Erick Osvaldo Martínez-Ruiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erick Osvaldo Martínez-Ruiz has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Alejandra Ortiz-Dosal
Facultad de Ciencias, Universidad Autónoma de San Luis Potosí, Av. Parque Chapultepec 1570, San Luis Potosí 78295, México
6 shared publications - Adán Reyes-Reyes
Facultad de Ciencias, Universidad Autónoma de San Luis Potosí, Av. Parque Chapultepec 1570, San Luis Potosí 78295, México
5 shared publications - Eleazar Samuel Kolosovas-Machuca
Universidad Autónoma de San Luis Potosí
5 shared publications - Maria del Carmen Rodríguez-Aranda
Coordinación para la Innovación y Aplicación de la Ciencia y la Tecnología (CIACyT), Universidad Autónoma de San Luis Potosí, Av. Sierra Leona 550, San Luis Potosí 78210, Mexico
5 shared publications - María Guadalupe Neira-Velázquez
Centro de Investigación en Química Aplicada Saltillo Coahuila México
4 shared publications - Emmanuel Rivera-Perez
Facultad de Ciencias Universidad Autónoma de San Luis Potosí San Luis Potosí México
3 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by MDPI AG in Methods and Protocols
- Vol. 9 (5) , 148
Robust Comparison of Raman Spectra Under Various Perturbations: Benchmarking Common Similarity Metrics and a New Peak-Oriented Index
Matching Raman spectra is complicated by shifts in band position, changes in intensity and linewidth, the appearance or loss of bands, and noise because different similarity measures preserve different forms of spectral evidence. We introduce , a peak-oriented index based on one-to-one band assignment and explicit penalties for unmatched peaks, and evaluate it together with pointwise, rigid-alignment, elastic-alignment, and derivative-based measures. The benchmark comprises 500 baseline-corrected reference spectra and 50,000 controlled perturbed queries. Each noisy query was independently converted to a peak table before evaluation. Parameter sensitivity was assessed on 350 calibration references, after which the selected configuration and a single hybrid-ranking weight were fixed for 150 held-out references. The moderate association between and the waveform metrics (–) indicates that band correspondence retains information not captured by waveform agreement alone. In full-library retrieval, standalone attained a held-out Top-1 recovery of 0.9603. Combining with cosine similarity, Pearson correlation, cross-correlation, or cross-cosine similarity using the same calibration-selected weight () increased their respective Top-1 recovery rates from 0.4166 to 0.8828, 0.3960 to 0.9094, 0.9449 to 0.9930, and 0.9523 to 0.9933; reference-level bootstrap intervals for all four changes excluded zero. These results establish as a complementary structural layer that can strengthen both shift-sensitive and shift-tolerant library rankings, rather than as a universal replacement for waveform metrics.- 9 October 2026
- Published by MDPI AG in Methods and Protocols
- Vol. 9 (5) , 148
Open AccessRobust Comparison of Raman Spectra Under Various Perturbations: Benchmarking Common Similarity Metrics and a New Peak-Oriented Index
Matching Raman spectra is complicated by shifts in band position, changes in intensity and linewidth, the appearance or loss of bands, and noise because different similarity measures preserve different forms of spectral evidence. We introduce , a peak-oriented index based on one-to-one band assignment and explicit penalties for unmatched peaks, and evaluate it together with pointwise, rigid-alignment, elastic-alignment, and derivative-based measures. The benchmark comprises 500 baseline-corrected reference spectra and 50,000 controlled perturbed queries. Each noisy query was independently converted to a peak table before evaluation. Parameter sensitivity was assessed on 350 calibration references, after which the selected configuration and a single hybrid-ranking weight were fixed for 150 held-out references. The moderate association between and the waveform metrics (–) indicates that band correspondence retains information not captured by waveform agreement alone. In full-library retrieval, standalone attained a held-out Top-1 recovery of 0.9603. Combining with cosine similarity, Pearson correlation, cross-correlation, or cross-cosine similarity using the same calibration-selected weight () increased their respective Top-1 recovery rates from 0.4166 to 0.8828, 0.3960 to 0.9094, 0.9449 to 0.9930, and 0.9523 to 0.9933; reference-level bootstrap intervals for all four changes excluded zero. These results establish as a complementary structural layer that can strengthen both shift-sensitive and shift-tolerant library rankings, rather than as a universal replacement for waveform metrics. - 28 June 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (11) , 1800-1810
Comparative Raman–FTIR Assessment of Crystallinity and Carbonate Substitution in Bioapatite‐Based Graft Materials
