Teresa Alonso-Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Teresa Alonso-Sánchez has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Ángel Rey Ronco
Department of Energy, University of Oviedo, 33004 Oviedo, Spain
15 shared publications - María Pilar Castro-García
Department of Energy University of Oviedo Oviedo Asturias Spain
12 shared publications - Germán Marcos-Robredo
Department of Energy, University of Oviedo, 33004 Oviedo, Spain
8 shared publications - Carlos Castán-Fernández
Department of Business Administration, University of Oviedo, 33004 Oviedo, Spain
2 shared publications Adela Ramos-Escudero
1 shared publication- Alejandro García-Gil
Geological Survey of Spain (IGME-CSIC), Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in Renewable Energy
- Vol. 277
Shallow geothermal energy in the Canary Islands: Resource and technical potential for energy planning
- 17 September 2026
- Published by Elsevier in Renewable Energy
- Vol. 277
Open AccessShallow geothermal energy in the Canary Islands: Resource and technical potential for energy planning
- Open Access
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5591
Modeling Thermal Interference Between Shallow Geothermal Boreholes Using TRNSYS: Application to the Q-Thermie-Uniovi Boreholes (Asturias, Spain)
This study presents the implementation of a new Type for TRNSYS based on the integral exponential function, which is fundamental in subsurface heat transfer modeling. This function can be expressed as a series expansion, and the developed Type enables the representation of multiple terms in this expansion. To validate its accuracy, the model’s results are compared with experimental data from two geothermal boreholes located in Asturias, Spain: Q-Thermie-Uniovi 1 and Q-Thermie-Uniovi 2. These boreholes, spaced 7.3 m apart and each 48 m deep, were used in a thermal response test, where Q-Thermie-Uniovi 1 underwent thermal injection while temperature measurements were recorded in Q-Thermie-Uniovi 2 over a period of three months. This study evaluates how the number of terms in the series expansion influences the model’s accuracy and demonstrates that the newly developed Type effectively replicates experimental data. This work provides a robust tool for optimizing the design of geothermal systems and enhancing the understanding of subsurface heat transfer dynamics.
- 16 May 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (10) , 5591
Open AccessModeling Thermal Interference Between Shallow Geothermal Boreholes Using TRNSYS: Application to the Q-Thermie-Uniovi Boreholes (Asturias, Spain)
This study presents the implementation of a new Type for TRNSYS based on the integral exponential function, which is fundamental in subsurface heat transfer modeling. This function can be expressed as a series expansion, and the developed Type enables the representation of multiple terms in this expansion. To validate its accuracy, the model’s results are compared with experimental data from two geothermal boreholes located in Asturias, Spain: Q-Thermie-Uniovi 1 and Q-Thermie-Uniovi 2. These boreholes, spaced 7.3 m apart and each 48 m deep, were used in a thermal response test, where Q-Thermie-Uniovi 1 underwent thermal injection while temperature measurements were recorded in Q-Thermie-Uniovi 2 over a period of three months. This study evaluates how the number of terms in the series expansion influences the model’s accuracy and demonstrates that the newly developed Type effectively replicates experimental data. This work provides a robust tool for optimizing the design of geothermal systems and enhancing the understanding of subsurface heat transfer dynamics.
- Open Access
Thermal Diffusivity in the Subsoil: A Case Study in the Asturias (Northern Spain)
This study presents a novel methodology for determining the apparent thermal diffusivity of subsoil in situ, employing two heat transfer models within the subsurface: one method is based on heat conduction caused by air temperature oscillations, while the other considers heat transmission via both conduction and convection due to groundwater flow. Differential equations were solved, and non-linear regression analysis was employed. This method has direct applications in various engineering and environmental domains, such as underground transmission lines, oil and gas pipelines, radioactive waste management, and geothermal systems, especially in the context of implementing horizontal geothermal collectors (HGC). The apparent thermal diffusivity value of 1.514 × 10−6 m2 s−1, within a 95% confidence interval spanning 1.512 × 10−6 m2 s−1 and 1.516 × 10−6 m2 s−1, was obtained from the section between 1.67 and 3.86 m depth in a research borehole located in Asturias, Northern Spain, using twenty-one temperature sensors. The method allowed for the calculation of the subsoil’s apparent thermal diffusivity up to a depth of 14.55 m.
