Paul Maurice
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Paul Maurice has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Marie Jouannic
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
9 shared publications - Ferdinand Dhombres
Sorbonne Université, Université Paris 13, Sorbonne Paris Cité, INSERM, UMR_S 1142, LIMICS, Paris, France
6 shared publications - Lucie Guilbaud
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
6 shared publications - Eléonore Blondiaux
Pediatric Radiology Department, Hôpital Armand‐Trousseau APHP Sorbonne Université Paris France
3 shared publications - Loriane Franchinard
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
3 shared publications - Anaïs Dugas
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
2 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Wiley in Prenatal Diagnosis
Biological Specificities of Fetal Anemia Induced by Parvovirus B19 Infection
Objective: To describe the biological fetal parameters in cases of severe anemia induced by parvovirus B19 (B19V) infection. Method: A retrospective single center study was conducted including cases of fetal anemia due to B19V receiving in utero transfusion (IUT) from January 2011 to May 2024. Biological data from fetal blood at first IUT were collected. Results: 65 cases were included. Median Hemoglobin was 3 g/dL [IQR 2.1–3.8] and median reticulocyte count was low (39.9 G/L [IQR 17.0–71.1]). Lymphopenia and elevated erythroblasts were noted in 37.5% and 59.1% of cases, respectively. High Aspartate aminotransferase (AST) levels and hypoproteinemia were observed in 97.6% and 71.4% of cases, respectively. The median lactate dehydrogenase (LDH) level was high (1556.0 U/L [IQR 611.0–2405.0]). Hydropic fetuses significantly exhibited lower hemoglobin levels (median 2.5 g/dL vs. 3.8 g/dL; p = 0.0315), lower platelet counts (median 30.5 G/L vs. 71.5 G/L; p = 0.0014), higher AST (median 97.0 vs. 20.0 U/L; p = 0.0002) and LDH levels (median 2068 vs. 329.5 U/L; p = 0.0002) compared to non‐hydropic cases. Conclusion: Severe fetal anemia due to B19V infection is associated with specific hematological and biochemical anomalies, some of which are more pronounced in case of hydrops.
- 10 October 2026
- Published by Wiley in Prenatal Diagnosis
Open AccessBiological Specificities of Fetal Anemia Induced by Parvovirus B19 Infection
Objective: To describe the biological fetal parameters in cases of severe anemia induced by parvovirus B19 (B19V) infection. Method: A retrospective single center study was conducted including cases of fetal anemia due to B19V receiving in utero transfusion (IUT) from January 2011 to May 2024. Biological data from fetal blood at first IUT were collected. Results: 65 cases were included. Median Hemoglobin was 3 g/dL [IQR 2.1–3.8] and median reticulocyte count was low (39.9 G/L [IQR 17.0–71.1]). Lymphopenia and elevated erythroblasts were noted in 37.5% and 59.1% of cases, respectively. High Aspartate aminotransferase (AST) levels and hypoproteinemia were observed in 97.6% and 71.4% of cases, respectively. The median lactate dehydrogenase (LDH) level was high (1556.0 U/L [IQR 611.0–2405.0]). Hydropic fetuses significantly exhibited lower hemoglobin levels (median 2.5 g/dL vs. 3.8 g/dL; p = 0.0315), lower platelet counts (median 30.5 G/L vs. 71.5 G/L; p = 0.0014), higher AST (median 97.0 vs. 20.0 U/L; p = 0.0002) and LDH levels (median 2068 vs. 329.5 U/L; p = 0.0002) compared to non‐hydropic cases. Conclusion: Severe fetal anemia due to B19V infection is associated with specific hematological and biochemical anomalies, some of which are more pronounced in case of hydrops.
