CCCarlos Castán-Fernández

Carlos Castán-Fernández

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carlos Castán-Fernández has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study of the Thermal Conductivity of Different Geothermal Grouting Materials with a Homemade Apparatus

    by Carlos Castán-Fernández, Germán Marcos-Robredo, Miguel Ángel Rey-Ronco, Teresa Alonso-Sánchez

    Thermal conductivity is an essential property of the geothermal grout, which in turn is considered the most important element in a vertical closed-loop ground heat exchanger. The main aim of this work is to determine the thermal conductivity of four of the most commonly used geothermal grouting materials using a homemade apparatus, developed by the research team. The tests were also performed with a commercial thermal conductivity meter, the Shotherm QTM-F1. Both the homemade apparatus, called MCT, and the commercial thermal conductivity meter are based on the transient hot wire method. The components used to make the specimens are cement, silica sand, bentonite, water and superplasticizer. A laboratory mortar mixer was used to prepare all mixtures. Later, the samples were cured in a water bath for 7 days and finally the samples were dried at 60 °C for 24 h before testing. Each of the samples tested is formed of two solid rectangular prisms of the same material and of the same dimensions (180 mm × 70 mm × 50 mm). The obtained results with the MCT apparatus are similar to the data reported in the literature and to those obtained using the Shotherm QTM-F1thermal conductivity meter. The deviations of the values measured with the MCT apparatus are, in all cases, less than 10%.


  • Open Access

    Design, Construction and Commissioning of an Apparatus for Measuring the Thermal Conductivity of Geothermal Grouting Materials Based on the Transient Hot Wire Method

    by Carlos Castán-Fernández, Germán Marcos-Robredo, Miguel Ángel Rey-Ronco, Teresa Alonso-Sánchez

    The aim of the present study is to develop an apparatus for the measurement of the thermal conductivity of geothermal grouting materials. The apparatus, named MCT, is designed and constructed as a direct application of a mathematical model of heat transference for conduction in an infinite homogeneous isotropic medium using a linear heat source of infinite length, infinitesimal radius and radial heat flow. This application is known as the transient hot wire method. The apparatus mainly consists of a hot wire, a power supply, a temperature sensor and a datalogger. The commissioning of the developed apparatus is carried out by means of the calibration of the temperature sensor, as well as measurements of thermal conductivity using four reference samples whose thermal conductivity is known. Each of the reference samples is formed of two solid rectangular prisms of the same material and of the same dimensions. MCT is precise and accurate. In good experimental conditions the uncertainty of the measurements is within 10%. In addition, the MCT apparatus is light and with reduced dimensions.