Chenzhao Fu
Chenzhao Fu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Wenrong Si
State Grid Shanghai Municipal Electrical Power Company, Shanghai 200122, China
10 shared publications - Peng Yuan
Xi’an MaoRong Power Equipment Co., Ltd., Xi’an 710000, China
6 shared publications - Yiting Yu
School of Mechanical Engineering, Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Key Laboratory of Micro- and Nano-Electro-Mechanical Systems of Shaanxi Province, Northwestern Polytechnical University, 127 Youyi West Road, Xi’an, China
5 shared publications - Haoyong Li
Key Laboratory of Micro/Nano Systems for Aerospace (Ministry of Education), Northwestern Polytechnical University, Xi’an 710072, China
4 shared publications - Jian Yang
MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China
4 shared publications - Delin Li
Key Laboratory of Micro/Nano Systems for Aerospace (Ministry of Education), Northwestern Polytechnical University, Xi’an 710072, China
3 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10174
Numerical Investigation of the Effects of Temperature-Dependent Permittivity and Space-Charge Transport on the Electric-Field Distribution in the Oil–Paper Insulation of an Oil-Immersed Transformer
To investigate the effects of the thermal state under rated operation and space-charge transport on the electric-field distribution in oil–paper insulation, a sequentially coupled multiphysics model is developed for a 30 kVA single-phase three-limb oil-immersed transformer. The non-uniform temperature field is mapped onto transformer oil and insulating paper, and electric-field distributions with constant and temperature-dependent dielectric parameters are compared. Short-term charge-transport calculations and initial space-charge sensitivity analysis are also performed under fixed peak-potential boundary conditions. The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions. In Case 3 (under initially charge-neutral conditions), positive and negative space charges accumulate in the oil regions adjacent to the low- and high-voltage winding ends, respectively, while the space-charge density in the middle of the main insulation oil duct remains near zero. Compared with Case 2 (under temperature-dependent dielectric conditions), the maximum field strengths in oil and paper decrease by 2.14% and 24.58%, respectively. For Cases 3–6, from initially charge-neutral to moderate space-charge conditions, maximum-field variations remain within approximately 5%, whereas Case 7 (highest initial positive-charge condition) shows pronounced field enhancement.
- 14 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10174
Open AccessNumerical Investigation of the Effects of Temperature-Dependent Permittivity and Space-Charge Transport on the Electric-Field Distribution in the Oil–Paper Insulation of an Oil-Immersed Transformer
To investigate the effects of the thermal state under rated operation and space-charge transport on the electric-field distribution in oil–paper insulation, a sequentially coupled multiphysics model is developed for a 30 kVA single-phase three-limb oil-immersed transformer. The non-uniform temperature field is mapped onto transformer oil and insulating paper, and electric-field distributions with constant and temperature-dependent dielectric parameters are compared. Short-term charge-transport calculations and initial space-charge sensitivity analysis are also performed under fixed peak-potential boundary conditions. The results show that temperature-dependent dielectric parameters increase the maximum electric-field strength in transformer oil from 0.358 to 0.374 kV/mm and decrease that in insulating paper from 0.568 to 0.541 kV/mm, without shifting the major high-field regions. In Case 3 (under initially charge-neutral conditions), positive and negative space charges accumulate in the oil regions adjacent to the low- and high-voltage winding ends, respectively, while the space-charge density in the middle of the main insulation oil duct remains near zero. Compared with Case 2 (under temperature-dependent dielectric conditions), the maximum field strengths in oil and paper decrease by 2.14% and 24.58%, respectively. For Cases 3–6, from initially charge-neutral to moderate space-charge conditions, maximum-field variations remain within approximately 5%, whereas Case 7 (highest initial positive-charge condition) shows pronounced field enhancement.
