Yifeng Pei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yifeng Pei has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Liangliang Rong
Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
5 shared publications - Guofeng Zhang
Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
4 shared publications - Hui Dong
Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
4 shared publications - Jun Wu
Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
3 shared publications - Xiaoming Xie
Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Science, Shanghai, CHINA
3 shared publications - Yongliang Wang
Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences (CAS), Shanghai, China
3 shared publications
Latest Publications
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Sub-μm Sized Josephson Junctions Based LTS SQUID Receiver for Transient Electromagnetic Surveys
Superconducting Quantum Interference Device (SQUID) magnetometers combine low noise, wide bandwidth, and high tolerance to magnetic field slew rates. These characteristics significantly enhance the depth and accuracy of transient electromagnetic (TEM) surveys. In this paper, we developed a high-performance superconducting TEM receiver using low temperature superconductors (LTS) SQUID chips fabricated via sub-μm Josephson-junction integration. The design boosts sensor output amplitudes from tens of microvolts (μV) to over 200 μV. The SQUID sensors achieve a noise floor below 5 fT/√Hz, and the system tolerates magnetic field slew rates exceeding 5 mT/s. Side-by-side field tests comparing the system against a commercial Phoenix V8 multipurpose network electrical instrument equipped with an MTEM-AL induction coil showed approximately 30-fold improvement in effective late-time resolution. Additional validation surveys were conducted at two sites in China: a gold deposit concealed beneath conductive overburden in Anhui Province, and a deep copper deposit in Heilongjiang Province. The TEM results from both sites correlated well with borehole logs, demonstrating that SQUID-based TEM receiver can effectively explore targets beneath conductive cover and/or at greater depths.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Sub-μm Sized Josephson Junctions Based LTS SQUID Receiver for Transient Electromagnetic Surveys
Superconducting Quantum Interference Device (SQUID) magnetometers combine low noise, wide bandwidth, and high tolerance to magnetic field slew rates. These characteristics significantly enhance the depth and accuracy of transient electromagnetic (TEM) surveys. In this paper, we developed a high-performance superconducting TEM receiver using low temperature superconductors (LTS) SQUID chips fabricated via sub-μm Josephson-junction integration. The design boosts sensor output amplitudes from tens of microvolts (μV) to over 200 μV. The SQUID sensors achieve a noise floor below 5 fT/√Hz, and the system tolerates magnetic field slew rates exceeding 5 mT/s. Side-by-side field tests comparing the system against a commercial Phoenix V8 multipurpose network electrical instrument equipped with an MTEM-AL induction coil showed approximately 30-fold improvement in effective late-time resolution. Additional validation surveys were conducted at two sites in China: a gold deposit concealed beneath conductive overburden in Anhui Province, and a deep copper deposit in Heilongjiang Province. The TEM results from both sites correlated well with borehole logs, demonstrating that SQUID-based TEM receiver can effectively explore targets beneath conductive cover and/or at greater depths.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-5
Weakly Damped SQUID With Submicron Josephson Junctions
A superconducting quantum interference device (SQUID) consists of a superconducting loop interrupted by one or two Josephson junctions. Overdamped Josephson junctions, characterized by a Stewart–McCumber parameter (βc) below 1, are typically required as the key element of SQUIDs due to their nonhysteretic I–V characteristics. In the overdamped limit, the junction's shunt resistance is only a few ohms, leading to a SQUID voltage swing of just tens of μV. Consequently, connecting the SQUID to readout circuitry necessitates a complex noise-matching electronic circuit, such as those using flux modulation, adaptive positive feedback, or a SQUID bootstrap circuit. Here, we present a weakly damped SQUID designed for direct connection to the readout circuitry. This is achieved first by incorporating a submicron, low-capacitance Josephson junction, which allows the shunt resistance to be increased to tens of ohms. Second, the shunt resistance is increased further, resulting in a βc greater than 1, defining what is known as a weakly damped junction. This design achieves a high flux-to-voltage transfer coefficient of over 1 mV/Φ0, attributable to the increased voltage swing and a quasi-rectangular signal shape. As a result, the noise contribution from the preamplifier of the direct readout circuitry becomes negligible compared to the SQUID's intrinsic noise.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-5
