Shijun You
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shijun You has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Huan Zhang
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
6 shared publications - Wandong Zheng
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
4 shared publications - Yaran Wang
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
4 shared publications - Tianzhen Ye
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
3 shared publications - Yanzhe Yu
School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
3 shared publications - Shen Wei
The Bartlett School of Sustainable Construction, University College London (UCL), 1–19 Torrington Place, London WC1E 7HB, UK
2 shared publications
Latest Publications
- Open Access
- 30 May 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 8843
Research on Optimization Method of Integrated Energy System Network Planning
The development of an integrated energy system (IES) is conducive to promoting the transformation of the energy system and helping to achieve the ‘double carbon’ goal in China. The IES integrates cooling, heating, electricity, gas, and other energy resources, which is significantly more difficult than single energy network planning. This paper systematically sorts out the process of IES network planning and proposes an improved methodology. Firstly, the bottom-up dynamic multiple-load forecasting method of 8760 h a year is proposed as the basis of system configuration and capacity selection. Subsequently, a planning method for energy station location and route optimization using the Dijkstra algorithm is constructed by applying the P-median optimization model. Finally, when optimizing the capacity allocation of the IES, the complementary characteristics of natural gas, electricity and heat, as well as the corresponding energy demand characteristic, have been fully considered, so that the optimization objectives can be reasonably determined. Through the actual calculation, it is found that the optimization method proposed in this paper can reduce the construction cost of the network by 41%. The work combines the process of energy network planning and capacity configuration of IES, which provides a simple, easy and economical solution for IES planning in new areas.
- 30 May 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 8843
Open AccessResearch on Optimization Method of Integrated Energy System Network Planning
The development of an integrated energy system (IES) is conducive to promoting the transformation of the energy system and helping to achieve the ‘double carbon’ goal in China. The IES integrates cooling, heating, electricity, gas, and other energy resources, which is significantly more difficult than single energy network planning. This paper systematically sorts out the process of IES network planning and proposes an improved methodology. Firstly, the bottom-up dynamic multiple-load forecasting method of 8760 h a year is proposed as the basis of system configuration and capacity selection. Subsequently, a planning method for energy station location and route optimization using the Dijkstra algorithm is constructed by applying the P-median optimization model. Finally, when optimizing the capacity allocation of the IES, the complementary characteristics of natural gas, electricity and heat, as well as the corresponding energy demand characteristic, have been fully considered, so that the optimization objectives can be reasonably determined. Through the actual calculation, it is found that the optimization method proposed in this paper can reduce the construction cost of the network by 41%. The work combines the process of energy network planning and capacity configuration of IES, which provides a simple, easy and economical solution for IES planning in new areas.
- Open Access
- 18 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3612
Exploring the Applicability of Building Energy Performance Certification Systems in Underground Stations in China
To improve the energy efficiency of underground metro stations, and in view of the absence of a comprehensive energy performance evaluation system for underground stations, this study introduced building Energy Performance Certification (EPC) tools into underground stations and conducted a comparative analysis of their applicability. The findings indicated that due to the unique characteristics of underground stations, China’s current EPC system was inapplicable to them. Specifically, (1) for basic items, although evaluation methods were available, due to the limited energy use data for the statistical method, the self-reference method was preferred, but its calculation encountered issues with missing reference values; (2) for prescribed items, the emphasis should be placed on the energy efficiency requirements of energy use systems rather than those of the thermal performance of envelopes; (3) for alternative items, the energy recovery measures related to the heat dissipation of trains and the piston wind should be addressed. Furthermore, a case study was conducted for verification of the proposed energy evaluation method, and the EPC system was updated based on the results of the comparison. The authors hope that this study will help improve China’s energy evaluation methods for underground stations and serve as a reference for expanding the EPC system to include public transportation buildings.
- 18 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3612
Open AccessExploring the Applicability of Building Energy Performance Certification Systems in Underground Stations in China
To improve the energy efficiency of underground metro stations, and in view of the absence of a comprehensive energy performance evaluation system for underground stations, this study introduced building Energy Performance Certification (EPC) tools into underground stations and conducted a comparative analysis of their applicability. The findings indicated that due to the unique characteristics of underground stations, China’s current EPC system was inapplicable to them. Specifically, (1) for basic items, although evaluation methods were available, due to the limited energy use data for the statistical method, the self-reference method was preferred, but its calculation encountered issues with missing reference values; (2) for prescribed items, the emphasis should be placed on the energy efficiency requirements of energy use systems rather than those of the thermal performance of envelopes; (3) for alternative items, the energy recovery measures related to the heat dissipation of trains and the piston wind should be addressed. Furthermore, a case study was conducted for verification of the proposed energy evaluation method, and the EPC system was updated based on the results of the comparison. The authors hope that this study will help improve China’s energy evaluation methods for underground stations and serve as a reference for expanding the EPC system to include public transportation buildings.