Open AccessThermal Diffusivity in the Subsoil: A Case Study in the Asturias (Northern Spain)
This study presents a novel methodology for determining the apparent thermal diffusivity of subsoil in situ, employing two heat transfer models within the subsurface: one method is based on heat conduction caused by air temperature oscillations, while the other considers heat transmission via both conduction and convection due to groundwater flow. Differential equations were solved, and non-linear regression analysis was employed. This method has direct applications in various engineering and environmental domains, such as underground transmission lines, oil and gas pipelines, radioactive waste management, and geothermal systems, especially in the context of implementing horizontal geothermal collectors (HGC). The apparent thermal diffusivity value of 1.514 × 10−6 m2 s−1, within a 95% confidence interval spanning 1.512 × 10−6 m2 s−1 and 1.516 × 10−6 m2 s−1, was obtained from the section between 1.67 and 3.86 m depth in a research borehole located in Asturias, Northern Spain, using twenty-one temperature sensors. The method allowed for the calculation of the subsoil’s apparent thermal diffusivity up to a depth of 14.55 m.
- Open Access
- 28 January 2023
- Published by MDPI AG in Inventions
- Vol. 8 (1) , 30
Apparatus Development for the Measurement of the Thermal Conductivity of Geothermal Backfill Materials
This paper describes the design, construction, validation, and calibration of a thermal conductivity measuring apparatus for geothermal backfill materials in the range from 0.13–2.80 W/m·K. The developed apparatus is based on the Transient Hot Wire (THW) method whose mathematical basis is the Infinite Linear Source (ILS) model. The apparatus consists of a nichrome hot wire, an adjustable direct current power supply, a temperature sensor (K-type thermocouple), and a datalogger. For the validation and calibration of the developed apparatus, four standard samples have been used with a known thermal conductivity, to 3.0 W/m·K. Furthermore, the thermal conductivity of four geothermal backfill materials of common use (bentonite, neat cement, cement–sand mortar, and cement–bentonite mortar) has been measured using both the developed apparatus and a commercial meter.
- 28 January 2023
- Published by MDPI AG in Inventions
- Vol. 8 (1) , 30
Open AccessApparatus Development for the Measurement of the Thermal Conductivity of Geothermal Backfill Materials
This paper describes the design, construction, validation, and calibration of a thermal conductivity measuring apparatus for geothermal backfill materials in the range from 0.13–2.80 W/m·K. The developed apparatus is based on the Transient Hot Wire (THW) method whose mathematical basis is the Infinite Linear Source (ILS) model. The apparatus consists of a nichrome hot wire, an adjustable direct current power supply, a temperature sensor (K-type thermocouple), and a datalogger. For the validation and calibration of the developed apparatus, four standard samples have been used with a known thermal conductivity, to 3.0 W/m·K. Furthermore, the thermal conductivity of four geothermal backfill materials of common use (bentonite, neat cement, cement–sand mortar, and cement–bentonite mortar) has been measured using both the developed apparatus and a commercial meter.
- Open Access
A Device to Register Temperature in Boreholes in Northwest Spain for Geothermal Research
This paper presents a device used to measure and register temperature for long-term subsoil measurements in boreholes. The borehole of this study is located in Gijón (Asturias, Spain). The measurements were made through two fixed sets of sensors coupled to the geothermal pipe, constituting two independent installations: (a) a commercial device called “Hobo”, which uses TMCx-HD-specific sensors based on resistors with variable resistance; and (b) a device built by this research group, which uses DS12B20 Maxim sensors, a bus 1-wire, and a recording device based on a conventional Arduino board. Temperature was registered every 5 min across several years. These measurements were used to thermally characterize the subsoil, determining the apparent thermal diffusivity, and to study the thermo-hydrogeology of the Lower Jurassic Gijón’s formation made of Liassic limestones and dolomites. This work is part of the Q-Thermie group’s research called “Shallow Thermal Energy”.
