Kwai Peng Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kwai Peng Chan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Judith Chui Ching Wong
Environmental Health Institute, National Environment Agency, Singapore
3 shared publications Chai Teng Tan
HIV Reference Laboratory, Virology Laboratory, Department of Microbiology, Division of Pathology, Singapore General Hospital, Singapore, Singapore
1 shared publicationJoanne Su Lin Kang
National Environment Agency, Environmental Health Institute, Singapore
1 shared publicationKian Sing Chan
Department of Molecular Pathology Singapore General Hospital Singapore
1 shared publicationKun Lee Lim
Department of Molecular Pathology Singapore General Hospital Singapore
1 shared publicationLynette Lin Ean Oon
Department of Molecular Pathology Singapore General Hospital Singapore
1 shared publication
Latest Publications
- 14 August 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (6) , 3738-3743
Hepatitis C virus antigen detection is an appropriate test for screening and early diagnosis of hepatitis C virus infection in at‐risk populations and immunocompromised hosts
Early diagnosis remains key for effective prevention and treatment. Unfortunately, current screening with anti‐hepatitis C virus antibody (anti‐HCV Ab) test may have limited utility in the diagnosis of HCV infection and reinfection. This is of special concern to at‐risk population, such as immunocompromised hosts and end‐stage renal failure patients on hemodialysis. HCV antigen (Ag) could be useful in identifying the ongoing infection in such clinical scenarios. Hence, we aimed to study the utility of HCV Ag testing for the diagnosis of acute and chronic hepatitis C. Of 89 samples studied, 19 were from acute hepatitis C patients who were immunocompromised or were on hemodialysis, 43 were from active chronic hepatitis C patients and 27 were from patients treated for chronic hepatitis C. All samples were tested for HCV Ag using the Abbott ARCHITECT HCV Ag assay. HCV Ag was reactive in 19/19 samples from acute hepatitis C patients and 42/43 samples from active chronic hepatitis C patients. It was nonreactive in all samples from treated patients. The test showed a sensitivity and specificity of 98.4% and 100.0%, respectively. The positive and negative predictive values were 100.0% and 96.4%, respectively. The HCV antigen test has high clinical sensitivity and specificity and is useful for the diagnosis of acute and chronic hepatitis C infection in at‐risk and immunocompromised patients. Its short turnaround time and relatively low cost are advantageous for use in patients on hemodialysis and other at‐risk patients who require monitoring of HCV infection and reinfection.
- 14 August 2020
- Published by Wiley in Journal of Medical Virology
- Vol. 93 (6) , 3738-3743
Hepatitis C virus antigen detection is an appropriate test for screening and early diagnosis of hepatitis C virus infection in at‐risk populations and immunocompromised hosts
Early diagnosis remains key for effective prevention and treatment. Unfortunately, current screening with anti‐hepatitis C virus antibody (anti‐HCV Ab) test may have limited utility in the diagnosis of HCV infection and reinfection. This is of special concern to at‐risk population, such as immunocompromised hosts and end‐stage renal failure patients on hemodialysis. HCV antigen (Ag) could be useful in identifying the ongoing infection in such clinical scenarios. Hence, we aimed to study the utility of HCV Ag testing for the diagnosis of acute and chronic hepatitis C. Of 89 samples studied, 19 were from acute hepatitis C patients who were immunocompromised or were on hemodialysis, 43 were from active chronic hepatitis C patients and 27 were from patients treated for chronic hepatitis C. All samples were tested for HCV Ag using the Abbott ARCHITECT HCV Ag assay. HCV Ag was reactive in 19/19 samples from acute hepatitis C patients and 42/43 samples from active chronic hepatitis C patients. It was nonreactive in all samples from treated patients. The test showed a sensitivity and specificity of 98.4% and 100.0%, respectively. The positive and negative predictive values were 100.0% and 96.4%, respectively. The HCV antigen test has high clinical sensitivity and specificity and is useful for the diagnosis of acute and chronic hepatitis C infection in at‐risk and immunocompromised patients. Its short turnaround time and relatively low cost are advantageous for use in patients on hemodialysis and other at‐risk patients who require monitoring of HCV infection and reinfection.
- 11 July 2019
- Published by Wiley in Zoonoses and Public Health
- Vol. 66 (7) , 773-782
Seroepidemiology and genotyping of hepatitis E virus in Singapore reveal rise in number of cases and similarity of human strains to those detected in pig livers
Hepatitis E virus (HEV) causes 20 million infections worldwide yearly, of which only about 3.3 million are symptomatic. In developed Asian countries, HEV strains detected in human sera and in food sources were genetically similar, suggesting that indigenous HEV infections may be largely food‐borne. To assess the burden of hepatitis E in Singapore, we performed a seroepidemiologic study of the infection. Additionally, we carried out HEV genotyping on archived, residual HEV IgM‐positive serum samples collected between 2014 and 2016 (n = 449), and on pig liver samples (n = 36) purchased from wet markets and supermarkets. Our study shows a rise in hepatitis E incidence (IgM) from 1.7 to 4.1 cases per 100,000 resident population from 2012 to 2016 and an increase in hepatitis E IgG positivity rate among residents from 14% in 2007 to 35% in 2016. Other findings also suggest the epidemiology of hepatitis E in Singapore has shifted, from it being mainly a disease imported from the Indian subcontinent, to one that is now increasingly prevalent in our resident population. Genotypes obtained from 143 human samples identified the majority to be genotype 3 (n = 121), 21 to be genotype 1 and one to be genotype 4. Further phylogenetic analyses suggest genotype 3a to be the cause of indigenous infections in residents, which showed genetic similarity to the genotype 3a strains detected in pig livers. This link between the strains in the majority of human samples and those in pig livers consumed by the public suggests a possible food‐borne route of HEV infection in Singapore.