We investigated the physicochemical characteristics of commercially available bone graft substitutes of bovine, human, and natural hydroxyapatite origin, aiming to evaluate whether compositional differences detectable by vibrational spectroscopy may influence their suitability for bone regeneration. Raman and Fourier transform infrared (FTIR) spectroscopy techniques were employed to examine the vibrational signatures of phosphate and carbonate groups in the mineral phase, focusing on spectral descriptors associated with crystallinity, carbonate substitution, and lattice ordering. Carbonate‐to‐phosphate ratios derived from both Raman and FTIR spectra were used for a comparative assessment of the mineral composition of the different graft types. All materials exhibited characteristic phosphate and carbonate bands consistent with hydroxyapatite as the dominant mineral phase. Minor variations were observed in band positions/widths and carbonate‐related features, indicating subtle differences in structural order that can be attributed to specific manufacturing processes in the synthesis. However, the carbonate‐to‐phosphate ratios showed limited variability, and only minor changes in carbonate‐related spectral parameters were observed among bovine, human, and natural hydroxyapatite grafts. This study provides a methodological reference for carbonate substitution and crystallinity analysis, clarifying structural trends across commercial bioapatite grafts and supporting future research in this field. Even though the observed compositional differences are small, this study confirms that commercial grafts share a highly similar mineral framework, indicating a broad physicochemical similarity among the evaluated graft materials.
- 28 June 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (11) , 1800-1810
Comparative Raman–FTIR Assessment of Crystallinity and Carbonate Substitution in Bioapatite‐Based Graft Materials
We investigated the physicochemical characteristics of commercially available bone graft substitutes of bovine, human, and natural hydroxyapatite origin, aiming to evaluate whether compositional differences detectable by vibrational spectroscopy may influence their suitability for bone regeneration. Raman and Fourier transform infrared (FTIR) spectroscopy techniques were employed to examine the vibrational signatures of phosphate and carbonate groups in the mineral phase, focusing on spectral descriptors associated with crystallinity, carbonate substitution, and lattice ordering. Carbonate‐to‐phosphate ratios derived from both Raman and FTIR spectra were used for a comparative assessment of the mineral composition of the different graft types. All materials exhibited characteristic phosphate and carbonate bands consistent with hydroxyapatite as the dominant mineral phase. Minor variations were observed in band positions/widths and carbonate‐related features, indicating subtle differences in structural order that can be attributed to specific manufacturing processes in the synthesis. However, the carbonate‐to‐phosphate ratios showed limited variability, and only minor changes in carbonate‐related spectral parameters were observed among bovine, human, and natural hydroxyapatite grafts. This study provides a methodological reference for carbonate substitution and crystallinity analysis, clarifying structural trends across commercial bioapatite grafts and supporting future research in this field. Even though the observed compositional differences are small, this study confirms that commercial grafts share a highly similar mineral framework, indicating a broad physicochemical similarity among the evaluated graft materials.
- Open Access
- 12 May 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (10) , 594
Raman and SERS Spectra of Human Myelin Basic Protein in Cerebrospinal Fluid
Raman spectroscopy (RS) provides detailed information on molecular structure but remains challenging for low-scattering proteins in complex media. Myelin basic protein (MBP) is a key structural component of central nervous system myelin and a clinically relevant molecule in demyelinating disorders; however, to the best of our knowledge, its Raman signature in solution has not been reported. In this work, Raman and surface-enhanced Raman spectroscopy (SERS) were employed to characterize purified human myelin basic protein (MBP) in aqueous solution and cerebrospinal fluid (CSF). Quasi-spherical silver nanoparticles were used as SERS elements, yielding enhancement factors of 105 and increasing sensitivity to MBP-associated spectral changes at low concentrations. The MBP spectrum exhibited vibrational modes primarily associated with amide II and amide III bands, as well as aromatic side-chain contributions. Comparative analysis of MBP, CSF, and MBP-spiked CSF samples revealed significant spectral overlap, limiting discrimination based solely on peak positions. To overcome this limitation, spectral correlation and band-intensity-ratio analyses were applied, revealing reproducible trends associated with increasing MBP content. While individual MBP bands are not exclusive, the observed spectral patterns demonstrate the sensitivity of RS and SERS to MBP-induced spectral changes in CSF. These findings should be interpreted as a proof-of-concept in a single-donor CSF matrix.
