Tobias Steinwedel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tobias Steinwedel has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Anton Enders
Institute of Technical Chemistry Leibniz University Hannover 30167 Hannover Germany
1 shared publication - Antonina Lavrentieva
Institute of Technical Chemistry, Leibniz University Hannover, Germany
1 shared publication - Carlotta Kortmann
Institute of Technical Chemistry, Leibniz University, 30167 Hanover, Germany
1 shared publication - Dörte Solle
Institut für Technische Chemie Leibniz Universität Hannover Hannover Germany
1 shared publication - Ina Gerhild Siller
Institute of Technical Chemistry, Leibniz University Hannover, Callinstrasse 5, 30167 Hannover, Germany
1 shared publication - Jana Schellenberg
Institute of Technical Chemistry, Leibniz University, 30167 Hanover, Germany
1 shared publication
Latest Publications
- Open Access
- 1 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 202
Application of a Novel Disposable Flow Cell for Spectroscopic Bioprocess Monitoring
The evaluation of the analytical capabilities of a novel disposable flow cell for spectroscopic bioprocess monitoring is presented. The flow cell is presterilized and can be connected to any kind of bioreactor by weldable tube connections. It is clamped into a reusable holder, which is equipped with SMA-terminated optical fibers or an integrated light source and detection unit. This modular construction enables spectroscopic techniques like UV-Vis spectroscopy or turbidity measurements by scattered light for modern disposable bioreactors. A NIR scattering module was used for biomass monitoring in different cultivations. A high-cell-density fed-batch cultivation with Komagataella phaffii and a continuous perfusion cultivation with a CHO DG44 cell line were conducted. A high correlation between the sensor signal and biomass or viable cell count was observed. Furthermore, the sensor shows high sensitivity during low turbidity states, as well as a high dynamic range to monitor high turbidity values without saturation effects. In addition to upstream processing, the sensor system was used to monitor the purification process of a monoclonal antibody. The absorption module enables simple and cost-efficient monitoring of downstream processing and quality control measurements. Recorded absorption spectra can be used for antibody aggregate detection, due to an increase in overall optical density.
- 1 October 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (10) , 202
Open AccessApplication of a Novel Disposable Flow Cell for Spectroscopic Bioprocess Monitoring
The evaluation of the analytical capabilities of a novel disposable flow cell for spectroscopic bioprocess monitoring is presented. The flow cell is presterilized and can be connected to any kind of bioreactor by weldable tube connections. It is clamped into a reusable holder, which is equipped with SMA-terminated optical fibers or an integrated light source and detection unit. This modular construction enables spectroscopic techniques like UV-Vis spectroscopy or turbidity measurements by scattered light for modern disposable bioreactors. A NIR scattering module was used for biomass monitoring in different cultivations. A high-cell-density fed-batch cultivation with Komagataella phaffii and a continuous perfusion cultivation with a CHO DG44 cell line were conducted. A high correlation between the sensor signal and biomass or viable cell count was observed. Furthermore, the sensor shows high sensitivity during low turbidity states, as well as a high dynamic range to monitor high turbidity values without saturation effects. In addition to upstream processing, the sensor system was used to monitor the purification process of a monoclonal antibody. The absorption module enables simple and cost-efficient monitoring of downstream processing and quality control measurements. Recorded absorption spectra can be used for antibody aggregate detection, due to an increase in overall optical density.
- Open Access
Real-Time Live-Cell Imaging Technology Enables High-Throughput Screening to Verify in Vitro Biocompatibility of 3D Printed Materials
With growing advances in three-dimensional (3D) printing technology, the availability and diversity of printing materials has rapidly increased over the last years. 3D printing has quickly become a useful tool for biomedical and various laboratory applications, offering a tremendous potential for efficiently fabricating complex devices in a short period of time. However, there still remains a lack of information regarding the impact of printing materials and post-processing techniques on cell behavior. This study introduces real-time live-cell imaging technology as a fast, user-friendly, and high-throughput screening strategy to verify the in vitro biocompatibility of 3D printed materials. Polyacrylate-based photopolymer material was printed using high-resolution 3D printing techniques, post-processed using three different procedures, and then analyzed with respect to its effects on cell viability, apoptosis, and necrosis of adipogenic mesenchymal stem cells (MSCs). When using ethanol for the post-processing procedure and disinfection, no significant effects on MSCs could be detected. For the analyses a novel image-based live-cell analysis system was compared against a biochemical-based standard plate reader assay and traditional flow cytometry. This comparison illustrates the superiority of using image-based detection of in vitro biocompatibility with respect to analysis time, usability, and scientific outcome.
Open AccessReal-Time Live-Cell Imaging Technology Enables High-Throughput Screening to Verify in Vitro Biocompatibility of 3D Printed Materials
With growing advances in three-dimensional (3D) printing technology, the availability and diversity of printing materials has rapidly increased over the last years. 3D printing has quickly become a useful tool for biomedical and various laboratory applications, offering a tremendous potential for efficiently fabricating complex devices in a short period of time. However, there still remains a lack of information regarding the impact of printing materials and post-processing techniques on cell behavior. This study introduces real-time live-cell imaging technology as a fast, user-friendly, and high-throughput screening strategy to verify the in vitro biocompatibility of 3D printed materials. Polyacrylate-based photopolymer material was printed using high-resolution 3D printing techniques, post-processed using three different procedures, and then analyzed with respect to its effects on cell viability, apoptosis, and necrosis of adipogenic mesenchymal stem cells (MSCs). When using ethanol for the post-processing procedure and disinfection, no significant effects on MSCs could be detected. For the analyses a novel image-based live-cell analysis system was compared against a biochemical-based standard plate reader assay and traditional flow cytometry. This comparison illustrates the superiority of using image-based detection of in vitro biocompatibility with respect to analysis time, usability, and scientific outcome.