Bingtao Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bingtao Hu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Rongkun Wang
College of Information Science and Engineering, Huaqiao University, Xiamen 361021, China
5 shared publications - Fei Man
School of Information Science and Engineering, Huaqiao University, Xiamen, China
2 shared publications - Dong Yan
School of Information Science and Engineering, Huaqiao University, Xiamen, China
1 shared publication - Jie Wang
School of Information Science and Engineering, Huaqiao University, Xiamen, China
1 shared publication Qiyong Chen
School of Information Science and Engineering, Huaqiao University, Xiamen, China
1 shared publication- Qiyong Chen
School of Information Science and Engineering, Huaqiao University, Xiamen, China
1 shared publication
Latest Publications
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Harmonic Detection for Active Power Filter Based on Two-Step Improved EEMD
The performance of active power filter (APF) mainly depends on its harmonic detection method. Empirical mode decomposition (EMD) is applied to APF because of its effectiveness for any complicated signal analysis. Ensemble empirical mode decomposition (EEMD) can suppress mode mixing caused by EMD to a certain extent, but the amplitude and energy of fundamental is severely attenuated. To solve this problem, in this article, the causes of attenuation are discussed from the perspective of intrinsic mode functions (IMFs) energy, and an approach based on two-step improved EEMD is proposed. The first improved step (FI-EEMD) is to suppress the mode mixing and fundamental attenuation by injecting white noise and analytical signal with determined parameters into the target signal. The parameters of the analytical signal are selected according to the power grid conditions and signal characteristics. The second improved step (SI-EEMD) puts forward a signal reconstruction method based on the distribution of IMF energy extreme points and the distinguishing law of signal and noise to reduce the influence of noise-dominated components. The results show that the two-step improved EEMD not only has high-quality extracted fundamental with low total harmonic distortion (THD) and energy attenuation, but also has good applicability to aperiodic and nonstationary signals, which greatly improve the harmonic detection accuracy of APF.
- 27 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Harmonic Detection for Active Power Filter Based on Two-Step Improved EEMD
The performance of active power filter (APF) mainly depends on its harmonic detection method. Empirical mode decomposition (EMD) is applied to APF because of its effectiveness for any complicated signal analysis. Ensemble empirical mode decomposition (EEMD) can suppress mode mixing caused by EMD to a certain extent, but the amplitude and energy of fundamental is severely attenuated. To solve this problem, in this article, the causes of attenuation are discussed from the perspective of intrinsic mode functions (IMFs) energy, and an approach based on two-step improved EEMD is proposed. The first improved step (FI-EEMD) is to suppress the mode mixing and fundamental attenuation by injecting white noise and analytical signal with determined parameters into the target signal. The parameters of the analytical signal are selected according to the power grid conditions and signal characteristics. The second improved step (SI-EEMD) puts forward a signal reconstruction method based on the distribution of IMF energy extreme points and the distinguishing law of signal and noise to reduce the influence of noise-dominated components. The results show that the two-step improved EEMD not only has high-quality extracted fundamental with low total harmonic distortion (THD) and energy attenuation, but also has good applicability to aperiodic and nonstationary signals, which greatly improve the harmonic detection accuracy of APF.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 911-921
Single-Switch Open-Circuit Diagnosis Method Based on Average Voltage Vector for Three-Level T-Type Inverter
Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this paper proposes a novel voltage vector-based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output points is taken as the eigenvector in the method and failed switches can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector and neutral-point potential. These variables have some certain values after circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the method is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed method. Simulations and experiments are carried out to illustrate the superiorities of the method.
- 17 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (1) , 911-921
Single-Switch Open-Circuit Diagnosis Method Based on Average Voltage Vector for Three-Level T-Type Inverter
Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this paper proposes a novel voltage vector-based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output points is taken as the eigenvector in the method and failed switches can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector and neutral-point potential. These variables have some certain values after circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the method is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed method. Simulations and experiments are carried out to illustrate the superiorities of the method.
