Shang-Min Yeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shang-Min Yeh has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chi-Hung Lee
Department of Electrical Engineering, Feng Chia University, Taichung 407, Taiwan
2 shared publications - Shuan-Yu Huang
Department of Optometry, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
2 shared publications - Chi-Ting Horng
Department of Pharmacy, Tajen University, Pingtung 907, Taiwan
1 shared publication - Ching-Wen Huang
Department of Ophthalmology, Fu Jen Catholic University Hospital, New Taipei City 242, Taiwan
1 shared publication - Han-Yin Sun
Department of Optometry, Chung Shan Medical University, Taichung City, Taiwan
1 shared publication - Hsiang-Jui Liu
Department of Optometry, Mackay Junior College of Medicine, Nursing, and Management, New Taipei 11260, Taiwan
1 shared publication
Latest Publications
- Open Access
- 8 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1769
Wearable Sports Vision Training May Improve Selected Visuomotor Outcomes and Hitting Precision in Collegiate Badminton Athletes: A Randomized Controlled Trial
Background: High-level badminton performance requires rapid perceptual processing, visuomotor coordination, and precise movement responses under continuously changing spatial conditions. Although wearable sports vision interventions have shown potential for enhancing perceptual–motor performance, evidence regarding their longitudinal effects and transfer to sport-specific outcomes remains limited. Trial design: A single-center, exploratory randomized controlled trial using a parallel-group structure. Simple randomization without blocking or stratification resulted in a final allocation ratio of 16:10 (approximately 1.6:1) between the training and control groups. Methods: Twenty-six collegiate badminton athletes aged 18–25 were randomized into a wearable sports vision training group (n = 16) or a control group (n = 10). The intervention group completed wearable sports vision training using Automatic Dual Rotational Risley Prisms (ADRRPs) for 15 min twice weekly over 4 weeks. Results: Baseline-adjusted ANCOVA demonstrated significant between-group effects for reaction time (p = 0.003) and target-zone accurate hits (p = 0.004), whereas binocular visual function outcomes did not show statistically significant between-group differences. No adverse events were reported. Conclusions: Four weeks of wearable sports vision training may be associated with improvements in selected visuomotor outcomes, particularly reaction performance and target-zone hitting accuracy, in collegiate badminton players. Larger trials are needed to evaluate long-term retention and broader sport-specific applicability. Trial registration: ClinicalTrials.gov Identifier: NCT07105462, registered 29 July 2025.
- 8 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1769
Open AccessWearable Sports Vision Training May Improve Selected Visuomotor Outcomes and Hitting Precision in Collegiate Badminton Athletes: A Randomized Controlled Trial
Background: High-level badminton performance requires rapid perceptual processing, visuomotor coordination, and precise movement responses under continuously changing spatial conditions. Although wearable sports vision interventions have shown potential for enhancing perceptual–motor performance, evidence regarding their longitudinal effects and transfer to sport-specific outcomes remains limited. Trial design: A single-center, exploratory randomized controlled trial using a parallel-group structure. Simple randomization without blocking or stratification resulted in a final allocation ratio of 16:10 (approximately 1.6:1) between the training and control groups. Methods: Twenty-six collegiate badminton athletes aged 18–25 were randomized into a wearable sports vision training group (n = 16) or a control group (n = 10). The intervention group completed wearable sports vision training using Automatic Dual Rotational Risley Prisms (ADRRPs) for 15 min twice weekly over 4 weeks. Results: Baseline-adjusted ANCOVA demonstrated significant between-group effects for reaction time (p = 0.003) and target-zone accurate hits (p = 0.004), whereas binocular visual function outcomes did not show statistically significant between-group differences. No adverse events were reported. Conclusions: Four weeks of wearable sports vision training may be associated with improvements in selected visuomotor outcomes, particularly reaction performance and target-zone hitting accuracy, in collegiate badminton players. Larger trials are needed to evaluate long-term retention and broader sport-specific applicability. Trial registration: ClinicalTrials.gov Identifier: NCT07105462, registered 29 July 2025.
