Markus Kopp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Markus Kopp has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Stefan May
Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg and Uniklinikum Erlangen, Erlangen, Germany
12 shared publications - Michael Uder
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
12 shared publications - Marco Wiesmueller
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
7 shared publications - Rafael Heiss
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg, Erlangen, Germany
7 shared publications - Martin Georg Zeilinger
Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
4 shared publications - Wolfgang Wuest
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
4 shared publications
Latest Publications
- 16 November 2026
- Published by Wolters Kluwer Health in Investigative Radiology
Photon-Counting CT for Postoperative Imaging of Cochlear Implants
Objectives: After FDA approval in 2021, photon-counting detector computed tomography (PCCT) has demonstrated its feasibility for high-resolution imaging while lowering the radiation dose at the same time. High-resolution visualization of cochlear implant (CI) integrity and positioning is crucial for postoperative management. The aim of this study was to evaluate the performance of PCCT for postoperative imaging after CI implantation in comparison to high-resolution flat-detector CT (FDCT), the current clinical gold standard. Materials and Methods: Postoperative PCCT scans after cochlear implantation were retrospectively analyzed from August 2024 to April 2026. Scans were included for analysis if FDCT acquisition had been before PCCT on the same patient in the course of sequential bilateral cochlear implantation. Image quality was assessed in consensus by 2 experienced readers using a scoring system analyzing structural delineation of the inner and middle ear, CI integrity, metal and motion artifacts as well as calculating an overall score. Radiation dose was retrieved from the picture archiving and communication system. Results: Twenty-eight postoperative PCCT scans of patients after CI implantation with a mean time delay of 4.5±5.1 years between FDCT and PCCT scans were evaluated. Image quality of PCCT was noninferior to FDCT for all single imaging features ( P P P =0.999). PCCT was superior to FDCT in reducing metal and motion artifacts and increasing the delineation of the stapes ( P =0.009 to P P <0.001) applying our institutional protocols. Conclusions: Regarding image quality in postoperative assessment of CI, PCCT is noninferior to or in single features better than FDCT at a significantly lower radiation dose and shorter scan time.
- 16 November 2026
- Published by Wolters Kluwer Health in Investigative Radiology
Photon-Counting CT for Postoperative Imaging of Cochlear Implants
Objectives: After FDA approval in 2021, photon-counting detector computed tomography (PCCT) has demonstrated its feasibility for high-resolution imaging while lowering the radiation dose at the same time. High-resolution visualization of cochlear implant (CI) integrity and positioning is crucial for postoperative management. The aim of this study was to evaluate the performance of PCCT for postoperative imaging after CI implantation in comparison to high-resolution flat-detector CT (FDCT), the current clinical gold standard. Materials and Methods: Postoperative PCCT scans after cochlear implantation were retrospectively analyzed from August 2024 to April 2026. Scans were included for analysis if FDCT acquisition had been before PCCT on the same patient in the course of sequential bilateral cochlear implantation. Image quality was assessed in consensus by 2 experienced readers using a scoring system analyzing structural delineation of the inner and middle ear, CI integrity, metal and motion artifacts as well as calculating an overall score. Radiation dose was retrieved from the picture archiving and communication system. Results: Twenty-eight postoperative PCCT scans of patients after CI implantation with a mean time delay of 4.5±5.1 years between FDCT and PCCT scans were evaluated. Image quality of PCCT was noninferior to FDCT for all single imaging features ( P P P =0.999). PCCT was superior to FDCT in reducing metal and motion artifacts and increasing the delineation of the stapes ( P =0.009 to P P <0.001) applying our institutional protocols. Conclusions: Regarding image quality in postoperative assessment of CI, PCCT is noninferior to or in single features better than FDCT at a significantly lower radiation dose and shorter scan time.