- Open Access
- 20 September 2026
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 68 (4) , 518-526
Prenatal findings and postnatal outcomes in cases of closed spinal dysraphism: 10‐year two‐center cohort study
Objective: To characterize prenatal ultrasound findings in fetuses with prenatally diagnosed closed spinal dysraphism (CSD) and report their postnatal management and functional outcomes at 18 and 36 months. Methods: This retrospective cohort study included all fetuses with a prenatal diagnosis of CSD assessed between January 2014 and December 2024 at two tertiary centers (Fetal Medicine Department of Trousseau Hospital, Paris, France, and Department of Obstetrics and Gynecology, University Hospitals Leuven, Leuven, Belgium). Lesions were reassessed and classified according to the updated Orphanet classification system for dysraphisms. Cases of open dysraphism, intermediate forms, Currarino syndrome, caudal regression syndrome and postnatally diagnosed cases were excluded. Prenatal imaging findings, pregnancy outcomes, postnatal diagnostic concordance, neurosurgical management and functional outcomes were analyzed. Results: Seventy fetuses with a prenatal diagnosis of CSD were included. Saccular forms of CSD accounted for 85.7% ( n = 60) of cases, including 33 (47.1%) cases of limited dorsal myeloschisis, 18 (25.7%) cases of posterior meningocele and nine (12.9%) cases of conus spinal cord lipoma. Most (85.7%) lesions were located at the lumbar or sacral level. Associated structural cerebral anomalies were identified prenatally in 17.1% ( n = 12) of cases. There were 59 (84.3%) live births and 11 (15.7%) terminations of pregnancy, including eight cases with major cerebral anomalies. Among liveborn infants with available data on postnatal surgical interventions ( n/N = 44/59), postnatal surgery was performed in 90.9% of cases. The prenatal diagnosis was adjusted postnatally in 4/39 (10.3%) cases with available postnatal outcome data. At 36 months, independent ambulation was achieved in 94.4% (17/18) of children with follow‐up data available at this time point. In contrast, urinary dysfunction was present in 38.9% of cases at 36 months, while gastrointestinal disorders were less frequent (22.2%). Conclusion: Using the Orphanet classification, prenatal ultrasound examination allows reliable anatomical characterization of CSD in 89.7% of cases. Motor outcomes are generally favorable, whereas urological morbidity is observed in nearly half of cases at 18 months. These are important elements to consider in prenatal counseling. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- 20 September 2026
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 68 (4) , 518-526
Open AccessPrenatal findings and postnatal outcomes in cases of closed spinal dysraphism: 10‐year two‐center cohort study
Objective: To characterize prenatal ultrasound findings in fetuses with prenatally diagnosed closed spinal dysraphism (CSD) and report their postnatal management and functional outcomes at 18 and 36 months. Methods: This retrospective cohort study included all fetuses with a prenatal diagnosis of CSD assessed between January 2014 and December 2024 at two tertiary centers (Fetal Medicine Department of Trousseau Hospital, Paris, France, and Department of Obstetrics and Gynecology, University Hospitals Leuven, Leuven, Belgium). Lesions were reassessed and classified according to the updated Orphanet classification system for dysraphisms. Cases of open dysraphism, intermediate forms, Currarino syndrome, caudal regression syndrome and postnatally diagnosed cases were excluded. Prenatal imaging findings, pregnancy outcomes, postnatal diagnostic concordance, neurosurgical management and functional outcomes were analyzed. Results: Seventy fetuses with a prenatal diagnosis of CSD were included. Saccular forms of CSD accounted for 85.7% ( n = 60) of cases, including 33 (47.1%) cases of limited dorsal myeloschisis, 18 (25.7%) cases of posterior meningocele and nine (12.9%) cases of conus spinal cord lipoma. Most (85.7%) lesions were located at the lumbar or sacral level. Associated structural cerebral anomalies were identified prenatally in 17.1% ( n = 12) of cases. There were 59 (84.3%) live births and 11 (15.7%) terminations of pregnancy, including eight cases with