Chi-Hung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chi-Hung Lee has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Shuan-Yu Huang
Department of Optometry, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
6 shared publications - Shang-Min Yeh
Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan
3 shared publications - Chen-Cheng Lo
Department of Optometry, Chung Shan Medical University, Taichung 402, Taiwan
2 shared publications Chun-Wei Liu
Power Mechanical Engineering, National Tsing Hua University, Taiwan
2 shared publications- Feng-Chi Lin
Department of Ophthalmology, Kaohsiung Armed Forced General Hospital, Kaohsiung 802, Taiwan
2 shared publications - George C. Woo
School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
2 shared publications
Latest Publications
- Open Access
- 8 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1769
Wearable Sports Vision Training May Improve Selected Visuomotor Outcomes and Hitting Precision in Collegiate Badminton Athletes: A Randomized Controlled Trial
Background: High-level badminton performance requires rapid perceptual processing, visuomotor coordination, and precise movement responses under continuously changing spatial conditions. Although wearable sports vision interventions have shown potential for enhancing perceptual–motor performance, evidence regarding their longitudinal effects and transfer to sport-specific outcomes remains limited. Trial design: A single-center, exploratory randomized controlled trial using a parallel-group structure. Simple randomization without blocking or stratification resulted in a final allocation ratio of 16:10 (approximately 1.6:1) between the training and control groups. Methods: Twenty-six collegiate badminton athletes aged 18–25 were randomized into a wearable sports vision training group (n = 16) or a control group (n = 10). The intervention group completed wearable sports vision training using Automatic Dual Rotational Risley Prisms (ADRRPs) for 15 min twice weekly over 4 weeks. Results: Baseline-adjusted ANCOVA demonstrated significant between-group effects for reaction time (p = 0.003) and target-zone accurate hits (p = 0.004), whereas binocular visual function outcomes did not show statistically significant between-group differences. No adverse events were reported. Conclusions: Four weeks of wearable sports vision training may be associated with improvements in selected visuomotor outcomes, particularly reaction performance and target-zone hitting accuracy, in collegiate badminton players. Larger trials are needed to evaluate long-term retention and broader sport-specific applicability. Trial registration: ClinicalTrials.gov Identifier: NCT07105462, registered 29 July 2025.
- 8 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1769
Open AccessWearable Sports Vision Training May Improve Selected Visuomotor Outcomes and Hitting Precision in Collegiate Badminton Athletes: A Randomized Controlled Trial
Background: High-level badminton performance requires rapid perceptual processing, visuomotor coordination, and precise movement responses under continuously changing spatial conditions. Although wearable sports vision interventions have shown potential for enhancing perceptual–motor performance, evidence regarding their longitudinal effects and transfer to sport-specific outcomes remains limited. Trial design: A single-center, exploratory randomized controlled trial using a parallel-group structure. Simple randomization without blocking or stratification resulted in a final allocation ratio of 16:10 (approximately 1.6:1) between the training and control groups. Methods: Twenty-six collegiate badminton athletes aged 18–25 were randomized into a wearable sports vision training group (n = 16) or a control group (n = 10). The intervention group completed wearable sports vision training using Automatic Dual Rotational Risley Prisms (ADRRPs) for 15 min twice weekly over 4 weeks. Results: Baseline-adjusted ANCOVA demonstrated significant between-group effects for reaction time (p = 0.003) and target-zone accurate hits (p = 0.004), whereas binocular visual function outcomes did not show statistically significant between-group differences. No adverse events were reported. Conclusions: Four weeks of wearable sports vision training may be associated with improvements in selected visuomotor outcomes, particularly reaction performance and target-zone hitting accuracy, in collegiate badminton players. Larger trials are needed to evaluate long-term retention and broader sport-specific applicability. Trial registration: ClinicalTrials.gov Identifier: NCT07105462, registered 29 July 2025.
