Emmanuel Rivera-Perez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emmanuel Rivera-Perez has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Adán Reyes-Reyes
Facultad de Ciencias, Universidad Autónoma de San Luis Potosí, Av. Parque Chapultepec 1570, San Luis Potosí 78295, México
3 shared publications - Alejandra Ortiz-Dosal
Facultad de Ciencias, Universidad Autónoma de San Luis Potosí, Av. Parque Chapultepec 1570, San Luis Potosí 78295, México
3 shared publications - Eleazar Samuel Kolosovas-Machuca
Universidad Autónoma de San Luis Potosí
3 shared publications - Erick Osvaldo Martínez-Ruiz
Facultad de Ciencias, Universidad Autónoma de San Luis Potosí, Av. Parque Chapultepec 1570, San Luis Potosí 78295, México
3 shared publications - Maria del Carmen Rodríguez-Aranda
Coordinación para la Innovación y Aplicación de la Ciencia y la Tecnología (CIACyT), Universidad Autónoma de San Luis Potosí, Av. Sierra Leona 550, San Luis Potosí 78210, Mexico
3 shared publications - Christopher Jesus Rodriguez-Cortes
Faculty of Science, Autonomous University of San Luis Potosi (UASLP), San Luis Potosi 78295, SLP, Mexico
2 shared publications
Latest Publications
- Open Access
- 22 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035020
Real-time spectral dynamics of Kerr-effect all-optical switching in long-period fiber gratings
We report the first direct experimental measurement of the time-resolved transmission spectrum of an long-period fiber grating (LPG) during nonlinear Kerr-effect switching, enabling simultaneous temporal and spectral reconstruction of the full transmission dynamics. Using a pump–probe technique, we directly record the temporal evolution of the LPG transmission spectrum as intense pump pulses propagate through the grating, enabling visualization of the switching process with unprecedented combined temporal and spectral resolution. Analytical expressions derived from coupled-mode theory accurately reproduce the measured probe dynamics, providing quantitative insight into the dependence of the switching behavior on pump and grating parameters. Experiments performed with both short (40 ps) and long (700 ps) pump pulses reveal comparable switching performance, achieving an ON–OFF contrast ratio of 18 dB and an insertion loss of 3 dB in the ON state around 1556 nm for a pump peak intensity of 9.4 GW cm −2 at 1064 nm. In the short-pulse regime, transient probe transmittance values exceeding unity are observed within a limited spectral and time windows; this behavior, which does not imply optical gain, is fully explained by the model and originates from ultrafast pump-induced power redistribution. This transient phenomenon, together with the spectral reshaping of the LPG transmittance that induces a short-lived blue-shift of the −3 dB point, constitutes a dynamical signature not captured by prior models of Kerr-LPG switching. These results demonstrate the robustness of Kerr-based LPG switching across distinct temporal regimes and establish real-time spectral characterization as a powerful tool for the optimization of ultrafast fiber-grating devices.
- 22 July 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (3) , 035020
Open AccessReal-time spectral dynamics of Kerr-effect all-optical switching in long-period fiber gratings
We report the first direct experimental measurement of the time-resolved transmission spectrum of an long-period fiber grating (LPG) during nonlinear Kerr-effect switching, enabling simultaneous temporal and spectral reconstruction of the full transmission dynamics. Using a pump–probe technique, we directly record the temporal evolution of the LPG transmission spectrum as intense pump pulses propagate through the grating, enabling visualization of the switching process with unprecedented combined temporal and spectral resolution. Analytical expressions derived from coupled-mode theory accurately reproduce the measured probe dynamics, providing quantitative insight into the dependence of the switching behavior on pump and grating parameters. Experiments performed with both short (40 ps) and long (700 ps) pump pulses reveal comparable switching performance, achieving an ON–OFF contrast ratio of 18 dB and an insertion loss of 3 dB in the ON state around 1556 nm for a pump peak intensity of 9.4 GW cm −2 at 1064 nm. In the short-pulse regime, transient probe transmittance values exceeding unity are observed within a limited spectral and time windows; this behavior, which does not imply optical gain, is fully explained by the model and originates from ultrafast pump-induced power redistribution. This transient phenomenon, together with the spectral reshaping of the LPG transmittance that induces a short-lived blue-shift of the −3 dB point, constitutes a dynamical signature not captured by prior models of Kerr-LPG switching. These results demonstrate the robustness of Kerr-based LPG switching across distinct temporal regimes and establish real-time spectral characterization as a powerful tool for the optimization of ultrafast fiber-grating devices.