- 1 September 2021
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 15 (1) , 1-13
The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study
- 1 September 2021
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 15 (1) , 1-13
The effects of manual airing strategies and architectural factors on the indoor air quality in college classrooms: a case study
- Open Access
Research on the Optimization Design of Solar Energy-Gas-Fired Boiler Systems for Decentralized Heating
Solar energy-gas-fired boiler heating systems attract widespread attention due to their eco-friendly technologies and reasonable prices. In order to promote the application of a solar energy-gas-fired boiler system for decentralized heating, this study proposed a holistic method to optimize the combination of equipment specifications and control strategies of the system. A detailed mathematical model of the hybrid energy system was developed and validated by experiments to simulate various operating conditions and evaluate the optimal design results. A case study was conducted in Tianjin, China, and optimal schemes were obtained. The influence of different factors on the system’s annual comprehensive energy efficiency ratio (AEER) and annual cost (AC) were studied by sensitivity analysis; the results showed that the solar collector area was extremely valuable for the optimization of AEER and AC. The results of this study provide a reference for the optimization design of the solar energy-gas-fired boiler system, which is beneficial to the promotion of the utilization of solar energy.
Open AccessResearch on the Optimization Design of Solar Energy-Gas-Fired Boiler Systems for Decentralized Heating
Solar energy-gas-fired boiler heating systems attract widespread attention due to their eco-friendly technologies and reasonable prices. In order to promote the application of a solar energy-gas-fired boiler system for decentralized heating, this study proposed a holistic method to optimize the combination of equipment specifications and control strategies of the system. A detailed mathematical model of the hybrid energy system was developed and validated by experiments to simulate various operating conditions and evaluate the optimal design results. A case study was conducted in Tianjin, China, and optimal schemes were obtained. The influence of different factors on the system’s annual comprehensive energy efficiency ratio (AEER) and annual cost (AC) were studied by sensitivity analysis; the results showed that the solar collector area was extremely valuable for the optimization of AEER and AC. The results of this study provide a reference for the optimization design of the solar energy-gas-fired boiler system, which is beneficial to the promotion of the utilization of solar energy.
- Open Access
Defrosting Performance Improvement of Air-Source Heat Pump Combined Refrigerant Direct-Condensation Radiant Floor Heating System with Phase Change Material
Traditional defrosting methods applied to solve frosting problems of air-source heat pumps operating in cold periods may reduce heat capacity of the system and decrease indoor thermal comfort. In order to improve the performance of air-source heat pump (ASHP) and maintain indoor temperature in defrosting conditions, an air-source heat pump combined with a refrigerant direct-condensation radiant floor heating system with phase change material is proposed and evaluated in this study. Two radiant floor heating terminals with and without composite phase change material modules were compared through experiments. A composite phase change material based on dodecanoic acid-tetradecanol-hexadecanol mixture and expanded graphite was investigated for this application. Experimental results indicate that both heat fluxes of two comparing terminals are higher than 70 W/m2 in heating condition. At the same time, the floor surface temperature, indoor air temperature, and heating capacity of the terminal with composite phase change material modules are higher than those without composite phase change material modules in defrosting condition. This suggests that the proposed system with composite phase change material modules can improve indoor thermal comfort in defrosting condition as well as satisfy the heating requirement in heating condition.
Open AccessDefrosting Performance Improvement of Air-Source Heat Pump Combined Refrigerant Direct-Condensation Radiant Floor Heating System with Phase Change Material
Traditional defrosting methods applied to solve frosting problems of air-source heat pumps operating in cold periods may reduce heat capacity of the system and decrease indoor thermal comfort. In order to improve the performance of air-source heat pump (ASHP) and maintain indoor temperature in defrosting conditions, an air-source heat pump combined with a refrigerant direct-condensation radiant floor heating system with phase change material is proposed and evaluated in this study. Two radiant floor heating terminals with and without composite phase change material modules were compared through experiments. A composite phase change material based on dodecanoic acid-tetradecanol-hexadecanol mixture and expanded graphite was investigated for this application. Experimental results indicate that both heat fluxes of two comparing terminals are higher than 70 W/m2 in heating condition. At the same time, the floor surface temperature, indoor air temperature, and heating capacity of the terminal with composite phase change material modules are higher than those without composite phase change material modules in defrosting condition. This suggests that the proposed system with composite phase change material modules can improve indoor thermal comfort in defrosting condition as well as satisfy the heating requirement in heating condition.
