Dejiang Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dejiang Lu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
6 shared publications Ping Yang
State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi'an Jiaotong University, Xi'an, China
4 shared publicationsQijing Lin
State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi'an Jiaotong University, Xi'an, China
2 shared publicationsWei Li
State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi’an Jiaotong University, Xi’an, China
2 shared publicationsXiaozhang Wang
State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi'an Jiaotong University, Xi'an, China
2 shared publications- Zhikang Li
School of Instrument Science and Technology Xi'an Jiaotong University Xi'an China
2 shared publications
Latest Publications
- Open Access
- 5 June 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Tesla-scale magnetic field measurement based on Sideband-overlap Zeeman spectroscopy using a functionalized MEMS vapor cell
Accurate measurement of strong magnetic fields in the Tesla range remains a persistent challenge due to calibration drift, nonlinearity, and spatial gradient sensitivity. Here, we present a compact magnetometry approach based on sideband-overlap Zeeman spectroscopy, enabled by a functionalized MEMS cesium vapor cell. The vapor cell features a dual-chamber glass–Si–glass structure with integrated microheaters on the optical window. A first-order electro-optic modulator produces optical sidebands aligned with the σ+ and Zeeman-split components of the Cs D1 line under the hyperfine Paschen–Back regime. Magnetic field scanning from zero to Tesla-scale fields enables extraction of the frequency offset between reference and Zeeman-shifted spectra. This frequency shift is directly converted into magnetic field strength using Zeeman spectroscopy in the hyperfine Paschen–Back regime. The method resolves sixteen Zeeman transitions (eight\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$ and eight\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{+}$$ ), allowing measurement of a field strength of 0.6694921 T, with a single-shot resolution of 6.4 μT and a cross-transition repeatability of σB = 8.9 μT (corresponding to 13 ppm at 0.6695 T). In a millimeter-scale sensing volume, the system achieves sub-10 μT repeatability without requiring a uniform bias field. These results indicate that the microfabricated high-field magnetometer can serve as a compact and practical approach for Tesla-range field measurement and pave the way for chip-scale quantum devices.\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$ - 5 June 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Open AccessTesla-scale magnetic field measurement based on Sideband-overlap Zeeman spectroscopy using a functionalized MEMS vapor cell
Accurate measurement of strong magnetic fields in the Tesla range remains a persistent challenge due to calibration drift, nonlinearity, and spatial gradient sensitivity. Here, we present a compact magnetometry approach based on sideband-overlap Zeeman spectroscopy, enabled by a functionalized MEMS cesium vapor cell. The vapor cell features a dual-chamber glass–Si–glass structure with integrated microheaters on the optical window. A first-order electro-optic modulator produces optical sidebands aligned with the σ+ and Zeeman-split components of the Cs D1 line under the hyperfine Paschen–Back regime. Magnetic field scanning from zero to Tesla-scale fields enables extraction of the frequency offset between reference and Zeeman-shifted spectra. This frequency shift is directly converted into magnetic field strength using Zeeman spectroscopy in the hyperfine Paschen–Back regime. The method resolves sixteen Zeeman transitions (eight\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$ and eight\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{+}$$ ), allowing measurement of a field strength of 0.6694921 T, with a single-shot resolution of 6.4 μT and a cross-transition repeatability of σB = 8.9 μT (corresponding to 13 ppm at 0.6695 T). In a millimeter-scale sensing volume, the system achieves sub-10 μT repeatability without requiring a uniform bias field. These results indicate that the microfabricated high-field magnetometer can serve as a compact and practical approach for Tesla-range field measurement and pave the way for chip-scale quantum devices.\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} $${{\rm{\sigma }}}^{-}$$ - Open Access
- 11 May 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Development of a novel radially-distributed spiral bilayer thermopile infrared sensor with enhanced responsivity
Current trend of pursuing higher resolution in uncooled cost-effective infrared imagers demands thermopile sensing units with higher responsivity. Conventional designs often have limitations such as non-uniform temperature distribution among individual thermocouple legs or complex fabrication process, which limit further responsivity improvement. Here, a novel thermopile featuring a radially-distributed spiral structure with bilayer P-poly/Al thermocouples is proposed. The radially distributed legs along with the circular membrane effectively improve the temperature uniformity among individual thermocouples. Meanwhile, the spiral bilayer configuration decreases thermal conductance and increases the thermocouple number simultaneously, resulting in a significant enhancement of the responsivity. The spiral parameter was designed and optimized, and the fabricated sensors were characterized and compared with conventional non-spiral thermopiles. Experimental results demonstrate a responsivity of 52.53 V/W and a specific detectivity of 9.76 × 107 cm·Hz1/2·W-1 for the proposed sensor, representing a 39.35% and 17.81% enhancement over the 37.70 V/W and 8.29 × 107 cm·Hz1/2·W-1 achieved by the non-spiral counterpart. With its high responsivity and CMOS-compatible fabrication, the proposed thermopile offers a cost-effective solution for next-generation, high-resolution infrared imagers.
