Abstract
Fault-tolerant control strategy plays a significant role in improving the reliability of three-level T-type inverter where fault diagnosis method is the key and a research hotspot. Load power factor variation and modulation index regulation have great effect on conventional load current based diagnosis methods. Therefore, this paper proposes a novel voltage vector-based method for single-switch open-circuit fault diagnosis in three-level T-type inverter. Average output voltage vector calculated by voltages between dc-link neutral-point and bridge output points is taken as the eigenvector in the method and failed switches can be located by three diagnosis variables including angle of eigenvector, normalized modulus of eigenvector and neutral-point potential. These variables have some certain values after circuit fault, which are defined as eigenvalues. The vector trajectory prediction technology is utilized for threshold setting, by which the method is suitable for different power factors and different modulation indices. The strategy of redundant vector replacement is applied to realize fault-tolerant operation and verifying the proposed method. Simulations and experiments are carried out to illustrate the superiorities of the method.
Funding Information
  • National Natural Science Foundation of China (51707068)
  • Natural Science Foundation of Fujian Province (2017J01097)

This publication has 27 references indexed in Scilit: