ESErhan Sezgin

Erhan Sezgin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Erhan Sezgin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhanced Frequency and Harmonic Estimation for Electric Arc Furnace Measurements: A Least Squares Approach to Mitigate Spectral Leakage

    by Erhan Sezgin, Özgül Salor

    In this paper, a Least Squares (LS) based harmonic and frequency estimation method is proposed to analyze power signals with rapidly changing characteristics in time such as Electric Arc Furnaces (EAFs) as an alternative to the classical Discrete Fourier Transform (DFT)-based methods. Although DFT based harmonic analysis methods provide fast and accurate solutions for stationary signals, solutions become less accurate under frequency deviations especially when the signal is sampled at low rates. This paper presents an approach which can accurately calculate the harmonic components of the signals, when the fundamental periods cannot be expressed as integer numbers due to the low sampling rate. One of the outstanding parts of the proposed approach is that, it is possible to increase the performance of harmonic and interharmonic estimation by increasing the performance of frequency estimation with LS technique in cases of rapidly time varying signals such as EAF currents and voltages. The reliability of the proposed approach is proven with synthetically and realistically generated EAF current signals and the results are also evaluated by running the method on field measurements collected at transformer substations supplying EAF plants both for harmonics and interharmonics estimation. Compatibility of the proposed method with parallel processing is also investigated to prove its usability in real-time applications.


  • Fast harmonic analysis for PHIL experiments with decentralized real-time controllers

    by Erhan Sezgin, Anurag Mohapatra, Thomas Hamacher, Özgül Salor, Vedran S. Perić


  • Open Access

    Fast harmonic analysis for PHIL experiments with decentralized real-time controllers

    by Erhan Sezgin, Anurag Mohapatra, Vedran S. Peric, Ozgül Salor, Thomas Hamacher

    The paper has been submitted to PSCC 2022 and is currently awaiting reviews. This paper proposes and implements, a harmonic analysis algorithm for microgrid Power Hardware-in-the-loop (PHIL) experiments, when the point of common coupling (PCC) voltage cannot be directly wired to the local prosumer controllers due to long distances between them. Using frequency-shifting and filtering ideas, the voltage measurement is converted to magnitude and phase information. This is passed over an asynchronous communication link to another controller, where it is recovered into a waveform after delay compensation. The method allows for accurate power calculations and grid synchronization over distributed prosumer controllers. The proposed method can work at different execution rates depending on real time (RT) workload and is shown to be robust against step changes, harmonics and communication delays. The method is demonstrated with two PHIL experiments at the CoSES, TU Munich lab in grid connected and island mode.

  • Analysis of Power System Harmonic Subgroups of the Electric Arc Furnace Currents Based on a Hybrid Time-Frequency Analysis Method

    by Erhan Sezgin, Ozgul Salor

    In this paper, a hybrid time-frequency analysis method, specially developed to decompose harmonic subgroups and interharmonics of the electric arc furnace (EAF) currents, which are highly time varying due to the operation principles of the EAFs, is presented. The main objective is accurate perception of harmonics and interharmonics in cases of rapid changes or power quality (PQ) events in power system voltages and currents. Harmonic and interharmonics detection has been achieved using discrete wavelet transform (DWT), which provides time-localization in cases of highly time-varying signals. Although DWT elicits accurate spectral decomposition at low frequencies, and especially at the baseband, bandwidths of the band-pass filters increase which results in loss of accuracy at higher frequencies. In order to avoid this problem, power signals are modulated by complex exponential waveforms, which corresponds to shifting the required harmonic sub-band contents to the baseband, where the accuracy of the DWT is the best. Using the proposed hybrid combination of DWT and complex exponential modulation, time domain waveform of each harmonic sub-band of the EAF currents can be estimated close to ideal values. The method also enables to focus on any required interharmonic sub-band in addition to the harmonics. To optimize the performance of the DWT in cases of PQ events, various windowing approaches are discussed. The proposed harmonic and interharmonic estimation method has been verified on both synthetic data and EAF currents collected from the electricity transmission system. Estimated harmonic and interharmonic waveforms can serve as a good reference in many areas including active power filtering operations, limit violation determinations, etc., in the power system.