- 11 May 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Open AccessDevelopment of a novel radially-distributed spiral bilayer thermopile infrared sensor with enhanced responsivity
Current trend of pursuing higher resolution in uncooled cost-effective infrared imagers demands thermopile sensing units with higher responsivity. Conventional designs often have limitations such as non-uniform temperature distribution among individual thermocouple legs or complex fabrication process, which limit further responsivity improvement. Here, a novel thermopile featuring a radially-distributed spiral structure with bilayer P-poly/Al thermocouples is proposed. The radially distributed legs along with the circular membrane effectively improve the temperature uniformity among individual thermocouples. Meanwhile, the spiral bilayer configuration decreases thermal conductance and increases the thermocouple number simultaneously, resulting in a significant enhancement of the responsivity. The spiral parameter was designed and optimized, and the fabricated sensors were characterized and compared with conventional non-spiral thermopiles. Experimental results demonstrate a responsivity of 52.53 V/W and a specific detectivity of 9.76 × 107 cm·Hz1/2·W-1 for the proposed sensor, representing a 39.35% and 17.81% enhancement over the 37.70 V/W and 8.29 × 107 cm·Hz1/2·W-1 achieved by the non-spiral counterpart. With its high responsivity and CMOS-compatible fabrication, the proposed thermopile offers a cost-effective solution for next-generation, high-resolution infrared imagers.
- Open Access
- 14 April 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Theoretical modelling and optimization design of PMUT arrays for enhanced acoustic performance
Theoretical models are essential for performance analysis and structure optimization design of large-scale piezoelectric micromachined ultrasonic transducers (PMUT) arrays. However, current models have rarely incorporated the inter-element crosstalk and oversimplified the electro-mechanical-acoustic coupling, leading serious discrepancies with experimental results and limiting the array optimization design and performance improvement. To address this, a novel electro-mechanical-acoustic coupling model and a spatial acoustic field modeling approach are proposed for PMUT arrays, incorporating distributed deformation functions of individual element and mutual acoustic impedance to analyse key performance metrics such as transmission power, frequency response, focal length, and beamwidth. Its accuracy is validated through finite element simulations, demonstrating small deviations of less than 3%. Parametric studies reveal that increasing the filling ratio from 20% to 60% improves transmission power and bandwidth but significantly increases crosstalk, reducing focusing efficiency. Enlarging the array size results in proportional increases in acoustic output power and focal pressure, while simultaneously reducing beamwidth, thereby improving directivity. As for array arrangements, circular array achieves higher focal pressure than square array, albeit with shorter focal lengths. Annular array, with its distinct mainlobe and ring-shaped sidelobes, demonstrates superior focal pressure at longer distances, ideal for extended-range applications. The theoretical models are further validated by experimental results from fabricated square, hexagonal, circular, and annular PMUT arrays. This study proposes an accurate theoretical model for PMUT arrays, enabling accurate and reliable prediction of key acoustic performance metrics in large-scale arrays, and facilitating the array structure optimization design and performance enhancement of PMUT.
