KKKyung-Min Kang

Kyung-Min Kang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyung-Min Kang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Operation Method of Hybrid Power Supply System Combining Lithium Polymer Battery and Supercapacitor for Industrial Drones

    by Kyung-Min Kang, Young-Sang Ko, Yoon-Seong Lee, Junsin Yi, Chung-Yuen Won

    This paper proposes a hybrid power supply system for commercial drones. The proposed hybrid power supply system consists of a lithium polymer battery, a supercapacitor, and a power converter for charging the supercapacitor. In the proposed system, the supercapacitor is pre-charged with a lithium polymer battery through a power converter, and the supercapacitor first supplies the power required for the drone’s initial startup and lift-up. Afterward, in the section where the power consumption of the drone is low, the battery and the supercapacitor supply power together, minimizing the stress on the battery. To verify the proposed hybrid power supply system, a computer simulation was conducted, the actual hardware was fabricated, and experiments were performed.


  • Open Access

    Energy Management Method of Hybrid AC/DC Microgrid Using Artificial Neural Network

    by Kyung-Min Kang, Bong-Yeon Choi, Hoon Lee, Chang-Gyun An, Tae-Gyu Kim, Yoon-Seong Lee, Mina Kim, Junsin Yi, Chung-Yuen Won

    This paper proposes an artificial neural network (ANN)-based energy management system (EMS) for controlling power in AC–DC hybrid distribution networks. The proposed ANN-based EMS selects an optimal operating mode by collecting data such as the power provided by distributed generation (DG), the load demand, and state of charge (SOC). For training the ANN, profile data on the charging and discharging amount of ESS for various distribution network power situations were prepared, and the ANN was trained with an error rate within 10%. The proposed EMS controls each power converter in the optimal operation mode through the already trained ANN in the grid-connected mode. For the experimental verification of the proposed EMS, a small-scale hybrid AD/DC microgrid was fabricated, and simulations and experiments were performed for each operation mode.


  • Open Access

    Energy Management System of DC Microgrid in Grid-Connected and Stand-Alone Modes: Control, Operation and Experimental Validation

    by Hoon Lee, Jin-Wook Kang, Bong-Yeon Choi, Kyung-Min Kang, Mi-Na Kim, Chang-Gyun An, Junsin Yi, Chung-Yuen Won

    This paper proposes an energy management system (EMS) of direct current (DC) microgrid. In order to implement the proposed EMS, the control and operation method of EMS is presented in this work. While most of the studies have individually examined the grid-connected mode used in building and the stand-alone operation mode applicable to the island, the proposed EMS allows it to be used in both grid-connected mode and stand-alone mode with 10 modes. In order to determine each mode in EMS, not only the amount of generated power, load power, and the state of charge (SOC) of the battery, but also the rated power of the energy storage system (ESS) converter that performs charging and discharging operations is additionally considered. Thus, various uncertainties that may occur in the actual DC microgrid environment can be improved. A laboratory-scale DC microgrid is fabricated to conduct experimental validation of proposed EMS. Experiments of DC microgrid with proposed EMS were performed for each mode, and the experiment waveforms of each power conversion device are included in detail.


  • Open Access

    A Study on Stability Control of Grid Connected DC Distribution System Based on Second Order Generalized Integrator-Frequency Locked Loop (SOGI-FLL)

    by Jin-Wook Kang, Ki-Woong Shin, Hoon Lee, Kyung-Min Kang, Jintae Kim, Chung-Yuen Won

    This paper studies a second order generalized integrator-frequency locked loop (SOGI-FLL) control scheme applicable for 3-phase alternating current/direct current (AC/DC) pulse width modulation (PWM) converters used in DC distribution systems. The 3-phase AC/DC PWM converter is the most important power conversion system of DC distribution, since it can boost 380 Vrms 3-phase line-to-line AC voltage to 700 Vdc DC output with various DC load devices and grid voltages. The direct-quadrature (d-q) transformation, positive sequence voltage extraction, proportional integral (PI) voltage/current control, and phase locked loop (PLL) are necessary to control the 3-phase AC/DC PWM converter. Besides, a digital filter, such as low pass filter and all pass filter, are essential in the conventional synchronous reference frame-phase locked loop (SRF-PLL) method to eliminate the low order harmonics of input. However, they limit the bandwidth of the controller, which directly affects the output voltage and load of 3-phase AC/DC PWM converter when sever voltage fluctuation, such as sag, swell, etc. occurred in the grid. On the other hand, the proposed control method using SOGI-FLL is able to do phase angle detection, positive sequence voltage extraction, and harmonic filtering without additional digital filters, so that more stable and fast transient control is achieved in the DC distribution system. To verify the improvement of the characteristics in the unbalanced voltage and frequency fluctuation of the grid, a simulation and experiment are implemented with 50 kW 3-phase AC/DC PWM converter used in DC distribution.


  • Open Access

    Improvement of Transient State Response through Feedforward Compensation Method of AC/DC Power Conversion System (PCS) Based on Space Vector Pulse Width Modulation (SVPWM)

    by Seok-Jin Hong, Seung-Wook Hyun, Kyung-Min Kang, Jung-Hyo Lee, Chung-Yuen Won

    In a DC distribution system configured by AC/DC power conversion system (PCS), the voltage control performance of the AC/DC PCS determines the stability and reliability of the DC distribution grid. The DC voltage of grid is maintained by capacitor, thus transient voltage is an inevitable problem when a grid is connected with a high amount of load or renewable energy. Space vector pulse width modulation (SVPWM) is well known as a stable modulation method and is used in AC/DC PCS and many types of topologies, but a solution for the transient states issue of DC link has not clearly been studied. In this paper, a feedforward compensation method based on the mathematical model of SVPWM is proposed to solve the transient state problem in a DC distribution system. The proposed method is verified by simulation and experiment. AC/DC PCS with the proposed feedforward compensation method has more robust DC voltage control characteristics.