- Open Access
- 21 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5698
Advanced Visualization of Peroneal Artery Perforators Prior to Autologous Transplantation in Head and Neck Surgery by Dual-Energy CTA and Semiautomatic Vessel Unfolding
Background/Objectives: Accurate visualization of peroneal perforator vessels prior to autologous transplantation of osteomyocutaneous fibular flap is essential for surgical success. Our aim was to improve and simplify pre-surgical diagnostics of peroneal perforators using a dedicated dual-energy Computed Tomography Angiography (CTA) protocol and semiautomatic Vessel Unfolding Reconstruction algorithm (VUR). Methods: CTA of both lower legs was performed in 22 patients using dual-energy acquisitions from a third-generation dual-source CT scanner and a high iodine flux (7 mL/s, 350 mg/mL). Low-energy virtual monoenergetic reconstructions (40 keV) were automatically reconstructed from the scanner and used for centerline labeling of the peroneal arteries and their perforators on a post-processing console using a dedicated vascular workflow. Separate segmentation and curved multiplanar reconstructions (MPRs) of each identified peroneal perforator vessel were regarded as the gold standard. Traditional visualization techniques of the entire volume like thin-slice maximum intensity projections (MIPs) or the volume rendering technique (VRT) were compared to a new VUR algorithm that aimed to adjust the visualization plane to the course of the vessels. The identified numbers and lengths of the perforator arteries were compared between curved MPRs, thin-slice MIPs in oblique coronal orientation, posterior-view VRT and coronal VUR of each lower leg. Results: The VUR algorithm was feasible in all patients and the same quantity of peroneal perforator vessels could be detected in comparison to the gold standard. The mean number of perforator vessels per lower leg was 2.6. Mean perforator length in VUR was slightly shorter by 1.6% and did not significantly differ from curved MPRs (p = 0.54), whereas length values from oblique coronal MIP and VRT reconstructions were significantly shorter (both p < 0.001). Conclusions: The combination of virtual monoenergetic reconstructions and the VUR algorithm enables comprehensive and precise depiction of small peroneal perforator vessels prior to autologous fibular flap transplantation, representing a diagnostic tool comparable to traditional visualization methods.
- 21 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5698
Open AccessAdvanced Visualization of Peroneal Artery Perforators Prior to Autologous Transplantation in Head and Neck Surgery by Dual-Energy CTA and Semiautomatic Vessel Unfolding
Background/Objectives: Accurate visualization of peroneal perforator vessels prior to autologous transplantation of osteomyocutaneous fibular flap is essential for surgical success. Our aim was to improve and simplify pre-surgical diagnostics of peroneal perforators using a dedicated dual-energy Computed Tomography Angiography (CTA) protocol and semiautomatic Vessel Unfolding Reconstruction algorithm (VUR). Methods: CTA of both lower legs was performed in 22 patients using dual-energy acquisitions from a third-generation dual-source CT scanner and a high iodine flux (7 mL/s, 350 mg/mL). Low-energy virtual monoenergetic reconstructions (40 keV) were automatically reconstructed from the scanner and used for centerline labeling of the peroneal arteries and their perforators on a post-processing console using a dedicated vascular workflow. Separate segmentation and curved multiplanar reconstructions (MPRs) of each identified peroneal perforator vessel were regarded as the gold standard. Traditional visualization techniques of the entire volume like thin-slice maximum intensity projections (MIPs) or the volume rendering technique (VRT) were compared to a new VUR algorithm that aimed to adjust the visualization plane to the course of the vessels. The identified numbers and lengths of the perforator arteries were compared between curved MPRs, thin-slice MIPs in oblique coronal orientation, posterior-view VRT and coronal VUR of each lower leg. Results: The VUR algorithm was feasible in all patients and the same quantity of peroneal perforator vessels could be detected in comparison to the gold standard. The mean number of perforator vessels per lower leg was 2.6. Mean perforator length in VUR was slightly shorter by 1.6% and did not significantly differ from curved MPRs (p = 0.54), whereas length values from oblique coronal MIP and VRT reconstructions were significantly shorter (both p < 0.001). Conclusions: The combination of virtual monoenergetic reconstructions and the VUR algorithm enables comprehensive and precise depiction of small peroneal perforator vessels prior to autologous fibular flap transplantation, representing a diagnostic tool comparable to traditional visualization methods.