- Open Access
- 1 June 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (6) , 46
High-Color-Temperature Lighting Is Associated With Activation of MAPK/ERK–nNOS Signaling and MMP-2–Related Pathways in Ocular Tissues
To investigate whether exposure to artificial lighting with different correlated color temperatures (CCTs) affects ocular structure and myopia-related molecular signaling pathways before axial elongation in a murine model. C57BL/6 mice were exposed to standard lighting (control) or artificial lighting at 3000, 4000, or 6000 K under a 12-hour light/12-hour dark cycle for 21 days. Spectral power distribution and illuminance were recorded. Histological analyses were performed to assess corneal epithelial thickness, retinal outer and inner nuclear layers (ONL and INL), and sclera thickness. Western blotting was used to evaluate phosphorylated extracellular signal-regulated kinase 1/2 (p-ERK1/2), neuronal nitric oxide synthase (nNOS), matrix metalloproteinase-2 (MMP-2), TNF-α, and IL-6. Immunohistochemistry was performed to assess ionized calcium-binding adapter molecule 1 (Iba-1) immunoreactivity in retinal tissues. Exposure to different CCTs did not affect systemic growth, axial length, or ocular structural integrity. Axial length was comparable across groups (P = 0.431), and no significant differences were observed in sclera thickness, ONL, INL, or corneal epithelial thickness. In contrast, molecular analyses revealed CCT-dependent alterations. Exposure to 6000 K lighting increased p-ERK1/2, nNOS, MMP-2, TNF-α, and IL-6 expression and elevated Iba-1 immunoreactivity in retinal tissues. High-CCT lighting is associated with alterations in myopia-related molecular signaling in the absence of detectable structural or axial changes. These findings highlight early, pre-structural molecular responses to spectral light environments and suggest that CCT influences myopia-relevant pathways before overt ocular remodeling occurs.
- 1 June 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (6) , 46
Open AccessHigh-Color-Temperature Lighting Is Associated With Activation of MAPK/ERK–nNOS Signaling and MMP-2–Related Pathways in Ocular Tissues
To investigate whether exposure to artificial lighting with different correlated color temperatures (CCTs) affects ocular structure and myopia-related molecular signaling pathways before axial elongation in a murine model. C57BL/6 mice were exposed to standard lighting (control) or artificial lighting at 3000, 4000, or 6000 K under a 12-hour light/12-hour dark cycle for 21 days. Spectral power distribution and illuminance were recorded. Histological analyses were performed to assess corneal epithelial thickness, retinal outer and inner nuclear layers (ONL and INL), and sclera thickness. Western blotting was used to evaluate phosphorylated extracellular signal-regulated kinase 1/2 (p-ERK1/2), neuronal nitric oxide synthase (nNOS), matrix metalloproteinase-2 (MMP-2), TNF-α, and IL-6. Immunohistochemistry was performed to assess ionized calcium-binding adapter molecule 1 (Iba-1) immunoreactivity in retinal tissues. Exposure to different CCTs did not affect systemic growth, axial length, or ocular structural integrity. Axial length was comparable across groups (P = 0.431), and no significant differences were observed in sclera thickness, ONL, INL, or corneal epithelial thickness. In contrast, molecular analyses revealed CCT-dependent alterations. Exposure to 6000 K lighting increased p-ERK1/2, nNOS, MMP-2, TNF-α, and IL-6 expression and elevated Iba-1 immunoreactivity in retinal tissues. High-CCT lighting is associated with alterations in myopia-related molecular signaling in the absence of detectable structural or axial changes. These findings highlight early, pre-structural molecular responses to spectral light environments and suggest that CCT influences myopia-relevant pathways before overt ocular remodeling occurs.