- Open Access
Energy Consumption and CO2 Emissions of Coach Stations in China
As a critical transportation infrastructure, with a high flow of people and high-energy consumption in China, coach stations have great potential in energy saving and CO2 emission reduction. In this paper, the building information and energy consumption data of 29 coach stations in five climate regions of China were obtained by field investigations. The annual total comprehensive building energy consumption was 31.37–128.08 kWh/(m2·a). The annual total CO2 emissions from building operation in the coach stations was 17.01–134.77 kgCO2/(m2·a). The heating, ventilation and air conditioning (HVAC) system was the largest energy using and CO2 emissions sector: 30.42–72.47% of the energy consumption and 30.42–83.93% of the CO2 emissions were generated by HVAC system. The energy consumption and CO2 emission level of coach stations and that of other kinds of public buildings were compared. Results showed that the energy consumption and CO2 emission levels of coach stations investigated were relatively low, mainly because the passenger thermal comfort was scarified. Based on the investigation data, energy consumption analysis models of coach stations in five regions were established by simulation when the passenger thermal comfort was met. The potentials of energy saving and CO2 emission reduction were studied from forms of the HVAC system, heat recovery and natural illumination.
Open AccessEnergy Consumption and CO2 Emissions of Coach Stations in China
As a critical transportation infrastructure, with a high flow of people and high-energy consumption in China, coach stations have great potential in energy saving and CO2 emission reduction. In this paper, the building information and energy consumption data of 29 coach stations in five climate regions of China were obtained by field investigations. The annual total comprehensive building energy consumption was 31.37–128.08 kWh/(m2·a). The annual total CO2 emissions from building operation in the coach stations was 17.01–134.77 kgCO2/(m2·a). The heating, ventilation and air conditioning (HVAC) system was the largest energy using and CO2 emissions sector: 30.42–72.47% of the energy consumption and 30.42–83.93% of the CO2 emissions were generated by HVAC system. The energy consumption and CO2 emission level of coach stations and that of other kinds of public buildings were compared. Results showed that the energy consumption and CO2 emission levels of coach stations investigated were relatively low, mainly because the passenger thermal comfort was scarified. Based on the investigation data, energy consumption analysis models of coach stations in five regions were established by simulation when the passenger thermal comfort was met. The potentials of energy saving and CO2 emission reduction were studied from forms of the HVAC system, heat recovery and natural illumination.
- 23 June 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 13 (1) , 1-32
Experimental Investigation of Air-Source Heat Pump Heating System With a Novel Thermal Storage Refrigerant-Heated Panel
In response to the triple crisis of energy–environment–economy (3Es), the air-source heat pump (ASHP) system is considered to be one of the most feasible candidates to upgrade the traditional high emission heating solutions. In this paper, a novel thermal storage refrigerant-heated panel (RHP) is proposed for the ASHP heating system. Experiments were conducted in a climate chamber to test the heating and defrosting performance of the system, the thermal performance of the RHP, the system energy efficiency, and the system economic feasibility. The results show that the heat flux of the RHP is as high as 625.5 W/m2 at a condensation temperature of 40 °C and an outdoor air temperature of −7 °C. Meanwhile, the system is demonstrated to be reliable and competitive with efficient thermal stability in heating conditions and comfortable indoor thermal in defrosting conditions. The coefficient of performance (COP) ranges from 2.2 to 4.0 when the outdoor air temperature changes from −12 °C to 7 °C in the tests. Meanwhile, the initial capital cost and the total annual cost of the proposed system are 430 USD and 203.1 USD, respectively, which is competitive in the distracted heating systems.
- 23 June 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 13 (1) , 1-32
Experimental Investigation of Air-Source Heat Pump Heating System With a Novel Thermal Storage Refrigerant-Heated Panel
In response to the triple crisis of energy–environment–economy (3Es), the air-source heat pump (ASHP) system is considered to be one of the most feasible candidates to upgrade the traditional high emission heating solutions. In this paper, a novel thermal storage refrigerant-heated panel (RHP) is proposed for the ASHP heating system. Experiments were conducted in a climate chamber to test the heating and defrosting performance of the system, the thermal performance of the RHP, the system energy efficiency, and the system economic feasibility. The results show that the heat flux of the RHP is as high as 625.5 W/m2 at a condensation temperature of 40 °C and an outdoor air temperature of −7 °C. Meanwhile, the system is demonstrated to be reliable and competitive with efficient thermal stability in heating conditions and comfortable indoor thermal in defrosting conditions. The coefficient of performance (COP) ranges from 2.2 to 4.0 when the outdoor air temperature changes from −12 °C to 7 °C in the tests. Meanwhile, the initial capital cost and the total annual cost of the proposed system are 430 USD and 203.1 USD, respectively, which is competitive in the distracted heating systems.