- Open Access
- 19 September 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3565-3574
Deep learning-based acceleration and denoising of 0.55T MRI for enhanced conspicuity of vestibular Schwannoma post contrast administration
Background and purpose: Deep-learning (DL) based MRI denoising techniques promise improved image quality and shorter examination times. This advancement is particularly beneficial for 0.55T MRI, where the inherently lower signal-to-noise (SNR) ratio can compromise image quality. Sufficient SNR is crucial for the reliable detection of vestibular schwannoma (VS). The objective of this study is to evaluate the VS conspicuity and acquisition time (TA) of 0.55T MRI examinations with contrast agents using a DL-denoising algorithm. Materials and methods: From January 2024 to October 2024, we retrospectively included 30 patients with VS (9 women). We acquired a clinical reference protocol of the cerebellopontine angle containing a T1w fat-saturated (fs) axial (number of signal averages [NSA] 4) and a T1w Spectral Attenuated Inversion Recovery (SPAIR) coronal (NSA 2) sequence after contrast agent (CA) application without advanced DL-based denoising (w/o DL). We reconstructed the T1w fs CA sequence axial and the T1w SPAIR CA coronal with full DL-denoising mode without change of NSA, and secondly with 1 NSA for T1w fs CA axial and T1w SPAIR coronal (DL&1NSA). Each sequence was rated on a 5-point Likert scale (1: insufficient, 3: moderate, clinically sufficient; 5: perfect) for: overall image quality; VS conspicuity, and artifacts. Secondly, we analyzed the reliability of the size measurements. Two radiologists specializing in head and neck imaging performed the reading and measurements. The Wilcoxon Signed-Rank Test was used for non-parametric statistical comparison. Results: The DL&4NSA axial/coronal study sequence achieved the highest overall IQ (median 4.9). The image quality (IQ) for DL&1NSA was higher (M: 4.0) than for the reference sequence (w/o DL; median 4.0 versus 3.5, each p < 0.01). Similarly, the VS conspicuity was best for DL&4NSA (M: 4.9), decreased for DL&1NSA (M: 4.1), and was lower but still sufficient for w/o DL (M: 3.7, each p < 0.01). The TA for the axial and coronal post-contrast sequences was 8:59 minutes for DL&4NSA and w/o DL and decreased to 3:24 minutes with DL&1NSA. Conclusions: This study underlines that advanced DL-based denoising techniques can reduce the examination time by more than half while simultaneously improving image quality.
- 19 September 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (12) , 3565-3574
Open AccessDeep learning-based acceleration and denoising of 0.55T MRI for enhanced conspicuity of vestibular Schwannoma post contrast administration
Background and purpose: Deep-learning (DL) based MRI denoising techniques promise improved image quality and shorter examination times. This advancement is particularly beneficial for 0.55T MRI, where the inherently lower signal-to-noise (SNR) ratio can compromise image quality. Sufficient SNR is crucial for the reliable detection of vestibular schwannoma (VS). The objective of this study is to evaluate the VS conspicuity and acquisition time (TA) of 0.55T MRI examinations with contrast agents using a DL-denoising algorithm. Materials and methods: From January 2024 to October 2024, we retrospectively included 30 patients with VS (9 women). We acquired a clinical reference protocol of the cerebellopontine angle containing a T1w fat-saturated (fs) axial (number of signal averages [NSA] 4) and a T1w Spectral Attenuated Inversion Recovery (SPAIR) coronal (NSA 2) sequence after contrast agent (CA) application without advanced DL-based denoising (w/o DL). We reconstructed the T1w fs CA sequence axial and the T1w SPAIR CA coronal with full DL-denoising mode without change of NSA, and secondly with 1 NSA for T1w fs CA axial and T1w SPAIR coronal (DL&1NSA). Each sequence was rated on a 5-point Likert scale (1: insufficient, 3: moderate, clinically sufficient; 5: perfect) for: overall image quality; VS conspicuity, and artifacts. Secondly, we analyzed the reliability of the size measurements. Two radiologists specializing in head and neck imaging performed the reading and measurements. The Wilcoxon Signed-Rank Test was used for non-parametric statistical comparison. Results: The DL&4NSA axial/coronal study sequence achieved the highest overall IQ (median 4.9). The image quality (IQ) for DL&1NSA was higher (M: 4.0) than for the reference sequence (w/o DL; median 4.0 versus 3.5, each p < 0.01). Similarly, the VS conspicuity was best for DL&4NSA (M: 4.9), decreased for DL&1NSA (M: 4.1), and was lower but still sufficient for w/o DL (M: 3.7, each p < 0.01). The TA for the axial and coronal post-contrast sequences was 8:59 minutes for DL&4NSA and w/o DL and decreased to 3:24 minutes with DL&1NSA. Conclusions: This study underlines that advanced DL-based denoising techniques can reduce the examination time by more than half while simultaneously improving image quality.