Open AccessA Device to Register Temperature in Boreholes in Northwest Spain for Geothermal Research
This paper presents a device used to measure and register temperature for long-term subsoil measurements in boreholes. The borehole of this study is located in Gijón (Asturias, Spain). The measurements were made through two fixed sets of sensors coupled to the geothermal pipe, constituting two independent installations: (a) a commercial device called “Hobo”, which uses TMCx-HD-specific sensors based on resistors with variable resistance; and (b) a device built by this research group, which uses DS12B20 Maxim sensors, a bus 1-wire, and a recording device based on a conventional Arduino board. Temperature was registered every 5 min across several years. These measurements were used to thermally characterize the subsoil, determining the apparent thermal diffusivity, and to study the thermo-hydrogeology of the Lower Jurassic Gijón’s formation made of Liassic limestones and dolomites. This work is part of the Q-Thermie group’s research called “Shallow Thermal Energy”.
- 1 July 2020
- Published by Elsevier in Geothermics
- Vol. 86, 101821
Study of shallow subsoil temperature and its relationship to thermal diffusivity
- 1 July 2020
- Published by Elsevier in Geothermics
- Vol. 86, 101821
Study of shallow subsoil temperature and its relationship to thermal diffusivity
- Open Access
- 6 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1461
Analysis Technique by Laser-Induced Breakdown Spectroscopy of Powder Mineral and Slurry Samples
In this article, the results of a methodology to perform the elemental analysis of samples from mining borehole samples using the Laser-Induced Breakdown Spectroscopy (LIBS) technique are presented. The developed method can be carried out either on powder and on slurry samples, which would comparable to the samples obtained in a mineral processing plant.
- 6 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1461
Open AccessAnalysis Technique by Laser-Induced Breakdown Spectroscopy of Powder Mineral and Slurry Samples
In this article, the results of a methodology to perform the elemental analysis of samples from mining borehole samples using the Laser-Induced Breakdown Spectroscopy (LIBS) technique are presented. The developed method can be carried out either on powder and on slurry samples, which would comparable to the samples obtained in a mineral processing plant.
- Open Access
- 6 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1460
Determination of the Theoretical Spectrum of Gamma Emission Generated by DGNAA in Samples of Ashes of Thermal Power Plants
In this article the methodology for the determination of the theoretical gamma spectrum originated by applying DGNAA (delayed gamma neutron analysis activation) techniques for the elemental analysis of ash from thermal power plants is exposed. This is a study must be prior to the experimentation in order to define the parameters of the test to obtain the optimal conditions for the detection of each element present in the sample.
- 6 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1460
Open AccessDetermination of the Theoretical Spectrum of Gamma Emission Generated by DGNAA in Samples of Ashes of Thermal Power Plants
In this article the methodology for the determination of the theoretical gamma spectrum originated by applying DGNAA (delayed gamma neutron analysis activation) techniques for the elemental analysis of ash from thermal power plants is exposed. This is a study must be prior to the experimentation in order to define the parameters of the test to obtain the optimal conditions for the detection of each element present in the sample.