Weakly Damped SQUID With Submicron Josephson Junctions
A superconducting quantum interference device (SQUID) consists of a superconducting loop interrupted by one or two Josephson junctions. Overdamped Josephson junctions, characterized by a Stewart–McCumber parameter (βc) below 1, are typically required as the key element of SQUIDs due to their nonhysteretic I–V characteristics. In the overdamped limit, the junction's shunt resistance is only a few ohms, leading to a SQUID voltage swing of just tens of μV. Consequently, connecting the SQUID to readout circuitry necessitates a complex noise-matching electronic circuit, such as those using flux modulation, adaptive positive feedback, or a SQUID bootstrap circuit. Here, we present a weakly damped SQUID designed for direct connection to the readout circuitry. This is achieved first by incorporating a submicron, low-capacitance Josephson junction, which allows the shunt resistance to be increased to tens of ohms. Second, the shunt resistance is increased further, resulting in a βc greater than 1, defining what is known as a weakly damped junction. This design achieves a high flux-to-voltage transfer coefficient of over 1 mV/Φ0, attributable to the increased voltage swing and a quasi-rectangular signal shape. As a result, the noise contribution from the preamplifier of the direct readout circuitry becomes negligible compared to the SQUID's intrinsic noise.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (8) , 1-5
Noise Compensation of a Mobile LTS SQUID Planar Gradiometer for Aeromagnetic Detection
A SQUID planar gradiometer is an extremely sensitive sensor for magnetic gradient measurements. It has been shown to have potential applications for aeromagnetic detection. The major challenge when operating an aeromagnetic SQUID system in actual environment is the motion noise, including the inherent response resulting from gradiometer imbalance and from magnetic interferences. Three orthogonal reference magnetometers are usually adopted to improve the gradiometer balance. However, magnetic interference coming from the system itself also needs to be compensated. In this paper, a mathematical model of the motion noise picked up by the gradiometer is derived from the traditional magnetic total field compensation method. Based on the model, the signals from the triaxial magnetometer can also be used to compensate the eddy current contribution to the magnetic interference. To verify the compensation method, a SQUID planar gradiometer system was set up and used for flight trials. The gradient field noise and imbalance of our homemade gradiometer were measured to be 100 fT/m/rt(Hz) and 2E-4 in the lab. In flight, the motion-induced peak-to-peak output of the gradiometer was reduced from 170 nT/m to about 0.1 nT/m, so that a magnetic anomaly signal of about 2 nT/m from a cargo ship was clearly recognized.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (8) , 1-5
Noise Compensation of a Mobile LTS SQUID Planar Gradiometer for Aeromagnetic Detection
A SQUID planar gradiometer is an extremely sensitive sensor for magnetic gradient measurements. It has been shown to have potential applications for aeromagnetic detection. The major challenge when operating an aeromagnetic SQUID system in actual environment is the motion noise, including the inherent response resulting from gradiometer imbalance and from magnetic interferences. Three orthogonal reference magnetometers are usually adopted to improve the gradiometer balance. However, magnetic interference coming from the system itself also needs to be compensated. In this paper, a mathematical model of the motion noise picked up by the gradiometer is derived from the traditional magnetic total field compensation method. Based on the model, the signals from the triaxial magnetometer can also be used to compensate the eddy current contribution to the magnetic interference. To verify the compensation method, a SQUID planar gradiometer system was set up and used for flight trials. The gradient field noise and imbalance of our homemade gradiometer were measured to be 100 fT/m/rt(Hz) and 2E-4 in the lab. In flight, the motion-induced peak-to-peak output of the gradiometer was reduced from 170 nT/m to about 0.1 nT/m, so that a magnetic anomaly signal of about 2 nT/m from a cargo ship was clearly recognized.
