrain. Neuromelanin contrast can be generated by employing a 3D gradient‐echo (GRE) sequence with magnetization transfer (MT). In this work, we first evaluated the effect of the MT pulse frequency on the CR and contrast‐to‐noise ratio (CNR), analyzing a large frequency range from 500 to 100K Hz. Secondly, the impact of the 3D GRE sequence flip angle (FA) was evaluated using angles from 5° to 40°. Additionally, images were acquired both with and without MT for each FA, providing an opportunity to examine the effect of MT on tissue proton density, T1, and T2* values. Results showed that the highest CR and CNR were obtained for the lower MT frequencies (500–2000 Hz) and lower FAs (5°–10°). The lower FAs improved the visualization of the neuromelanin‐rich area in the substantia nigra and facilitated delineating its volume. In addition, this work showed that the MT pulse decreased the T1 and PD of the tissue. Furthermore, simulations supported the obtained in vivo results.


  • Open Access

    Quantitative magnetization transfer MRI unbiased by on‐resonance saturation and dipolar order contributions

    by Lucas Soustelle, Thomas Troalen, Andreea Hertanu, Jean‐Philippe Ranjeva, Maxime Guye, Gopal Varma, David C. Alsop, Guillaume Duhamel, Olivier M. Girard

    Purpose: To demonstrate the bias in quantitative MT (qMT) measures introduced by the presence of dipolar order and on‐resonance saturation (ONRS) effects using magnetization transfer (MT) spoiled gradient‐recalled (SPGR) acquisitions, and propose changes to the acquisition and analysis strategies to remove these biases.Methods: The proposed framework consists of SPGR sequences prepared with simultaneous dual‐offset frequency‐saturation pulses to cancel out dipolar order and associated relaxation (T1D) effects in Z‐spectrum acquisitions, and a matched quantitative MT (qMT) mathematical model that includes ONRS effects of readout pulses. Variable flip angle and MT data were fitted jointly to simultaneously estimate qMT parameters (macromolecular proton fraction [MPF], T2,f, T2,b, R, and free pool T1). This framework is compared with standard qMT and investigated in terms of reproducibility, and then further developed to follow a joint single‐point qMT methodology for combined estimation of MPF and T1.Results: Bland–Altman analyses demonstrated a systematic underestimation of MPF (−2.5% and −1.3%, on average, in white and gray matter, respectively) and overestimation of T1 (47.1 ms and 38.6 ms, on average, in white and gray matter, respectively) if both ONRS and dipolar order effects are ignored. Reproducibility of the proposed framework is excellent (ΔMPF = −0.03% and ΔT1 = −19.0 ms). The single‐point methodology yielded consistent MPF and T1 values with respective maximum relative average bias of −0.15% and −3.5 ms found in white matter.Conclusion: The influence of acquisition strategy and matched mathematical model with regard to ONRS and dipolar order effects in qMT‐SPGR frameworks has been investigated. The proposed framework holds promise for improved accuracy with reproducibility.


  • Open Access

    Inhomogeneous Magnetization Transfer (ihMT) imaging in the acute cuprizone mouse model of demyelination/remyelination

    by Andreea Hertanu, Lucas Soustelle, Julie Buron, Julie Le Priellec, Myriam Cayre, Arnaud Le Troter, Valentin H. Prevost, Jean-Philippe Ranjeva, Gopal Varma, David C. Alsop, et al.