Julia Scherschligt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Julia Scherschligt has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Daniel S. Barker
National Institute of Standards and Technology
13 shared publications - Stephen Eckel
National Institute of Standards and Technology
13 shared publications - James A. Fedchak
Sensor Science Division, National Institute of Standards and Technology 1 , Gaithersburg, Maryland 20899, USA
12 shared publications - Eite Tiesinga
Joint Quantum Institute
5 shared publications - Eric B. Norrgard
National Institute of Standards and Technology
4 shared publications Katie Schlatter
National Institute of Standards and Technology, Gaithersburg, Maryland, USA
3 shared publications
Latest Publications
- 17 April 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (4) , 044037
Compact blackbody-radiation atomic sensor: Measuring temperature using optically excited atoms in vapor cells
We demonstrate a blackbody-radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a precision of 0.04% in the range 308--344 K when averaging for several seconds. Additionally, we describe an extension to this measurement scheme where the device operates as a self-calibrated, or primary, thermometer. We make progress toward realizing a primary thermometer by demonstrating a temperature-dependent self-consistent calibration scheme, with temperature accuracy of the order of 1% limited by the uncertainty in atomic transition dipole matrix elements.
- 17 April 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 23 (4) , 044037
Compact blackbody-radiation atomic sensor: Measuring temperature using optically excited atoms in vapor cells
We demonstrate a blackbody-radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a precision of 0.04% in the range 308--344 K when averaging for several seconds. Additionally, we describe an extension to this measurement scheme where the device operates as a self-calibrated, or primary, thermometer. We make progress toward realizing a primary thermometer by demonstrating a temperature-dependent self-consistent calibration scheme, with temperature accuracy of the order of 1% limited by the uncertainty in atomic transition dipole matrix elements.
- 12 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Effect of glancing collisions in the cold-atom vacuum standard
We theoretically investigate the effect of "glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold 7Li or 87Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard-a combined flowmeter and dynamic expansion system-to the CAVS [D.S. Barker, et al., AVS Quantum Science 5 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for 7Li colliding with noble gases or N2 by up to 0.6 %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for 87Rb colliding with noble gases or N2 shift by as much as 2.2 %.
- 12 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Effect of glancing collisions in the cold-atom vacuum standard
We theoretically investigate the effect of "glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold 7Li or 87Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard-a combined flowmeter and dynamic expansion system-to the CAVS [D.S. Barker, et al., AVS Quantum Science 5 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for 7Li colliding with noble gases or N2 by up to 0.6 %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for 87Rb colliding with noble gases or N2 shift by as much as 2.2 %.
- Open Access
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 049501
Corrigendum: Corrections to a proposal for three categories of units within the SI (2024 Metrologia 61 033001)
In this corrigendum, we correct several typographical or typesetting errors and small but meaningful errors in tables 1, A.1 and A.3 found in the original manuscript. We emphasize as a correction that the Avogadro constant is not a dimensionless number. The corrections are placed according to the original organization: section 2, references, and appendix.
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 049501
Open AccessCorrigendum: Corrections to a proposal for three categories of units within the SI (2024 Metrologia 61 033001)
In this corrigendum, we correct several typographical or typesetting errors and small but meaningful errors in tables 1, A.1 and A.3 found in the original manuscript. We emphasize as a correction that the Avogadro constant is not a dimensionless number. The corrections are placed according to the original organization: section 2, references, and appendix.
- Open Access
- 29 April 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 033001
A proposal for three categories of units within the SI
In this letter we examine the organization of the traditional base units and defining constants established in the 2019 redefinition of the international system of units (SI). For the next redefinition of the SI, which will accompany the anticipated redefinition of the second, we propose an organizational change to improve clarity while maintaining practicality. We propose three distinct categories of units: The first category comprises the four base-measurement units: The second, meter, kilogram, and ampere. The second contains physiologically-relevant derived units. The third category contains the remaining units derived from the base units.
- 29 April 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 033001
Open AccessA proposal for three categories of units within the SI
In this letter we examine the organization of the traditional base units and defining constants established in the 2019 redefinition of the international system of units (SI). For the next redefinition of the SI, which will accompany the anticipated redefinition of the second, we propose an organizational change to improve clarity while maintaining practicality. We propose three distinct categories of units: The first category comprises the four base-measurement units: The second, meter, kilogram, and ampere. The second contains physiologically-relevant derived units. The third category contains the remaining units derived from the base units.
- Open Access
- 1 August 2023
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 5 (3)
Accurate measurement of the loss rate of cold atoms due to background gas collisions for the quantum-based cold atom vacuum standard
We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.
- 1 August 2023
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 5 (3)
Open AccessAccurate measurement of the loss rate of cold atoms due to background gas collisions for the quantum-based cold atom vacuum standard
We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.
- Open Access
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 121101
Precise quantum measurement of vacuum with cold atoms
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard–Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
- 1 December 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (12) , 121101
Open AccessPrecise quantum measurement of vacuum with cold atoms
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard–Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
- 1 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 045014
A constant pressure flowmeter for extreme-high vacuum
We demonstrate operation of a constant-pressure flowmeter capable of generating and accurately measuring flows as low as 2 × 10−13 mol s−1. Generation of such small flows is accomplished by using a small conductance element with C ≈ 50 nl s−1. Accurate measurement then requires both low outgassing materials ( < 1 × 1 0 − 15 mol s−1) and small volume changes ( ≈ 70 μl). We outline the present flowmeter’s construction, detail its operation, and quantify its uncertainty. The type-B uncertainty is < 0.2 % (k = 1) over the entire operating range. In particular, we present an analysis of its hydraulic system, and quantify the shift and uncertainty due to the slightly compressible oil. Finally, we compare our flowmeter against a NIST standard flowmeter, and find agreement to within 0.5% (k = 2).
- 1 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 045014
A constant pressure flowmeter for extreme-high vacuum
We demonstrate operation of a constant-pressure flowmeter capable of generating and accurately measuring flows as low as 2 × 10−13 mol s−1. Generation of such small flows is accomplished by using a small conductance element with C ≈ 50 nl s−1. Accurate measurement then requires both low outgassing materials ( < 1 × 1 0 − 15 mol s−1) and small volume changes ( ≈ 70 μl). We outline the present flowmeter’s construction, detail its operation, and quantify its uncertainty. The type-B uncertainty is < 0.2 % (k = 1) over the entire operating range. In particular, we present an analysis of its hydraulic system, and quantify the shift and uncertainty due to the slightly compressible oil. Finally, we compare our flowmeter against a NIST standard flowmeter, and find agreement to within 0.5% (k = 2).
- 15 July 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034403
Comparison of two multiplexed portable cold-atom vacuum standards
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.
- 15 July 2022
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 4 (3) , 034403
Comparison of two multiplexed portable cold-atom vacuum standards
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.
- 25 May 2022
- Published by Morressier GmbH
Validation of the cold atom vacuum standard
Validation of the cold atom vacuum standard |
- 25 May 2022
- Published by Morressier GmbH
Validation of the cold atom vacuum standard
Validation of the cold atom vacuum standard |