Hiroyuki Toyokawa
Research Subjects
Research Interests
Hiroyuki Toyokawa has a total of 660 co-authors. Here are the top co-authors by number of shared publications:
- Hideaki Ohgaki
Institute of Advanced Energy, Kyoto University, Gokasho, Uji 611-0011, Kyoto, Japan
59 shared publications - Hidetoshi Akimune
Konan University
43 shared publications - Ryuunosuke Kuroda
National Institute of Advanced Industrial Science and Technology (AIST)
32 shared publications H. Utsunomiya
Department of Physics, Konan University, Okamoto 8-9-1, Higashinada, Kobe 658-8501, Japan
30 shared publicationsS. Goko
Faculty of Engineering Hokkaido University, Sapporo 060-8628, Japan
30 shared publicationsY.-W. Lui
Cyclotron Institute, Texas A&M University, College Station, Texas 77843, USA
28 shared publications
Latest Publications
- Open Access
- 14 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11866
Fusion Visualization Technique to Improve a Three-Dimensional Isotope-Selective CT Image Based on Nuclear Resonance Fluorescence with a Gamma-CT Image
One of the most noteworthy aspects of computed tomography (CT) based on the nuclear resonance fluorescence (NRF) transmission method is the isotope selectivity that makes it possible to discern an isotope of interest from other isotopes within a sample. We experimentally obtained a three-dimensional (3D) isotope-selective CT image based on the NRF transmission method (3D NRF-CT) for the enriched lead isotope distribution of 208Pb in a cylindrical holder in a previous study. The cylindrical holder’s diameter and height are 25 mm and 20 mm, respectively. The NRF-CT imaging technique requires a considerable data accumulation time. It took 48 h to obtain an image with a resolution of 4 mm/pixel in the horizontal plane and 8 mm/pixel in the vertical plane using a laser Compton scattering (LCS) gamma-ray beam with a beam size of 2 mm and a flux density of 10 photons/s/eV. Improving the NRF-CT image resolution with the existing hardware is challenging. Therefore, we proposed an alternative method to improve the NRF-CT image resolution using the fusion visualization (FV) technique by combining the NRF-CT image including isotopic information with a gamma-CT image, which provides better pixel resolution. The 3D gamma-CT image for the same sample was measured at the same beamline BL1U in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan under similar experimental conditions except for the LCS gamma-ray beam flux and beam size. Obtaining a 3D gamma-CT image with a resolution of 1 mm/pixel took 5 h using an LCS gamma-ray beam with a beam size of 1 mm and a flux density of 0.7 photons/s/eV. The data processing of the FV technique has been developed, and the 3D NRF-CT image quality was improved.
- 14 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11866
Open AccessFusion Visualization Technique to Improve a Three-Dimensional Isotope-Selective CT Image Based on Nuclear Resonance Fluorescence with a Gamma-CT Image
One of the most noteworthy aspects of computed tomography (CT) based on the nuclear resonance fluorescence (NRF) transmission method is the isotope selectivity that makes it possible to discern an isotope of interest from other isotopes within a sample. We experimentally obtained a three-dimensional (3D) isotope-selective CT image based on the NRF transmission method (3D NRF-CT) for the enriched lead isotope distribution of 208Pb in a cylindrical holder in a previous study. The cylindrical holder’s diameter and height are 25 mm and 20 mm, respectively. The NRF-CT imaging technique requires a considerable data accumulation time. It took 48 h to obtain an image with a resolution of 4 mm/pixel in the horizontal plane and 8 mm/pixel in the vertical plane using a laser Compton scattering (LCS) gamma-ray beam with a beam size of 2 mm and a flux density of 10 photons/s/eV. Improving the NRF-CT image resolution with the existing hardware is challenging. Therefore, we proposed an alternative method to improve the NRF-CT image resolution using the fusion visualization (FV) technique by combining the NRF-CT image including isotopic information with a gamma-CT image, which provides better pixel resolution. The 3D gamma-CT image for the same sample was measured at the same beamline BL1U in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan under similar experimental conditions except for the LCS gamma-ray beam flux and beam size. Obtaining a 3D gamma-CT image with a resolution of 1 mm/pixel took 5 h using an LCS gamma-ray beam with a beam size of 1 mm and a flux density of 0.7 photons/s/eV. The data processing of the FV technique has been developed, and the 3D NRF-CT image quality was improved.