- Open Access
Numerical and Experimental Study of Heat Transfer Enhancement for Horizontal Blowing Panel-Type Radiators with Multiple Fans
To improve the thermal performance of air-cooled panel-type radiators for transformers, a multi-fan horizontal blowing method was designed in this paper, and the thermo-hydraulic performance of the oil-side and air-side of the panel-type radiator was investigated with a simplified numerical method and experiments. The uniform air distribution and zoned heat dissipation ideas were used for three blowing methods, which can increase the proportion of air supply for the high-temperature area of the radiator and apply multiple fans for zoned heat dissipation of the insulating oil in the radiator. Then, the effect of different insulating oil flow rates on the heat dissipation performance of the panel-type radiator was investigated. It was shown that the computational time for the simplified numerical simulation method used for an air-cooled panel-type radiator could be effectively shortened with a small relative error. Due to a more uniform air supply and prioritized air distribution for the high-temperature areas using the multi-fan horizontal blowing method, the overall heat dissipation efficiency was improved. Among the three blowing methods, the best heat dissipation performance was obtained by using the six-fan horizontal blowing scheme, which can improve the performance by about 10.42% and 15.44% in experimental and numerical studies, respectively, as compared with the traditional blowing method.
Open AccessNumerical and Experimental Study of Heat Transfer Enhancement for Horizontal Blowing Panel-Type Radiators with Multiple Fans
To improve the thermal performance of air-cooled panel-type radiators for transformers, a multi-fan horizontal blowing method was designed in this paper, and the thermo-hydraulic performance of the oil-side and air-side of the panel-type radiator was investigated with a simplified numerical method and experiments. The uniform air distribution and zoned heat dissipation ideas were used for three blowing methods, which can increase the proportion of air supply for the high-temperature area of the radiator and apply multiple fans for zoned heat dissipation of the insulating oil in the radiator. Then, the effect of different insulating oil flow rates on the heat dissipation performance of the panel-type radiator was investigated. It was shown that the computational time for the simplified numerical simulation method used for an air-cooled panel-type radiator could be effectively shortened with a small relative error. Due to a more uniform air supply and prioritized air distribution for the high-temperature areas using the multi-fan horizontal blowing method, the overall heat dissipation efficiency was improved. Among the three blowing methods, the best heat dissipation performance was obtained by using the six-fan horizontal blowing scheme, which can improve the performance by about 10.42% and 15.44% in experimental and numerical studies, respectively, as compared with the traditional blowing method.
- Open Access
Steady-State Temperature Prediction for Cluster-Laid Tunnel Cables Based on Self-Modeling in Natural Convection
Accurate temperature prediction of the operating tunnel cable is crucial for its safe and efficient function. To achieve a rapid and accurate prediction of the steady-state temperature of the tunnel cable, the self-modeling pattern in natural convection on the cable surface in the rectangular tunnel is investigated, and the self-modeling method for the convective heat transfer coefficient calculation is proposed. A thermal circuit model for single cables is further established to predict the cable core temperature, and the model is extended to predict the cluster-laid cable core temperature based on the combined method. The results show that when the tunnel size is neglected, the maximum relative deviation of the convective heat transfer coefficient between the self-modeling method and the finite element simulation is only 1.78% in the studied cases, indicating that the natural convection on the cable surface approximately satisfies the self-modeling method. Additionally, applying the self-modeling method to the thermal circuit can accurately predict the temperature of the single cable core. Furthermore, for the three-phase four-circuit cable, the maximum deviation between the temperature prediction results and the finite element results is within 2 K in the studied cases, which verifies the predictive accuracy of the combined method for the cluster-laid tunnel cable.
Open AccessSteady-State Temperature Prediction for Cluster-Laid Tunnel Cables Based on Self-Modeling in Natural Convection
Accurate temperature prediction of the operating tunnel cable is crucial for its safe and efficient function. To achieve a rapid and accurate prediction of the steady-state temperature of the tunnel cable, the self-modeling pattern in natural convection on the cable surface in the rectangular tunnel is investigated, and the self-modeling method for the convective heat transfer coefficient calculation is proposed. A thermal circuit model for single cables is further established to predict the cable core temperature, and the model is extended to predict the cluster-laid cable core temperature based on the combined method. The results show that when the tunnel size is neglected, the maximum relative deviation of the convective heat transfer coefficient between the self-modeling method and the finite element simulation is only 1.78% in the studied cases, indicating that the natural convection on the cable surface approximately satisfies the self-modeling method. Additionally, applying the self-modeling method to the thermal circuit can accurately predict the temperature of the single cable core. Furthermore, for the three-phase four-circuit cable, the maximum deviation between the temperature prediction results and the finite element results is within 2 K in the studied cases, which verifies the predictive accuracy of the combined method for the cluster-laid tunnel cable.