major cerebral anomalies. Among liveborn infants with available data on postnatal surgical interventions ( n/N = 44/59), postnatal surgery was performed in 90.9% of cases. The prenatal diagnosis was adjusted postnatally in 4/39 (10.3%) cases with available postnatal outcome data. At 36 months, independent ambulation was achieved in 94.4% (17/18) of children with follow‐up data available at this time point. In contrast, urinary dysfunction was present in 38.9% of cases at 36 months, while gastrointestinal disorders were less frequent (22.2%). Conclusion: Using the Orphanet classification, prenatal ultrasound examination allows reliable anatomical characterization of CSD in 89.7% of cases. Motor outcomes are generally favorable, whereas urological morbidity is observed in nearly half of cases at 18 months. These are important elements to consider in prenatal counseling. © 2026 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 13 June 2023
- Published by CAIRN.INFO in Allemagne d'aujourd'hui
- Vol. N° 244 (2) , 3-9
La relation franco-allemande malgré tout
- 13 June 2023
- Published by CAIRN.INFO in Allemagne d'aujourd'hui
- Vol. N° 244 (2) , 3-9
Open AccessLa relation franco-allemande malgré tout
- Top Cited PapersOpen Access
- 20 April 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (4) , e35465
Contributions of Artificial Intelligence Reported in Obstetrics and Gynecology Journals: Systematic Review
Background: The applications of artificial intelligence (AI) processes have grown significantly in all medical disciplines during the last decades. Two main types of AI have been applied in medicine: symbolic AI (eg, knowledge base and ontologies) and nonsymbolic AI (eg, machine learning and artificial neural networks). Consequently, AI has also been applied across most obstetrics and gynecology (OB/GYN) domains, including general obstetrics, gynecology surgery, fetal ultrasound, and assisted reproductive medicine, among others. Objective: The aim of this study was to provide a systematic review to establish the actual contributions of AI reported in OB/GYN discipline journals. Methods: The PubMed database was searched for citations indexed with “artificial intelligence” and at least one of the following medical subject heading (MeSH) terms between January 1, 2000, and April 30, 2020: “obstetrics”; “gynecology”; “reproductive techniques, assisted”; or “pregnancy.” All publications in OB/GYN core disciplines journals were considered. The selection of journals was based on disciplines defined in Web of Science. The publications were excluded if no AI process was used in the study. Review, editorial, and commentary articles were also excluded. The study analysis comprised (1) classification of publications into OB/GYN domains, (2) description of AI methods, (3) description of AI algorithms, (4) description of data sets, (5) description of AI contributions, and (6) description of the validation of the AI process. Results: The PubMed search retrieved 579 citations and 66 publications met the selection criteria. All OB/GYN subdomains were covered: obstetrics (41%, 27/66), gynecology (3%, 2/66), assisted reproductive medicine (33%, 22/66), early pregnancy (2%, 1/66), and fetal medicine (21%, 14/66). Both machine learning methods (39/66) and knowledge base methods (25/66) were represented. Machine learning used imaging, numerical, and clinical data sets. Knowledge base methods used mostly omics data sets. The actual contributions of AI were method/algorithm development (53%, 35/66), hypothesis generation (42%, 28/66), or software development (3%, 2/66). Validation was performed on one data set (86%, 57/66) and no external validation was reported. We observed a general rising trend in publications related to AI in OB/GYN over the last two decades. Most of these publications (82%, 54/66) remain out of the scope of the usual OB/GYN journals. Conclusions: In OB/GYN discipline journals, mostly preliminary work (eg, proof-of-concept algorithm or method) in AI applied to this discipline is reported and clinical validation remains an unmet prerequisite. Improvement driven by new AI research guidelines is expected. However, these guidelines are covering only a part of AI approaches (nonsymbolic) reported in this review; hence, updates need to be considered.