- 12 May 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (10) , 594
Open AccessRaman and SERS Spectra of Human Myelin Basic Protein in Cerebrospinal Fluid
Raman spectroscopy (RS) provides detailed information on molecular structure but remains challenging for low-scattering proteins in complex media. Myelin basic protein (MBP) is a key structural component of central nervous system myelin and a clinically relevant molecule in demyelinating disorders; however, to the best of our knowledge, its Raman signature in solution has not been reported. In this work, Raman and surface-enhanced Raman spectroscopy (SERS) were employed to characterize purified human myelin basic protein (MBP) in aqueous solution and cerebrospinal fluid (CSF). Quasi-spherical silver nanoparticles were used as SERS elements, yielding enhancement factors of 105 and increasing sensitivity to MBP-associated spectral changes at low concentrations. The MBP spectrum exhibited vibrational modes primarily associated with amide II and amide III bands, as well as aromatic side-chain contributions. Comparative analysis of MBP, CSF, and MBP-spiked CSF samples revealed significant spectral overlap, limiting discrimination based solely on peak positions. To overcome this limitation, spectral correlation and band-intensity-ratio analyses were applied, revealing reproducible trends associated with increasing MBP content. While individual MBP bands are not exclusive, the observed spectral patterns demonstrate the sensitivity of RS and SERS to MBP-induced spectral changes in CSF. These findings should be interpreted as a proof-of-concept in a single-donor CSF matrix.
- 6 February 2026
- Published by Wiley in World Journal of Surgery
- Vol. 50 (3) , 750-759
Thermography‐Assisted Grading in Wagner Classification: A New Approach for Diabetic Foot Assessment. A Cross‐Sectional Study
Background: Diabetic foot is a serious complication of diabetes mellitus that generates lifelong consequences on the health and quality of life of affected patients. One of the first grading systems developed for diabetic foot was the Wagner classification system. Despite its prolonged use in the medical field, accurate clinical assessment requires an experienced evaluator to minimize errors and bias. Using infrared thermography, a technology that quantitatively measures temperature changes in areas of interest related to altered vascular flow derived from inflammatory processes, could diminish the subjective bias associated with clinical evaluation. Objective: To determine the thermographic pattern of the different grades of the Wagner classification system for diabetic foot. Methods: We evaluated thermographic images of 66 patients diagnosed with diabetic foot. Clinical data and infrared thermographic images were acquired at the moment of evaluation. Temperature differences (ΔT) between the first toe of the affected limb and the contralateral unaffected first toe were recorded and analyzed with computer software. The thermographic patterns were then compared with the Wagner classification system grades. Results: A positive ΔT was observed in 36 patients in the first three Wagner grades: Wagner 0, ΔT 0.71°C ± 0.43; Wagner 1, ΔT 1.17°C ± 1.88; and Wagner 2, ΔT 2.18°C ± 2.38. Thirty patients presented negative ΔT from the third grade onward: Wagner 3, ΔT −2.66°C ± 1.14; Wagner 4, ΔT −5.92°C ± 1.75, and Wagner 5, ΔT −6.92°C ± 1.28. Then, we separate the cohort into two groups: patients who required amputation and those who required conservative management. A threshold in the ΔT value of −2.6 correctly predicted the outcome in more than 95% of patients. Conclusions: These results suggest a potential application for thermography as an adjunctive tool in wound clinics, enabling the accurate evaluation of diabetic foot ulcers and as a predictor of patients' outcomes. Trial Registration: Registry: 08‐23 by the Hospital Regional de Alta Especialidad “Dr. Ignacio Morones Prieto” Research Ethics Committee (CONBIOÉTICA‐24‐CEI‐001‐20160427)
- 6 February 2026
- Published by Wiley in World Journal of Surgery
- Vol. 50 (3) , 750-759
Thermography‐Assisted Grading in Wagner Classification: A New Approach for Diabetic Foot Assessment. A Cross‐Sectional Study
Background: Diabetic foot is a serious complication of diabetes mellitus that generates lifelong consequences on the health and quality of life of affected patients. One of the first grading systems developed for diabetic foot was the Wagner classification system. Despite its prolonged use in the medical field, accurate clinical assessment requires an experienced evaluator to minimize errors and bias. Using infrared thermography, a technology that quantitatively measures temperature changes in areas of interest related to altered vascular flow derived from inflammatory processes, could diminish the subjective bias associated with clinical evaluation. Objective: To determine the thermographic pattern of the different grades of the Wagner classification system for diabetic foot. Methods: We evaluated