- Open Access
- 1 January 2022
- Published by Wiley in Journal of Nanomaterials
- Vol. 2022 (1)
Dynamic Beam Switching by the Highly Sensitive Metasurface Composed of All‐Metallic Split‐Ring Resonators
The development of metasurfaces capable of arbitrarily manipulating electromagnetic waves has created new opportunities for various applications. However, most tunable metasurface devices via different modulation techniques exhibit large fabrication difficulties or narrow bandwidths. Here, we use the all‐metallic split‐ring resonator to design a dynamically tunable metasurface that is highly sensitive to the ambient refractive index and capable of broadband beam switching. Different from the previous optical scatters, the split‐ring resonator is put on the metal substrate. Due to the existence of metallic substrate and large interaction of corner modes, the proposed resonator has small ohmic loss and high sensitivity to the ambient refractive index. By arraying the all‐metallic split‐ring resonators with different parameters, dynamic beam switching of anomalous reflection is demonstrated numerically. In particularly, the designed metasurface exhibits the dynamic beam switching in a broadband wavelength range of Δλ≈100 nm. Such an all‐metallic metasurface with high sensitivity can greatly reduce the designing difficulty of the tunable optical devices. The dynamic metadevices may find potential applications in stealth camouflage, information encryption, and data storage.
- 1 January 2022
- Published by Wiley in Journal of Nanomaterials
- Vol. 2022 (1)
Open AccessDynamic Beam Switching by the Highly Sensitive Metasurface Composed of All‐Metallic Split‐Ring Resonators
The development of metasurfaces capable of arbitrarily manipulating electromagnetic waves has created new opportunities for various applications. However, most tunable metasurface devices via different modulation techniques exhibit large fabrication difficulties or narrow bandwidths. Here, we use the all‐metallic split‐ring resonator to design a dynamically tunable metasurface that is highly sensitive to the ambient refractive index and capable of broadband beam switching. Different from the previous optical scatters, the split‐ring resonator is put on the metal substrate. Due to the existence of metallic substrate and large interaction of corner modes, the proposed resonator has small ohmic loss and high sensitivity to the ambient refractive index. By arraying the all‐metallic split‐ring resonators with different parameters, dynamic beam switching of anomalous reflection is demonstrated numerically. In particularly, the designed metasurface exhibits the dynamic beam switching in a broadband wavelength range of Δλ≈100 nm. Such an all‐metallic metasurface with high sensitivity can greatly reduce the designing difficulty of the tunable optical devices. The dynamic metadevices may find potential applications in stealth camouflage, information encryption, and data storage.
- Open Access
Numerical Study of Vibration Characteristics for Sensor Membrane in Transformer Oil
Membrane is the most important element of extrinsic Fabry-Perot interferometer sensors. Studying the relationship between working medium viscosity and membrane vibration characteristics are critical to the sensor design because the transformer oil viscosity will cause viscous loss during membrane vibration. The numerical investigation of membrane vibration characteristics in transformer oil is performed based on the finite element method. Besides, the effect of energy loss caused by viscosity is examined. It is firstly showed that the membrane has the highest sensitivity for the first-order vibration mode, and the transformer oil reduces the fundamental frequency by 60%. Subsequently, when viscosity and heat loss are considered, the amplitude is less than one-fifth of that without energy loss. The viscosity has a more significant effect on the velocity and temperature fields when the vibration frequency is close to the natural frequency. Finally, viscosity has a remarkable impact on the time domain response. Mechanical energy is converted into thermal energy during the vibration and the amplitude will gradually decrease with time. The effect of energy loss caused by viscosity on the membrane vibration characteristics is revealed, which would be important for an oil-immersed membrane design.