- 11 July 2019
- Published by Wiley in Zoonoses and Public Health
- Vol. 66 (7) , 773-782
Seroepidemiology and genotyping of hepatitis E virus in Singapore reveal rise in number of cases and similarity of human strains to those detected in pig livers
Hepatitis E virus (HEV) causes 20 million infections worldwide yearly, of which only about 3.3 million are symptomatic. In developed Asian countries, HEV strains detected in human sera and in food sources were genetically similar, suggesting that indigenous HEV infections may be largely food‐borne. To assess the burden of hepatitis E in Singapore, we performed a seroepidemiologic study of the infection. Additionally, we carried out HEV genotyping on archived, residual HEV IgM‐positive serum samples collected between 2014 and 2016 (n = 449), and on pig liver samples (n = 36) purchased from wet markets and supermarkets. Our study shows a rise in hepatitis E incidence (IgM) from 1.7 to 4.1 cases per 100,000 resident population from 2012 to 2016 and an increase in hepatitis E IgG positivity rate among residents from 14% in 2007 to 35% in 2016. Other findings also suggest the epidemiology of hepatitis E in Singapore has shifted, from it being mainly a disease imported from the Indian subcontinent, to one that is now increasingly prevalent in our resident population. Genotypes obtained from 143 human samples identified the majority to be genotype 3 (n = 121), 21 to be genotype 1 and one to be genotype 4. Further phylogenetic analyses suggest genotype 3a to be the cause of indigenous infections in residents, which showed genetic similarity to the genotype 3a strains detected in pig livers. This link between the strains in the majority of human samples and those in pig livers consumed by the public suggests a possible food‐borne route of HEV infection in Singapore.
- Open Access
- 21 June 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (6) , e0199502
Performance of the HIV Blot 2.2, INNO-LIA HIV I/II Score, and Geenius HIV 1/2 Confirmatory Assay for use in HIV confirmation
In view of recent revised recommendations for human immunodeficiency virus (HIV) confirmatory testing, the performance of 3 HIV confirmatory assays was compared. Using the HIV Blot 2.2 (MP-WB), the INNO-LIA HIV I/II Score (INNO), and the Geenius HIV 1/2 Confirmatory Assay (Geenius), we tested 199 HIV-1 positive, 161 HIV negative, 65 HIV western blot indeterminate, 26 HIV seroconversion, 34 early HIV infection and 4 HIV-2 positive archived specimens. We show that all 3 assays had comparable test sensitivity in the detection of HIV-1 positive cases. However, less non-specific reactivity was observed with the INNO and Geenius assays, where both of them were able to resolve MP-WB indeterminate cases. When early HIV cases were considered, INNO and Geenius were more likely to confirm an early-stage infection as positive. Nevertheless, overall poor sensitivity (25.5% - 44.7%) of these assays for the detection of early cases was observed, likely because these cases had very low or non-detectable levels of HIV antibodies. Hence, further testing by a nucleic acid test or a p24 antigen test of specimens reactive on screening with a fourth generation Ag/Ab assay that are negative on confirmatory testing for HIV-specific antibody, may be useful. In conclusion, INNO and Geenius had comparable test performance, although the ease of use and shorter assay time for Geenius may make it the preferred choice for laboratories. In that regard, of note is our observation of non-specific reactivity of lipaemic specimens to the HIV-2 gp140 band in the Geenius assay, which should prompt caution when interpreting results of such specimens.
- 21 June 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (6) , e0199502
Open AccessPerformance of the HIV Blot 2.2, INNO-LIA HIV I/II Score, and Geenius HIV 1/2 Confirmatory Assay for use in HIV confirmation
In view of recent revised recommendations for human immunodeficiency virus (HIV) confirmatory testing, the performance of 3 HIV confirmatory assays was compared. Using the HIV Blot 2.2 (MP-WB), the INNO-LIA HIV I/II Score (INNO), and the Geenius HIV 1/2 Confirmatory Assay (Geenius), we tested 199 HIV-1 positive, 161 HIV negative, 65 HIV western blot indeterminate, 26 HIV seroconversion, 34 early HIV infection and 4 HIV-2 positive archived specimens. We show that all 3 assays had comparable test sensitivity in the detection of HIV-1 positive cases. However, less non-specific reactivity was observed with the INNO and Geenius assays, where both of them were able to resolve MP-WB indeterminate cases. When early HIV cases were considered, INNO and Geenius were more likely to confirm an early-stage infection as positive. Nevertheless, overall poor sensitivity (25.5% - 44.7%) of these assays for the detection of early cases was observed, likely because these cases had very low or non-detectable levels of HIV antibodies. Hence, further testing by a nucleic acid test or a p24 antigen test of specimens reactive on screening with a fourth generation Ag/Ab assay that are negative on confirmatory testing for HIV-specific antibody, may be useful. In conclusion, INNO and Geenius had comparable test performance, although the ease of use and shorter assay time for Geenius may make it the preferred choice for laboratories. In that regard, of note is our observation of non-specific reactivity of lipaemic specimens to the HIV-2 gp140 band in the Geenius assay, which should prompt caution when interpreting results of such specimens.