Shupeng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shupeng Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Shilong Pan
Nanjing University of Aeronautics and Astronautics
10 shared publications - Ting Qing
Key Laboratory of Radar Imaging and Microwave Photonics, Ministry of Education, Nanjing University of Aeronautics and Astronautics, Nanjing, China
6 shared publications - Xiangchuan Wang
Nanjing University of Aeronautics and Astronautics
5 shared publications - Lihan Wang
Nanjing University of Aeronautics and Astronautics
3 shared publications Meihui Cao
Key Laboratory of Radar Imaging and Microwave Photonics, Ministry of Education, Nanjing University of Aeronautics and Astronautics, Nanjing, China
3 shared publications- Min Xue
Nanjing University of Aeronautics and Astronautics
3 shared publications
Latest Publications
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (2) , 579-587
Coherent Optical Phase-Derived Ranging With High Sensitivity and Accuracy
Optical transfer delay (OTD) measurement enables the high performance of distributed coherent radar and optically controlled phase arrays. However, achieving high-accuracy and large-range OTD measurement in photonic integrated chips, outdoor free-space optics, and optical links with significant insertion loss is challenging. This article proposes a coherent optical phase-derived ranging (PDR) system to enhance the OTD measurement sensitivity. In the experiments, the stability of the coherent system was improved 35 times compared to the incoherent system when measuring an optical device with an insertion loss of 30 dB. The sensitivity of the proposed system reaches −80 dBm, which is 46 dB better than the commercial PDR-based product. In addition, the error introduced by the Doppler effect was eliminated with the proposed demodulation method, enabling OTD measurement of a variable optical link.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (2) , 579-587
Coherent Optical Phase-Derived Ranging With High Sensitivity and Accuracy
Optical transfer delay (OTD) measurement enables the high performance of distributed coherent radar and optically controlled phase arrays. However, achieving high-accuracy and large-range OTD measurement in photonic integrated chips, outdoor free-space optics, and optical links with significant insertion loss is challenging. This article proposes a coherent optical phase-derived ranging (PDR) system to enhance the OTD measurement sensitivity. In the experiments, the stability of the coherent system was improved 35 times compared to the incoherent system when measuring an optical device with an insertion loss of 30 dB. The sensitivity of the proposed system reaches −80 dBm, which is 46 dB better than the commercial PDR-based product. In addition, the error introduced by the Doppler effect was eliminated with the proposed demodulation method, enabling OTD measurement of a variable optical link.
- 20 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (3) , 145-148
Wideband Optical Vector Analysis Based on Microwave Photonic Frequency Downconversion
A high-resolution optical vector analyzer (OVA) with wide measurement bandwidth based on microwave photonic frequency downconversion is proposed and experimentally demonstrated. In the proposed OVA, two pairs of frequency-swept dual-tone signals with different frequency intervals are used as the probe light. After passing through a device under test (DUT), the probe light is transmitted into a low-speed photodetector to perform frequency downconversion. Then, an intermediate frequency (IF) photocurrent with a fixed frequency is generated, which carries the DUT response. Hence, a low-speed electrical phase-magnitude detector (EPMD) can be employed to extract the magnitude and group delay responses of the DUT. Compared with the OVAs using the high-speed PD and ultrawide EPMD, the proposed approach is low-cost and has a high signal-to-noise ratio. In an experiment, the probe light is generated by the 2nd-order nonlinearity of the electro-optic modulator. Therefore, compared with conventional OVAs based on optical single-sideband (OSSB) or optical double-sideband (ODSB) modulation, the proposed OVA can achieve wide measurement bandwidth, which is four times (or two times) of that of the OSSB-based OVA (or the ODSB-based OVA). A frequency resolution of 6 MHz and a measurement bandwidth of 120 GHz are achieved.