- 28 June 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (11) , 1800-1810
Comparative Raman–FTIR Assessment of Crystallinity and Carbonate Substitution in Bioapatite‐Based Graft Materials
We investigated the physicochemical characteristics of commercially available bone graft substitutes of bovine, human, and natural hydroxyapatite origin, aiming to evaluate whether compositional differences detectable by vibrational spectroscopy may influence their suitability for bone regeneration. Raman and Fourier transform infrared (FTIR) spectroscopy techniques were employed to examine the vibrational signatures of phosphate and carbonate groups in the mineral phase, focusing on spectral descriptors associated with crystallinity, carbonate substitution, and lattice ordering. Carbonate‐to‐phosphate ratios derived from both Raman and FTIR spectra were used for a comparative assessment of the mineral composition of the different graft types. All materials exhibited characteristic phosphate and carbonate bands consistent with hydroxyapatite as the dominant mineral phase. Minor variations were observed in band positions/widths and carbonate‐related features, indicating subtle differences in structural order that can be attributed to specific manufacturing processes in the synthesis. However, the carbonate‐to‐phosphate ratios showed limited variability, and only minor changes in carbonate‐related spectral parameters were observed among bovine, human, and natural hydroxyapatite grafts. This study provides a methodological reference for carbonate substitution and crystallinity analysis, clarifying structural trends across commercial bioapatite grafts and supporting future research in this field. Even though the observed compositional differences are small, this study confirms that commercial grafts share a highly similar mineral framework, indicating a broad physicochemical similarity among the evaluated graft materials.
- 28 June 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (11) , 1800-1810
Comparative Raman–FTIR Assessment of Crystallinity and Carbonate Substitution in Bioapatite‐Based Graft Materials
We investigated the physicochemical characteristics of commercially available bone graft substitutes of bovine, human, and natural hydroxyapatite origin, aiming to evaluate whether compositional differences detectable by vibrational spectroscopy may influence their suitability for bone regeneration. Raman and Fourier transform infrared (FTIR) spectroscopy techniques were employed to examine the vibrational signatures of phosphate and carbonate groups in the mineral phase, focusing on spectral descriptors associated with crystallinity, carbonate substitution, and lattice ordering. Carbonate‐to‐phosphate ratios derived from both Raman and FTIR spectra were used for a comparative assessment of the mineral composition of the different graft types. All materials exhibited characteristic phosphate and carbonate bands consistent with hydroxyapatite as the dominant mineral phase. Minor variations were observed in band positions/widths and carbonate‐related features, indicating subtle differences in structural order that can be attributed to specific manufacturing processes in the synthesis. However, the carbonate‐to‐phosphate ratios showed limited variability, and only minor changes in carbonate‐related spectral parameters were observed among bovine, human, and natural hydroxyapatite grafts. This study provides a methodological reference for carbonate substitution and crystallinity analysis, clarifying structural trends across commercial bioapatite grafts and supporting future research in this field. Even though the observed compositional differences are small, this study confirms that commercial grafts share a highly similar mineral framework, indicating a broad physicochemical similarity among the evaluated graft materials.
- Open Access
- 12 May 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (10) , 594
Raman and SERS Spectra of Human Myelin Basic Protein in Cerebrospinal Fluid
Raman spectroscopy (RS) provides detailed information on molecular structure but remains challenging for low-scattering proteins in complex media. Myelin basic protein (MBP) is a key structural component of central nervous system myelin and a clinically relevant molecule in demyelinating disorders; however, to the best of our knowledge, its Raman signature in solution has not been reported. In this work, Raman and surface-enhanced Raman spectroscopy (SERS) were employed to characterize purified human myelin basic protein (MBP) in aqueous solution and cerebrospinal fluid (CSF). Quasi-spherical silver nanoparticles were used as SERS elements, yielding enhancement factors of 105 and increasing sensitivity to MBP-associated spectral changes at low concentrations. The MBP spectrum exhibited vibrational modes primarily associated with amide II and amide III bands, as well as aromatic side-chain contributions. Comparative analysis of MBP, CSF, and MBP-spiked CSF samples revealed significant spectral overlap, limiting discrimination based solely on peak positions. To overcome this limitation, spectral correlation and band-intensity-ratio analyses were applied, revealing reproducible trends associated with increasing MBP content. While individual MBP bands are not exclusive, the observed spectral patterns demonstrate the sensitivity of RS and SERS to MBP-induced spectral changes in CSF. These findings should be interpreted as a proof-of-concept in a single-donor CSF matrix.