- Open Access
Innovative Binocular Vision Testing for Phoria and Vergence Ranges Using Automatic Dual Rotational Risley Prisms
This study evaluated binocular visual function using automatic dual rotational Risley prisms (ADRRPs) to measure phoria and vergence ranges. Thirty-nine (mean age: 21.82 ± 1.10 years; age range: 20–24 years) healthy adults with normal binocular vision participated. Each underwent baseline refraction exams followed by phoria and vergence tests conducted using both a phoropter with Maddox rods and the ADRRPs. The results revealed a strong positive correlation between the two instruments for distance phoria (r = 0.959, p < 0.001) and near-phoria measurements (r = 0.968, p < 0.001). For vergence testing, positive fusional vergence (PFV) at distance showed a moderate-to-strong correlation for break points (r = 0.758, p < 0.001) and a moderate correlation for recovery points (r = 0.452, p < 0.001). Negative fusional vergence (NFV) at distance demonstrated a strong correlation for break points (r = 0.863, p < 0.001) and a moderate correlation for recovery points (r = 0.458, p < 0.01). Near-vergence testing showed moderate-to-strong correlations for break points (r = 0.777, p < 0.001) and recovery points (r = 0.623, p < 0.001). The inclusion of Bland–Altman analysis provides a more comprehensive evaluation of agreement between ADRRPs and the phoropter. While strong correlations were observed, systematic bias and LoA indicate that these methods are not perfectly interchangeable. The ADRRPs demonstrated potential for binocular vision assessment but require further validation for clinical application.
Open AccessInnovative Binocular Vision Testing for Phoria and Vergence Ranges Using Automatic Dual Rotational Risley Prisms
This study evaluated binocular visual function using automatic dual rotational Risley prisms (ADRRPs) to measure phoria and vergence ranges. Thirty-nine (mean age: 21.82 ± 1.10 years; age range: 20–24 years) healthy adults with normal binocular vision participated. Each underwent baseline refraction exams followed by phoria and vergence tests conducted using both a phoropter with Maddox rods and the ADRRPs. The results revealed a strong positive correlation between the two instruments for distance phoria (r = 0.959, p < 0.001) and near-phoria measurements (r = 0.968, p < 0.001). For vergence testing, positive fusional vergence (PFV) at distance showed a moderate-to-strong correlation for break points (r = 0.758, p < 0.001) and a moderate correlation for recovery points (r = 0.452, p < 0.001). Negative fusional vergence (NFV) at distance demonstrated a strong correlation for break points (r = 0.863, p < 0.001) and a moderate correlation for recovery points (r = 0.458, p < 0.01). Near-vergence testing showed moderate-to-strong correlations for break points (r = 0.777, p < 0.001) and recovery points (r = 0.623, p < 0.001). The inclusion of Bland–Altman analysis provides a more comprehensive evaluation of agreement between ADRRPs and the phoropter. While strong correlations were observed, systematic bias and LoA indicate that these methods are not perfectly interchangeable. The ADRRPs demonstrated potential for binocular vision assessment but require further validation for clinical application.
- Open Access
- 19 November 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (11) , 14800-14810
Predicting the Incidence of Human Cataract through Retinal Imaging Technology
With the progress of science, technology and medicine, the proportion of elderly people in society has gradually increased over the years. Thus, the medical care and health issues of this population have drawn increasing attention. In particular, among the common medical problems of the elderly, the occurrence of cataracts has been widely observed. In this study, we developed retinal imaging technology by establishing a human eye module with ray tracing. Periodic hole arrays with different degrees were constructed on the anterior surface of the lens to emulate the eyesight decline caused by cataracts. Then, we successfully predicted the incidence of cataracts among people with myopia ranging from −3.0 D to −9.0 D. Results show that periodic hole arrays cause severe eyesight decline when they are centralized in the visual center. However, the wide distribution of these arrays on the anterior surface of the lens would not significantly affect one’s eyesight.
- 19 November 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (11) , 14800-14810
Open AccessPredicting the Incidence of Human Cataract through Retinal Imaging Technology
With the progress of science, technology and medicine, the proportion of elderly people in society has gradually increased over the years. Thus, the medical care and health issues of this population have drawn increasing attention. In particular, among the common medical problems of the elderly, the occurrence of cataracts has been widely observed. In this study, we developed retinal imaging technology by establishing a human eye module with ray tracing. Periodic hole arrays with different degrees were constructed on the anterior surface of the lens to emulate the eyesight decline caused by cataracts. Then, we successfully predicted the incidence of cataracts among people with myopia ranging from −3.0 D to −9.0 D. Results show that periodic hole arrays cause severe eyesight decline when they are centralized in the visual center. However, the wide distribution of these arrays on the anterior surface of the lens would not significantly affect one’s eyesight.