Peng Yuan
Peng Yuan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chenzhao Fu
State Grid Shanghai Municipal Electrical Power Company, Shanghai 200122, China
6 shared publications - Wenrong Si
State Grid Shanghai Municipal Electrical Power Company, Shanghai 200122, China
6 shared publications - Haoyong Li
Key Laboratory of Micro/Nano Systems for Aerospace (Ministry of Education), Northwestern Polytechnical University, Xi’an 710072, China
4 shared publications - Yiting Yu
School of Mechanical Engineering, Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Key Laboratory of Micro- and Nano-Electro-Mechanical Systems of Shaanxi Province, Northwestern Polytechnical University, 127 Youyi West Road, Xi’an, China
4 shared publications - Delin Li
Key Laboratory of Micro/Nano Systems for Aerospace (Ministry of Education), Northwestern Polytechnical University, Xi’an 710072, China
3 shared publications - Chaoyu Xiong
Key Laboratory of Micro/Nano Systems for Aerospace (Ministry of Education), Northwestern Polytechnical University, Xi’an 710072, China
2 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10174
Numerical Investigation of the Effects of Temperature-Dependent Permittivity and Space-Charge Transport on the Electric-Field Distribution in the Oil–Paper Insulation of an Oil-Immersed Transformer
To investigate the effects of the thermal state under rated operation and space-charge transport on the electric-field distribution in oil–paper insulation, a sequentially coupled multiphysics model is developed for a 30 kVA single-phase three-limb oil-immersed transformer. The non-uniform temperature field is mapped onto transformer oil and insulating paper, and electric-field distributions with constant and temperature-dependent dielectric parameters are compared. Short-term charge-transport calculations and initial space-charge sensitivity analysis are also performed under fixed peak-potential boundary conditions. The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions. In Case 3 (under initially charge-neutral conditions), positive and negative space charges accumulate in the oil regions adjacent to the low- and high-voltage winding ends, respectively, while the space-charge density in the middle of the main insulation oil duct remains near zero. Compared with Case 2 (under temperature-dependent dielectric conditions), the maximum field strengths in oil and paper decrease by 2.14% and 24.58%, respectively. For Cases 3–6, from initially charge-neutral to moderate space-charge conditions, maximum-field variations remain within approximately 5%, whereas Case 7 (highest initial positive-charge condition) shows pronounced field enhancement.
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10174
Open AccessNumerical Investigation of the Effects of Temperature-Dependent Permittivity and Space-Charge Transport on the Electric-Field Distribution in the Oil–Paper Insulation of an Oil-Immersed Transformer
To investigate the effects of the thermal state under rated operation and space-charge transport on the electric-field distribution in oil–paper insulation, a sequentially coupled multiphysics model is developed for a 30 kVA single-phase three-limb oil-immersed transformer. The non-uniform temperature field is mapped onto transformer oil and insulating paper, and electric-field distributions with constant and temperature-dependent dielectric parameters are compared. Short-term charge-transport calculations and initial space-charge sensitivity analysis are also performed under fixed peak-potential boundary conditions. The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions. In Case 3 (under initially charge-neutral conditions), positive and negative space charges accumulate in the oil regions adjacent to the low- and high-voltage winding ends, respectively, while the space-charge density in the middle of the main insulation oil duct remains near zero. Compared with Case 2 (under temperature-dependent dielectric conditions), the maximum field strengths in oil and paper decrease by 2.14% and 24.58%, respectively. For Cases 3–6, from initially charge-neutral to moderate space-charge conditions, maximum-field variations remain within approximately 5%, whereas Case 7 (highest initial positive-charge condition) shows pronounced field enhancement.
- Open Access
Numerical and Experimental Study of Heat Transfer Enhancement for Horizontal Blowing Panel-Type Radiators with Multiple Fans
To improve the thermal performance of air-cooled panel-type radiators for transformers, a multi-fan horizontal blowing method was designed in this paper, and the thermo-hydraulic performance of the oil-side and air-side of the panel-type radiator was investigated with a simplified numerical method and experiments. The uniform air distribution and zoned heat dissipation ideas were used for three blowing methods, which can increase the proportion of air supply for the high-temperature area of the radiator and apply multiple fans for zoned heat dissipation of the insulating oil in the radiator. Then, the effect of different insulating oil flow rates on the heat dissipation performance of the panel-type radiator was investigated. It was shown that the computational time for the simplified numerical simulation method used for an air-cooled panel-type radiator could be effectively shortened with a small relative error. Due to a more uniform air supply and prioritized air distribution for the high-temperature areas using the multi-fan horizontal blowing method, the overall heat dissipation efficiency was improved. Among the three blowing methods, the best heat dissipation performance was obtained by using the six-fan horizontal blowing scheme, which can improve the performance by about 10.42% and 15.44% in experimental and numerical studies, respectively, as compared with the traditional blowing method.