- 20 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (3) , 145-148
Wideband Optical Vector Analysis Based on Microwave Photonic Frequency Downconversion
A high-resolution optical vector analyzer (OVA) with wide measurement bandwidth based on microwave photonic frequency downconversion is proposed and experimentally demonstrated. In the proposed OVA, two pairs of frequency-swept dual-tone signals with different frequency intervals are used as the probe light. After passing through a device under test (DUT), the probe light is transmitted into a low-speed photodetector to perform frequency downconversion. Then, an intermediate frequency (IF) photocurrent with a fixed frequency is generated, which carries the DUT response. Hence, a low-speed electrical phase-magnitude detector (EPMD) can be employed to extract the magnitude and group delay responses of the DUT. Compared with the OVAs using the high-speed PD and ultrawide EPMD, the proposed approach is low-cost and has a high signal-to-noise ratio. In an experiment, the probe light is generated by the 2nd-order nonlinearity of the electro-optic modulator. Therefore, compared with conventional OVAs based on optical single-sideband (OSSB) or optical double-sideband (ODSB) modulation, the proposed OVA can achieve wide measurement bandwidth, which is four times (or two times) of that of the OSSB-based OVA (or the ODSB-based OVA). A frequency resolution of 6 MHz and a measurement bandwidth of 120 GHz are achieved.
- 5 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 33 (11) , 581-584
High-Resolution Optical Vector Analysis With Enhanced Sensitivity
High-resolution and high-sensitivity optical vector analysis (OVA) is highly desired by many applications, such as optical sensors and photonic integrated circuits (PICs). However, it is difficult to achieve high resolution and high sensitivity simultaneously. Here, we propose and experimentally demonstrate a high sensitivity OVA using coherent detection to achieve the complex frequency responses (including magnitude and phase responses) of a device under test (DUT). Carrier phase noise (CPN) cancellation is employed to eliminate the carrier phase fluctuation induced by the coherent detection. In an experiment, the frequency responses of a fiber Bragg grating (FBG) is accurately measured by the proposed method when the probe light is suppressed by ~18 dB. As a comparison, the method using coherent detection without CPN cancellation can only achieve the magnitude response, and the method using direct detection cannot obtain an effective measurement. The influence of the linewidth and time delay on the measurement is discussed. The proposed OVA provides a stable, high resolution, high sensitivity and low cost approach for characterizing optical devices with arbitrary response, especially for optical devices with large loss or bandpass response.
- 5 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 33 (11) , 581-584
High-Resolution Optical Vector Analysis With Enhanced Sensitivity
High-resolution and high-sensitivity optical vector analysis (OVA) is highly desired by many applications, such as optical sensors and photonic integrated circuits (PICs). However, it is difficult to achieve high resolution and high sensitivity simultaneously. Here, we propose and experimentally demonstrate a high sensitivity OVA using coherent detection to achieve the complex frequency responses (including magnitude and phase responses) of a device under test (DUT). Carrier phase noise (CPN) cancellation is employed to eliminate the carrier phase fluctuation induced by the coherent detection. In an experiment, the frequency responses of a fiber Bragg grating (FBG) is accurately measured by the proposed method when the probe light is suppressed by ~18 dB. As a comparison, the method using coherent detection without CPN cancellation can only achieve the magnitude response, and the method using direct detection cannot obtain an effective measurement. The influence of the linewidth and time delay on the measurement is discussed. The proposed OVA provides a stable, high resolution, high sensitivity and low cost approach for characterizing optical devices with arbitrary response, especially for optical devices with large loss or bandpass response.
- 28 February 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11781, 117810C-61
High-accuracy and stable measurement of optical time delay based on an optical Hilbert transformer
High-accuracy optical time delay measurement is essential to optical beamforming networks, multi-antenna GNSS-overfiber systems, and clock synchronization networks. To meet the demand of high-performance measurement, a time delay measurement system via microwave phase shift analysis is proposed, in which a modulator bias controller (MBC) is employed to stabilize the bias point of Mach-Zehnder modulator. However, because the MBC is easy to lose lock in long-term use, the stability of the measurement system is limited. To overcome the above problem, we propose an enhanced measurement system, in which the intensity modulation is achieved using a phase modulator and an optical Hilbert transformer. To verify the performance of the proposed system, a proof-of-concept experiment is carried out. The measurement results show that an accuracy of ±0.05 ps is obtained.