- Open Access
- 23 October 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (5) , 299-310
Low-Field MRI for Dental Imaging in Pediatric Patients With Supernumerary and Ectopic Teeth
Objectives: This study sought to elucidate the diagnostic performance of 0.55 T magnetic resonance imaging (MRI) for pediatric dental imaging, specifically in terms of the image quality (IQ) for detecting ectopic and/or supernumerary teeth, compared with routine ultra-low-dose computed tomography (ULD-CT) of the jaw. Materials and Methods: A total of 16 pediatric patients (mean age: 12.4 ± 2.6 years, range: 9–17 years) with ectopic and/or supernumerary teeth screened from January 2023 to January 2024 were enrolled in this prospective, single-center study. All patients underwent ULD-CT as the clinical reference standard and 0.55 T MRI as the study scan on the same day. A 0.6-mm isotropic 3-dimensional T1w FLASH sequence was developed with a dedicated field of view of the upper and lower jaws. ULD-CT was performed using a new single-source computed tomography (CT) scanner equipped with a tin filter (Sn100, slice thickness: 1 mm, quality reference mAs: 24). The IQ for the tooth axis, the tooth length, the tooth root, root resorptions, cysts, the periodontal ligament space, and the mandibular canal was evaluated twice by 3 senior readers using a 5-point Likert scale (LS) (LS score of 1: insufficient, 3: reduced IQ but sufficient for clinical use, and 5: perfect) and compared between both methods. Subsequently, the results were dichotomized into nonvalid (LS score of ≤2) and valid (LS score of ≥3) for clinical use. Results: A total of 49 ectopic and/or supernumerary teeth in 16 pediatric patients were investigated using ULD-CT (CTDI: 0.43 ± 0.09 mGy) and 0.55 T MRI. The mean MRI acquisition time was 9:45 minutes. Motion artifacts were nonsignificantly different between 0.55 T MRI and ULD-CT (P = 0.126). The IQ for the tooth axis, the tooth root, root resorptions, and cysts was similar between the methods. The IQ for the periodontal ligament space and tooth length favored ULD-CT by 14% (confidence interval [CI]: 4.3%–24%) and 7.5% (CI: 1.8%–13%), respectively, whereas that for the mandibular canal favored 0.55 T MRI by −35% (CI: −54%–16%). Sufficient IQ was found especially for cystic lesions (CT: 100% sufficient, MRI: 95% sufficient), the tooth root (CT: 100%, MRI: 98%), root resorptions (CT: 94%; MRI: 85%), the tooth axis (CT: 100%; MRI: 98%), and the tooth length (CT: 99%; MRI: 91%). Conclusions: The findings indicate that 0.55 T MRI is a feasible, radiation-free technique for delineating ectopic and/or supernumerary teeth in pediatric patients. Nevertheless, to date, 0.55 T MRI has not yet been able to provide an optimal IQ for all anatomical tooth and jaw structures. In cases of advanced clinical indications that require optimal spatial resolution, high-resolution CT or cone-beam CT may still be necessary.
