Loriane Franchinard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Loriane Franchinard has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ferdinand Dhombres
Sorbonne Université, Université Paris 13, Sorbonne Paris Cité, INSERM, UMR_S 1142, LIMICS, Paris, France
3 shared publications - Jean-Marie Jouannic
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
3 shared publications - Lucie Guilbaud
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
3 shared publications - Paul Maurice
Fetal Medicine Department Armand Trousseau Hospital Sorbonne University AP‐HP Paris France
3 shared publications Agnès Mailloux
Fetal and Perinatal Hemobiology Department St Antoine Hospital Sorbonne University AP‐HP Paris France
2 shared publications- Babak Khoshnood
Université Paris Cité and Université Sorbonne Paris Nord, INSERM, INRAE, Centre for Research in Epidemiology and Statistics Paris France
2 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Wiley in Prenatal Diagnosis
Biological Specificities of Fetal Anemia Induced by Parvovirus B19 Infection
Objective: To describe the biological fetal parameters in cases of severe anemia induced by parvovirus B19 (B19V) infection. Method: A retrospective single center study was conducted including cases of fetal anemia due to B19V receiving in utero transfusion (IUT) from January 2011 to May 2024. Biological data from fetal blood at first IUT were collected. Results: 65 cases were included. Median Hemoglobin was 3 g/dL [IQR 2.1–3.8] and median reticulocyte count was low (39.9 G/L [IQR 17.0–71.1]). Lymphopenia and elevated erythroblasts were noted in 37.5% and 59.1% of cases, respectively. High Aspartate aminotransferase (AST) levels and hypoproteinemia were observed in 97.6% and 71.4% of cases, respectively. The median lactate dehydrogenase (LDH) level was high (1556.0 U/L [IQR 611.0–2405.0]). Hydropic fetuses significantly exhibited lower hemoglobin levels (median 2.5 g/dL vs. 3.8 g/dL; p = 0.0315), lower platelet counts (median 30.5 G/L vs. 71.5 G/L; p = 0.0014), higher AST (median 97.0 vs. 20.0 U/L; p = 0.0002) and LDH levels (median 2068 vs. 329.5 U/L; p = 0.0002) compared to non‐hydropic cases. Conclusion: Severe fetal anemia due to B19V infection is associated with specific hematological and biochemical anomalies, some of which are more pronounced in case of hydrops.
- 10 October 2026
- Published by Wiley in Prenatal Diagnosis
Open AccessBiological Specificities of Fetal Anemia Induced by Parvovirus B19 Infection
Objective: To describe the biological fetal parameters in cases of severe anemia induced by parvovirus B19 (B19V) infection. Method: A retrospective single center study was conducted including cases of fetal anemia due to B19V receiving in utero transfusion (IUT) from January 2011 to May 2024. Biological data from fetal blood at first IUT were collected. Results: 65 cases were included. Median Hemoglobin was 3 g/dL [IQR 2.1–3.8] and median reticulocyte count was low (39.9 G/L [IQR 17.0–71.1]). Lymphopenia and elevated erythroblasts were noted in 37.5% and 59.1% of cases, respectively. High Aspartate aminotransferase (AST) levels and hypoproteinemia were observed in 97.6% and 71.4% of cases, respectively. The median lactate dehydrogenase (LDH) level was high (1556.0 U/L [IQR 611.0–2405.0]). Hydropic fetuses significantly exhibited lower hemoglobin levels (median 2.5 g/dL vs. 3.8 g/dL; p = 0.0315), lower platelet counts (median 30.5 G/L vs. 71.5 G/L; p = 0.0014), higher AST (median 97.0 vs. 20.0 U/L; p = 0.0002) and LDH levels (median 2068 vs. 329.5 U/L; p = 0.0002) compared to non‐hydropic cases. Conclusion: Severe fetal anemia due to B19V infection is associated with specific hematological and biochemical anomalies, some of which are more pronounced in case of hydrops.
- 7 November 2021
- Published by Wiley in Vox Sanguinis
- Vol. 117 (4) , 570-579
Perinatal risk factors associated with severity of haemolytic disease of the foetus and newborn due to Rhc maternal‐foetal incompatibility: A retrospective cohort study
Background and Objectives: Anti‐c is the third red blood cell antibody responsible for haemolytic disease of the foetus and newborn (HDFN) requiring intrauterine transfusion. We aimed to identify risk factors associated with HDFN and severe HDFN due to Rhc maternal‐foetal incompatibility.Materials and Methods: A retrospective cohort study was conducted in Paris and the surrounding area (France), between 2013 and 2015. We included mothers and their children managed by the National Reference Centre in Perinatal Hemobiology for alloimmunization and maternal‐foetal incompatibility for the Rhc antigen (N = 121). We conducted bivariate analyses to assess a relationship between perinatal factors (e.g., titre and concentration of anti‐c antibodies, direct antiglobulin test) and HDFN, its severity and duration.Results: The incidence of HDFN was 30% (n = 36), including 11% of severe HDFN (n = 13). Seven percent (n = 9) of neonates received at least one transfusion during the first week and 21% (n = 26) after this period until 3 weeks of life. During pregnancy, a concentration ≥7.5 IU/ml and a titre ≥4 and above were associated with HDFN and severe HDFN (p < 0.05). At birth, the high intensity of the quantitative direct antiglobulin test was associated with HDFN and severe HDFN (p < 0.05). A concentration ≥15 IU/ml is the best factor (area under curve [AUC] = 0.78) in predicting HDFN, followed by a titre ≥8 (AUC = 0.76).Conclusion: Anti‐c alloimmunization causes neonatal anaemia, which is often belated. Paediatricians have to be aware of these risk factors and organize prolonged monitoring of neonates.