- 28 February 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11781, 117810C-61
High-accuracy and stable measurement of optical time delay based on an optical Hilbert transformer
High-accuracy optical time delay measurement is essential to optical beamforming networks, multi-antenna GNSS-overfiber systems, and clock synchronization networks. To meet the demand of high-performance measurement, a time delay measurement system via microwave phase shift analysis is proposed, in which a modulator bias controller (MBC) is employed to stabilize the bias point of Mach-Zehnder modulator. However, because the MBC is easy to lose lock in long-term use, the stability of the measurement system is limited. To overcome the above problem, we propose an enhanced measurement system, in which the intensity modulation is achieved using a phase modulator and an optical Hilbert transformer. To verify the performance of the proposed system, a proof-of-concept experiment is carried out. The measurement results show that an accuracy of ±0.05 ps is obtained.
- 23 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (2) , 627-632
High-Accuracy Optical Fiber Transfer Delay Measurement Using Fiber-Optic Microwave Interferometry
Optical fiber transfer delay (OFTD) measurement with high accuracy and stability is an urgent demand for many applications such as fiber-optic sensors and fiber-based distributed systems. In this article, we propose a novel method using fiber-optic microwave interferometry to meet the above practice demand. Two incoherent optical carriers with different wavelengths are coupled into an intensity modulator driven by a microwave signal. The intensity-modulated signal is then divided into two portions through a dense wavelength division multiplexer. One portion directly passes through the reference path while the other undergoes the transfer delay of a fiber under test (FUT). After photo-detection, two probe signals that undergo different delays are recovered and superimposed. By sweeping the microwave frequency, periodic microwave interference fringe is generated. Then, OFTD measurement is achieved by measuring the frequency of the last valley in the interference fringe. Experimental results show that a system stability of ±0.02 ps, an accuracy of ±0.07 ps, and a measurement range of at least 500 m are achieved.
- 23 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 39 (2) , 627-632
High-Accuracy Optical Fiber Transfer Delay Measurement Using Fiber-Optic Microwave Interferometry
Optical fiber transfer delay (OFTD) measurement with high accuracy and stability is an urgent demand for many applications such as fiber-optic sensors and fiber-based distributed systems. In this article, we propose a novel method using fiber-optic microwave interferometry to meet the above practice demand. Two incoherent optical carriers with different wavelengths are coupled into an intensity modulator driven by a microwave signal. The intensity-modulated signal is then divided into two portions through a dense wavelength division multiplexer. One portion directly passes through the reference path while the other undergoes the transfer delay of a fiber under test (FUT). After photo-detection, two probe signals that undergo different delays are recovered and superimposed. By sweeping the microwave frequency, periodic microwave interference fringe is generated. Then, OFTD measurement is achieved by measuring the frequency of the last valley in the interference fringe. Experimental results show that a system stability of ±0.02 ps, an accuracy of ±0.07 ps, and a measurement range of at least 500 m are achieved.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-4
High-Accuracy and Fast Measurement of Optical Transfer Delay
Measurement of optical transfer delay (OTD) is crucial to applications such as fiber-distributed multi-antenna systems, fiber-optic sensors, and high-capacity optical fiber communications. However, present OTD measurement techniques are inadequate for the demands of high accuracy, high speed, and large measurement range, simultaneously. Here, we propose a novel method based on nonlinear frequency sweeping and phase derived ranging to achieve all the above performance. A continuous-wave light modulated by a microwave signal propagates in a device under test. Then, the OTD is mapped into the phase variation of the microwave signal by photo-detection. A microwave phase discriminator is used to extract the phase variation from the microwave signal, while the nonlinear frequency sweeping and a novel phase unwrapping algorithm are proposed to resolve 2π phase ambiguity caused by phase detection. Frequencies of the microwave swept signals are set at four selected points in a range of 10 MHz, which ensures high speed and large measurement range. Our experiment results verify an accuracy of ±0.05 ps in measuring an ultrahigh-accuracy optical delay line. In addition, long fiber is also tested, which proves that a measurement range of at least 37 km (theoretically 100 km) can be achieved. Moreover, the measurement speed reaches milliseconds per measurement.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-4
High-Accuracy and Fast Measurement of Optical Transfer Delay
Measurement of optical transfer delay (OTD) is crucial to applications such as fiber-distributed multi-antenna systems, fiber-optic sensors, and high-capacity optical fiber communications. However, present OTD measurement techniques are inadequate for the demands of high accuracy, high speed, and large measurement range, simultaneously. Here, we propose a novel method based on nonlinear frequency sweeping and phase derived ranging to achieve all the above performance. A continuous-wave light modulated by a microwave signal propagates in a device under test. Then, the OTD is mapped into the phase variation of the microwave signal by photo-detection. A microwave phase discriminator is used to extract the phase variation from the microwave signal, while the nonlinear frequency sweeping and a novel phase unwrapping algorithm are proposed to resolve 2π phase ambiguity caused by phase detection. Frequencies of the microwave swept signals are set at four selected points in a range of 10 MHz, which ensures high speed and large measurement range. Our experiment results verify an accuracy of ±0.05 ps in measuring an ultrahigh-accuracy optical delay line. In addition, long fiber is also tested, which proves that a measurement range of at least 37 km (theoretically 100 km) can be achieved. Moreover, the measurement speed reaches milliseconds per measurement.