- Open Access
- 16 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 286
Modeling the Influence of Large Particles on Optical Properties of Nuclear Cataracts: Insights from Enhanced LOCS III-Based Computational Analysis
Background: Nuclear cataracts cause visual degradation through light scattering by aggregated proteins and particles within the crystalline lens. Existing computational models mainly consider submicron scatterers, while the optical impact of micrometer-scale particles observed in human nuclear cataracts remains underexplored. Objective: This study extends a LOCS III–based computational cataract model by incorporating micrometer-scale particles and quantitatively evaluates their effects on forward and backward light scattering across nuclear cataract grades. Methods: A physics-based scattering model was implemented using optical simulation software (LightTools). Three particle populations—nanometer-scale (S-type), submicron-scale (M-type), and micrometer-scale (L-type)—were uniformly distributed within the lens. Retinal luminance reduction was analyzed for forward scattering, while slit-lamp-based backward scattering simulations were used to evaluate luminance distributions and chromaticity changes. Particle concentrations were varied within clinically reported ranges corresponding to LOCS III grades. Results: Micrometer-scale particles had minimal impact in early nuclear cataract grades but significantly increased forward scattering and luminance loss in advanced grades (NO5–NO6). Backward scattering simulations revealed pronounced luminance enhancement and yellow chromaticity shifts with increasing micrometer-scale particle concentration. One micrometer-scale particle produced a luminance-reduction effect equivalent to approximately 6–7 submicron particles, depending on cataract severity. Conclusions: Including micrometer-scale particles enables a more complete optical representation of nuclear cataracts, linking retinal image degradation with slit-lamp appearance. The model provides a physically grounded framework for offline analysis and reference data generation to support clinical interpretation of cataract grading.
- 16 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (2) , 286
Open AccessModeling the Influence of Large Particles on Optical Properties of Nuclear Cataracts: Insights from Enhanced LOCS III-Based Computational Analysis
Background: Nuclear cataracts cause visual degradation through light scattering by aggregated proteins and particles within the crystalline lens. Existing computational models mainly consider submicron scatterers, while the optical impact of micrometer-scale particles observed in human nuclear cataracts remains underexplored. Objective: This study extends a LOCS III–based computational cataract model by incorporating micrometer-scale particles and quantitatively evaluates their effects on forward and backward light scattering across nuclear cataract grades. Methods: A physics-based scattering model was implemented using optical simulation software (LightTools). Three particle populations—nanometer-scale (S-type), submicron-scale (M-type), and micrometer-scale (L-type)—were uniformly distributed within the lens. Retinal luminance reduction was analyzed for forward scattering, while slit-lamp-based backward scattering simulations were used to evaluate luminance distributions and chromaticity changes. Particle concentrations were varied within clinically reported ranges corresponding to LOCS III grades. Results: Micrometer-scale particles had minimal impact in early nuclear cataract grades but significantly increased forward scattering and luminance loss in advanced grades (NO5–NO6). Backward scattering simulations revealed pronounced luminance enhancement and yellow chromaticity shifts with increasing micrometer-scale particle concentration. One micrometer-scale particle produced a luminance-reduction effect equivalent to approximately 6–7 submicron particles, depending on cataract severity. Conclusions: Including micrometer-scale particles enables a more complete optical representation of nuclear cataracts, linking retinal image degradation with slit-lamp appearance. The model provides a physically grounded framework for offline analysis and reference data generation to support clinical interpretation of cataract grading.
- Open Access
Innovative Binocular Vision Testing for Phoria and Vergence Ranges Using Automatic Dual Rotational Risley Prisms
This study evaluated binocular visual function using automatic dual rotational Risley prisms (ADRRPs) to measure phoria and vergence ranges. Thirty-nine (mean age: 21.82 ± 1.10 years; age range: 20–24 years) healthy adults with normal binocular vision participated. Each underwent baseline refraction exams followed by phoria and vergence tests conducted using both a phoropter with Maddox rods and the ADRRPs. The results revealed a strong positive correlation between the two instruments for distance phoria (r = 0.959, p < 0.001) and near-phoria measurements (r = 0.968, p < 0.001). For vergence testing, positive fusional vergence (PFV) at distance showed a moderate-to-strong correlation for break points (r = 0.758, p < 0.001) and a moderate correlation for recovery points (r = 0.452, p < 0.001). Negative fusional vergence (NFV) at distance demonstrated a strong correlation for break points (r = 0.863, p < 0.001) and a moderate correlation for recovery points (r = 0.458, p < 0.01). Near-vergence testing showed moderate-to-strong correlations for break points (r = 0.777, p < 0.001) and recovery points (r = 0.623, p < 0.001). The inclusion of Bland–Altman analysis provides a more comprehensive evaluation of agreement between ADRRPs and the phoropter. While strong correlations were observed, systematic bias and LoA indicate that these methods are not perfectly interchangeable. The ADRRPs demonstrated potential for binocular vision assessment but require further validation for clinical application.
