MRMarc Ross

Marc Ross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marc Ross has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Plasma cleaning of the SLAC Linac Coherent Light Source II high energy verification cryomodule cavities

    by B. Giaccone, P. Berrutti, M. Martinello, S. Posen, A. Cravatta, A. Netepenko, T. Arkan, A. Grassellino, B. Hartsell, J. Kaluzny, et al.

    Plasma cleaning is a technique that can be applied in superconducting radio-frequency cavities in situ in cryomodules to decrease their level of field emission (FE). We developed the technique for Linac Coherent Light Source II (LCLS-II) cavities and we present in this paper the full development and application of plasma processing to the LCLS-II High Energy verification cryomodule (vCM). We validated our plasma processing procedure on the vCM, fully processing four out of eight cavities of this CM, demonstrating that cavity performance was preserved in terms of both accelerating field and quality factor. Applying plasma processing to this clean, record breaking cryomodule also showed that no contaminants were introduced in the string, maintaining the vCM FE-free up to the maximum field reached by each cavity. We also found that plasma processing eliminates multipacting (MP)-induced quenches that are frequently observed within the MP band field range. This suggests that plasma processing could be employed in situ in CMs to mitigate both FE and MP, significantly decreasing the testing time of cryomodules, the linac commissioning time and cost, and increasing the accelerator reliability.


  • Open Access

    Field emission mitigation studies in the SLAC Linac Coherent Light Source II superconducting rf cavities via in situ plasma processing

    by Bianca Giaccone, Martina Martinello, Paolo Berrutti, Oleksandr Melnychuk, Dmitri A. Sergatskov, Anna Grassellino, Dan Gonnella, Marc Ross, Marc Doleans, John F. Zasadzinski

    Field emission is one of the main factors that can limit the performance of superconducting radio frequency cavities. To reduce possible field emission in the Linac Coherent Light Source II (LCLS-II), we are developing plasma processing for 1.3 GHz nine-cell cavities. The ultimate goal of plasma processing will be to apply the technique in situ in the cryomodules in order to mitigate hydrocarbon-related field emission without disassembling them. Herein is presented the first systematic study of plasma processing applied to LCLS-II superconducting radio frequency cavities. Having developed a new method of plasma ignition for LCLS-II cavities, we applied plasma processing to 1.3 GHz cavities starting with a clean nitrogen doped cavity and proceeding with studying natural field emission and artificially contaminated cavities. All the cavities were cold tested before and after plasma cleaning in order to compare their performances. It was proved that this technique successfully removes carbon-based contamination from the cavity iris and that it is able to eliminate field emission in a naturally field emitting cavity. The effect of plasma processing on cavities exposed to vacuum failures was also investigated, showing positive results in some cases. This work shows how successful plasma processing is in removing hydrocarbon related contamination from the cavity surface without affecting the high Q-factors and quench fields characteristic of nitrogen doped cavities.


  • Open Access

    Design and Principles of Linear Accelerators and Colliders

    by J. Seeman, D. Schulte, J. P. Delahaye, M. Ross, S. Stapnes, A. Grudiev, A. Yamamoto, A. Latina, A. Seryi, R. Tomás García, et al.

    Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.


  • Open Access

    Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

    by P. Berrutti, B. Giaccone, M. Martinello, A. Grassellino, T. Khabiboulline, M. Doleans, S. Kim, D. Gonnella, G. Lanza, M. Ross

    Superconducting radio frequency cavities performance preservation is crucial, from vertical test to accelerator operation. Field emission is still one of the performance limiting factors to overcome, and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters (hydrocarbon contaminants) and increasing the work function of Nb. The cleaning for Linac Coherent Light Source-II will follow the same plasma composition adopted at SNS, which allows in situ processing of cavities installed in cryomodules. A novel method for plasma ignition has been developed at the Fermi National Accelerator Laboratory: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler. The plasma can be easily ignited and tuned in each of the cavity cells using low radio frequency (RF) power, from 100 W to as low as 2 W depending on the gas and pressure. A method for RF plasma detection has been developed: the plasma location is identified within the cavity without the need of cameras. The presented method can be applied to other multicell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.


  • Open Access

    The International Linear Collider Technical Design Report - Volume 3.I: Accelerator R&D in the Technical Design Phase

    by Chris Adolphsen, Maura Barone, Barry Barish, Karsten Buesser, Philip Burrows, John Carwardine, Jeffrey Clark, Hélène Mainaud Durand, Gerry Dugan, Eckhard Elsen, et al.


  • Open Access

    The International Linear Collider Technical Design Report - Volume 3.II: Accelerator Baseline Design

    by Chris Adolphsen, Maura Barone, Barry Barish, Karsten Buesser, Philip Burrows, John Carwardine, Jeffrey Clark, Hélène Mainaud Durand, Gerry Dugan, Eckhard Elsen, et al.


  • Open Access

    Cavity beam position monitor system for the Accelerator Test Facility 2

    by Y. I. Kim, R. Ainsworth, A. Aryshev, S. T. Boogert, G. Boorman, J. Frisch, A. Heo, Y. Honda, W. H. Hwang, J. Y. Huang, et al.

    The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1  μm for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.


  • Open Access

    International Linear Collider (ILC): A Technical Progress Report

    by Eckhard Elsen, Mike Harrison, Leah Hesla, Marc Ross, Perrine Royole-Degieux, Rika Takahashi, Nicholas Walker, Barbara Warmbein, Akira Yamamoto, Kaoru Yokoya, et al.

    The U.S. Department of Energy's Office of Scientific and Technical Information


  • Open Access

    Energy-zcorrelation measurements of electron bunches

    by Stephen Molloy, Paul Emma, Josef Frisch, Rick Iverson, Marc Ross, Doug McCormick, Mike Woods, Sean Walston

    Bunch length and energy-z correlation measurements were performed on the high energy (28.5~GeV) electron test beam of the A-line and End Station A (ESA) facilities at the SLAC National Accelerator Laboratory. The longitudinal profile of each bunch was measured by imaging the synchrotron light emitted as the electrons traversed a highly dispersive bend after being streaked by a transverse rf deflecting cavity. In addition, high frequency diodes and pyroelectric detectors placed at a ceramic gap in the beam line were used to measure the length of the bunch in ESA.

  • Open Access

    Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

    by D. Reschke, R. Bandelmann, T. Buettner, K. Escherich, A. Goessel, B. V.D.Horst, J. Iversen, D. Klinke, G. Kreps, N. Krupka, et al.

    The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY). The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.