  • Analysis of Power System Harmonic Subgroups of the Electric Arc Furnace Currents Based on a Hybrid Time-Frequency Analysis Method

    by Erhan Sezgin, Ozgul Salor

    In this paper, a hybrid time-frequency analysis method is developed to extract the time domain waveform of the harmonic subgroups of the electric arc furnace (EAF) currents so as to serve as reference signals for the active power filters to suppress highly time-varying harmonics and interharmonics being eventuated in power systems by the EAFs. Contrary to classical frequency analysis, in this work, the aim is the detection of harmonics and interharmonics subject to fast changes or sudden events in power system signals. Discrete Wavelet Transform (DWT) based methods have been investigated and utilized in harmonic decomposition operations in many studies carried out so far. Despite being useful at low frequencies, in DWT bandwidth of the analysis bands increases and hence frequency resolution decreases at high frequencies. In this study, to overcome this inefficacy, power signals are modified by a complex exponential modulation technique, which corresponds to shifting harmonic contents to lower and higher frequency bands. With the combination of the modulation with wavelet decomposition, time domain waveform of each frequency band of the EAF currents, which are rich in time-varying harmonics and interharmonics, can be estimated almost ideally. The proposed harmonic and interharmonic estimation method has been verified on both synthetic data and EAF currents collected from the electricity transmission system. Estimated harmonic and interharmonic waveforms can serve as a good reference in many areas including active power filtering operations, limit violation determinations, and etc. in the power system.


  • State-Estimation-Based Determination of Harmonic Current Contributions of Iron and Steel Plants Supplied from PCC

    by Erhan Sezgin, Murat Gol, Ozgul Salor

    In this paper, a state-estimation-based method is proposed to determine harmonic current contributions of iron and steel (I&S) plants supplied from a point of common coupling (PCC). Due to highly nonlinear nature of the I&S plant operation, accurate estimation of harmonic contributions of the individual plants is essential. In the proposed method, the nonlinear characteristics of the plants and the utility are modeled as harmonic current sources and the harmonic current contributions of loads are decoupled from the upstream effects on the basis of the sample-by-sample time-synchronized field measurements of load currents and voltage signals. Being a field-measurement-based method, it is necessary to mitigate the measurement errors of conventional voltage transformers (CVTs) at harmonic frequencies. Gross error of voltage transformers is reduced through calibration, while weighted least squares (WLS) state estimation is used to reduce the Gaussian error of the current transformer and calibrated voltage transformer measurements. Using the estimated harmonic voltages and currents, harmonic contributions of all plants are determined by employing the Norton equivalent circuits of the plants together with the superposition theorem. The results have shown that the proposed method can be used as a successful estimation tool to determine the harmonic current contributions of all I&S plants supplied from the PCC. The proposed method eliminates the need for the usage of resistive-capacitive voltage transformers (RCVTs) for accurate harmonic voltage measurements, which are expensive and cumbersome, while reducing the Gaussian measurement error of conventional voltage and current transformers at the same time; hence, it provides accurate harmonic contributions of the electric arc furnace (EAF) plants.


  • State estimation based determination of harmonic current contributions of iron and steel plants supplied from PCC

    by Erhan Sezgin, Murat Gol, Ozgul Salor

    In this paper, a state estimation based method is proposed to determine harmonic current contributions of iron and steel (I&S) plants supplied from a Point of Common Coupling (PCC). Due to highly nonlinear nature of the iron and steel plant operation, accurate estimation of the harmonic contributions of the individual plants is essential. In the proposed method, the nonlinear characteristics of the plants and the utility are modeled as harmonic current sources and the harmonic current contributions of loads are decoupled from the upstream effects on the basis of the sample-by-sample time-synchronized field measurements of load currents and voltage signals. Being a field-measurement-based method, it is necessary to mitigate the measurement errors of conventional voltage transformers at harmonic frequencies. Gross error of voltage transformers is reduced through calibration, while weighted least squares state estimation is used to reduce the Gaussian error of the current transformer and calibrated voltage transformer measurements. Using the estimated harmonic voltages and currents, harmonic contributions of all plants are determined by employing the Norton equivalent circuits of the plants together with the superposition theorem. The results have shown that the proposed method can be used as a successful estimation tool to determine the harmonic current contributions of all I&S plants supplied from the PCC. The proposed method eliminates the need for the usage of resistive-capacitive voltage transformers for accurate harmonic voltage measurements, which are expensive and cumbersome, while reducing the Gaussian measurement error of conventional voltage and current transformers at the same time, hence it provides accurate harmonic contributions of the EAF plants.


  • Determination of harmonic current contributions of plants supplied from PCC based on state estimation

    by Erhan Sezgin, Murat Gol, Ozgul Salor

    In this paper, a state estimation based method is proposed to determine harmonic current contributions of plants supplied from a Point of Common Coupling (PCC). By using Weighted Least Squares (WLS) state estimation, it is aimed to improve harmonic voltage measurements acquired from conventional voltage transformers, which are employed commonly in the power systems. Using measured harmonic currents and estimated harmonic voltages, harmonic contributions of all plants have been determined by employing the Norton equivalent circuits of the plants and the superposition theorem. Absence of reliable harmonic voltage measurements necessitates employing harmonic filter current measured from at least one of the plants. Using the new measurement set built after the estimation process, a model to determine the harmonic current contribution of plants supplied from a PCC has been developed.