CSChangku Sun

Changku Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Changku Sun has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Peng Wang

    State Key Laboratory of Precision Measurement Technology and Instruments, School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China

    9 shared publications
  • Yixing Gou

    School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300401, China

    2 shared publications
  • Zean Bu

    State Key Lab of Precision Measuring Technology and Instruments, Tianjin University, Weijin Road, Tianjin 300072, China

    2 shared publications
  • Caizhi Yu

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

    1 shared publication
  • Changjie Liu

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China

    1 shared publication
  • Dahai Ren

    State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China

    1 shared publication

Latest Publications

  • DDSPNet: A Two-stage defect detection and severity prediction model for industrial products

    by Kai Tian, Shuai Yang, Liming Chen, Kai Wang, Yongzhen Ke, Zhengyu Miao, Jianghong Hu, Changku Sun, Xiaodong Zhang


  • Open Access

    Micro-Vibration Signal Denoising Algorithm of Spectral Morphology Fitting Based on Variational Mode Decomposition

    by Caizhi Yu, Yutai Lu, Yue Li, Peng Wang, Changku Sun

    Environmental micro-vibration has a significant impact on the proper functioning of semiconductor production and testing equipment such as the Czochralski growth furnace, polishing machine, photoetching machine, scanning electron microscope, etc. Low-frequency micro vibration has a significant influence on the normal operation of high-precision machining and testing equipment, and even causes irreversible damage to the equipment. Therefore, the micro-vibration test has important theoretical significance and engineering value for guiding the vibration isolation design of an electronic industrial workshop and ensuring the stable operation of various precision equipment in the workshop. As the observed acceleration signal is affected by noise introduced by the acceleration sensor itself, the signal processing circuit, the external power supply and interference from environmental factors, direct integration operations can lead to problems such as baseline drift and signal distortion in the calculation results. Aiming at the problem of noise interference in the micro-vibration measurement process, this paper proposed a micro-vibration signal denoising algorithm of spectral morphology fitting based on variational mode decomposition. The observed acceleration signal is decomposed into several orders of finite bandwidth intrinsic mode function components. The asymmetric Gaussian mixture model is used to complete the fitting of the spectral curves of each order of intrinsic mode function components. We can obtain the relevant parameters of the asymmetric Gaussian mixture model curves to complete the division of the effective information frequency band and finally achieve the denoising of the observed acceleration signal. Finally, the algorithm of this paper is compared with traditional denoising algorithms through numerical simulation examples and comparative experiments on denoising effects. The results show that the proposed algorithm has higher accuracy and anti-noise ability.


  • Open Access

    Semantic Lidar-Inertial SLAM for Dynamic Scenes

    by Zean Bu, Changku Sun, Peng Wang

    Over the past few years, many impressive lidar-inertial SLAM systems have been developed and perform well under static scenes. However, most tasks are under dynamic environments in real life, and the determination of a method to improve accuracy and robustness poses a challenge. In this paper, we propose a semantic lidar-inertial SLAM approach with the combination of a point cloud semantic segmentation network and lidar-inertial SLAM LIO mapping for dynamic scenes. We import an attention mechanism to the PointConv network to build an attention weight function to improve the capacity to predict details. The semantic segmentation results of the point clouds from lidar enable us to obtain point-wise labels for each lidar frame. After filtering the dynamic objects, the refined global map of the lidar-inertial SLAM sytem is clearer, and the estimated trajectory can achieve a higher precision. We conduct experiments on an UrbanNav dataset, whose challenging highway sequences have a large number of moving cars and pedestrians. The results demonstrate that, compared with other SLAM systems, the accuracy of trajectory can be improved to different degrees.