- Open Access
- 5 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1497
Study of the Thermal Conductivity of Different Geothermal Grouting Materials with a Homemade Apparatus
Thermal conductivity is an essential property of the geothermal grout, which in turn is considered the most important element in a vertical closed-loop ground heat exchanger. The main aim of this work is to determine the thermal conductivity of four of the most commonly used geothermal grouting materials using a homemade apparatus, developed by the research team. The tests were also performed with a commercial thermal conductivity meter, the Shotherm QTM-F1. Both the homemade apparatus, called MCT, and the commercial thermal conductivity meter are based on the transient hot wire method. The components used to make the specimens are cement, silica sand, bentonite, water and superplasticizer. A laboratory mortar mixer was used to prepare all mixtures. Later, the samples were cured in a water bath for 7 days and finally the samples were dried at 60 °C for 24 h before testing. Each of the samples tested is formed of two solid rectangular prisms of the same material and of the same dimensions (180 mm × 70 mm × 50 mm). The obtained results with the MCT apparatus are similar to the data reported in the literature and to those obtained using the Shotherm QTM-F1thermal conductivity meter. The deviations of the values measured with the MCT apparatus are, in all cases, less than 10%.
- 5 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1497
Open AccessStudy of the Thermal Conductivity of Different Geothermal Grouting Materials with a Homemade Apparatus
Thermal conductivity is an essential property of the geothermal grout, which in turn is considered the most important element in a vertical closed-loop ground heat exchanger. The main aim of this work is to determine the thermal conductivity of four of the most commonly used geothermal grouting materials using a homemade apparatus, developed by the research team. The tests were also performed with a commercial thermal conductivity meter, the Shotherm QTM-F1. Both the homemade apparatus, called MCT, and the commercial thermal conductivity meter are based on the transient hot wire method. The components used to make the specimens are cement, silica sand, bentonite, water and superplasticizer. A laboratory mortar mixer was used to prepare all mixtures. Later, the samples were cured in a water bath for 7 days and finally the samples were dried at 60 °C for 24 h before testing. Each of the samples tested is formed of two solid rectangular prisms of the same material and of the same dimensions (180 mm × 70 mm × 50 mm). The obtained results with the MCT apparatus are similar to the data reported in the literature and to those obtained using the Shotherm QTM-F1thermal conductivity meter. The deviations of the values measured with the MCT apparatus are, in all cases, less than 10%.
- Open Access
- 5 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1496
Design, Construction and Commissioning of an Apparatus for Measuring the Thermal Conductivity of Geothermal Grouting Materials Based on the Transient Hot Wire Method
The aim of the present study is to develop an apparatus for the measurement of the thermal conductivity of geothermal grouting materials. The apparatus, named MCT, is designed and constructed as a direct application of a mathematical model of heat transference for conduction in an infinite homogeneous isotropic medium using a linear heat source of infinite length, infinitesimal radius and radial heat flow. This application is known as the transient hot wire method. The apparatus mainly consists of a hot wire, a power supply, a temperature sensor and a datalogger. The commissioning of the developed apparatus is carried out by means of the calibration of the temperature sensor, as well as measurements of thermal conductivity using four reference samples whose thermal conductivity is known. Each of the reference samples is formed of two solid rectangular prisms of the same material and of the same dimensions. MCT is precise and accurate. In good experimental conditions the uncertainty of the measurements is within 10%. In addition, the MCT apparatus is light and with reduced dimensions.
- 5 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (23) , 1496
Open AccessDesign, Construction and Commissioning of an Apparatus for Measuring the Thermal Conductivity of Geothermal Grouting Materials Based on the Transient Hot Wire Method
The aim of the present study is to develop an apparatus for the measurement of the thermal conductivity of geothermal grouting materials. The apparatus, named MCT, is designed and constructed as a direct application of a mathematical model of heat transference for conduction in an infinite homogeneous isotropic medium using a linear heat source of infinite length, infinitesimal radius and radial heat flow. This application is known as the transient hot wire method. The apparatus mainly consists of a hot wire, a power supply, a temperature sensor and a datalogger. The commissioning of the developed apparatus is carried out by means of the calibration of the temperature sensor, as well as measurements of thermal conductivity using four reference samples whose thermal conductivity is known. Each of the reference samples is formed of two solid rectangular prisms of the same material and of the same dimensions. MCT is precise and accurate. In good experimental conditions the uncertainty of the measurements is within 10%. In addition, the MCT apparatus is light and with reduced dimensions.