thermographic images of 66 patients diagnosed with diabetic foot. Clinical data and infrared thermographic images were acquired at the moment of evaluation. Temperature differences (ΔT) between the first toe of the affected limb and the contralateral unaffected first toe were recorded and analyzed with computer software. The thermographic patterns were then compared with the Wagner classification system grades. Results: A positive ΔT was observed in 36 patients in the first three Wagner grades: Wagner 0, ΔT 0.71°C ± 0.43; Wagner 1, ΔT 1.17°C ± 1.88; and Wagner 2, ΔT 2.18°C ± 2.38. Thirty patients presented negative ΔT from the third grade onward: Wagner 3, ΔT −2.66°C ± 1.14; Wagner 4, ΔT −5.92°C ± 1.75, and Wagner 5, ΔT −6.92°C ± 1.28. Then, we separate the cohort into two groups: patients who required amputation and those who required conservative management. A threshold in the ΔT value of −2.6 correctly predicted the outcome in more than 95% of patients. Conclusions: These results suggest a potential application for thermography as an adjunctive tool in wound clinics, enabling the accurate evaluation of diabetic foot ulcers and as a predictor of patients' outcomes. Trial Registration: Registry: 08‐23 by the Hospital Regional de Alta Especialidad “Dr. Ignacio Morones Prieto” Research Ethics Committee (CONBIOÉTICA‐24‐CEI‐001‐20160427)
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Polímeros
- Vol. 36 (3)
Harnessing natural monoterpenes: cold plasma polymerization of citronellol
This study presents the cold plasma polymerization of citronellol, a natural monoterpene, as a route to obtain antibacterial polymeric films. A 10 µL volume of citronellol was polymerized under argon plasma at 100 Pa, yielding a solid film (Pcit). SEM analysis revealed a heterogeneous, branched surface with a roughness Ra of 7.53 ± 2.19 µm and Rz of 50.57 ± 24.26 µm. Water contact angle measurements indicated moderate hydrophilicity (62°). XPS and FTIR analyses confirmed the presence of oxygen-containing functional groups, while OES detected reactive carbon- and oxygen-containing species generated during plasma operation. Hemolysis tests showed excellent blood compatibility (<5%), and antimicrobial assays revealed inhibition zones of 12 ± 1 mm for E. coli and 10 ± 1 mm for S. aureus. Overall, these results indicate that plasma-polymerized citronellol yields functional surfaces with promising potential for biomedical and antibacterial applications.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Polímeros
- Vol. 36 (3)
Open AccessHarnessing natural monoterpenes: cold plasma polymerization of citronellol
This study presents the cold plasma polymerization of citronellol, a natural monoterpene, as a route to obtain antibacterial polymeric films. A 10 µL volume of citronellol was polymerized under argon plasma at 100 Pa, yielding a solid film (Pcit). SEM analysis revealed a heterogeneous, branched surface with a roughness Ra of 7.53 ± 2.19 µm and Rz of 50.57 ± 24.26 µm. Water contact angle measurements indicated moderate hydrophilicity (62°). XPS and FTIR analyses confirmed the presence of oxygen-containing functional groups, while OES detected reactive carbon- and oxygen-containing species generated during plasma operation. Hemolysis tests showed excellent blood compatibility (<5%), and antimicrobial assays revealed inhibition zones of 12 ± 1 mm for E. coli and 10 ± 1 mm for S. aureus. Overall, these results indicate that plasma-polymerized citronellol yields functional surfaces with promising potential for biomedical and antibacterial applications.
- Open Access
Asymmetric Dimethylarginine Vibrational Spectroscopy Spectra and Density Functional Theory Model
NG, NG-dimethylarginine (ADMA) is an endogenous compound that acts as a competitive inhibitor of nitric oxide synthase (NOS), thereby reducing nitric oxide (NO) production and contributing to endothelial dysfunction. This dysfunction plays a pivotal role in the development of various pathological conditions, including cardiovascular disease, chronic renal failure, and diabetes. The diminished bioavailability of NO is a critical factor in the progression of these disorders, and alterations in ADMA levels have emerged as significant predictors of cardiovascular events and mortality. In this study, we investigated the molecular characteristics of ADMA using a combined approach of Raman and Fourier Transform Infrared (FT-IR) spectroscopy, complemented by computational simulations with the GaussView 5.0.8 and Gaussian 09 software suite. Experimental Raman and FT-IR spectra were acquired and compared with simulated spectra generated through Density Functional Theory (DFT) calculations. This comparative analysis enabled precise vibrational band assignments and the identification of key molecular vibrational modes, providing valuable insights into ADMA’s structural and vibrational properties. These findings establish a comprehensive spectroscopic reference for ADMA, supporting its potential application as a biomarker in clinical diagnostics.