- 14 April 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Open AccessTheoretical modelling and optimization design of PMUT arrays for enhanced acoustic performance
Theoretical models are essential for performance analysis and structure optimization design of large-scale piezoelectric micromachined ultrasonic transducers (PMUT) arrays. However, current models have rarely incorporated the inter-element crosstalk and oversimplified the electro-mechanical-acoustic coupling, leading serious discrepancies with experimental results and limiting the array optimization design and performance improvement. To address this, a novel electro-mechanical-acoustic coupling model and a spatial acoustic field modeling approach are proposed for PMUT arrays, incorporating distributed deformation functions of individual element and mutual acoustic impedance to analyse key performance metrics such as transmission power, frequency response, focal length, and beamwidth. Its accuracy is validated through finite element simulations, demonstrating small deviations of less than 3%. Parametric studies reveal that increasing the filling ratio from 20% to 60% improves transmission power and bandwidth but significantly increases crosstalk, reducing focusing efficiency. Enlarging the array size results in proportional increases in acoustic output power and focal pressure, while simultaneously reducing beamwidth, thereby improving directivity. As for array arrangements, circular array achieves higher focal pressure than square array, albeit with shorter focal lengths. Annular array, with its distinct mainlobe and ring-shaped sidelobes, demonstrates superior focal pressure at longer distances, ideal for extended-range applications. The theoretical models are further validated by experimental results from fabricated square, hexagonal, circular, and annular PMUT arrays. This study proposes an accurate theoretical model for PMUT arrays, enabling accurate and reliable prediction of key acoustic performance metrics in large-scale arrays, and facilitating the array structure optimization design and performance enhancement of PMUT.
- Open Access
- 7 April 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 122
Piezoelectric stepped-plate resonators vibrating at lateral modes for direct viscosity determination in liquids
Precise viscosity measurement in liquid media remains a critical challenge for micromachined resonant sensors. This primarily results from the inherent coupling between viscosity and density in hydrodynamic interactions, which limits independent quantification of viscosity. This work presents an aluminum nitride (AlN) piezoelectric microresonator vibrating at in-plane lateral mode for direct viscosity sensing in liquids. The resonator features cantilevered dual-plate structure with a wide step to leverage width-dependent effects on resonant frequency and quality factor. Through fluid-structure interaction modeling, the resonator is optimized to enhance vibrational characteristics while increasing linearity with respect to liquid viscosity. In experiments, the resonator incorporates fully electrical interfaces by combining self-actuation and self-sensing capabilities under liquid immersion. Furthermore, a significantly linear relationship between the quality factor and liquid viscosity is demonstrated. This linearity enables direct viscosity quantification through simultaneously measuring the resonant frequency and quality factor, which eliminates the need for prior density calibration required by conventional methods. The fabricated resonator achieves a mean absolute relative deviation of 2.65% with a maximum stability deviation of 3.43%. These results establish microplate-based laterally vibrating resonators as promising solutions for high-precision viscosity determination in compact liquid monitoring systems.
- 7 April 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 122
Open AccessPiezoelectric stepped-plate resonators vibrating at lateral modes for direct viscosity determination in liquids
Precise viscosity measurement in liquid media remains a critical challenge for micromachined resonant sensors. This primarily results from the inherent coupling between viscosity and density in hydrodynamic interactions, which limits independent quantification of viscosity. This work presents an aluminum nitride (AlN) piezoelectric microresonator vibrating at in-plane lateral mode for direct viscosity sensing in liquids. The resonator features cantilevered dual-plate structure with a wide step to leverage width-dependent effects on resonant frequency and quality factor. Through fluid-structure interaction modeling, the resonator is optimized to enhance vibrational characteristics while increasing linearity with respect to liquid viscosity. In experiments, the resonator incorporates fully electrical interfaces by combining self-actuation and self-sensing capabilities under liquid immersion. Furthermore, a significantly linear relationship between the quality factor and liquid viscosity is demonstrated. This linearity enables direct viscosity quantification through simultaneously measuring the resonant frequency and quality factor, which eliminates the need for prior density calibration required by conventional methods. The fabricated resonator achieves a mean absolute relative deviation of 2.65% with a maximum stability deviation of 3.43%. These results establish microplate-based laterally vibrating resonators as promising solutions for high-precision viscosity determination in compact liquid monitoring systems.