Open AccessInnovative Binocular Vision Testing for Phoria and Vergence Ranges Using Automatic Dual Rotational Risley Prisms
This study evaluated binocular visual function using automatic dual rotational Risley prisms (ADRRPs) to measure phoria and vergence ranges. Thirty-nine (mean age: 21.82 ± 1.10 years; age range: 20–24 years) healthy adults with normal binocular vision participated. Each underwent baseline refraction exams followed by phoria and vergence tests conducted using both a phoropter with Maddox rods and the ADRRPs. The results revealed a strong positive correlation between the two instruments for distance phoria (r = 0.959, p < 0.001) and near-phoria measurements (r = 0.968, p < 0.001). For vergence testing, positive fusional vergence (PFV) at distance showed a moderate-to-strong correlation for break points (r = 0.758, p < 0.001) and a moderate correlation for recovery points (r = 0.452, p < 0.001). Negative fusional vergence (NFV) at distance demonstrated a strong correlation for break points (r = 0.863, p < 0.001) and a moderate correlation for recovery points (r = 0.458, p < 0.01). Near-vergence testing showed moderate-to-strong correlations for break points (r = 0.777, p < 0.001) and recovery points (r = 0.623, p < 0.001). The inclusion of Bland–Altman analysis provides a more comprehensive evaluation of agreement between ADRRPs and the phoropter. While strong correlations were observed, systematic bias and LoA indicate that these methods are not perfectly interchangeable. The ADRRPs demonstrated potential for binocular vision assessment but require further validation for clinical application.
- Open Access
- 18 October 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (6) , 3361-3372
Immediate Effects of Vergence Exercises Using Automatic Dual Rotational Risley Prisms on Accommodative Lag and Facility
Introduction This study evaluated novel automatic dual rotational Risley prisms (ADRRPs) as a vergence exercise tool for patients with myopia to improve accommodative lag and accommodative facility. Methods Participants with myopia aged 20–24 years were recruited. After vergence exercises with prisms (treatment group) or plano lenses (control group) using ADRRPs for 10 min, measurements were taken using an open-field autorefractor (Grand Seiko WAM-5500) at viewing distances of 0.4 m and 6.0 m. We measured accommodative facility using a ± 2.00 D accommodative flipper. Results A total of 56 participants (treatment group, 39; control group, 17) performed vergence exercises using ADRRPs. Participants in the treatment group showed improvements in accommodative lag at a 0.4 m viewing distance, with measurements of 0.57 D (right eye; OD) and 0.53 D (left eye; OS) and 0.21 D (OD) and 0.27 D (OS) before and after the exercises, respectively (p < 0.001). Over-refractions using an open-field autorefractor with spherical equivalent contact lenses at a 6.0 m viewing distance were − 0.01 ± 0.30 D (OD) and 0.03 ± 0.34 D (OS) and 0.15 ± 0.32 D (OD) and 0.19 ± 0.28 D (OS) before and after the exercises, respectively (difference + 0.16 D; p < 0.001). Accommodative facility values before and after exercises were 14.88 ± 3.36 and 15.59 ± 3.60 cpm, respectively (p < 0.01). No significant differences in accommodative lag, relaxation, and accommodative facility before and after exercise were observed in the control group. Conclusions Using ADRRPs in vergence exercises can improve accommodative lag, accommodative facility, and accommodative relaxation in adults with myopia. Further research to evaluate persistent and long-term effects is needed.