- 23 October 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (5) , 299-310
Open AccessLow-Field MRI for Dental Imaging in Pediatric Patients With Supernumerary and Ectopic Teeth
Objectives: This study sought to elucidate the diagnostic performance of 0.55 T magnetic resonance imaging (MRI) for pediatric dental imaging, specifically in terms of the image quality (IQ) for detecting ectopic and/or supernumerary teeth, compared with routine ultra-low-dose computed tomography (ULD-CT) of the jaw. Materials and Methods: A total of 16 pediatric patients (mean age: 12.4 ± 2.6 years, range: 9–17 years) with ectopic and/or supernumerary teeth screened from January 2023 to January 2024 were enrolled in this prospective, single-center study. All patients underwent ULD-CT as the clinical reference standard and 0.55 T MRI as the study scan on the same day. A 0.6-mm isotropic 3-dimensional T1w FLASH sequence was developed with a dedicated field of view of the upper and lower jaws. ULD-CT was performed using a new single-source computed tomography (CT) scanner equipped with a tin filter (Sn100, slice thickness: 1 mm, quality reference mAs: 24). The IQ for the tooth axis, the tooth length, the tooth root, root resorptions, cysts, the periodontal ligament space, and the mandibular canal was evaluated twice by 3 senior readers using a 5-point Likert scale (LS) (LS score of 1: insufficient, 3: reduced IQ but sufficient for clinical use, and 5: perfect) and compared between both methods. Subsequently, the results were dichotomized into nonvalid (LS score of ≤2) and valid (LS score of ≥3) for clinical use. Results: A total of 49 ectopic and/or supernumerary teeth in 16 pediatric patients were investigated using ULD-CT (CTDI: 0.43 ± 0.09 mGy) and 0.55 T MRI. The mean MRI acquisition time was 9:45 minutes. Motion artifacts were nonsignificantly different between 0.55 T MRI and ULD-CT (P = 0.126). The IQ for the tooth axis, the tooth root, root resorptions, and cysts was similar between the methods. The IQ for the periodontal ligament space and tooth length favored ULD-CT by 14% (confidence interval [CI]: 4.3%–24%) and 7.5% (CI: 1.8%–13%), respectively, whereas that for the mandibular canal favored 0.55 T MRI by −35% (CI: −54%–16%). Sufficient IQ was found especially for cystic lesions (CT: 100% sufficient, MRI: 95% sufficient), the tooth root (CT: 100%, MRI: 98%), root resorptions (CT: 94%; MRI: 85%), the tooth axis (CT: 100%; MRI: 98%), and the tooth length (CT: 99%; MRI: 91%). Conclusions: The findings indicate that 0.55 T MRI is a feasible, radiation-free technique for delineating ectopic and/or supernumerary teeth in pediatric patients. Nevertheless, to date, 0.55 T MRI has not yet been able to provide an optimal IQ for all anatomical tooth and jaw structures. In cases of advanced clinical indications that require optimal spatial resolution, high-resolution CT or cone-beam CT may still be necessary.
- Open Access
- 1 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (3) , 223-229
MRI of Temporomandibular Joint Disorders: A Comparative Study of 0.55 T and 1.5 T MRI
Objectives: Temporomandibular disorders (TMDs) are common and may cause persistent functional limitations and pain. Magnetic resonance imaging (MRI) at 1.5 and 3 T is commonly applied for the evaluation of the temporomandibular joint (TMJ). No evidence is available regarding the feasibility of modern low-field MRI for the assessment of TMDs. The objective of this prospective study was to evaluate the image quality (IQ) of 0.55 T MRI in direct comparison with 1.5 T MRI. Materials and Methods: Seventeen patients (34 TMJs) with suspected intraarticular TMDs were enrolled, and both 0.55 and 1.5 T MRI were performed on the same day. Two senior readers independently evaluated the IQ focusing on the conspicuity of disc morphology (DM), disc position (DP), and osseous joint morphology (OJM) for each joint. We analyzed the IQ and degree of artifacts using a 4-point Likert scale (LS) at both field strengths. A fully sufficient IQ was defined as an LS score of ≥3. Nonparametric Wilcoxon test for related samples was used for statistical comparison. Results: The median IQ for the DM and OJM at 0.55 T was inferior to that at 1.5 T (DM: 3 [interquartile range {IQR}, 3–4] vs 4 [IQR, 4–4]; OJM: 3 [IQR, 3–4] vs 4 [IQR 4–4]; each P < 0.001). For DP, the IQ was comparable (4 [IQR 3–4] vs 4 [IQR 4–4]; P > 0.05). A sufficient diagnostic IQ was maintained for the DM, DP, and OJM in 92% of the cases at 0.55 T and 100% at 1.5 T. Minor image artifacts (LS score of ≥3) were more prevalent at 0.55 T (29%) than at 1.5 T (12%). Conclusions: Magnetic resonance imaging of the TMJ at 0.55 T yields a lower IQ than does MRI at 1.5 T but maintains sufficient diagnostic confidence in the majority of patients. Further improvements are needed for reliable clinical application.