- Open Access
- 1 December 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (12) , 125319
Time-domain measurement of coherent transition radiation using a photoconductive antenna with micro-structured electrodes
The longitudinal electric field profile of coherent transition radiation (CTR), which is a radially polarized terahertz (THz) pulse from an electron bunch, was measured using a large-aperture photoconductive antenna (PCA) with a diameter of 8.8 mm and micro-structured concentric electrodes to detect THz light pulses. Photo-induced charge carriers were generated on the PCA by the irradiation of femtosecond laser pulses on the electrode plane. Pulsed light irradiation enabled time-resolved measurement of the THz light pulses, and time-domain measurement of CTR was conducted by measuring the electric-field-induced current output from the PCA by sweeping the timing of the laser irradiation. The frequency spectra obtained from the detected longitudinal electric field profiles of the CTR showed a reasonable response signal from the low-frequency region as low as 0.1 THz. In the present demonstration, the large-aperture PCA-detected THz wave from the CTR was from 0.1 to at least 1 THz. THz generation using the PCA was also performed and measured using a Michelson interferometer with a helium-cooled bolometer. Comparison of the THz pulse of the CTR detected using the PCA and that generated using the PCA revealed that time-domain measurement of the THz pulse using the PCA was limited by the response time of the charge carriers in the semiconductor. Enlargement of the aperture of the PCA enhanced the detectable frequency region toward a lower frequency.
- 1 December 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (12) , 125319
Open AccessTime-domain measurement of coherent transition radiation using a photoconductive antenna with micro-structured electrodes
The longitudinal electric field profile of coherent transition radiation (CTR), which is a radially polarized terahertz (THz) pulse from an electron bunch, was measured using a large-aperture photoconductive antenna (PCA) with a diameter of 8.8 mm and micro-structured concentric electrodes to detect THz light pulses. Photo-induced charge carriers were generated on the PCA by the irradiation of femtosecond laser pulses on the electrode plane. Pulsed light irradiation enabled time-resolved measurement of the THz light pulses, and time-domain measurement of CTR was conducted by measuring the electric-field-induced current output from the PCA by sweeping the timing of the laser irradiation. The frequency spectra obtained from the detected longitudinal electric field profiles of the CTR showed a reasonable response signal from the low-frequency region as low as 0.1 THz. In the present demonstration, the large-aperture PCA-detected THz wave from the CTR was from 0.1 to at least 1 THz. THz generation using the PCA was also performed and measured using a Michelson interferometer with a helium-cooled bolometer. Comparison of the THz pulse of the CTR detected using the PCA and that generated using the PCA revealed that time-domain measurement of the THz pulse using the PCA was limited by the response time of the charge carriers in the semiconductor. Enlargement of the aperture of the PCA enhanced the detectable frequency region toward a lower frequency.
- Open Access
- 10 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3415
Three-Dimensional Nondestructive Isotope-Selective Tomographic Imaging of 208Pb Distribution via Nuclear Resonance Fluorescence
Combining the nuclear resonance fluorescence (NRF) transmission method with computed tomography (CT) can be a novel method for imaging the isotope distributions, which is indispensable in nuclear engineering. We performed an experiment to reconstruct a three-dimensional NRF-CT image with isotope selectivity of enriched lead isotope rods (208Pb) together with a set of different rods, including another enriched isotope (206Pb), iron, and aluminum rods, inserted into a cylindrical aluminum holder. Using a laser Compton scattering (LCS) gamma ray beam with a 5.528 MeV maximum energy, 2 mm beam size, and 10 photon·s−1·eV−1 flux density, which is available at the BL1U beamline in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan, and we excited the Jπ = 1− NRF level at 5.512 MeV in 208Pb. An isotope-selective three-dimensional NRF-CT image of the 208Pb isotope distribution was experimentally obtained for the first time with a pixel resolution of 4 mm in the horizontal plane.
- 10 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (8) , 3415
Open AccessThree-Dimensional Nondestructive Isotope-Selective Tomographic Imaging of 208Pb Distribution via Nuclear Resonance Fluorescence
Combining the nuclear resonance fluorescence (NRF) transmission method with computed tomography (CT) can be a novel method for imaging the isotope distributions, which is indispensable in nuclear engineering. We performed an experiment to reconstruct a three-dimensional NRF-CT image with isotope selectivity of enriched lead isotope rods (208Pb) together with a set of different rods, including another enriched isotope (206Pb), iron, and aluminum rods, inserted into a cylindrical aluminum holder. Using a laser Compton scattering (LCS) gamma ray beam with a 5.528 MeV maximum energy, 2 mm beam size, and 10 photon·s−1·eV−1 flux density, which is available at the BL1U beamline in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan, and we excited the Jπ = 1− NRF level at 5.512 MeV in 208Pb. An isotope-selective three-dimensional NRF-CT image of the 208Pb isotope distribution was experimentally obtained for the first time with a pixel resolution of 4 mm in the horizontal plane.
- 18 June 2019
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 58 (SI) , SIIB10
Characterization of binary Ce–Ir alloy photocathodes
Binary Ce–Ir alloys nominally containing 83, 78, 75, and 67 at% Ir were grown via arc melting in order to clarify the optimum composition for a Ce–Ir system to be used as photocathode material. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD) analysis were employed to characterize the microstructure and phase composition of these alloys. The results of the XRD analyses and SEM/EDX measurements indicated that single-phase homogeneous crystals composed of CeIr 2 grains were successfully grown in the sample with an iridium content amounting to 67 at%. Through quantum efficiency (QE) measurements, it was revealed that the QE of the Ce-67 at% Ir alloy (CeIr 2 phase) is a few times higher than that of the other Ce–Ir alloys.