- 18 October 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (6) , 3361-3372
Open AccessImmediate Effects of Vergence Exercises Using Automatic Dual Rotational Risley Prisms on Accommodative Lag and Facility
Introduction This study evaluated novel automatic dual rotational Risley prisms (ADRRPs) as a vergence exercise tool for patients with myopia to improve accommodative lag and accommodative facility. Methods Participants with myopia aged 20–24 years were recruited. After vergence exercises with prisms (treatment group) or plano lenses (control group) using ADRRPs for 10 min, measurements were taken using an open-field autorefractor (Grand Seiko WAM-5500) at viewing distances of 0.4 m and 6.0 m. We measured accommodative facility using a ± 2.00 D accommodative flipper. Results A total of 56 participants (treatment group, 39; control group, 17) performed vergence exercises using ADRRPs. Participants in the treatment group showed improvements in accommodative lag at a 0.4 m viewing distance, with measurements of 0.57 D (right eye; OD) and 0.53 D (left eye; OS) and 0.21 D (OD) and 0.27 D (OS) before and after the exercises, respectively (p < 0.001). Over-refractions using an open-field autorefractor with spherical equivalent contact lenses at a 6.0 m viewing distance were − 0.01 ± 0.30 D (OD) and 0.03 ± 0.34 D (OS) and 0.15 ± 0.32 D (OD) and 0.19 ± 0.28 D (OS) before and after the exercises, respectively (difference + 0.16 D; p < 0.001). Accommodative facility values before and after exercises were 14.88 ± 3.36 and 15.59 ± 3.60 cpm, respectively (p < 0.01). No significant differences in accommodative lag, relaxation, and accommodative facility before and after exercise were observed in the control group. Conclusions Using ADRRPs in vergence exercises can improve accommodative lag, accommodative facility, and accommodative relaxation in adults with myopia. Further research to evaluate persistent and long-term effects is needed.
- Open Access
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (6) , 1-7
Lens Opacities Classification System III-Based Computational Model of Nuclear Cataracts
This study developed a computational model to assess the optical properties of nuclear cataracts, using slit-lamp lens images for clinical evaluation based on color and opacity. Cataracts were represented as spherical particles distinct from the surrounding lens medium, with diameters ranging from tens to hundreds of nanometers. This study examined the effects of particle diameter, concentration, and colorimetric properties on the opacity of cataracts and their relationship with images on the retina. The findings indicate that particle size and concentration influence opacity. To ensure alignment with the Lens Opacities Classification System III, colors were defined based on a color absorption coefficient limited within a predetermined range. The developed model was used to simulate the yellow-tinted vision experienced by patients with nuclear cataracts.
- 26 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (6) , 1-7
Open AccessLens Opacities Classification System III-Based Computational Model of Nuclear Cataracts
This study developed a computational model to assess the optical properties of nuclear cataracts, using slit-lamp lens images for clinical evaluation based on color and opacity. Cataracts were represented as spherical particles distinct from the surrounding lens medium, with diameters ranging from tens to hundreds of nanometers. This study examined the effects of particle diameter, concentration, and colorimetric properties on the opacity of cataracts and their relationship with images on the retina. The findings indicate that particle size and concentration influence opacity. To ensure alignment with the Lens Opacities Classification System III, colors were defined based on a color absorption coefficient limited within a predetermined range. The developed model was used to simulate the yellow-tinted vision experienced by patients with nuclear cataracts.
- Open Access
- 3 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2942
Effects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System
Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets (p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.
- 3 March 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (5) , 2942
Open AccessEffects of Extended Viewing Distance on Accommodative Response and Pupil Size of Myopic Adults by Using a Double-Mirror System
Purposes: This study discussed the accommodative response and pupil size of myopic adults using a double-mirror system (DMS). The viewing distance could be extended to 2.285 m by using a DMS, which resulted in a reduction and increase in the accommodative response and pupil size, respectively. By using a DMS, the reduction of the accommodative response could improve eye fatigue with near work. Method: Sixty subjects aged between 18 and 22 years old were recruited in this study, and the average age was 20.67 ± 1.09. There were two main steps in the experimental process. In the first step, we examined the subjects’ refraction state and visual function, and then fitted disposable contact lenses with a corresponding refractive error. In the second step, the subjects gazed at an object from a viewing distance of 0.4 m and at a virtual image through a DMS, respectively, and the accommodative response and pupil size were measured using an open field