- 7 November 2021
- Published by Wiley in Vox Sanguinis
- Vol. 117 (4) , 570-579
Perinatal risk factors associated with severity of haemolytic disease of the foetus and newborn due to Rhc maternal‐foetal incompatibility: A retrospective cohort study
Background and Objectives: Anti‐c is the third red blood cell antibody responsible for haemolytic disease of the foetus and newborn (HDFN) requiring intrauterine transfusion. We aimed to identify risk factors associated with HDFN and severe HDFN due to Rhc maternal‐foetal incompatibility.Materials and Methods: A retrospective cohort study was conducted in Paris and the surrounding area (France), between 2013 and 2015. We included mothers and their children managed by the National Reference Centre in Perinatal Hemobiology for alloimmunization and maternal‐foetal incompatibility for the Rhc antigen (N = 121). We conducted bivariate analyses to assess a relationship between perinatal factors (e.g., titre and concentration of anti‐c antibodies, direct antiglobulin test) and HDFN, its severity and duration.Results: The incidence of HDFN was 30% (n = 36), including 11% of severe HDFN (n = 13). Seven percent (n = 9) of neonates received at least one transfusion during the first week and 21% (n = 26) after this period until 3 weeks of life. During pregnancy, a concentration ≥7.5 IU/ml and a titre ≥4 and above were associated with HDFN and severe HDFN (p < 0.05). At birth, the high intensity of the quantitative direct antiglobulin test was associated with HDFN and severe HDFN (p < 0.05). A concentration ≥15 IU/ml is the best factor (area under curve [AUC] = 0.78) in predicting HDFN, followed by a titre ≥8 (AUC = 0.76).Conclusion: Anti‐c alloimmunization causes neonatal anaemia, which is often belated. Paediatricians have to be aware of these risk factors and organize prolonged monitoring of neonates.
- Open Access
- 3 July 2019
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 21 (7) , e14286
A Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Early pregnancy ultrasound scans are usually performed by non-expert examiners in OB/GYN emergency departments. Establishing the precise location diagnosis is key for appropriate management of early pregnancies, and experts are usually able to locate pregnancy at the first scan. A decision support system based on semantic expert-validated knowledge base may improve diagnosis performance of non-expert examiners, for early pregnancy transvaginal ultrasound. Objective: This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound on pregnancy location diagnosis and on image quality. Methods: Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases without and with the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. Pregnancy location diagnosis and ultrasound image quality was compared in scan performed without and with the system. Results: Each trainee performed a virtual vaginal examination for all 32 cases without and with the system. The analysis of the 128 resulting scans showed higher quality for the images (quality score +23%, p<0.001), less images per scan (4.6 vs. 6.3, p <0.001) and higher confidence in report conclusions (trust score +20%, p<.0001), when using the system. The use of the system cost an additional 8 minutes per scan. We observed a correct location diagnosis in 39/64 (61%) and 52/64 (81%) scans, in non-assisted mode and in assisted mode, respectively. Additionally, the exact diagnosis (with precise ectopic location) was achieved in 30/64 and 49/64 scans, without and with the system, respectively. These differences in diagnosis performance, +20% of correct location diagnosis and +30% in exact diagnosis were both statistically significant (p=0.002 and p<0.001, respectively). Conclusions: The Intelligent Scan Assistant System based on an expert-validated knowledge base demonstrates significant improvement in early pregnancy scan both in diagnosis performance (pregnancy location and precise diagnosis) and in scan quality (selection of images, confidence and image quality). Clinical Trial: N/A
- 3 July 2019
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 21 (7) , e14286
Open AccessA Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Early pregnancy ultrasound scans are usually performed by non-expert examiners in OB/GYN emergency departments. Establishing the precise location diagnosis is key for appropriate management of early pregnancies, and experts are usually able to locate pregnancy at the first scan. A decision support system based on semantic expert-validated knowledge base may improve diagnosis performance of non-expert examiners, for early pregnancy transvaginal ultrasound. Objective: This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound on pregnancy location diagnosis and on image quality. Methods: Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases without and with the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. Pregnancy location diagnosis and ultrasound image quality was compared in scan performed without and with the system. Results: Each trainee performed a virtual vaginal examination for all 32 cases without and with the system. The analysis of the 128 resulting scans showed higher quality for the images (quality score +23%, p<0.001), less images per scan (4.6 vs. 6.3, p <0.001) and higher confidence in report conclusions (trust score +20%, p<.0001), when using the system. The use of the system cost an additional 8 minutes per scan. We observed a correct location diagnosis in 39/64 (61%) and 52/64 (81%) scans, in non-assisted mode and in assisted mode, respectively. Additionally, the exact diagnosis (with precise ectopic location) was achieved in 30/64 and 49/64 scans, without and with the system, respectively. These differences in diagnosis performance, +20% of correct location diagnosis and +30% in exact diagnosis were both statistically significant (p=0.002 and p<0.001, respectively). Conclusions: The Intelligent Scan Assistant System based on an expert-validated knowledge base demonstrates significant improvement in early pregnancy scan both in diagnosis performance (pregnancy location and precise diagnosis) and in scan quality (selection of images, confidence and image quality). Clinical Trial: N/A