- 18 June 2019
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 58 (SI) , SIIB10
Characterization of binary Ce–Ir alloy photocathodes
Binary Ce–Ir alloys nominally containing 83, 78, 75, and 67 at% Ir were grown via arc melting in order to clarify the optimum composition for a Ce–Ir system to be used as photocathode material. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD) analysis were employed to characterize the microstructure and phase composition of these alloys. The results of the XRD analyses and SEM/EDX measurements indicated that single-phase homogeneous crystals composed of CeIr 2 grains were successfully grown in the sample with an iridium content amounting to 67 at%. Through quantum efficiency (QE) measurements, it was revealed that the QE of the Ce-67 at% Ir alloy (CeIr 2 phase) is a few times higher than that of the other Ce–Ir alloys.
- Open Access
- 21 February 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 174, 02003
First result of large size Scintillating Glass GEM imager
A large size x-ray imaging gaseous detector, which has 280 × 280 mm2 effective area has been successfully developed and x-ray imaging has been demonstrated. The imaging system consists of a chamber filled with Ne/CF4 scintillating gas mixture, inside of which Glass GEM (G-GEM) is mounted for gas multiplication. In this system electrons are generated by the reaction between x-rays and the gas, and visible photons by excited Ne/CF4 gas molecules during the gas electron multiplication process in the G-GEM holes. These photons are simply detected with CCD-camera and a radiograph is formed. Here, we report on the properties of large size scintillation G-GEM and the results of using it as a digital x-ray imager with a large sensitive area.
- 21 February 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 174, 02003
Open AccessFirst result of large size Scintillating Glass GEM imager
A large size x-ray imaging gaseous detector, which has 280 × 280 mm2 effective area has been successfully developed and x-ray imaging has been demonstrated. The imaging system consists of a chamber filled with Ne/CF4 scintillating gas mixture, inside of which Glass GEM (G-GEM) is mounted for gas multiplication. In this system electrons are generated by the reaction between x-rays and the gas, and visible photons by excited Ne/CF4 gas molecules during the gas electron multiplication process in the G-GEM holes. These photons are simply detected with CCD-camera and a radiograph is formed. Here, we report on the properties of large size scintillation G-GEM and the results of using it as a digital x-ray imager with a large sensitive area.
- 1 December 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (12) , C12050
Fine-pitch glass GEM for high-resolution X-ray imaging
- 1 December 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (12) , C12050
Fine-pitch glass GEM for high-resolution X-ray imaging
- Open Access
- 7 September 2016
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 55 (10) , 106401
High-photon-yield scintillation detector with Ar/CF4 and glass gas electron multiplier
The glass made gas electron multiplier (GEM) and Ar/CF4-gas-based gaseous detector is developed as a scintillation detector and ultra high photon yield is demonstrated. The light yield of a glass GEM (G-GEM)-based gaseous detector is estimated to be 85,000 photons/keV, which is three orders of magnitude brighter than inorganic scintillators. The radioluminescence spectrum peak appeared at around 620 nm, which matches the spectral response of commonly used photosensors such as photomultiplier tubes, photodiodes, CMOSs, CCDs, and other photo-sensors. In X-ray spectroscopy, the light yield showed excellent proportionality and the device was successfully operated as a gas proportional scintillation counter. With this design, we obtained a high photon yield of the G-GEM, which has the further advantage of being much more sensitive to low-energy radiation than solid-scintillator-based detectors.
- 7 September 2016
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 55 (10) , 106401
Open AccessHigh-photon-yield scintillation detector with Ar/CF4 and glass gas electron multiplier
The glass made gas electron multiplier (GEM) and Ar/CF4-gas-based gaseous detector is developed as a scintillation detector and ultra high photon yield is demonstrated. The light yield of a glass GEM (G-GEM)-based gaseous detector is estimated to be 85,000 photons/keV, which is three orders of magnitude brighter than inorganic scintillators. The radioluminescence spectrum peak appeared at around 620 nm, which matches the spectral response of commonly used photosensors such as photomultiplier tubes, photodiodes, CMOSs, CCDs, and other photo-sensors. In X-ray spectroscopy, the light yield showed excellent proportionality and the device was successfully operated as a gas proportional scintillation counter. With this design, we obtained a high photon yield of the G-GEM, which has the further advantage of being much more sensitive to low-energy radiation than solid-scintillator-based detectors.
- Open Access
- 1 June 2016
- Published by Elsevier in Energy Procedia
- Vol. 89, 335-345
Generation of High Energy Gamma-ray by Laser Compton Scattering of 1.94-μm Fiber Laser in UVSOR-III Electron Storage Ring
- 1 June 2016
- Published by Elsevier in Energy Procedia
- Vol. 89, 335-345
Open AccessGeneration of High Energy Gamma-ray by Laser Compton Scattering of 1.94-μm Fiber Laser in UVSOR-III Electron Storage Ring