autorefractor. Results: When the subjects gazed at the object from a distance of 0.4 m, or gazed at the virtual image through a DMS, the mean value of the accommodative response was 1.74 ± 0.43 or 0.16 ± 0.47 D, and the pupil size was 3.98 ± 0.06 mm or 4.18 ± 0.58 mm, respectively. With an increase in the viewing distance from 0.4 m to 2.285 m, the accommodative response and pupil size were significantly reduced about 1.58 D and enlarged about 0.2 mm, respectively. For three asterisk targets of different sizes (1 cm × 1 cm, 2 cm × 2 cm, and 3 cm × 3 cm), the mean accommodative response and pupil size through the DMS was 0.19 ± 0.16, 0.27 ± 0.24, 0.26 ± 0.19 D; and 4.20 ± 1.02, 3.94 ± 0.73, 4.21 ± 0.57 mm, respectively. The changes of the accommodative response and pupil size were not significant with the size of the targets (p > 0.05). In the low or high myopia group, the accommodative response of 0.4 m and 2.285 m was 1.68 ± 0.42 D and 0.21 ± 0.48 D; and 1.88 ± 0.25 D and 0.05 ± 0.40 D, respectively. The accommodative response was significantly reduced by 1.47 D and 1.83 D for these two groups. The accommodative microfluctuations (AMFs) were stable when a DMS was used; on the contrary, the AMFs were unstable at a viewing distance of 0.4 m. Conclusions: In this study, the imaging through a DMS extended the viewing distance and enlarged the image, and resulted in a reduction in the accommodative response and an increase in the pupil size. For the low myopia group and the high myopia group, the accommodative response and pupil size were statistically significantly different before and after the use of the DMS. The reduction of the accommodative response could be applied for the improvement of asthenopia.
- Open Access
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (1) , 1-6
Incremental Optical Encoder Based on a Sinusoidal Transmissive Pattern
In this paper, a high-precision rotary encoder based on a sinusoidal transmissive pattern (STP) is proposed for detecting shaft rotation. The STP disk can be realized by coating bell-shaped transmissive area on a transparent glass. We optimize the STP design shape and parameters to achieve sinusoidal transmissive characteristics. The STP-based encoder consists of a light-emitting diode, a STP disk, and a photodetector array. Experimentally, the produced STP disk had a diameter of 60 mm. 256 columns of STPs were arranged on the circumference of this disk to provide a detection pitch of 1.40625°. Each column consisted of 50 bell-shaped STPs. In principle, an incident beam from a blue-ray light emitting diode illuminates the STP of the disk, and the angle of rotation is decoded from the sinusoidal distribution of transmissive spots on the PD. Compared with a conventional incremental rotary encoder, the proposed STP-based encoder achieves a superior angular resolution.
- 23 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (1) , 1-6
Open AccessIncremental Optical Encoder Based on a Sinusoidal Transmissive Pattern
In this paper, a high-precision rotary encoder based on a sinusoidal transmissive pattern (STP) is proposed for detecting shaft rotation. The STP disk can be realized by coating bell-shaped transmissive area on a transparent glass. We optimize the STP design shape and parameters to achieve sinusoidal transmissive characteristics. The STP-based encoder consists of a light-emitting diode, a STP disk, and a photodetector array. Experimentally, the produced STP disk had a diameter of 60 mm. 256 columns of STPs were arranged on the circumference of this disk to provide a detection pitch of 1.40625°. Each column consisted of 50 bell-shaped STPs. In principle, an incident beam from a blue-ray light emitting diode illuminates the STP of the disk, and the angle of rotation is decoded from the sinusoidal distribution of transmissive spots on the PD. Compared with a conventional incremental rotary encoder, the proposed STP-based encoder achieves a superior angular resolution.
- Open Access
- 22 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 9951
Reduction in Accommodative Response of Schoolchildren by a Double-Mirror System
Purpose: This study first proposed the application of a double-mirror system (DMS) to extend viewing distance and investigate the accommodative response of schoolchildren under a DMS. Method: Fifty-seven subjects aged between 7 and 12 years old were recruited in this study, and the experiment was divided into two stages. The first stage consisted of a case history inquiry, a refraction state, and a visual function examination. In the second stage, the subjects gazed at an object at distances of 0.4 m, 2.285 m, and through a DMS, respectively, and their accommodative responses were measured using an open-field autorefractor. Results: There was no significant difference in the schoolchildren’s accommodative response between subjects gazing at an object at 2.285 m (0.14 ± 0.35 D, p > 0.05) and those gazing at it through a DMS (0.20 ± 0.35 D). However, their accommodative response showed a significant difference between subjects gazing at an object at 0.4 m and 2.285 m and those gazing at it at 0.4 m and through a DMS. Conclusion: In this experiment, the results of the children’s accommodative response measured at 2.285 m or through a DMS are very similar. The viewing distance can be extended by a DMS, resulting in accommodative relaxation. This result may have potential applications in myopia control.