- 9 March 2020
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 27 (2) , 339-353
Tracking error analysis method of digital pulse power supply for heavy ion accelerator based on emd reconstruction
- 9 March 2020
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 27 (2) , 339-353
Tracking error analysis method of digital pulse power supply for heavy ion accelerator based on emd reconstruction
- Open Access
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165048-165059
Research on Multi-Loop Nonlinear Control Structure and Optimization Method of PMLSM
Recently, the permanent magnet linear synchronous motor (PMLSM) servo control technology has become a research hotspot. However, the control performance under the traditional PID control is not ideal, which usually has the problems of slow response speed, large overshoot and poor anti-interference performance. In addition, adding nonlinear links with certain characteristics purposefully can greatly improve the performance of the system and achieve the expected effect that the traditional linear controllers cannot achieve. Based on this, this paper introduces the nonlinear PID control strategy into the field of servo control, and proposes a nonlinear control strategy of the three-loop of the servo system to improve the above problems. Firstly, the proposed structure is explained and the rule of nonlinear parameters selection is discussed. Secondly, the conditions for the structural stability of the proposed nonlinear control strategy are analyzed. Finally, experiments on the servo system platform are carried out and the results verify the fast dynamic response, precise positioning and good anti-disturbance performance.
- 11 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 165048-165059
Open AccessResearch on Multi-Loop Nonlinear Control Structure and Optimization Method of PMLSM
Recently, the permanent magnet linear synchronous motor (PMLSM) servo control technology has become a research hotspot. However, the control performance under the traditional PID control is not ideal, which usually has the problems of slow response speed, large overshoot and poor anti-interference performance. In addition, adding nonlinear links with certain characteristics purposefully can greatly improve the performance of the system and achieve the expected effect that the traditional linear controllers cannot achieve. Based on this, this paper introduces the nonlinear PID control strategy into the field of servo control, and proposes a nonlinear control strategy of the three-loop of the servo system to improve the above problems. Firstly, the proposed structure is explained and the rule of nonlinear parameters selection is discussed. Secondly, the conditions for the structural stability of the proposed nonlinear control strategy are analyzed. Finally, experiments on the servo system platform are carried out and the results verify the fast dynamic response, precise positioning and good anti-disturbance performance.
- Open Access
- 4 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 73095-73105
Linear Active Disturbance Rejection Control for DC Side Voltage of Single-Phase Active Power Filters
Active power filter (APF) has become an effective approach to suppress harmonic and compensating the reactive power of a power grid. In this paper, the topological structure of the single-phase APF is T-type three-level which can suppress harmonic. For the traditional dual-loop PI control of APF, the voltage loop has poor disturbance rejection performance and long response time under nonlinear load and load mutation. To eliminate the impact on the reduction of power quality of the power grid, this paper uses a PI control of the current loop and a linear active disturbance rejection control (LADRC) of voltage loop. The first-order LADRC controller, which uses a linear extended state observer (ESO) and a linear state error feedback (SEF), does not depend on an explicit mathematical model of the controlled object. In this paper, a 2kVA experimental prototype with a processor of TMS320F28335 is designed to testify the performance and effectiveness of the presented method. The results of simulation and experiments show that the LADRC has better disturbance rejection performance and faster dynamic response than PI control under nonlinear load and load mutation.
- 4 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 73095-73105
Open AccessLinear Active Disturbance Rejection Control for DC Side Voltage of Single-Phase Active Power Filters
Active power filter (APF) has become an effective approach to suppress harmonic and compensating the reactive power of a power grid. In this paper, the topological structure of the single-phase APF is T-type three-level which can suppress harmonic. For the traditional dual-loop PI control of APF, the voltage loop has poor disturbance rejection performance and long response time under nonlinear load and load mutation. To eliminate the impact on the reduction of power quality of the power grid, this paper uses a PI control of the current loop and a linear active disturbance rejection control (LADRC) of voltage loop. The first-order LADRC controller, which uses a linear extended state observer (ESO) and a linear state error feedback (SEF), does not depend on an explicit mathematical model of the controlled object. In this paper, a 2kVA experimental prototype with a processor of TMS320F28335 is designed to testify the performance and effectiveness of the presented method. The results of simulation and experiments show that the LADRC has better disturbance rejection performance and faster dynamic response than PI control under nonlinear load and load mutation.