- 20 April 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (4) , e35465
Top Cited PapersOpen AccessContributions of Artificial Intelligence Reported in Obstetrics and Gynecology Journals: Systematic Review
Background: The applications of artificial intelligence (AI) processes have grown significantly in all medical disciplines during the last decades. Two main types of AI have been applied in medicine: symbolic AI (eg, knowledge base and ontologies) and nonsymbolic AI (eg, machine learning and artificial neural networks). Consequently, AI has also been applied across most obstetrics and gynecology (OB/GYN) domains, including general obstetrics, gynecology surgery, fetal ultrasound, and assisted reproductive medicine, among others. Objective: The aim of this study was to provide a systematic review to establish the actual contributions of AI reported in OB/GYN discipline journals. Methods: The PubMed database was searched for citations indexed with “artificial intelligence” and at least one of the following medical subject heading (MeSH) terms between January 1, 2000, and April 30, 2020: “obstetrics”; “gynecology”; “reproductive techniques, assisted”; or “pregnancy.” All publications in OB/GYN core disciplines journals were considered. The selection of journals was based on disciplines defined in Web of Science. The publications were excluded if no AI process was used in the study. Review, editorial, and commentary articles were also excluded. The study analysis comprised (1) classification of publications into OB/GYN domains, (2) description of AI methods, (3) description of AI algorithms, (4) description of data sets, (5) description of AI contributions, and (6) description of the validation of the AI process. Results: The PubMed search retrieved 579 citations and 66 publications met the selection criteria. All OB/GYN subdomains were covered: obstetrics (41%, 27/66), gynecology (3%, 2/66), assisted reproductive medicine (33%, 22/66), early pregnancy (2%, 1/66), and fetal medicine (21%, 14/66). Both machine learning methods (39/66) and knowledge base methods (25/66) were represented. Machine learning used imaging, numerical, and clinical data sets. Knowledge base methods used mostly omics data sets. The actual contributions of AI were method/algorithm development (53%, 35/66), hypothesis generation (42%, 28/66), or software development (3%, 2/66). Validation was performed on one data set (86%, 57/66) and no external validation was reported. We observed a general rising trend in publications related to AI in OB/GYN over the last two decades. Most of these publications (82%, 54/66) remain out of the scope of the usual OB/GYN journals. Conclusions: In OB/GYN discipline journals, mostly preliminary work (eg, proof-of-concept algorithm or method) in AI applied to this discipline is reported and clinical validation remains an unmet prerequisite. Improvement driven by new AI research guidelines is expected. However, these guidelines are covering only a part of AI approaches (nonsymbolic) reported in this review; hence, updates need to be considered.
- 1 February 2022
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 50 (2) , 189-193
Réflexions éthiques concernant la chirurgie fœtale de réparation des myéloméningocèles
- 1 February 2022
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 50 (2) , 189-193
Réflexions éthiques concernant la chirurgie fœtale de réparation des myéloméningocèles
- Open Access
- 5 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Contributions of Artificial Intelligence Reported in Obstetrics and Gynecology Journals: Systematic Review (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The applications of artificial intelligence (AI) processes have grown significantly in all medical disciplines during the last decades. Two main types of AI have been applied in medicine: symbolic AI (eg, knowledge base and ontologies) and nonsymbolic AI (eg, machine learning and artificial neural networks). Consequently, AI has also been applied across most obstetrics and gynecology (OB/GYN) domains, including general obstetrics, gynecology surgery, fetal ultrasound, and assisted reproductive medicine, among others. Objective: The aim of this study was to provide a systematic review to establish the actual contributions of AI reported in OB/GYN discipline journals. Methods: The PubMed database was searched for citations indexed with “artificial intelligence” and at least one of the following medical subject heading (MeSH) terms between January 1, 2000, and April 30, 2020: “obstetrics”; “gynecology”; “reproductive techniques, assisted”; or “pregnancy.” All publications in OB/GYN core disciplines journals were considered. The selection of journals was based on disciplines defined in Web of Science. The publications were excluded