- 1 March 2024
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 59 (3) , 223-229
Open AccessMRI of Temporomandibular Joint Disorders: A Comparative Study of 0.55 T and 1.5 T MRI
Objectives: Temporomandibular disorders (TMDs) are common and may cause persistent functional limitations and pain. Magnetic resonance imaging (MRI) at 1.5 and 3 T is commonly applied for the evaluation of the temporomandibular joint (TMJ). No evidence is available regarding the feasibility of modern low-field MRI for the assessment of TMDs. The objective of this prospective study was to evaluate the image quality (IQ) of 0.55 T MRI in direct comparison with 1.5 T MRI. Materials and Methods: Seventeen patients (34 TMJs) with suspected intraarticular TMDs were enrolled, and both 0.55 and 1.5 T MRI were performed on the same day. Two senior readers independently evaluated the IQ focusing on the conspicuity of disc morphology (DM), disc position (DP), and osseous joint morphology (OJM) for each joint. We analyzed the IQ and degree of artifacts using a 4-point Likert scale (LS) at both field strengths. A fully sufficient IQ was defined as an LS score of ≥3. Nonparametric Wilcoxon test for related samples was used for statistical comparison. Results: The median IQ for the DM and OJM at 0.55 T was inferior to that at 1.5 T (DM: 3 [interquartile range {IQR}, 3–4] vs 4 [IQR, 4–4]; OJM: 3 [IQR, 3–4] vs 4 [IQR 4–4]; each P < 0.001). For DP, the IQ was comparable (4 [IQR 3–4] vs 4 [IQR 4–4]; P > 0.05). A sufficient diagnostic IQ was maintained for the DM, DP, and OJM in 92% of the cases at 0.55 T and 100% at 1.5 T. Minor image artifacts (LS score of ≥3) were more prevalent at 0.55 T (29%) than at 1.5 T (12%). Conclusions: Magnetic resonance imaging of the TMJ at 0.55 T yields a lower IQ than does MRI at 1.5 T but maintains sufficient diagnostic confidence in the majority of patients. Further improvements are needed for reliable clinical application.
- Open Access
- 28 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1362
Diagnostic Accuracy and Performance Analysis of a Scanner-Integrated Artificial Intelligence Model for the Detection of Intracranial Hemorrhages in a Traumatology Emergency Department
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.
- 28 November 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (12) , 1362
Open AccessDiagnostic Accuracy and Performance Analysis of a Scanner-Integrated Artificial Intelligence Model for the Detection of Intracranial Hemorrhages in a Traumatology Emergency Department
Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.