Open AccessNumerical and Experimental Study of Heat Transfer Enhancement for Horizontal Blowing Panel-Type Radiators with Multiple Fans
To improve the thermal performance of air-cooled panel-type radiators for transformers, a multi-fan horizontal blowing method was designed in this paper, and the thermo-hydraulic performance of the oil-side and air-side of the panel-type radiator was investigated with a simplified numerical method and experiments. The uniform air distribution and zoned heat dissipation ideas were used for three blowing methods, which can increase the proportion of air supply for the high-temperature area of the radiator and apply multiple fans for zoned heat dissipation of the insulating oil in the radiator. Then, the effect of different insulating oil flow rates on the heat dissipation performance of the panel-type radiator was investigated. It was shown that the computational time for the simplified numerical simulation method used for an air-cooled panel-type radiator could be effectively shortened with a small relative error. Due to a more uniform air supply and prioritized air distribution for the high-temperature areas using the multi-fan horizontal blowing method, the overall heat dissipation efficiency was improved. Among the three blowing methods, the best heat dissipation performance was obtained by using the six-fan horizontal blowing scheme, which can improve the performance by about 10.42% and 15.44% in experimental and numerical studies, respectively, as compared with the traditional blowing method.
- Open Access
Locating Ultrasonic Signals Employing MEMS-On-Fiber Sensors
Sound sensing finds wide applications in various fields, such as underwater detection, structural health monitoring, and medical diagnosis, to name just a few. Based on our previously developed MEMS-on-fiber sensors, showing the advantages of low cost, small volume, and high performance, a three-dimensional ultrasonic localization system employing four such sensors was established in this work. A time difference of arrival (TDOA) algorithm was utilized to analyze the acquired data and then calculate the accurate position of the ultrasonic signal source. Plenty of practical measurements were performed, and the derived localization deviation in the region of 2 m × 2 m × 1 m was about 2–5 mm. Outside this region, the deviation tended to increase due to the directional sensitivity existing in these sensors. As a result, for a more accurate localization requirement, more sensing probes are needed in order to depict a completely suitable application situation for MEMS technology.
Open AccessLocating Ultrasonic Signals Employing MEMS-On-Fiber Sensors
Sound sensing finds wide applications in various fields, such as underwater detection, structural health monitoring, and medical diagnosis, to name just a few. Based on our previously developed MEMS-on-fiber sensors, showing the advantages of low cost, small volume, and high performance, a three-dimensional ultrasonic localization system employing four such sensors was established in this work. A time difference of arrival (TDOA) algorithm was utilized to analyze the acquired data and then calculate the accurate position of the ultrasonic signal source. Plenty of practical measurements were performed, and the derived localization deviation in the region of 2 m × 2 m × 1 m was about 2–5 mm. Outside this region, the deviation tended to increase due to the directional sensitivity existing in these sensors. As a result, for a more accurate localization requirement, more sensing probes are needed in order to depict a completely suitable application situation for MEMS technology.
- Open Access
Low-Cost, High-Performance Fiber Optic Fabry–Perot Sensor for Ultrasonic Wave Detection
This study describes a novel fiber optic extrinsic Fabry–Perot interferometric (EFPI) ultrasonic sensor comprising a low-cost and high-performance silicon diaphragm. A vibrating diaphragm, 5 μm thick, was fabricated by using the Microelectromechanical Systems (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. The Fabry–Perot (FP) cavity length was solely determined during the manufacturing process of the diaphragm by defining a specific stepped hole on the handling layer of the SOI wafer, which made the assembly of the sensor easier. In addition, the use of cheap and commercially available components and MEMS processing technology in the development of the sensing system, limited the cost of the sensor. The experimental tests showed that the minimum detectable ultrasonic pressure was 1.5 mPa/sqrt(Hz) −0.625 mPa/sqrt(Hz) between 20 kHz and 40 kHz. As a result, this sensor has the potential to successfully detect weak ultrasonic signals.
Open AccessLow-Cost, High-Performance Fiber Optic Fabry–Perot Sensor for Ultrasonic Wave Detection
This study describes a novel fiber optic extrinsic Fabry–Perot interferometric (EFPI) ultrasonic sensor comprising a low-cost and high-performance silicon diaphragm. A vibrating diaphragm, 5 μm thick, was fabricated by using the Microelectromechanical Systems (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. The Fabry–Perot (FP) cavity length was solely determined during the manufacturing process of the diaphragm by defining a specific stepped hole on the handling layer of the SOI wafer, which made the assembly of the sensor easier. In addition, the use of cheap and commercially available components and MEMS processing technology in the development of the sensing system, limited the cost of the sensor. The experimental tests showed that the minimum detectable ultrasonic pressure was 1.5 mPa/sqrt(Hz) −0.625 mPa/sqrt(Hz) between 20 kHz and 40 kHz. As a result, this sensor has the potential to successfully detect weak ultrasonic signals.
- Open Access
Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source.
Open AccessDirectional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source.
- Open Access
A Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection
A novel beam-supported membrane (BSM) structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI) sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs). The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM) structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases), and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR). A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.
Open AccessA Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection
A novel beam-supported membrane (BSM) structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI) sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs). The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM) structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases), and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR). A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.