Open AccessAsymmetric Dimethylarginine Vibrational Spectroscopy Spectra and Density Functional Theory Model
NG, NG-dimethylarginine (ADMA) is an endogenous compound that acts as a competitive inhibitor of nitric oxide synthase (NOS), thereby reducing nitric oxide (NO) production and contributing to endothelial dysfunction. This dysfunction plays a pivotal role in the development of various pathological conditions, including cardiovascular disease, chronic renal failure, and diabetes. The diminished bioavailability of NO is a critical factor in the progression of these disorders, and alterations in ADMA levels have emerged as significant predictors of cardiovascular events and mortality. In this study, we investigated the molecular characteristics of ADMA using a combined approach of Raman and Fourier Transform Infrared (FT-IR) spectroscopy, complemented by computational simulations with the GaussView 5.0.8 and Gaussian 09 software suite. Experimental Raman and FT-IR spectra were acquired and compared with simulated spectra generated through Density Functional Theory (DFT) calculations. This comparative analysis enabled precise vibrational band assignments and the identification of key molecular vibrational modes, providing valuable insights into ADMA’s structural and vibrational properties. These findings establish a comprehensive spectroscopic reference for ADMA, supporting its potential application as a biomarker in clinical diagnostics.
- 30 June 2024
- Published by Universidad Autonoma Metropolitana in Revista Mexicana de Ingeniería Química
- Vol. 23 (3) , 1-21
Cold plasma oligomerization in argon atmosphere from carvacrol: Product formation and characterization
- 30 June 2024
- Published by Universidad Autonoma Metropolitana in Revista Mexicana de Ingeniería Química
- Vol. 23 (3) , 1-21
Cold plasma oligomerization in argon atmosphere from carvacrol: Product formation and characterization
- 7 September 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 147, 106108
Preparation and evaluation of (R)-(−)-carvone-doped polymeric resins as potential antibacterial dental materials
- 7 September 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 147, 106108
Preparation and evaluation of (R)-(−)-carvone-doped polymeric resins as potential antibacterial dental materials
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Polímeros
- Vol. 33 (4) , e20230038
Cold plasma copolymer with antimicrobial activity deposited on three different substrates
A good strategy to prevent early deposition of bacteria that can form biofilms is the application of antimicrobial coatings to existing surfaces, however this field has been little explored and coatings are often non uniform in thickness. A homogeneous film of R-Carvone-Octadiene (ppCop) was deposited on different substrates (coverslip, minced coverslip and fabric) by cold plasma copolymerization to study the influence of the substrate on antimicrobial activity and show clues about the influence of octadiene on copolymerization. The ppCop showed better antimicrobial activity results on the substrate with higher effective contact area, highlighting the influence of this variable on antimicrobial activity. The ppCop deposited on minced coverslip showed an inhibition of E. coli and S. aureus bacteria by 48.69 ±0.08% and 49.31 ±0.58% respectively, with an average roughness of 14.1±0.02 nm and a static water contact angle of 79± 0.4°. The ppCop showed no cytotoxicity to the human cell line.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Polímeros
- Vol. 33 (4) , e20230038
Open AccessCold plasma copolymer with antimicrobial activity deposited on three different substrates
A good strategy to prevent early deposition of bacteria that can form biofilms is the application of antimicrobial coatings to existing surfaces, however this field has been little explored and coatings are often non uniform in thickness. A homogeneous film of R-Carvone-Octadiene (ppCop) was deposited on different substrates (coverslip, minced coverslip and fabric) by cold plasma copolymerization to study the influence of the substrate on antimicrobial activity and show clues about the influence of octadiene on copolymerization. The ppCop showed better antimicrobial activity results on the substrate with higher effective contact area, highlighting the influence of this variable on antimicrobial activity. The ppCop deposited on minced coverslip showed an inhibition of E. coli and S. aureus bacteria by 48.69 ±0.08% and 49.31 ±0.58% respectively, with an average roughness of 14.1±0.02 nm and a static water contact angle of 79± 0.4°. The ppCop showed no cytotoxicity to the human cell line.
- 15 April 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (5) , 4663-4669
Embedding Sodium Ions in Graphitic Carbon Nitride Vacancies for Visible Light Photocatalytic H2 Evolution
- 15 April 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (5) , 4663-4669
Embedding Sodium Ions in Graphitic Carbon Nitride Vacancies for Visible Light Photocatalytic H2 Evolution