- Open Access
- 13 November 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 5135
Optical vector analysis with attometer resolution, 90-dB dynamic range and THz bandwidth
Optical vector analysis (OVA) capable of achieving magnitude and phase responses is essential for the fabrication and application of emerging optical devices. Conventional OVA often has to make compromises among resolution, dynamic range, and bandwidth. Here we show an original method to meet the measurement requirements for ultra-wide bandwidth, ultra-high resolution, and ultra-large dynamic range simultaneously, based on an asymmetric optical probe signal generator (ASG) and receiver (ASR). The ASG and ASR remove the measurement errors introduced by the modulation nonlinearity and enable an ultra-large dynamic range. Thanks to the wavelength-independence of the ASG and ASR, the measurement range can increase by 2 N times by applying an N-tone optical frequency comb without complicated operation. In an experiment, OVA with a resolution of 334 Hz (2.67 attometer in the 1550-nm band), a dynamic range of > 90 dB and a measurement range of 1.075 THz is demonstrated.
- 13 November 2019
- Published by Springer Nature in Nature Communications
- Vol. 10 (1) , 5135
Open AccessOptical vector analysis with attometer resolution, 90-dB dynamic range and THz bandwidth
Optical vector analysis (OVA) capable of achieving magnitude and phase responses is essential for the fabrication and application of emerging optical devices. Conventional OVA often has to make compromises among resolution, dynamic range, and bandwidth. Here we show an original method to meet the measurement requirements for ultra-wide bandwidth, ultra-high resolution, and ultra-large dynamic range simultaneously, based on an asymmetric optical probe signal generator (ASG) and receiver (ASR). The ASG and ASR remove the measurement errors introduced by the modulation nonlinearity and enable an ultra-large dynamic range. Thanks to the wavelength-independence of the ASG and ASR, the measurement range can increase by 2 N times by applying an N-tone optical frequency comb without complicated operation. In an experiment, OVA with a resolution of 334 Hz (2.67 attometer in the 1550-nm band), a dynamic range of > 90 dB and a measurement range of 1.075 THz is demonstrated.
- 3 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 31 (16) , 1351-1354
Optical Fiber Transfer Delay Measurement Based on Phase-Derived Ranging
High accuracy optical fiber transfer delay (OFTD) measurement with a broad measurement range is essential for the development of high-speed or parallel optical devices and systems. In this work, we propose a system for OFTD measurement using phase-derived ranging. A microwave signal is converted into an optical signal, which is transmitted through a fiber under test. After photodetection, the OFTD is converted into the phase shift of the microwave signal, which can be detected using a microwave phase detector. When calculating the OFTD, the phase error is divided by the highest microwave frequency, which ensures high measurement accuracy. The integer ambiguity caused by phase detection can be removed by sweeping the microwave frequency in a range of 1 MHz. An experiment is performed. The measurement of a motorized variable optical delay line and a long fiber shows that a dynamic range of more than 20 kilometers and an accuracy of ±0.1 picoseconds can be achieved with no dead zone.