- Open Access
A Grey-Box Dynamic Model of Plate Heat Exchangers Used in an Urban Heating System
This paper deals with the establishment of a grey-box model of plate heat exchangers. First, a second-order state space model of plate heat exchangers is developed. Then, the model is solved by the white-box method and grey-box method, respectively. In the white-box method, the linearization of the state space model is carried out by implicit difference scheme and the overall heat transfer coefficient was calculated with empirical correlation of the Nusselt number. In the grey-box method, a newly developed parameter identification method was established. The simulation results of two outlet temperatures by the grey-box and white-box method, respectively, are compared with the test data. It is shown that the grey-box method is more suitable and accurate for the simulations of outlet temperatures than the white-box method. Thus, it can provide practitioners and heating engineers with tools to design controllers for district heating systems.
Open AccessA Grey-Box Dynamic Model of Plate Heat Exchangers Used in an Urban Heating System
This paper deals with the establishment of a grey-box model of plate heat exchangers. First, a second-order state space model of plate heat exchangers is developed. Then, the model is solved by the white-box method and grey-box method, respectively. In the white-box method, the linearization of the state space model is carried out by implicit difference scheme and the overall heat transfer coefficient was calculated with empirical correlation of the Nusselt number. In the grey-box method, a newly developed parameter identification method was established. The simulation results of two outlet temperatures by the grey-box and white-box method, respectively, are compared with the test data. It is shown that the grey-box method is more suitable and accurate for the simulations of outlet temperatures than the white-box method. Thus, it can provide practitioners and heating engineers with tools to design controllers for district heating systems.
- Open Access
Experimental Investigation of the Transpired Solar Air Collectors and Metal Corrugated Packing Solar Air Collectors
The thermal performance of three novel solar air collectors with perforating corrugated plate, slit-perforated plate, and corrugated packing were experimentally studied in this paper. Experiments were conducted in Tianjin to study the thermal and dynamic performance of the collectors in cold and severe cold regions. A chamber with a PID (Proportion Integration Differentiation) temperature controller was designed to control the inlet air temperature of the three collectors. Effects of radiation intensity, inlet air temperature, and flow rate on the thermal efficiency and outlet air temperature were experimentally studied. The results indicated that the thermal efficiency of the three collectors in severe cold regions could be much higher than 50% and the collector with perforating corrugated plate had the highest thermal efficiency. The inlet air flow rate had significant effects on the thermal comfort of buildings in cold and severe cold regions and it should be lower than 45 m3/h. The results indicated that the pressure drops of collectors with perforating corrugated plate were a little larger than the collectors with slit-perforated plate, but the thermal efficiency and outlet air temperature was higher. Therefore, the collector with perforating corrugated plate was more suitable to use in cold and severe cold regions.
Open AccessExperimental Investigation of the Transpired Solar Air Collectors and Metal Corrugated Packing Solar Air Collectors
The thermal performance of three novel solar air collectors with perforating corrugated plate, slit-perforated plate, and corrugated packing were experimentally studied in this paper. Experiments were conducted in Tianjin to study the thermal and dynamic performance of the collectors in cold and severe cold regions. A chamber with a PID (Proportion Integration Differentiation) temperature controller was designed to control the inlet air temperature of the three collectors. Effects of radiation intensity, inlet air temperature, and flow rate on the thermal efficiency and outlet air temperature were experimentally studied. The results indicated that the thermal efficiency of the three collectors in severe cold regions could be much higher than 50% and the collector with perforating corrugated plate had the highest thermal efficiency. The inlet air flow rate had significant effects on the thermal comfort of buildings in cold and severe cold regions and it should be lower than 45 m3/h. The results indicated that the pressure drops of collectors with perforating corrugated plate were a little larger than the collectors with slit-perforated plate, but the thermal efficiency and outlet air temperature was higher. Therefore, the collector with perforating corrugated plate was more suitable to use in cold and severe cold regions.
- 17 December 2009
- Published by Springer Nature in Transactions of Tianjin University
- Vol. 15 (6) , 446-451
Coupled seepage and heat transfer intake model
- 17 December 2009
- Published by Springer Nature in Transactions of Tianjin University
- Vol. 15 (6) , 446-451
Coupled seepage and heat transfer intake model