if no AI process was used in the study. Review, editorial, and commentary articles were also excluded. The study analysis comprised (1) classification of publications into OB/GYN domains, (2) description of AI methods, (3) description of AI algorithms, (4) description of data sets, (5) description of AI contributions, and (6) description of the validation of the AI process. Results: The PubMed search retrieved 579 citations and 66 publications met the selection criteria. All OB/GYN subdomains were covered: obstetrics (41%, 27/66), gynecology (3%, 2/66), assisted reproductive medicine (33%, 22/66), early pregnancy (2%, 1/66), and fetal medicine (21%, 14/66). Both machine learning methods (39/66) and knowledge base methods (25/66) were represented. Machine learning used imaging, numerical, and clinical data sets. Knowledge base methods used mostly omics data sets. The actual contributions of AI were method/algorithm development (53%, 35/66), hypothesis generation (42%, 28/66), or software development (3%, 2/66). Validation was performed on one data set (86%, 57/66) and no external validation was reported. We observed a general rising trend in publications related to AI in OB/GYN over the last two decades. Most of these publications (82%, 54/66) remain out of the scope of the usual OB/GYN journals. Conclusions: In OB/GYN discipline journals, mostly preliminary work (eg, proof-of-concept algorithm or method) in AI applied to this discipline is reported and clinical validation remains an unmet prerequisite. Improvement driven by new AI research guidelines is expected. However, these guidelines are covering only a part of AI approaches (nonsymbolic) reported in this review; hence, updates need to be considered.
- 5 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContributions of Artificial Intelligence Reported in Obstetrics and Gynecology Journals: Systematic Review (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The applications of artificial intelligence (AI) processes have grown significantly in all medical disciplines during the last decades. Two main types of AI have been applied in medicine: symbolic AI (eg, knowledge base and ontologies) and nonsymbolic AI (eg, machine learning and artificial neural networks). Consequently, AI has also been applied across most obstetrics and gynecology (OB/GYN) domains, including general obstetrics, gynecology surgery, fetal ultrasound, and assisted reproductive medicine, among others. Objective: The aim of this study was to provide a systematic review to establish the actual contributions of AI reported in OB/GYN discipline journals. Methods: The PubMed database was searched for citations indexed with “artificial intelligence” and at least one of the following medical subject heading (MeSH) terms between January 1, 2000, and April 30, 2020: “obstetrics”; “gynecology”; “reproductive techniques, assisted”; or “pregnancy.” All publications in OB/GYN core disciplines journals were considered. The selection of journals was based on disciplines defined in Web of Science. The publications were excluded if no AI process was used in the study. Review, editorial, and commentary articles were also excluded. The study analysis comprised (1) classification of publications into OB/GYN domains, (2) description of AI methods, (3) description of AI algorithms, (4) description of data sets, (5) description of AI contributions, and (6) description of the validation of the AI process. Results: The PubMed search retrieved 579 citations and 66 publications met the selection criteria. All OB/GYN subdomains were covered: obstetrics (41%, 27/66), gynecology (3%, 2/66), assisted reproductive medicine (33%, 22/66), early pregnancy (2%, 1/66), and fetal medicine (21%, 14/66). Both machine learning methods (39/66) and knowledge base methods (25/66) were represented. Machine learning used imaging, numerical, and clinical data sets. Knowledge base methods used mostly omics data sets. The actual contributions of AI were method/algorithm development (53%, 35/66), hypothesis generation (42%, 28/66), or software development (3%, 2/66). Validation was performed on one data set (86%, 57/66) and no external validation was reported. We observed a general rising trend in publications related to AI in OB/GYN over the last two decades. Most of these publications (82%, 54/66) remain out of the scope of the usual OB/GYN journals. Conclusions: In OB/GYN discipline journals, mostly preliminary work (eg, proof-of-concept algorithm or method) in AI applied to this discipline is reported and clinical validation remains an unmet prerequisite. Improvement driven by new AI research guidelines is expected. However, these guidelines are covering only a part of AI approaches (nonsymbolic) reported in this review; hence, updates need to be considered.