- 22 September 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (19) , 9951
Open AccessReduction in Accommodative Response of Schoolchildren by a Double-Mirror System
Purpose: This study first proposed the application of a double-mirror system (DMS) to extend viewing distance and investigate the accommodative response of schoolchildren under a DMS. Method: Fifty-seven subjects aged between 7 and 12 years old were recruited in this study, and the experiment was divided into two stages. The first stage consisted of a case history inquiry, a refraction state, and a visual function examination. In the second stage, the subjects gazed at an object at distances of 0.4 m, 2.285 m, and through a DMS, respectively, and their accommodative responses were measured using an open-field autorefractor. Results: There was no significant difference in the schoolchildren’s accommodative response between subjects gazing at an object at 2.285 m (0.14 ± 0.35 D, p > 0.05) and those gazing at it through a DMS (0.20 ± 0.35 D). However, their accommodative response showed a significant difference between subjects gazing at an object at 0.4 m and 2.285 m and those gazing at it at 0.4 m and through a DMS. Conclusion: In this experiment, the results of the children’s accommodative response measured at 2.285 m or through a DMS are very similar. The viewing distance can be extended by a DMS, resulting in accommodative relaxation. This result may have potential applications in myopia control.
- Open Access
- 30 July 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (8) , 966
The Correlations between Horizontal and Vertical Peripheral Refractions and Human Eye Shape Using Magnetic Resonance Imaging in Highly Myopic Eyes
The aim of this study was to determine the relationship between relative peripheral refraction and retinal shape by 2-D magnetic resonance imaging in high myopes. Thirty-five young adults aged 20 to 30 years participated in this study with 16 high myopes (spherical equivalent < −6.00 D) and 19 emmetropes (+0.50 to −0.50 D). An open field autorefractor was used to measure refractions from the center out to 60° in the horizontal meridian and out to around 20° in the vertical meridian, with a step of 3 degrees. Axial length was measured by using A-scan ultrasonography. In addition, images of axial, sagittal, and tangential sections were obtained using 2-D magnetic resonance imaging. The highly myopic group had a significantly relative peripheral hyperopic refraction and showed a prolate ocular shape compared to the emmetropic group. The highly myopic group had relative peripheral hyperopic refraction and showed a prolate ocular form. Significant differences in the ratios of height/axial (1.01 ± 0.02 vs. 0.94 ± 0.03) and width/axial (0.99 ± 0.17 vs. 0.93 ± 0.04) were found from the MRI images between the emmetropic and the highly myopic eyes (p < 0.001). There was a negative correlation between the retina’s curvature and relative peripheral refraction for both temporal (Pearson r = −0.459; p < 0.01) and nasal (Pearson r = −0.277; p = 0.011) retina. For the highly myopic eyes, the amount of peripheral hyperopic defocus is correlated to its ocular shape deformation. This could be the first study investigating the relationship between peripheral refraction and ocular dimension in high myopes, and it is hoped to provide useful knowledge of how the development of myopia changes human eye shape.
- 30 July 2021
- Published by MDPI AG in Healthcare
- Vol. 9 (8) , 966
Open AccessThe Correlations between Horizontal and Vertical Peripheral Refractions and Human Eye Shape Using Magnetic Resonance Imaging in Highly Myopic Eyes
The aim of this study was to determine the relationship between relative peripheral refraction and retinal shape by 2-D magnetic resonance imaging in high myopes. Thirty-five young adults aged 20 to 30 years participated in this study with 16 high myopes (spherical equivalent < −6.00 D) and 19 emmetropes (+0.50 to −0.50 D). An open field autorefractor was used to measure refractions from the center out to 60° in the horizontal meridian and out to around 20° in the vertical meridian, with a step of 3 degrees. Axial length was measured by using A-scan ultrasonography. In addition, images of axial, sagittal, and tangential sections were obtained using 2-D magnetic resonance imaging. The highly myopic group had a significantly relative peripheral hyperopic refraction and showed a prolate ocular shape compared to the emmetropic group. The highly myopic group had relative peripheral hyperopic refraction and showed a prolate ocular form. Significant differences in the ratios of height/axial (1.01 ± 0.02 vs. 0.94 ± 0.03) and width/axial (0.99 ± 0.17 vs. 0.93 ± 0.04) were found from the MRI images between the emmetropic and the highly myopic eyes (p < 0.001). There was a negative correlation between the retina’s curvature and relative peripheral refraction for both temporal (Pearson r = −0.459; p < 0.01) and nasal (Pearson r = −0.277; p = 0.011) retina. For the highly myopic eyes, the amount of peripheral hyperopic defocus is correlated to its ocular shape deformation. This could be the first study investigating the relationship between peripheral refraction and ocular dimension in high myopes, and it is hoped to provide useful knowledge of how the development of myopia changes human eye shape.