- 18 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (8) , 1-4
High-Performance Dual-Channel Squid-Based TEM System and Its Application
Transient Electromagnetic Method (TEM) is an effective way for mineral resource prospecting if an induction coil is used as the traditional sensor. Superconducting Quantum Inter-ference Device (SQUID) obtains excellent sensitivity at low fre-quency compared to coil. Thus the exploration depth and accura-cy of TEM can be greatly improved. However, ultra high slew rate (>10mT/s) is needed for transient primary field recording, which is a great challenge for a single high-sensitivity SQUID re-ceiver. In this paper, two SQUIDs with different sensitivities (1.5nT/ $\Phi_0$ & 99nT/ $\Phi_0$ ) are employed to record the whole TEM decaying signal. The high-sensitivity SQUID (1.5nT/ $\Phi_0$ ) is in reset status when transmitting and becomes locked after tens of μs af-ter transmitting has been cut off. The low-sensitivity SQUID (99 nT/ $\Phi_0$ ) remains locked during the whole procedure with high slew rate (~198mT/s) to record the fast-switching transmitting field. The two channel SQUID outputs are combined together to form a complete decaying curve. A field test was carried out. The decaying curve with noise level of 100fT@DC-25kHz and a fast-switching field of ~630nT cutting off in tens of μs (slew rate up to ~56mT/s) was recorded after stacking. This dual-channel SQUID based TEM system obtains high stability, which is useful for small transmitting loop (<50m) configuration.- 18 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (8) , 1-4
High-Performance Dual-Channel Squid-Based TEM System and Its Application
Transient Electromagnetic Method (TEM) is an effective way for mineral resource prospecting if an induction coil is used as the traditional sensor. Superconducting Quantum Inter-ference Device (SQUID) obtains excellent sensitivity at low fre-quency compared to coil. Thus the exploration depth and accura-cy of TEM can be greatly improved. However, ultra high slew rate (>10mT/s) is needed for transient primary field recording, which is a great challenge for a single high-sensitivity SQUID re-ceiver. In this paper, two SQUIDs with different sensitivities (1.5nT/ $\Phi_0$ & 99nT/ $\Phi_0$ ) are employed to record the whole TEM decaying signal. The high-sensitivity SQUID (1.5nT/ $\Phi_0$ ) is in reset status when transmitting and becomes locked after tens of μs af-ter transmitting has been cut off. The low-sensitivity SQUID (99 nT/ $\Phi_0$ ) remains locked during the whole procedure with high slew rate (~198mT/s) to record the fast-switching transmitting field. The two channel SQUID outputs are combined together to form a complete decaying curve. A field test was carried out. The decaying curve with noise level of 100fT@DC-25kHz and a fast-switching field of ~630nT cutting off in tens of μs (slew rate up to ~56mT/s) was recorded after stacking. This dual-channel SQUID based TEM system obtains high stability, which is useful for small transmitting loop (<50m) configuration.- 1 March 2018
- Published by Society of Exploration Geophysicists in Geophysics
- Vol. 83 (2) , E111-E116
Study of transient electromagnetic method measurements using a superconducting quantum interference device as B sensor receiver in polarizable survey area
Time-domain transient electromagnetic method (TEM) measurements sometimes exhibit a sign reversal in the secondary field during the off-time, which is usually attributed to the induced-polarization (IP) effect. In contrast with the conventional IP method, which uses a current source, TEM with an ungrounded transmitting loop operates using a pure voltage source, which is induced by the primary field switching on and off. We performed TEM measurements in a resistive survey area showing an IP effect, and we used a low-temperature superconducting quantum interference device (LT-SQUID) with sensitivity of [ ] as a magnetic field sensor. A sign reversal in all of our measurements was observed; furthermore, the negative amplitude reached [ ]. In-depth analysis with an extended version of a wire-filament circuit reveals that the large negative signal may be due to discharging of in-ground capacitance, an IP effect. The conduction response of the ground can be restored by subtracting the fitted discharging response (negative valued) from the observed data. To verify this operation, we compared TEM measurements with and without wire-loop targets, which can induce a conduction field with a known decay time constant during the off-time. The extracted conduction responses of the wire-loop targets match the expected ones well. This research reveals that the primary field switch-off must always be included when interpreting TEM data with sign reversal and an LT-SQUID may be a good alternative sensor for studying the IP effect in TEM.
- 1 March 2018
- Published by Society of Exploration Geophysicists in Geophysics
- Vol. 83 (2) , E111-E116
Study of transient electromagnetic method measurements using a superconducting quantum interference device as B sensor receiver in polarizable survey area
Time-domain transient electromagnetic method (TEM) measurements sometimes exhibit a sign reversal in the secondary field during the off-time, which is usually attributed to the induced-polarization (IP) effect. In contrast with the conventional IP method, which uses a current source, TEM with an ungrounded transmitting loop operates using a pure voltage source, which is induced by the primary field switching on and off. We performed TEM measurements in a resistive survey area showing an IP effect, and we used a low-temperature superconducting quantum interference device (LT-SQUID) with sensitivity of [ ] as a magnetic field sensor. A sign reversal in all of our measurements was observed; furthermore, the negative amplitude reached [ ]. In-depth analysis with an extended version of a wire-filament circuit reveals that the large negative signal may be due to discharging of in-ground capacitance, an IP effect. The conduction response of the ground can be restored by subtracting the fitted discharging response (negative valued) from the observed data. To verify this operation, we compared TEM measurements with and without wire-loop targets, which can induce a conduction field with a known decay time constant during the off-time. The extracted conduction responses of the wire-loop targets match the expected ones well. This research reveals that the primary field switch-off must always be included when interpreting TEM data with sign reversal and an LT-SQUID may be a good alternative sensor for studying the IP effect in TEM.