- 1 November 2021
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 49 (11) , 872-873
Hémopéritoine aigu dans les suites d’un amniodrainage du troisième trimestre : à propos d’un cas
- 1 November 2021
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 49 (11) , 872-873
Hémopéritoine aigu dans les suites d’un amniodrainage du troisième trimestre : à propos d’un cas
- Open Access
- 1 March 2021
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 49 (3) , 208-212
Comment je fais…une transfusion in utero ?
- 1 March 2021
- Published by Elsevier in Gynécologie Obstétrique Fertilité & Sénologie
- Vol. 49 (3) , 208-212
Open AccessComment je fais…une transfusion in utero ?
- Open Access
- 3 July 2019
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 21 (7) , e14286
A Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Early pregnancy ultrasound scans are usually performed by non-expert examiners in OB/GYN emergency departments. Establishing the precise location diagnosis is key for appropriate management of early pregnancies, and experts are usually able to locate pregnancy at the first scan. A decision support system based on semantic expert-validated knowledge base may improve diagnosis performance of non-expert examiners, for early pregnancy transvaginal ultrasound. Objective: This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound on pregnancy location diagnosis and on image quality. Methods: Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases without and with the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. Pregnancy location diagnosis and ultrasound image quality was compared in scan performed without and with the system. Results: Each trainee performed a virtual vaginal examination for all 32 cases without and with the system. The analysis of the 128 resulting scans showed higher quality for the images (quality score +23%, p<0.001), less images per scan (4.6 vs. 6.3, p <0.001) and higher confidence in report conclusions (trust score +20%, p<.0001), when using the system. The use of the system cost an additional 8 minutes per scan. We observed a correct location diagnosis in 39/64 (61%) and 52/64 (81%) scans, in non-assisted mode and in assisted mode, respectively. Additionally, the exact diagnosis (with precise ectopic location) was achieved in 30/64 and 49/64 scans, without and with the system, respectively. These differences in diagnosis performance, +20% of correct location diagnosis and +30% in exact diagnosis were both statistically significant (p=0.002 and p<0.001, respectively). Conclusions: The Intelligent Scan Assistant System based on an expert-validated knowledge base demonstrates significant improvement in early pregnancy scan both in diagnosis performance (pregnancy location and precise diagnosis) and in scan quality (selection of images, confidence and image quality). Clinical Trial: N/A
- 3 July 2019
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 21 (7) , e14286
Open AccessA Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Early pregnancy ultrasound scans are usually performed by non-expert examiners in OB/GYN emergency departments. Establishing the precise location diagnosis is key for appropriate management of early pregnancies, and experts are usually able to locate pregnancy at the first scan. A decision support system based on semantic expert-validated knowledge base may improve diagnosis performance of non-expert examiners, for early pregnancy transvaginal ultrasound. Objective: This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound on pregnancy location diagnosis and on image quality. Methods: Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases without and with the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. Pregnancy location diagnosis and ultrasound image quality was compared in scan performed without and with the system. Results: Each trainee performed a virtual vaginal examination for all 32 cases without and with the system. The analysis of the 128 resulting scans showed higher quality for the images (quality score +23%, p<0.001), less images per scan (4.6 vs. 6.3, p <0.001) and higher confidence in report conclusions (trust score +20%, p<.0001), when using the system. The use of the system cost an additional 8 minutes per scan. We observed a correct location diagnosis in 39/64 (61%) and 52/64 (81%) scans, in non-assisted mode and in assisted mode, respectively. Additionally, the exact diagnosis (with precise ectopic location) was achieved in 30/64 and 49/64 scans, without and with the system, respectively. These differences in diagnosis performance, +20% of correct location diagnosis and +30% in exact diagnosis were both statistically significant (p=0.002 and p<0.001, respectively). Conclusions: The Intelligent Scan Assistant System based on an expert-validated knowledge base demonstrates significant improvement in early pregnancy scan both in diagnosis performance (pregnancy location and precise diagnosis) and in scan quality (selection of images, confidence and image quality). Clinical Trial: N/A
