Kaiwen Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kaiwen Xu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Zhihua Wang
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Feng Li
PowerChina Construction Industry Investment Corporation Limited, Beijing 100000, China
1 shared publication - Fenghao Wang
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an, China
1 shared publication - Ge Yao
PowerChina Northwest Engineering Corporation Limited, Xi’an 710065, China
1 shared publication - Guichen Li
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Huan Gao
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710116, China
1 shared publication
Latest Publications
- Open Access
Research on Parameter Optimization and Control Strategy of Air Source Heat Pump Coupled with Thermal Energy Storage System
The air source heat pump coupled with energy storage system is a key technology for flexibly utilizing clean energy. The capacity configuration parameters and control strategies of this coupled system are two important aspects that significantly affect its performance. In order to explore the methods of setting configuration parameters and provide reasonable operation strategies, a simulation model of the coupled system under a time-of-use electricity pricing strategy is established and verified with measured data. Through multi-objective optimization of the system, configuration schemes considering economy, energy saving, and flexibility are given. Subsequently, based on the load prediction model, an optimal control strategy is proposed with the objective function of minimizing the operating cost. The optimization amplitude of the schemes considering the three indicators reached 11.09%, 13.37%, and 29.03%, respectively. Under the proposed control strategies, the typical daily electricity consumption decreased by 14.65% to 24.06%, and the operating electricity cost is saved by approximately 17.32%. By reasonably designing the parameters of the coupled system, its economic, energy-saving performance, and flexibility can be improved by more than 11% compared to a system designed using traditional methods. By adopting the control strategy based on hourly load prediction, the operating cost can be reduced significantly.
Open AccessResearch on Parameter Optimization and Control Strategy of Air Source Heat Pump Coupled with Thermal Energy Storage System
The air source heat pump coupled with energy storage system is a key technology for flexibly utilizing clean energy. The capacity configuration parameters and control strategies of this coupled system are two important aspects that significantly affect its performance. In order to explore the methods of setting configuration parameters and provide reasonable operation strategies, a simulation model of the coupled system under a time-of-use electricity pricing strategy is established and verified with measured data. Through multi-objective optimization of the system, configuration schemes considering economy, energy saving, and flexibility are given. Subsequently, based on the load prediction model, an optimal control strategy is proposed with the objective function of minimizing the operating cost. The optimization amplitude of the schemes considering the three indicators reached 11.09%, 13.37%, and 29.03%, respectively. Under the proposed control strategies, the typical daily electricity consumption decreased by 14.65% to 24.06%, and the operating electricity cost is saved by approximately 17.32%. By reasonably designing the parameters of the coupled system, its economic, energy-saving performance, and flexibility can be improved by more than 11% compared to a system designed using traditional methods. By adopting the control strategy based on hourly load prediction, the operating cost can be reduced significantly.
- Top Cited PapersOpen Access
A Review of Building Carbon Emission Accounting and Prediction Models
As an industry that consumes a quarter of social energy and emits a third of greenhouse gases, the construction industry has an important responsibility to achieve carbon peaking and carbon neutrality. Based on Web of Science, Science-Direct, and CNKI, the accounting and prediction models of carbon emissions from buildings are reviewed. The carbon emission factor method, mass balance method, and actual measurement method are analyzed. The top-down and bottom-up carbon emission accounting models and their subdivision models are introduced and analyzed. Individual building carbon emission assessments generally adopt a bottom-up physical model, while urban carbon emission assessments generally adopt a top-down economic input-output model. Most of the current studies on building carbon emission prediction models follow the path of “exploring influencing factors then putting forward prediction models based on influencing factors”. The studies on driving factors of carbon emission mainly use the Stochastic Impacts by Regression on Population, Affluence, and Technology (STIRPAT) model, the Logarithmic Mean Divisia Index (LMDI) model, the grey correlation degree model, and other models. The prediction model is realized by the regression model, the system dynamics model, and other mathematical models, as well as the Artificial Neural Network (ANN) model, the Support Vector Machine (SVM) model, and other machine learning models. At present, the research on carbon emission models of individual buildings mainly focuses on the prediction of operational energy consumption, and the research models for the other stages should become a focus in future research.
Top Cited PapersOpen AccessA Review of Building Carbon Emission Accounting and Prediction Models
As an industry that consumes a quarter of social energy and emits a third of greenhouse gases, the construction industry has an important responsibility to achieve carbon peaking and carbon neutrality. Based on Web of Science, Science-Direct, and CNKI, the accounting and prediction models of carbon emissions from buildings are reviewed. The carbon emission factor method, mass balance method, and actual measurement method are analyzed. The top-down and bottom-up carbon emission accounting models and their subdivision models are introduced and analyzed. Individual building carbon emission assessments generally adopt a bottom-up physical model, while urban carbon emission assessments generally adopt a top-down economic input-output model. Most of the current studies on building carbon emission prediction models follow the path of “exploring influencing factors then putting forward prediction models based on influencing factors”. The studies on driving factors of carbon emission mainly use the Stochastic Impacts by Regression on Population, Affluence, and Technology (STIRPAT) model, the Logarithmic Mean Divisia Index (LMDI) model, the grey correlation degree model, and other models. The prediction model is realized by the regression model, the system dynamics model, and other mathematical models, as well as the Artificial Neural Network (ANN) model, the Support Vector Machine (SVM) model, and other machine learning models. At present, the research on carbon emission models of individual buildings mainly focuses on the prediction of operational energy consumption, and the research models for the other stages should become a focus in future research.
- Open Access
- 10 December 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (24) , 13683
Performance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
CO2 air source heat pump (ASHP), as a kind of clean and efficient heating equipment, is a promising solution for domestic hot water and clean heating. However, the promotion of CO2 ASHP encounters a great resistance when it is used for space heating; namely, the return water temperature is too high that cased higher throttle loss, which decreases the COP of the CO2 ASHP unit. To solve this problem, a heating system of CO2 ASHP coupled with thermal energy storage (TES) is developed in this work. The simulation model of the studied system is established using TRNSYS software, and the model is verified by experimental data. Additionally, the performance of the studied system is optimized, and its economy is analyzed by life cycle cost (LCC). The results showed that, compared with the system before optimization, the cost of the optimized system increased, the annual operating cost of the system was reduced, and the COP of the system (COPsys) increased by 7.4%. This research is helpful in improving the application of the CO2 ASHP unit in cold server and cold areas.
- 10 December 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (24) , 13683
Open AccessPerformance Optimization and Economic Evaluation of CO2 Heat Pump Heating System Coupled with Thermal Energy Storage
CO2 air source heat pump (ASHP), as a kind of clean and efficient heating equipment, is a promising solution for domestic hot water and clean heating. However, the promotion of CO2 ASHP encounters a great resistance when it is used for space heating; namely, the return water temperature is too high that cased higher throttle loss, which decreases the COP of the CO2 ASHP unit. To solve this problem, a heating system of CO2 ASHP coupled with thermal energy storage (TES) is developed in this work. The simulation model of the studied system is established using TRNSYS software, and the model is verified by experimental data. Additionally, the performance of the studied system is optimized, and its economy is analyzed by life cycle cost (LCC). The results showed that, compared with the system before optimization, the cost of the optimized system increased, the annual operating cost of the system was reduced, and the COP of the system (COPsys) increased by 7.4%. This research is helpful in improving the application of the CO2 ASHP unit in cold server and cold areas.