- Open Access
- 5 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
A Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study (Preprint)
BACKGROUND Early pregnancy ultrasound scans are usually performed by nonexpert examiners in obstetrics/gynecology (OB/GYN) emergency departments. Establishing the precise diagnosis of pregnancy location is key for appropriate management of early pregnancies, and experts are usually able to locate a pregnancy in the first scan. A decision-support system based on a semantic, expert-validated knowledge base may improve the diagnostic performance of nonexpert examiners for early pregnancy transvaginal ultrasound. OBJECTIVE This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound to diagnose the pregnancy location and determine the image quality. METHODS Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases with and without the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. A diagnosis of pregnancy location and ultrasound image quality were compared between scans performed with and without the system. RESULTS Each trainee performed a virtual vaginal examination for all 32 cases with and without use of the system. The analysis of the 128 resulting scans showed higher quality of the images (quality score: +23%; P<.001), less images per scan (4.6 vs 6.3 [without the CDSS]; P<.001), and higher confidence in reporting conclusions (trust score: +20%; P<.001) with use of the system. Further, use of the system cost an additional 8 minutes per scan. We observed a correct diagnosis of pregnancy location in 39 (61%) and 52 (81%) of 64 scans in the nonassisted mode and assisted mode, respectively. Additionally, an exact diagnosis (with precise ectopic location) was made in 30 (47%) and 49 (73%) of the 64 scans without and with use of the system, respectively. These differences in diagnostic performance (+20% for correct location diagnosis and +30% for exact diagnosis) were both statistically significant (P=.002 and P<.001, respectively). CONCLUSIONS The Intelligent Scan Assistant System is based on an expert-validated knowledge base and demonstrates significant improvement in early pregnancy scanning, both in diagnostic performance (pregnancy location and precise diagnosis) and scan quality (selection of images, confidence, and image quality).
- 5 April 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Novel Intelligent Scan Assistant System for Early Pregnancy Diagnosis by Ultrasound: Clinical Decision Support System Evaluation Study (Preprint)
BACKGROUND Early pregnancy ultrasound scans are usually performed by nonexpert examiners in obstetrics/gynecology (OB/GYN) emergency departments. Establishing the precise diagnosis of pregnancy location is key for appropriate management of early pregnancies, and experts are usually able to locate a pregnancy in the first scan. A decision-support system based on a semantic, expert-validated knowledge base may improve the diagnostic performance of nonexpert examiners for early pregnancy transvaginal ultrasound. OBJECTIVE This study aims to evaluate a novel Intelligent Scan Assistant System for early pregnancy ultrasound to diagnose the pregnancy location and determine the image quality. METHODS Two trainees performed virtual transvaginal ultrasound examinations of early pregnancy cases with and without the system. The ultrasound images and reports were blindly reviewed by two experts using scoring methods. A diagnosis of pregnancy location and ultrasound image quality were compared between scans performed with and without the system. RESULTS Each trainee performed a virtual vaginal examination for all 32 cases with and without use of the system. The analysis of the 128 resulting scans showed higher quality of the images (quality score: +23%; P<.001), less images per scan (4.6 vs 6.3 [without the CDSS]; P<.001), and higher confidence in reporting conclusions (trust score: +20%; P<.001) with use of the system. Further, use of the system cost an additional 8 minutes per scan. We observed a correct diagnosis of pregnancy location in 39 (61%) and 52 (81%) of 64 scans in the nonassisted mode and assisted mode, respectively. Additionally, an exact diagnosis (with precise ectopic location) was made in 30 (47%) and 49 (73%) of the 64 scans without and with use of the system, respectively. These differences in diagnostic performance (+20% for correct location diagnosis and +30% for exact diagnosis) were both statistically significant (P=.002 and P<.001, respectively). CONCLUSIONS The Intelligent Scan Assistant System is based on an expert-validated knowledge base and demonstrates significant improvement in early pregnancy scanning, both in diagnostic performance (pregnancy location and precise diagnosis) and scan quality (selection of images, confidence, and image quality).