Zhihua Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhihua Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Fenghao Wang
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an, China
3 shared publications - Chao Huan
College of Energy Engineering, Xi’an University of Science and Technology, Xi’an 710054, China
2 shared publications - Kaiwen Xu
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Pengfei Zhang
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Yujia Zhang
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Zhenjun Ma
University of Wollongong
2 shared publications
Latest Publications
- Open Access
Research on Parameter Optimization and Control Strategy of Air Source Heat Pump Coupled with Thermal Energy Storage System
The air source heat pump coupled with energy storage system is a key technology for flexibly utilizing clean energy. The capacity configuration parameters and control strategies of this coupled system are two important aspects that significantly affect its performance. In order to explore the methods of setting configuration parameters and provide reasonable operation strategies, a simulation model of the coupled system under a time-of-use electricity pricing strategy is established and verified with measured data. Through multi-objective optimization of the system, configuration schemes considering economy, energy saving, and flexibility are given. Subsequently, based on the load prediction model, an optimal control strategy is proposed with the objective function of minimizing the operating cost. The optimization amplitude of the schemes considering the three indicators reached 11.09%, 13.37%, and 29.03%, respectively. Under the proposed control strategies, the typical daily electricity consumption decreased by 14.65% to 24.06%, and the operating electricity cost is saved by approximately 17.32%. By reasonably designing the parameters of the coupled system, its economic, energy-saving performance, and flexibility can be improved by more than 11% compared to a system designed using traditional methods. By adopting the control strategy based on hourly load prediction, the operating cost can be reduced significantly.
Open AccessResearch on Parameter Optimization and Control Strategy of Air Source Heat Pump Coupled with Thermal Energy Storage System
The air source heat pump coupled with energy storage system is a key technology for flexibly utilizing clean energy. The capacity configuration parameters and control strategies of this coupled system are two important aspects that significantly affect its performance. In order to explore the methods of setting configuration parameters and provide reasonable operation strategies, a simulation model of the coupled system under a time-of-use electricity pricing strategy is established and verified with measured data. Through multi-objective optimization of the system, configuration schemes considering economy, energy saving, and flexibility are given. Subsequently, based on the load prediction model, an optimal control strategy is proposed with the objective function of minimizing the operating cost. The optimization amplitude of the schemes considering the three indicators reached 11.09%, 13.37%, and 29.03%, respectively. Under the proposed control strategies, the typical daily electricity consumption decreased by 14.65% to 24.06%, and the operating electricity cost is saved by approximately 17.32%. By reasonably designing the parameters of the coupled system, its economic, energy-saving performance, and flexibility can be improved by more than 11% compared to a system designed using traditional methods. By adopting the control strategy based on hourly load prediction, the operating cost can be reduced significantly.
- Open Access
Exergy Analysis of Transcritical CO2 Air-Source Heat Pump with Honeycomb Gas Cooler
In order to build an efficient and energy-saving CO2 heat pump system and to improve the heat transfer efficiency of the gas cooler, a novel honeycomb gas cooler with a compact structure, high heat transfer efficiency, and high pressure-bearing capacity was proposed in our previous work. To clarify the components in the system that need further optimization and to improve its performance, an exergy analysis of a transcritical CO2 air-source heat pump system with the novel honeycomb gas cooler is studied in this paper. Based on the second law of thermodynamics, the exergy model of each component in the heat pump system is established, and the irreversible loss of each component is analyzed. In addition, the degree of energy loss of the honeycomb gas cooler is clarified, and the possibility and direction of system optimization are pointed out. The results show that the exergy efficiency of the system is 35.33% under nominal operating conditions, and there is a lot of room for improvement in its energy utilization. The three components with the largest exergy destruction percentage are the compressor, throttle valve, and evaporator in the order of 36.13%, 22.90%, and 19.51%, respectively. These components with high exergy destruction percentages are the main reasons for the large irreversible losses of the system.
Open AccessExergy Analysis of Transcritical CO2 Air-Source Heat Pump with Honeycomb Gas Cooler
In order to build an efficient and energy-saving CO2 heat pump system and to improve the heat transfer efficiency of the gas cooler, a novel honeycomb gas cooler with a compact structure, high heat transfer efficiency, and high pressure-bearing capacity was proposed in our previous work. To clarify the components in the system that need further optimization and to improve its performance, an exergy analysis of a transcritical CO2 air-source heat pump system with the novel honeycomb gas cooler is studied in this paper. Based on the second law of thermodynamics, the exergy model of each component in the heat pump system is established, and the irreversible loss of each component is analyzed. In addition, the degree of energy loss of the honeycomb gas cooler is clarified, and the possibility and direction of system optimization are pointed out. The results show that the exergy efficiency of the system is 35.33% under nominal operating conditions, and there is a lot of room for improvement in its energy utilization. The three components with the largest exergy destruction percentage are the compressor, throttle valve, and evaporator in the order of 36.13%, 22.90%, and 19.51%, respectively. These components with high exergy destruction percentages are the main reasons for the large irreversible losses of the system.
