Bharath Ramakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bharath Ramakrishnan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bahgat Sammakia
Department of Mechanical Engineering, Binghamton University-SUNY, Binghamton, NY 13902
3 shared publications - Sami Alkharabsheh
Department of Mechanical Engineering, Binghamton University, Binghamton, NY 13902
2 shared publications - Yaser Hadad
Department of Mechanical Engineering, State University of New York at Binghamton , Binghamton, NY 13902
2 shared publications - Cong Hiep Hoang
Department of Mechanical Engineering, State University of New York at Binghamton, Binghamton, NY, USA
1 shared publication - Kanad Ghose
Department of Computer Science, Binghamton University, Binghamton, NY 13902
1 shared publication - Mohammad I. Tradat
Department of Mechanical Engineering, ES2 Center, Binghamton University-SUNY , Binghamton, NY 13902
1 shared publication
Latest Publications
- Open Access
- 16 July 2021
- Published by ASME International
Liquid Cooling Utilizing a Hybrid Micro-Channel/multi-Jet Heat Sink: A Component Level Study of Commercial Product
The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high-power demands can be met, while the reliability of the electronic devices is greatly improved. In this paper, thermo-hydraulic performance of a commercial hybrid micro-channel/slot-jet heat sink with
- 16 July 2021
- Published by ASME International
Open AccessLiquid Cooling Utilizing a Hybrid Micro-Channel/multi-Jet Heat Sink: A Component Level Study of Commercial Product
The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high-power demands can be met, while the reliability of the electronic devices is greatly improved. In this paper, thermo-hydraulic performance of a commercial hybrid micro-channel/slot-jet heat sink with
- 12 July 2019
- Published by ASME International in Journal of Electronic Packaging
- Vol. 141 (4)
Thermal Analysis of Cold Plate for Direct Liquid Cooling of High Performance Servers
Data center energy usage keeps growing every year and will continue to increase with rising demand for ecommerce, scientific research, social networking, and use of streaming video services. The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high power demands can be met, while the reliability of the electronic devices is greatly improved. Cold plates which are mounted directly on to the chips facilitate a lower thermal resistance path originating from the chip to the incoming coolant. An attempt was made in the current study to characterize a commercially available cold plate which uses warm water in carrying the heat away from the chip. A mock package mimicking a processor chip with an effective heat transfer area of 6.45 cm2 was developed for this study using a copper block heater arrangement. The thermo-hydraulic performance of the cold plates was investigated by conducting experiments at varying chip power, coolant flow rates, and coolant temperature. The pressure drop (ΔP) and the temperature rise (ΔT) across the cold plates were measured, and the results were presented as flow resistance and thermal resistance curves. A maximum heat flux of 31 W/cm2 was dissipated at a flow rate of 13 cm3/s. A resistance network model was used to calculate an effective heat transfer coefficient by revealing different elements contributing to the total resistance. The study extended to different coolant temperatures ranging from 25 °C to 45 °C addresses the effect of coolant viscosity on the overall performance of the cold plate, and the results were presented as coefficient of performance (COP) curves. A numerical model developed using 6SigmaET was validated against the experimental findings for the flow and thermal performance with minimal percentage difference.
- 12 July 2019
- Published by ASME International in Journal of Electronic Packaging
- Vol. 141 (4)
Thermal Analysis of Cold Plate for Direct Liquid Cooling of High Performance Servers
Data center energy usage keeps growing every year and will continue to increase with rising demand for ecommerce, scientific research, social networking, and use of streaming video services. The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high power demands can be met, while the reliability of the electronic devices is greatly improved. Cold plates which are mounted directly on to the chips facilitate a lower thermal resistance path originating from the chip to the incoming coolant. An attempt was made in the current study to characterize a commercially available cold plate which uses warm water in carrying the heat away from the chip. A mock package mimicking a processor chip with an effective heat transfer area of 6.45 cm2 was developed for this study using a copper block heater arrangement. The thermo-hydraulic performance of the cold plates was investigated by conducting experiments at varying chip power, coolant flow rates, and coolant temperature. The pressure drop (ΔP) and the temperature rise (ΔT) across the cold plates were measured, and the results were presented as flow resistance and thermal resistance curves. A maximum heat flux of 31 W/cm2 was dissipated at a flow rate of 13 cm3/s. A resistance network model was used to calculate an effective heat transfer coefficient by revealing different elements contributing to the total resistance. The study extended to different coolant temperatures ranging from 25 °C to 45 °C addresses the effect of coolant viscosity on the overall performance of the cold plate, and the results were presented as coefficient of performance (COP) curves. A numerical model developed using 6SigmaET was validated against the experimental findings for the flow and thermal performance with minimal percentage difference.
- 9 May 2018
- Published by ASME International in Journal of Electronic Packaging
- Vol. 140 (2)
Failure Analysis of Direct Liquid Cooling System in Data Centers
In this paper, the impact of direct liquid cooling (DLC) system failure on the information technology (IT) equipment is studied experimentally. The main factors that are anticipated to affect the IT equipment response during failure are the central processing unit (CPU) utilization, coolant set point temperature (SPT), and the server type. These factors are varied experimentally and the IT equipment response is studied in terms of chip temperature and power, CPU utilization, and total server power. It was found that failure of this cooling system is hazardous and can lead to data center shutdown in less than a minute. Additionally, the CPU frequency throttling mechanism was found to be vital to understand the change in chip temperature, power, and utilization. Other mechanisms associated with high temperatures were also observed such as the leakage power and the fans' speed change. Finally, possible remedies are proposed to reduce the probability and the consequences of the cooling system failure.
- 9 May 2018
- Published by ASME International in Journal of Electronic Packaging
- Vol. 140 (2)
Failure Analysis of Direct Liquid Cooling System in Data Centers
In this paper, the impact of direct liquid cooling (DLC) system failure on the information technology (IT) equipment is studied experimentally. The main factors that are anticipated to affect the IT equipment response during failure are the central processing unit (CPU) utilization, coolant set point temperature (SPT), and the server type. These factors are varied experimentally and the IT equipment response is studied in terms of chip temperature and power, CPU utilization, and total server power. It was found that failure of this cooling system is hazardous and can lead to data center shutdown in less than a minute. Additionally, the CPU frequency throttling mechanism was found to be vital to understand the change in chip temperature, power, and utilization. Other mechanisms associated with high temperatures were also observed such as the leakage power and the fans' speed change. Finally, possible remedies are proposed to reduce the probability and the consequences of the cooling system failure.