  • Open Access

    Inertial-Assisted Immunomagnetic Bioplatform towards Efficient Enrichment of Circulating Tumor Cells

    by Yixing Gou, Jiawen Liu, Changku Sun, Peng Wang, Zheng You, Dahai Ren

    Serving as an effective biomarker in liquid biopsy, circulating tumor cells (CTCs) can provide an accessible source for cancer biology study. For the in-depth evaluation of CTCs in cancer analysis, their efficient enrichment is essential, owing to their low abundance in peripheral blood. In this paper, self-assembled immunomagnetic beads were developed to isolate CTCs from the ordered bundles of cells under the assistance of the spiral inertial effect. Parametric numerical simulations were performed to explore the velocity distribution in the cross section. Based on this chip, rare CTCs could be recovered under the throughput of 500 μL/min, making this device a valuable supplement in cancer analysis, diagnostics, and therapeutics.


  • Open Access

    Calibration of Camera and Flash LiDAR System with a Triangular Pyramid Target

    by Zean Bu, Changku Sun, Peng Wang, Hang Dong

    Calibration between multiple sensors is a fundamental procedure for data fusion. To address the problems of large errors and tedious operation, we present a novel method to conduct the calibration between light detection and ranging (LiDAR) and camera. We invent a calibration target, which is an arbitrary triangular pyramid with three chessboard patterns on its three planes. The target contains both 3D information and 2D information, which can be utilized to obtain intrinsic parameters of the camera and extrinsic parameters of the system. In the proposed method, the world coordinate system is established through the triangular pyramid. We extract the equations of triangular pyramid planes to find the relative transformation between two sensors. One capture of camera and LiDAR is sufficient for calibration, and errors are reduced by minimizing the distance between points and planes. Furthermore, the accuracy can be increased by more captures. We carried out experiments on simulated data with varying degrees of noise and numbers of frames. Finally, the calibration results were verified by real data through incremental validation and analyzing the root mean square error (RMSE), demonstrating that our calibration method is robust and provides state-of-the-art performance.


  • Open Access

    A Four-Probe Method Using Different Probe Spacings for Measurement and Exact Reconstruction of Parallel Profiles

    by Xi Chen, Changku Sun, Changjie Liu, Luhua Fu

    To realize the measurement and exact reconstruction of a pair of parallel profiles, a new scanning method using four displacement sensors as probes and different probe spacings has been invented with the advantage of preventing data processing error. The measuring device is placed between the measured objects and moved by a scanning stage to collect measurement data of both measured profiles. Considering many existing methods, the high lateral resolution of the reconstruction result and the rejection of the data processing error cannot always be achieved at the same time. When the measured profiles are in the short wavelength range, data processing errors are often on the same order of magnitude as the height difference of the measured profiles. The new method can eliminate both the straightness error of the measurement reference and the data processing error. The exact reconstruction retaining the high lateral resolution and without data processing error can be realized by rational position arrangement of sensors and corresponding processing method of the measurement data. The new method possesses the following advantages: (i) achievement of the exact reconstruction without data processing error; (ii) high lateral resolution not limited by probe spacing; (iii) concise operation without zero calibration of probes; and (iv) suitability for on-machine measurement. The feasibility and advantages of the new method were demonstrated by theoretical analyses, simulations, and experimental results.


  • Open Access

    Calibration Method of Orthogonally Splitting Imaging Pose Sensor Based on KDFcmPUM

    by Na Zhao, Changku Sun, Peng Wang

    This paper proposes a partition of unity method (PUM) based on KDFCM (KDFcmPUM) that can be implemented to solve the dense matrix problem that occurs when the radial basis function (RBF) interpolation method deals with a large amount of scattered data. This method introduces a kernel fuzzy clustering algorithm to improve clustering accuracy and achieve the partition of unity. The local compact support RBF is used to construct the weight function, and local expression is obtained from the interpolation of the global RBF. Finally, the global expression is constructed by the weight function and local expression. In this paper, the method is applied to the orthogonally splitting imaging pose sensor to establish the mathematical model and the calibration and test experiments are carried out. The calibration and test accuracy both reached ±0.1 mm, and the number of operations was reduced by 4% at least. The experimental results show that KDFcmPUM is effective.