- Open Access
- 31 August 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 167, 111078
Personalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems – Impact on the acquisition technique, scan range, and reconstruction type
- 31 August 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 167, 111078
Open AccessPersonalization of thoracoabdominal CT examinations using scanner integrated clinical decision support systems – Impact on the acquisition technique, scan range, and reconstruction type
- Open Access
- 11 October 2022
- Published by Springer Nature in Insights into Imaging
- Vol. 13 (1) , 1-13
Digitized and structured informed patient consent before contrast-enhanced computed tomography: feasibility and benefits in clinical routine
Background: To evaluate the feasibility and benefits of digitized informed patient consent (D-IPC) for contrast-enhanced CT and compare digitized documentation with paper-based, conventional patient records (C-PR). Methods: We offered D-IPC to 2016 patients scheduled for a CT. We assessed patient history (e.g., CT examinations, malignant or cardiovascular diseases) and contraindications (red flags) for a CT (e.g., thyroid hyperfunction, allergies) using a tablet device. We evaluated the success rate of D-IPC and compared patient age between the subgroups of patients who were able or unable to complete D-IPC. We analyzed the prevalence of marked questions and red flags (RF). RF were compared with the documentation from C-PR. We estimated greenhouse gas (GHG) emissions for paperless workflow and provide a cost–benefit analysis. Results: Overall, 84.4% of patients completed D-IPC. They were younger (median 61 years) than unsuccessful patients (65 years; p < 0.001). Patients who marked questions (21.7%) were older than patients without inquiries (median 63.9 vs 59.5 years; p < 0.001). The most prevalent RF was thyroid disease (23.8%). RF were considered critical for contrast-agent injection in 13.7%, requiring personalized preparation. The detection rate for RF documented with D-IPC was higher than for C-PR (n = 385 vs. 43). GHG emissions for tablet production are 80–90 times higher than for paper production. The estimated costs were slightly higher for D-IPC (+ 8.7%). Conclusion: D-IPC is feasible, but patient age is a relevant factor. Marked questions and RF help personalize IPC. The availability of patient history by D-IPC was superior compared to C-PR.
- 11 October 2022
- Published by Springer Nature in Insights into Imaging
- Vol. 13 (1) , 1-13
Open AccessDigitized and structured informed patient consent before contrast-enhanced computed tomography: feasibility and benefits in clinical routine
Background: To evaluate the feasibility and benefits of digitized informed patient consent (D-IPC) for contrast-enhanced CT and compare digitized documentation with paper-based, conventional patient records (C-PR). Methods: We offered D-IPC to 2016 patients scheduled for a CT. We assessed patient history (e.g., CT examinations, malignant or cardiovascular diseases) and contraindications (red flags) for a CT (e.g., thyroid hyperfunction, allergies) using a tablet device. We evaluated the success rate of D-IPC and compared patient age between the subgroups of patients who were able or unable to complete D-IPC. We analyzed the prevalence of marked questions and red flags (RF). RF were compared with the documentation from C-PR. We estimated greenhouse gas (GHG) emissions for paperless workflow and provide a cost–benefit analysis. Results: Overall, 84.4% of patients completed D-IPC. They were younger (median 61 years) than unsuccessful patients (65 years; p < 0.001). Patients who marked questions (21.7%) were older than patients without inquiries (median 63.9 vs 59.5 years; p < 0.001). The most prevalent RF was thyroid disease (23.8%). RF were considered critical for contrast-agent injection in 13.7%, requiring personalized preparation. The detection rate for RF documented with D-IPC was higher than for C-PR (n = 385 vs. 43). GHG emissions for tablet production are 80–90 times higher than for paper production. The estimated costs were slightly higher for D-IPC (+ 8.7%). Conclusion: D-IPC is feasible, but patient age is a relevant factor. Marked questions and RF help personalize IPC. The availability of patient history by D-IPC was superior compared to C-PR.
- Open Access
- 1 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1860
Apparent Diffusion Coefficient (ADC) Histogram Analysis in Parotid Gland Tumors: Evaluating a Novel Approach for Differentiation between Benign and Malignant Parotid Lesions Based on Full Histogram Distributions
The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions (“leave-one-out CV” accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.
- 1 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (8) , 1860
Open AccessApparent Diffusion Coefficient (ADC) Histogram Analysis in Parotid Gland Tumors: Evaluating a Novel Approach for Differentiation between Benign and Malignant Parotid Lesions Based on Full Histogram Distributions
The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions (“leave-one-out CV” accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.