Open AccessNumerical Study of Vibration Characteristics for Sensor Membrane in Transformer Oil
Membrane is the most important element of extrinsic Fabry-Perot interferometer sensors. Studying the relationship between working medium viscosity and membrane vibration characteristics are critical to the sensor design because the transformer oil viscosity will cause viscous loss during membrane vibration. The numerical investigation of membrane vibration characteristics in transformer oil is performed based on the finite element method. Besides, the effect of energy loss caused by viscosity is examined. It is firstly showed that the membrane has the highest sensitivity for the first-order vibration mode, and the transformer oil reduces the fundamental frequency by 60%. Subsequently, when viscosity and heat loss are considered, the amplitude is less than one-fifth of that without energy loss. The viscosity has a more significant effect on the velocity and temperature fields when the vibration frequency is close to the natural frequency. Finally, viscosity has a remarkable impact on the time domain response. Mechanical energy is converted into thermal energy during the vibration and the amplitude will gradually decrease with time. The effect of energy loss caused by viscosity on the membrane vibration characteristics is revealed, which would be important for an oil-immersed membrane design.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 24, 84-89
Key Technologies For Ultra-Wideband Pds Detection In Transformer Under Ac/Dc Withstand Voltage Tests, Part 4: Feasibility Analysis Of Separation Or Grouping Technology Based On Pulse Current Sequence
Currently, the AC and DC withstand voltage PD test based on the traditional pulse current method with wideband or narrowband according the IEC 60270, the detection frequency band is only within 1 MHz, which greatly loses the information in time and frequency domain of the pulse current waveforms. So it is always difficult to eliminate the random interference pulse signals at the background of the substation, which seriously affects the test process. While the 4.6 “ultra-wideband instruments for PD detection” is defined based on PD pulse current waveform in the IEC 60270, but due to lack of the experimental research and engineering applications, no recommendations have been made for this type of method. In this paper, we summarized the characteristics of PD pulse current waveform in time and frequency domain, and intelligent analysis includes separation and clustering technologies, to make the feasibility analysis of anti-interference technology based on the PD pulse current sequence obtained using the ultra-wideband detection.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 24, 84-89
Key Technologies For Ultra-Wideband Pds Detection In Transformer Under Ac/Dc Withstand Voltage Tests, Part 4: Feasibility Analysis Of Separation Or Grouping Technology Based On Pulse Current Sequence
Currently, the AC and DC withstand voltage PD test based on the traditional pulse current method with wideband or narrowband according the IEC 60270, the detection frequency band is only within 1 MHz, which greatly loses the information in time and frequency domain of the pulse current waveforms. So it is always difficult to eliminate the random interference pulse signals at the background of the substation, which seriously affects the test process. While the 4.6 “ultra-wideband instruments for PD detection” is defined based on PD pulse current waveform in the IEC 60270, but due to lack of the experimental research and engineering applications, no recommendations have been made for this type of method. In this paper, we summarized the characteristics of PD pulse current waveform in time and frequency domain, and intelligent analysis includes separation and clustering technologies, to make the feasibility analysis of anti-interference technology based on the PD pulse current sequence obtained using the ultra-wideband detection.
- Open Access
Locating Ultrasonic Signals Employing MEMS-On-Fiber Sensors
Sound sensing finds wide applications in various fields, such as underwater detection, structural health monitoring, and medical diagnosis, to name just a few. Based on our previously developed MEMS-on-fiber sensors, showing the advantages of low cost, small volume, and high performance, a three-dimensional ultrasonic localization system employing four such sensors was established in this work. A time difference of arrival (TDOA) algorithm was utilized to analyze the acquired data and then calculate the accurate position of the ultrasonic signal source. Plenty of practical measurements were performed, and the derived localization deviation in the region of 2 m × 2 m × 1 m was about 2–5 mm. Outside this region, the deviation tended to increase due to the directional sensitivity existing in these sensors. As a result, for a more accurate localization requirement, more sensing probes are needed in order to depict a completely suitable application situation for MEMS technology.
Open AccessLocating Ultrasonic Signals Employing MEMS-On-Fiber Sensors
Sound sensing finds wide applications in various fields, such as underwater detection, structural health monitoring, and medical diagnosis, to name just a few. Based on our previously developed MEMS-on-fiber sensors, showing the advantages of low cost, small volume, and high performance, a three-dimensional ultrasonic localization system employing four such sensors was established in this work. A time difference of arrival (TDOA) algorithm was utilized to analyze the acquired data and then calculate the accurate position of the ultrasonic signal source. Plenty of practical measurements were performed, and the derived localization deviation in the region of 2 m × 2 m × 1 m was about 2–5 mm. Outside this region, the deviation tended to increase due to the directional sensitivity existing in these sensors. As a result, for a more accurate localization requirement, more sensing probes are needed in order to depict a completely suitable application situation for MEMS technology.