- 3 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 31 (16) , 1351-1354
Optical Fiber Transfer Delay Measurement Based on Phase-Derived Ranging
High accuracy optical fiber transfer delay (OFTD) measurement with a broad measurement range is essential for the development of high-speed or parallel optical devices and systems. In this work, we propose a system for OFTD measurement using phase-derived ranging. A microwave signal is converted into an optical signal, which is transmitted through a fiber under test. After photodetection, the OFTD is converted into the phase shift of the microwave signal, which can be detected using a microwave phase detector. When calculating the OFTD, the phase error is divided by the highest microwave frequency, which ensures high measurement accuracy. The integer ambiguity caused by phase detection can be removed by sweeping the microwave frequency in a range of 1 MHz. An experiment is performed. The measurement of a motorized variable optical delay line and a long fiber shows that a dynamic range of more than 20 kilometers and an accuracy of ±0.1 picoseconds can be achieved with no dead zone.
- 26 June 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (13) , 3322-3325
Ultrafast and ultrahigh-resolution optical vector analysis using linearly frequency-modulated waveform and dechirp processing
We propose and experimentally demonstrate an ultrafast and ultrahigh-resolution optical vector analyzer (OVA) using linearly frequency-modulated (LFM) waveform and dechirp processing. An optical LFM signal, achieved by modulating an electrical LFM signal on an optical carrier via carrier-suppressed optical single-sideband (OSSB) modulation, is separated into two portions. One portion (denoted as the reference signal) directly goes through the reference path, and the other (denoted as the probe signal) undergoes magnitude and phase changes by an optical device under test (DUT) in the measurement path. After balanced photodetection, the reference signal and the probe signal are mixed to perform a dechirp operation. A relatively low-frequency electrical signal is generated, which can be sampled by a low-speed analog-to-digital converter. As a result, the frequency responses of the DUT can be extracted at a high speed by post digital signal processing. Thanks to the large chirp rate of the electrical LFM signal and the dechirp processing, the proposed LFM-based OVA enables ultrafast measurement speed and ultrahigh frequency resolution. We perform an experiment in which a narrowband tunable optical filter is characterized. The measurement speed reaches 1 ns/point, and the frequency resolution is 1.6 MHz.
- 26 June 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (13) , 3322-3325
Ultrafast and ultrahigh-resolution optical vector analysis using linearly frequency-modulated waveform and dechirp processing
We propose and experimentally demonstrate an ultrafast and ultrahigh-resolution optical vector analyzer (OVA) using linearly frequency-modulated (LFM) waveform and dechirp processing. An optical LFM signal, achieved by modulating an electrical LFM signal on an optical carrier via carrier-suppressed optical single-sideband (OSSB) modulation, is separated into two portions. One portion (denoted as the reference signal) directly goes through the reference path, and the other (denoted as the probe signal) undergoes magnitude and phase changes by an optical device under test (DUT) in the measurement path. After balanced photodetection, the reference signal and the probe signal are mixed to perform a dechirp operation. A relatively low-frequency electrical signal is generated, which can be sampled by a low-speed analog-to-digital converter. As a result, the frequency responses of the DUT can be extracted at a high speed by post digital signal processing. Thanks to the large chirp rate of the electrical LFM signal and the dechirp processing, the proposed LFM-based OVA enables ultrafast measurement speed and ultrahigh frequency resolution. We perform an experiment in which a narrowband tunable optical filter is characterized. The measurement speed reaches 1 ns/point, and the frequency resolution is 1.6 MHz.
- Open Access
- 21 July 2017
- Published by MDPI AG
Length measurement of long optical fiber with sub-millimeter resolution
Knowing the exact length of long optical fiber is of great importance to interferometry-based optical sensors, fiber-connected antenna arrays and other microwave photonic applications. This paper reviews recent efforts on long optical fiber length measurement with sub-millimeter resolution, including optical time domain reflectometers, optical frequency domain reflectometers, and optical backscatter reflectometers based on microwave frequency sweeping. Techniques to improve the measurement resolution and to reduce the measurement error are discussed.
- 21 July 2017
- Published by MDPI AG
Open AccessLength measurement of long optical fiber with sub-millimeter resolution
Knowing the exact length of long optical fiber is of great importance to interferometry-based optical sensors, fiber-connected antenna arrays and other microwave photonic applications. This paper reviews recent efforts on long optical fiber length measurement with sub-millimeter resolution, including optical time domain reflectometers, optical frequency domain reflectometers, and optical backscatter reflectometers based on microwave frequency sweeping. Techniques to improve the measurement resolution and to reduce the measurement error are discussed.