- Open Access
- 2 April 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-12
Piezoelectric-AlN resonators at two-dimensional flexural modes for the density and viscosity decoupled determination of liquids
A micromachined resonator immersed in liquid provides valuable resonance parameters for determining the fluidic parameters. However, the liquid operating environment poses a challenge to maintaining a fine sensing performance, particularly through electrical characterization. This paper presents a piezoelectric micromachined cantilever with a stepped shape for liquid monitoring purposes. Multiple modes of the proposed cantilever are available with full electrical characterization for realizing self-actuated and self-sensing capabilities. The focus is on higher flexural resonances, which nonconventionally feature two-dimensional vibration modes. Modal analyses are conducted for the developed cantilever under flexural vibrations at different orders. Modeling explains not only the basic length-dominant mode but also higher modes that simultaneously depend on the length and width of the cantilever. This study determines that the analytical predictions for resonant frequency in liquid media exhibit good agreement with the experimental results. Furthermore, the experiments on cantilever resonators are performed in various test liquids, demonstrating that higher-order flexural modes allow for the decoupled measurements of density and viscosity. The measurement differences achieve 0.39% in density and 3.50% in viscosity, and the frequency instability is below 0.05‰. On the basis of these results, design guidelines for piezoelectric higher-mode resonators are proposed for liquid sensing.
- 2 April 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-12
Open AccessPiezoelectric-AlN resonators at two-dimensional flexural modes for the density and viscosity decoupled determination of liquids
A micromachined resonator immersed in liquid provides valuable resonance parameters for determining the fluidic parameters. However, the liquid operating environment poses a challenge to maintaining a fine sensing performance, particularly through electrical characterization. This paper presents a piezoelectric micromachined cantilever with a stepped shape for liquid monitoring purposes. Multiple modes of the proposed cantilever are available with full electrical characterization for realizing self-actuated and self-sensing capabilities. The focus is on higher flexural resonances, which nonconventionally feature two-dimensional vibration modes. Modal analyses are conducted for the developed cantilever under flexural vibrations at different orders. Modeling explains not only the basic length-dominant mode but also higher modes that simultaneously depend on the length and width of the cantilever. This study determines that the analytical predictions for resonant frequency in liquid media exhibit good agreement with the experimental results. Furthermore, the experiments on cantilever resonators are performed in various test liquids, demonstrating that higher-order flexural modes allow for the decoupled measurements of density and viscosity. The measurement differences achieve 0.39% in density and 3.50% in viscosity, and the frequency instability is below 0.05‰. On the basis of these results, design guidelines for piezoelectric higher-mode resonators are proposed for liquid sensing.
- Open Access
Application and Optimization of Stiffness Abruption Structures for Pressure Sensors with High Sensitivity and Anti-Overload Ability
The influence of diaphragm bending stiffness distribution on the stress concentration characteristics of a pressure sensing chip had been analyzed and discussed systematically. According to the analysis, a novel peninsula-island-based diaphragm structure was presented and applied to two differenet diaphragm shapes as sensing chips for pressure sensors. By well-designed bending stiffness distribution of the diaphragm, the elastic potential energy induced by diaphragm deformation was concentrated above the gap position, which remarkably increased the sensitivity of the sensing chip. An optimization method and the distribution pattern of the peninsula-island based diaphragm structure were also discussed. Two kinds of sensing chips combined with the peninsula-island structures distributing along the side edge and diagonal directions of rectangular diaphragm were fabricated and analyzed. By bonding the sensing chips with anti-overload glass bases, these two sensing chips were demonstrated by testing to achieve not only high sensitivity, but also good anti-overload ability. The experimental results showed that the proposed structures had the potential to measure ultra-low absolute pressures with high sensitivity and good anti-overload ability in an atmospheric environment.
Open AccessApplication and Optimization of Stiffness Abruption Structures for Pressure Sensors with High Sensitivity and Anti-Overload Ability
The influence of diaphragm bending stiffness distribution on the stress concentration characteristics of a pressure sensing chip had been analyzed and discussed systematically. According to the analysis, a novel peninsula-island-based diaphragm structure was presented and applied to two differenet diaphragm shapes as sensing chips for pressure sensors. By well-designed bending stiffness distribution of the diaphragm, the elastic potential energy induced by diaphragm deformation was concentrated above the gap position, which remarkably increased the sensitivity of the sensing chip. An optimization method and the distribution pattern of the peninsula-island based diaphragm structure were also discussed. Two kinds of sensing chips combined with the peninsula-island structures distributing along the side edge and diagonal directions of rectangular diaphragm were fabricated and analyzed. By bonding the sensing chips with anti-overload glass bases, these two sensing chips were demonstrated by testing to achieve not only high sensitivity, but also good anti-overload ability. The experimental results showed that the proposed structures had the potential to measure ultra-low absolute pressures with high sensitivity and good anti-overload ability in an atmospheric environment.