Sun-Ho Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sun-Ho Park has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Daewon Kim
Division of Earth Environmental System Science, Major of Spatial Information Engineering, Pukyong National University, Busan, Republic of Korea
1 shared publication - Dukhyeon Kim
School of Basic Science, Hanbat National University, 125, Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea
1 shared publication - Hanlim Lee
Professor, Major of Spatial Information Engineering, Division of Earth Environmental System Sciences, Pukyong National University, Busan, Republic of Korea
1 shared publication - Hyeongwoo Kang
Division of Earth Environmental System Science Major of Spatial Information Engineering, Pukyong National University, Busan 48513, Korea
1 shared publication - Jae-Yong Ryu
Department of Urban Environmental Engineering, Kyungnam University, Changwon-si, Gyeongsangnam-do 631-701, Korea
1 shared publication - MoonSang Yoon
SOLETOP Co., Ltd., 409 Expo-ro, Yuseong-gu, Daejeon 34051, Korea
1 shared publication
Latest Publications
- Open Access
- 18 June 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (6) , 729
Fiber Lidar for Control of the Ecological State of the Atmosphere
Methods and means of remote control of the ecological state of the atmosphere are constantly improving. Lidar sensing allows obtaining up-to-date information about natural and technogenic sources of atmospheric pollution. There is a wide range of problems in ecological control, where the deployment of an inexpensive mobile lidar network is required. For this purpose, it is suggested to use Q-switch and MOPA fiber lasers in lidars. Q-switch fiber lasers have a simpler design and are more practical to use. However, pulses from Q-switch lasers have long full-pulse durations. In the present work, a lidar signal inversion method (LSIM) is proposed for solving this problem. Verification and outdoor experimentation of the LSIM was carried out with the reference signal method (RSM). The advantage of the proposed RSM is the minimum number of controllable parameters necessary for LSIM verification and approbation. As a result, the accuracy of the obtained results increased. Thus, the possibility of application of the Q-switch fiber lasers for lidar sensing is shown both theoretically and experimentally.
- 18 June 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (6) , 729
Open AccessFiber Lidar for Control of the Ecological State of the Atmosphere
Methods and means of remote control of the ecological state of the atmosphere are constantly improving. Lidar sensing allows obtaining up-to-date information about natural and technogenic sources of atmospheric pollution. There is a wide range of problems in ecological control, where the deployment of an inexpensive mobile lidar network is required. For this purpose, it is suggested to use Q-switch and MOPA fiber lasers in lidars. Q-switch fiber lasers have a simpler design and are more practical to use. However, pulses from Q-switch lasers have long full-pulse durations. In the present work, a lidar signal inversion method (LSIM) is proposed for solving this problem. Verification and outdoor experimentation of the LSIM was carried out with the reference signal method (RSM). The advantage of the proposed RSM is the minimum number of controllable parameters necessary for LSIM verification and approbation. As a result, the accuracy of the obtained results increased. Thus, the possibility of application of the Q-switch fiber lasers for lidar sensing is shown both theoretically and experimentally.
- Open Access
- 9 September 2018
- Published by MDPI AG in Remote Sensing
- Vol. 10 (9) , 1439
Development of Raman Lidar for Remote Sensing of CO2 Leakage at an Artificial Carbon Capture and Storage Site
We developed a Raman lidar system that can remotely detect CO2 leakage and its volume mixing ratio (VMR). The system consists of a laser, a telescope, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar is 99.89%. Field measurements were carried out over a four-day period in November 2017 at the Eumsong Environmental Impact Evaluation Test Facility (EIT), Korea, where a CO2 leak was located 0.2 km from the Raman lidar. The results show good agreement between CO2 VMR measured by the Raman lidar system (CO2 VMRRaman LIDAR) and that measured by in situ instruments (CO2 VMRIn-situ). The correlation coefficient (R), mean absolute error (MAE), root mean square error (RMSE), and percentage difference between CO2 VMRIn-situ and CO2 VMRRaman LIDAR are 0.81, 0.27%, 0.37%, and 4.92%, respectively. The results indicate that Raman lidar is an effective tool in detecting CO2 leakage and in measuring CO2 VMR remotely.
- 9 September 2018
- Published by MDPI AG in Remote Sensing
- Vol. 10 (9) , 1439
Open AccessDevelopment of Raman Lidar for Remote Sensing of CO2 Leakage at an Artificial Carbon Capture and Storage Site
We developed a Raman lidar system that can remotely detect CO2 leakage and its volume mixing ratio (VMR). The system consists of a laser, a telescope, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar is 99.89%. Field measurements were carried out over a four-day period in November 2017 at the Eumsong Environmental Impact Evaluation Test Facility (EIT), Korea, where a CO2 leak was located 0.2 km from the Raman lidar. The results show good agreement between CO2 VMR measured by the Raman lidar system (CO2 VMRRaman LIDAR) and that measured by in situ instruments (CO2 VMRIn-situ). The correlation coefficient (R), mean absolute error (MAE), root mean square error (RMSE), and percentage difference between CO2 VMRIn-situ and CO2 VMRRaman LIDAR are 0.81, 0.27%, 0.37%, and 4.92%, respectively. The results indicate that Raman lidar is an effective tool in detecting CO2 leakage and in measuring CO2 VMR remotely.