- Open Access
- 5 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
A Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study (Preprint)
BACKGROUND Early pregnancy ultrasound scans are usually performed by nonexpert examiners in obstetrics/gynecology (OB/GYN) emergency departments. Establishing the precise diagnosis of pregnancy location is key for appropriate management of early pregnancies, and experts are usually able to locate a pregnancy in the first scan. A decision-support system based on a semantic, expert-validated knowledge base may improve the diagnostic performance of nonexpert examiners for early pregnancy transvaginal ultrasound. OBJECTIVE This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound to diagnose the pregnancy location and determine the image quality. METHODS Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases with and without the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. A diagnosis of pregnancy location and ultrasound image quality were compared between scans performed with and without the system. RESULTS Each trainee performed a virtual vaginal examination for all 32 cases with and without use of the system. The analysis of the 128 resulting scans showed higher quality of the images (quality score: +23%; P<.001), less images per scan (4.6 vs 6.3 [without the CDSS]; P<.001), and higher confidence in reporting conclusions (trust score: +20%; P<.001) with use of the system. Further, use of the system cost an additional 8 minutes per scan. We observed a correct diagnosis of pregnancy location in 39 (61%) and 52 (81%) of 64 scans in the nonassisted mode and assisted mode, respectively. Additionally, an exact diagnosis (with precise ectopic location) was made in 30 (47%) and 49 (73%) of the 64 scans without and with use of the system, respectively. These differences in diagnostic performance (+20% for correct location diagnosis and +30% for exact diagnosis) were both statistically significant (P=.002 and P<.001, respectively). CONCLUSIONS The Intelligent Scan Assistant System is based on an expert-validated knowledge base and demonstrates significant improvement in early pregnancy scanning, both in diagnostic performance (pregnancy location and precise diagnosis) and scan quality (selection of images, confidence, and image quality).
- 5 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study (Preprint)
BACKGROUND Early pregnancy ultrasound scans are usually performed by nonexpert examiners in obstetrics/gynecology (OB/GYN) emergency departments. Establishing the precise diagnosis of pregnancy location is key for appropriate management of early pregnancies, and experts are usually able to locate a pregnancy in the first scan. A decision-support system based on a semantic, expert-validated knowledge base may improve the diagnostic performance of nonexpert examiners for early pregnancy transvaginal ultrasound. OBJECTIVE This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound to diagnose the pregnancy location and determine the image quality. METHODS Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases with and without the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. A diagnosis of pregnancy location and ultrasound image quality were compared between scans performed with and without the system. RESULTS Each trainee performed a virtual vaginal examination for all 32 cases with and without use of the system. The analysis of the 128 resulting scans showed higher quality of the images (quality score: +23%; P<.001), less images per scan (4.6 vs 6.3 [without the CDSS]; P<.001), and higher confidence in reporting conclusions (trust score: +20%; P<.001) with use of the system. Further, use of the system cost an additional 8 minutes per scan. We observed a correct diagnosis of pregnancy location in 39 (61%) and 52 (81%) of 64 scans in the nonassisted mode and assisted mode, respectively. Additionally, an exact diagnosis (with precise ectopic location) was made in 30 (47%) and 49 (73%) of the 64 scans without and with use of the system, respectively. These differences in diagnostic performance (+20% for correct location diagnosis and +30% for exact diagnosis) were both statistically significant (P=.002 and P<.001, respectively). CONCLUSIONS The Intelligent Scan Assistant System is based on an expert-validated knowledge base and demonstrates significant improvement in early pregnancy scanning, both in diagnostic performance (pregnancy location and precise diagnosis) and scan quality (selection of images, confidence, and image quality).