- 12 May 2026
- Published by MDPI AG in Nanomaterials
- Vol. 16 (10) , 594
Open AccessRaman and SERS Spectra of Human Myelin Basic Protein in Cerebrospinal Fluid
Raman spectroscopy (RS) provides detailed information on molecular structure but remains challenging for low-scattering proteins in complex media. Myelin basic protein (MBP) is a key structural component of central nervous system myelin and a clinically relevant molecule in demyelinating disorders; however, to the best of our knowledge, its Raman signature in solution has not been reported. In this work, Raman and surface-enhanced Raman spectroscopy (SERS) were employed to characterize purified human myelin basic protein (MBP) in aqueous solution and cerebrospinal fluid (CSF). Quasi-spherical silver nanoparticles were used as SERS elements, yielding enhancement factors of 105 and increasing sensitivity to MBP-associated spectral changes at low concentrations. The MBP spectrum exhibited vibrational modes primarily associated with amide II and amide III bands, as well as aromatic side-chain contributions. Comparative analysis of MBP, CSF, and MBP-spiked CSF samples revealed significant spectral overlap, limiting discrimination based solely on peak positions. To overcome this limitation, spectral correlation and band-intensity-ratio analyses were applied, revealing reproducible trends associated with increasing MBP content. While individual MBP bands are not exclusive, the observed spectral patterns demonstrate the sensitivity of RS and SERS to MBP-induced spectral changes in CSF. These findings should be interpreted as a proof-of-concept in a single-donor CSF matrix.
- Open Access
Asymmetric Dimethylarginine Vibrational Spectroscopy Spectra and Density Functional Theory Model
NG, NG-dimethylarginine (ADMA) is an endogenous compound that acts as a competitive inhibitor of nitric oxide synthase (NOS), thereby reducing nitric oxide (NO) production and contributing to endothelial dysfunction. This dysfunction plays a pivotal role in the development of various pathological conditions, including cardiovascular disease, chronic renal failure, and diabetes. The diminished bioavailability of NO is a critical factor in the progression of these disorders, and alterations in ADMA levels have emerged as significant predictors of cardiovascular events and mortality. In this study, we investigated the molecular characteristics of ADMA using a combined approach of Raman and Fourier Transform Infrared (FT-IR) spectroscopy, complemented by computational simulations with the GaussView 5.0.8 and Gaussian 09 software suite. Experimental Raman and FT-IR spectra were acquired and compared with simulated spectra generated through Density Functional Theory (DFT) calculations. This comparative analysis enabled precise vibrational band assignments and the identification of key molecular vibrational modes, providing valuable insights into ADMA’s structural and vibrational properties. These findings establish a comprehensive spectroscopic reference for ADMA, supporting its potential application as a biomarker in clinical diagnostics.
Open AccessAsymmetric Dimethylarginine Vibrational Spectroscopy Spectra and Density Functional Theory Model
NG, NG-dimethylarginine (ADMA) is an endogenous compound that acts as a competitive inhibitor of nitric oxide synthase (NOS), thereby reducing nitric oxide (NO) production and contributing to endothelial dysfunction. This dysfunction plays a pivotal role in the development of various pathological conditions, including cardiovascular disease, chronic renal failure, and diabetes. The diminished bioavailability of NO is a critical factor in the progression of these disorders, and alterations in ADMA levels have emerged as significant predictors of cardiovascular events and mortality. In this study, we investigated the molecular characteristics of ADMA using a combined approach of Raman and Fourier Transform Infrared (FT-IR) spectroscopy, complemented by computational simulations with the GaussView 5.0.8 and Gaussian 09 software suite. Experimental Raman and FT-IR spectra were acquired and compared with simulated spectra generated through Density Functional Theory (DFT) calculations. This comparative analysis enabled precise vibrational band assignments and the identification of key molecular vibrational modes, providing valuable insights into ADMA’s structural and vibrational properties. These findings establish a comprehensive spectroscopic reference for ADMA, supporting its potential application as a biomarker in clinical diagnostics.