  • Open Access

    Noise Reduction for MEMS Gyroscope Signal: A Novel Method Combining ACMP with Adaptive Multiscale SG Filter Based on AMA

    by Jingjing He, Changku Sun, Peng Wang

    In this paper, a novel hybrid method combining adaptive chirp mode pursuit (ACMP) with an adaptive multiscale Savitzky–Golay filter (AMSGF) based on adaptive moving average (AMA) is proposed for offline denoising micro-electromechanical system (MEMS) gyroscope signal. The denoising scheme includes preliminary denoising and further denoising. At the preliminary denoising stage, the original gyroscope signal is decomposed into signal modes one by one using ACMP with modified stopping criterion based on mutual information. Useful information is extracted while most noise is discarded in the residue at this stage. Then, AMSGF is proposed to further denoise the signal modes. Sample variance based on AMA is used to adjust the window size of AMSGF adaptively. Practical MEMS gyroscope signal denoising results under different motion conditions show the superior performance of the proposed method over empirical mode decomposition (EMD)-based denoising, discrete wavelet threshold denoising, and variational mode decomposition (VMD)-based denoising. Moreover, AMSGF is proven to gain a better denoising effect than some other common smoothing methods.


  • A hybrid method for MEMS gyroscope signal error compensation

    by Xiaoting Guo, Changku Sun, Peng Wang, Lu Huang

    Purpose: This paper aims to propose a hybrid method based on polynomial fitting bias self-compensation, grey forward-backward linear prediction (GFBLP) and moving average filter (MAF) for error compensation in micro-electromechanical system gyroscope signal especially under motion state. Design/methodology/approach: The error compensation can be divided into two processes: bias correction and noise reduction. A polynomial drift angle fitting algorithm is used to correct bias before denoising processing. For noise reduction, operation can be taken in two stages: detection and processing. First, sample variances are used to judge motion state. According to the detection results, algorithmic system switches between grey GFBLP and MAF to ensure fast convergence rate and small steady-state error. Findings: Experimental results show that the proposed method can correct bias effectively for practical gyroscope signal, and can eliminate noise effectively for both practical gyroscope signal and synthetic signal, which indicates the effectiveness of the proposed method. Originality/value: Bias correction and noise reduction are considerations. Noise contained in practical or synthetic signal can be reduced rapidly and effectively, which benefits from the new idea of combination grey GFBLP, MAF and sample variances. And most importantly, it is applicable for signal denoising under arbitrary motion state condition, which is different from other methods where the convergence performance is seldom analyzed.


  • Open Access

    Calibration Method of Orthogonally Splitting Imaging Pose Sensor Based on General Imaging Model

    by Na Zhao, Changku Sun, Peng Wang

    Orthogonally splitting imaging pose sensor is a new sensor with two orthogonal line array charge coupled devices (CCDs). Owing to its special structure, there are distortion correction and imaging model problems during the calibration procedure. This paper proposes a calibration method based on the general imaging model to solve these problems. The method introduces Plücker Coordinate to describe the mapping relation between the image coordinate system and the world coordinate system. This paper solves the mapping relation with radial basis function interpolation and adaptively selecting control points with Kmeans clustering method to improve the fitting accuracy. This paper determines the appropriate radial basis function and its shape parameter by experiments. And these parameters are used to calibrate the orthogonally splitting imaging pose sensor. According to the calibration result, the root mean square (RMS)of calibration dataset and the RMS of test dataset are 0.048 mm and 0.049 mm. A comparative experiment is conducted between the pinhole imaging model and the general imaging model. Experimental results show that the calibration method based on general imaging model applies to the orthogonally splitting imaging pose sensor. The calibration method requires only one image corresponding to the target in the world coordinates and distortion correction is not required to be taken into account. Compared with the calibration method based on the pinhole imaging model, the calibration procedure based on the general imaging model is easier and accuracy is greater.