- Open Access
- 29 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (15) , 6979
Accommodative Relaxation by Extending the Viewing Distance through the Simple Optical Design of a Double-Mirror System
Purpose: This paper discusses the accommodative relaxation of myopic adults using a simple double-mirror design. This optical design can extend the viewing distance to 2.285 m and can magnify the image up to 3.386 times, and it results in the accommodative relaxation of a single human eye. By using this optical design, accommodative relaxation may improve eye fatigue and, furthermore, it may delay the progression of myopia. Method: This study recruited 32 subjects with an average age of 20.8 ± 0.95 years old. After an examination of their refractive status, disposable contact lenses with a corresponding refractive error were fitted, and the dynamic accommodative response and change in pupil size were measured by using an open-field autorefractor. The subjects gazed at two different viewing distances. First, they gazed at a real object, which was placed 0.4 m in front of them. Second, the subjects gazed at a virtual image through a double-mirror system at a distance of 2.285 m. The dynamic accommodative responses and pupil size data were collected under these two viewing distance conditions. Results: When the subjects gazed at a real object that was 0.4 m away, or a virtual image that was 2.285 m away, the mean value of the accommodative response was 1.69 ± 0.31 D or 0.11 ± 0.05 D, and the pupil size was 3.79 ± 0.49 mm or 4.09 ± 0.72 mm, respectively. The accommodative response decreased, and the pupil size increased when using the double-mirror system, and therefore, accommodative relaxation can be achieved by using this new optical design. Conclusions: In the present study, we first successfully proposed a simple optical design to relax the accommodation, and the fluctuations of the accommodation response were stable, with an extended viewing distance of 2.285 m. This design may be applied for the improvement of visual function in applications such as the reduction of asthenopia and the control of myopia.
- 29 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (15) , 6979
Open AccessAccommodative Relaxation by Extending the Viewing Distance through the Simple Optical Design of a Double-Mirror System
Purpose: This paper discusses the accommodative relaxation of myopic adults using a simple double-mirror design. This optical design can extend the viewing distance to 2.285 m and can magnify the image up to 3.386 times, and it results in the accommodative relaxation of a single human eye. By using this optical design, accommodative relaxation may improve eye fatigue and, furthermore, it may delay the progression of myopia. Method: This study recruited 32 subjects with an average age of 20.8 ± 0.95 years old. After an examination of their refractive status, disposable contact lenses with a corresponding refractive error were fitted, and the dynamic accommodative response and change in pupil size were measured by using an open-field autorefractor. The subjects gazed at two different viewing distances. First, they gazed at a real object, which was placed 0.4 m in front of them. Second, the subjects gazed at a virtual image through a double-mirror system at a distance of 2.285 m. The dynamic accommodative responses and pupil size data were collected under these two viewing distance conditions. Results: When the subjects gazed at a real object that was 0.4 m away, or a virtual image that was 2.285 m away, the mean value of the accommodative response was 1.69 ± 0.31 D or 0.11 ± 0.05 D, and the pupil size was 3.79 ± 0.49 mm or 4.09 ± 0.72 mm, respectively. The accommodative response decreased, and the pupil size increased when using the double-mirror system, and therefore, accommodative relaxation can be achieved by using this new optical design. Conclusions: In the present study, we first successfully proposed a simple optical design to relax the accommodation, and the fluctuations of the accommodation response were stable, with an extended viewing distance of 2.285 m. This design may be applied for the improvement of visual function in applications such as the reduction of asthenopia and the control of myopia.