- Open Access
- 20 October 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (20) , 9317
Three-Phase Space Vector PWM Inverter for Induction Motor Drive with Leakage Current Reduction
Several industrial applications rely on induction motors to carry out processes essential for product manufacturing. Speed control of an induction motor commonly requires a pulse width modulated inverter capable of driving a system with long cables, suppression of common mode voltage, reduction in common mode current, and suppression of electromagnetic interference. This paper proposes a three-phase motor drive aimed at maintaining a constant common-mode voltage. The proposed system consists of two three-phase conventional full bridge inverters connected in parallel and having as an input two separate direct current sources. The proposed system is controlled by using the space vector pulse width modulation technique. By properly designing the switching signal sequences for both converters, the common-mode voltage can be maintained constant, thereby reducing the associated common-mode current to an RMS value of mA and enhancing the overall reliability of the system. The proposed system is validated through numerical simulations and by the implementation of an experimental prototype.- 20 October 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (20) , 9317
Open AccessThree-Phase Space Vector PWM Inverter for Induction Motor Drive with Leakage Current Reduction
Several industrial applications rely on induction motors to carry out processes essential for product manufacturing. Speed control of an induction motor commonly requires a pulse width modulated inverter capable of driving a system with long cables, suppression of common mode voltage, reduction in common mode current, and suppression of electromagnetic interference. This paper proposes a three-phase motor drive aimed at maintaining a constant common-mode voltage. The proposed system consists of two three-phase conventional full bridge inverters connected in parallel and having as an input two separate direct current sources. The proposed system is controlled by using the space vector pulse width modulation technique. By properly designing the switching signal sequences for both converters, the common-mode voltage can be maintained constant, thereby reducing the associated common-mode current to an RMS value of mA and enhancing the overall reliability of the system. The proposed system is validated through numerical simulations and by the implementation of an experimental prototype. - Open Access
- 19 August 2025
- Published by MDPI AG in Preprints.org
A Three-Phase Space Vector PWM Inverter for Induction Motor Drive with Leakage Current Reduction
Several industrial applications rely on induction motors to carry out processes essential for product manufacturing. Speed control of an induction motor commonly requires a pulse width modulated inverter capable of driving a system with long cables, suppression of common mode voltage, reduction of common mode current, and suppression of electromagnetic interference. This paper proposes a three-phase motor drive aimed to make constant the common mode voltage. The proposed system consists of two three-phase conventional full bridge inverters connected in parallel and having as an input two separate direct current sources. The proposed system is controlled by using the space vector pulse width modulation technique. By designing the adequate signal sequences of the switches for both converters, it is possible to keep constant the common model voltage and therefore reduce the associated common mode current making the system more reliable. The proposed system is validated through numerical simulations and by the implementation of an experimental prototype. Low common mode current values as low as 83mA are obtained in both simulations and experiments.
- 19 August 2025
- Published by MDPI AG in Preprints.org
Open AccessA Three-Phase Space Vector PWM Inverter for Induction Motor Drive with Leakage Current Reduction
Several industrial applications rely on induction motors to carry out processes essential for product manufacturing. Speed control of an induction motor commonly requires a pulse width modulated inverter capable of driving a system with long cables, suppression of common mode voltage, reduction of common mode current, and suppression of electromagnetic interference. This paper proposes a three-phase motor drive aimed to make constant the common mode voltage. The proposed system consists of two three-phase conventional full bridge inverters connected in parallel and having as an input two separate direct current sources. The proposed system is controlled by using the space vector pulse width modulation technique. By designing the adequate signal sequences of the switches for both converters, it is possible to keep constant the common model voltage and therefore reduce the associated common mode current making the system more reliable. The proposed system is validated through numerical simulations and by the implementation of an experimental prototype. Low common mode current values as low as 83mA are obtained in both simulations and experiments.