- Open Access
Low-Cost, High-Performance Fiber Optic Fabry–Perot Sensor for Ultrasonic Wave Detection
This study describes a novel fiber optic extrinsic Fabry–Perot interferometric (EFPI) ultrasonic sensor comprising a low-cost and high-performance silicon diaphragm. A vibrating diaphragm, 5 μm thick, was fabricated by using the Microelectromechanical Systems (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. The Fabry–Perot (FP) cavity length was solely determined during the manufacturing process of the diaphragm by defining a specific stepped hole on the handling layer of the SOI wafer, which made the assembly of the sensor easier. In addition, the use of cheap and commercially available components and MEMS processing technology in the development of the sensing system, limited the cost of the sensor. The experimental tests showed that the minimum detectable ultrasonic pressure was 1.5 mPa/sqrt(Hz) −0.625 mPa/sqrt(Hz) between 20 kHz and 40 kHz. As a result, this sensor has the potential to successfully detect weak ultrasonic signals.
Open AccessLow-Cost, High-Performance Fiber Optic Fabry–Perot Sensor for Ultrasonic Wave Detection
This study describes a novel fiber optic extrinsic Fabry–Perot interferometric (EFPI) ultrasonic sensor comprising a low-cost and high-performance silicon diaphragm. A vibrating diaphragm, 5 μm thick, was fabricated by using the Microelectromechanical Systems (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. The Fabry–Perot (FP) cavity length was solely determined during the manufacturing process of the diaphragm by defining a specific stepped hole on the handling layer of the SOI wafer, which made the assembly of the sensor easier. In addition, the use of cheap and commercially available components and MEMS processing technology in the development of the sensing system, limited the cost of the sensor. The experimental tests showed that the minimum detectable ultrasonic pressure was 1.5 mPa/sqrt(Hz) −0.625 mPa/sqrt(Hz) between 20 kHz and 40 kHz. As a result, this sensor has the potential to successfully detect weak ultrasonic signals.
- Open Access
Directional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source.
Open AccessDirectional Sensitivity of a MEMS-Based Fiber-Optic Extrinsic Fabry–Perot Ultrasonic Sensor for Partial Discharge Detection
Extrinsic Fabry–Perot (FP) interferometric sensors are being intensively applied for partial discharge (PD) detection and localization. Previous research work has mainly focused on novel structures and materials to improve the sensitivity and linear response of these sensors. However, the directional response behavior of an FP ultrasonic sensor is also of particular importance in localizing the PD source, which is rarely considered. Here, the directional sensitivity of a microelectromechanical system (MEMS)-based FP ultrasonic sensor with a 5-μm-thick micromechanical vibrating diaphragm is experimentally investigated. Ultrasonic signals from a discharge source with varying incident angles and linear distances are measured and analyzed. The results show that the sensor has a 5.90 dB amplitude fluctuation over a ±60° incident range and an exciting capability to detect weak PD signals from 3 m away due to its high signal–noise ratio. The findings are expected to optimize the configuration of a sensor array and accurately localize the PD source.
- Open Access
A Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection
A novel beam-supported membrane (BSM) structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI) sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs). The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM) structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases), and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR). A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.
Open AccessA Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection
A novel beam-supported membrane (BSM) structure for the fiber optic extrinsic Fabry-Perot interferometer (EFPI) sensors showing an enhanced performance and an improved resistance to the temperature change was proposed for detecting partial discharges (PDs). The fundamental frequency, sensitivity, linear range, and flatness of the BSM structure were investigated by employing the finite element simulations. Compared with the intact membrane (IM) structure commonly used by EFPI sensors, BSM structure provides extra geometrical parameters to define the fundamental frequency when the diameter of the whole membrane and its thickness is determined, resulting in an enhanced design flexibility of the sensor structure. According to the simulation results, it is noted that BSM structure not only shows a much higher sensitivity (increased by almost four times for some cases), and a wider working range of fundamental frequency to choose, but also an improved linear range, making the system development much easier. In addition, BSM structure presents a better flatness than its IM counterpart, providing an increased signal-to-noise ratio (SNR). A further improvement of performance is thought to be possible with a step-forward structural optimization. The BSM structure shows a great potential to design the EFPI sensors, as well as others for detecting the acoustic signals.