- Open Access
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 02054
Simulation study of heat transfer characteristics of a biomimetic honeycomb CO2 gas cooler
CO2 air source heat pumps are widely used because of their advantages of energy saving, high efficiency and clean. Gas cooler is one of the key components of CO2 heat pump system, while its heat transfer effect will affect the energy efficiency of the whole system. In order to improve the heat transfer efficiency, a biomimetic honeycomb gas cooler is proposed in this paper, the steady-state simulation model of the biomimetic honeycomb gas cooler is established by using MATLAB software, and the reliability of the model is verified by literature data. In addition, the heat transfer performance of the biomimetic honeycomb gas cooler is compared with that of the tube-in-tube gas cooler. The results showed that, under the same working condition, compared with the tube-in-tube gas cooler, the outlet temperature of the biomimetic honeycomb gas cooler with 1st, 2nd and 3rd level increased by 9.7°C, 25.4°C and 27.3°C, and heat transfer can be increased by 55.5%, 205.4% and 220.6% respectively. This research is helpful to provide the reference for the design and optimization of this type of gas cooler, and is conducive to the popularization of CO2 air source heat pump.
- 31 August 2022
- Published by EDP Sciences
- Vol. 356, 02054
Open AccessSimulation study of heat transfer characteristics of a biomimetic honeycomb CO2 gas cooler
CO2 air source heat pumps are widely used because of their advantages of energy saving, high efficiency and clean. Gas cooler is one of the key components of CO2 heat pump system, while its heat transfer effect will affect the energy efficiency of the whole system. In order to improve the heat transfer efficiency, a biomimetic honeycomb gas cooler is proposed in this paper, the steady-state simulation model of the biomimetic honeycomb gas cooler is established by using MATLAB software, and the reliability of the model is verified by literature data. In addition, the heat transfer performance of the biomimetic honeycomb gas cooler is compared with that of the tube-in-tube gas cooler. The results showed that, under the same working condition, compared with the tube-in-tube gas cooler, the outlet temperature of the biomimetic honeycomb gas cooler with 1st, 2nd and 3rd level increased by 9.7°C, 25.4°C and 27.3°C, and heat transfer can be increased by 55.5%, 205.4% and 220.6% respectively. This research is helpful to provide the reference for the design and optimization of this type of gas cooler, and is conducive to the popularization of CO2 air source heat pump.
- Open Access
- 10 December 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (24) , 13683
Performance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
CO2 air source heat pump (ASHP), as a kind of clean and efficient heating equipment, is a promising solution for domestic hot water and clean heating. However, the promotion of CO2 ASHP encounters a great resistance when it is used for space heating; namely, the return water temperature is too high that cased higher throttle loss, which decreases the COP of the CO2 ASHP unit. To solve this problem, a heating system of CO2 ASHP coupled with thermal energy storage (TES) is developed in this work. The simulation model of the studied system is established using TRNSYS software, and the model is verified by experimental data. Additionally, the performance of the studied system is optimized, and its economy is analyzed by life cycle cost (LCC). The results showed that, compared with the system before optimization, the cost of the optimized system increased, the annual operating cost of the system was reduced, and the COP of the system (COPsys) increased by 7.4%. This research is helpful in improving the application of the CO2 ASHP unit in cold server and cold areas.
- 10 December 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (24) , 13683
Open AccessPerformance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
CO2 air source heat pump (ASHP), as a kind of clean and efficient heating equipment, is a promising solution for domestic hot water and clean heating. However, the promotion of CO2 ASHP encounters a great resistance when it is used for space heating; namely, the return water temperature is too high that cased higher throttle loss, which decreases the COP of the CO2 ASHP unit. To solve this problem, a heating system of CO2 ASHP coupled with thermal energy storage (TES) is developed in this work. The simulation model of the studied system is established using TRNSYS software, and the model is verified by experimental data. Additionally, the performance of the studied system is optimized, and its economy is analyzed by life cycle cost (LCC). The results showed that, compared with the system before optimization, the cost of the optimized system increased, the annual operating cost of the system was reduced, and the COP of the system (COPsys) increased by 7.4%. This research is helpful in improving the application of the CO2 ASHP unit in cold server and cold areas.
- Open Access
Performance Analysis of a Combined Solar-Assisted Heat Pump Heating System in Xi’an, China
This study proposed a combined solar-assisted heat pump (SAHP) system that could operate in the serial mode or parallel mode. For this proposed system, a stable year-round operation could be achieved without the assistance of electric heating or low-temperature heat pump. By analyzing the heat balance equations, a correlation of the combined SAHP system for the two modes switched was obtained, which provided a theoretical basis for the optimal operation of this system. In addition, the performance of the proposed system applied in a university bathroom in Xi’an district was investigated using TRNSYS. The results illustrated that compared to the serial and parallel systems, the proposed system exhibited a good performance on energy efficiency. The annual average coefficient of performance (COP) of the proposed system was 5.7, obviously higher than those of the serial system and the parallel system, which were 3.3 and 4.3, respectively. Therefore, the results in this study could provide the theoretical guidance and reference for practical engineering design.
Open AccessPerformance Analysis of a Combined Solar-Assisted Heat Pump Heating System in Xi’an, China
This study proposed a combined solar-assisted heat pump (SAHP) system that could operate in the serial mode or parallel mode. For this proposed system, a stable year-round operation could be achieved without the assistance of electric heating or low-temperature heat pump. By analyzing the heat balance equations, a correlation of the combined SAHP system for the two modes switched was obtained, which provided a theoretical basis for the optimal operation of this system. In addition, the performance of the proposed system applied in a university bathroom in Xi’an district was investigated using TRNSYS. The results illustrated that compared to the serial and parallel systems, the proposed system exhibited a good performance on energy efficiency. The annual average coefficient of performance (COP) of the proposed system was 5.7, obviously higher than those of the serial system and the parallel system, which were 3.3 and 4.3, respectively. Therefore, the results in this study could provide the theoretical guidance and reference for practical engineering design.