Jamal Siam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jamal Siam has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Ali Abdo
Department of Electrical and Computer Engineering, Birzeit University, Birzeit, Palestine
18 shared publications - Hakam Shehadeh
Electrical and Computer Engineering Department, Birzeit University, Birzeit, Palestine
8 shared publications - Rashad Mustafa
Department of Mechanical and Mechatronics Engineering, Faculty of Engineering and Technology, Birzeit University, Birzeit 9730000, Palestine
6 shared publications - Ahmed Abdou
Department of Engineering, Palestine Ahliya University, Bethlehem P, Palestine
3 shared publications Ashraf Al-Rimawi
Electrical and Computer Engineering Department, Birzeit University, Birzeit, Palestine
3 shared publicationsOfer Barnea
Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
3 shared publications
Latest Publications
- Open Access
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 20671-20680
Fault-Tolerant Control Strategies for Switching Motor Stator Windings Under Single Phasing
Single-phasing faults in three-phase induction motors can lead to a significant rise in stator winding temperatures, posing a risk of thermal damage and reduced motor lifespan. While the conventional response is to shut down the motor during such faults, this approach can disrupt industrial operations and critical services such as elevators, cooling, and ventilation systems. This research presents a practical and innovative fault tolerant control strategy that enables continued motor operation under single-phasing conditions without compromising reliability or longevity. The proposed method employs a switching technique to redistribute current flow within the stator windings, thereby mitigating overheating. A detailed thermal model is developed and analyzed to assess the temperature behavior and ensure effective protection of the motor. Experimental validation confirms that the control scheme maintains safe operating temperatures, allowing the motor to function efficiently during single-phasing. This solution offers a reliable alternative to shutdowns, enhancing the resilience and availability of three-phase induction motors in essential applications.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 20671-20680
Open AccessFault-Tolerant Control Strategies for Switching Motor Stator Windings Under Single Phasing
Single-phasing faults in three-phase induction motors can lead to a significant rise in stator winding temperatures, posing a risk of thermal damage and reduced motor lifespan. While the conventional response is to shut down the motor during such faults, this approach can disrupt industrial operations and critical services such as elevators, cooling, and ventilation systems. This research presents a practical and innovative fault tolerant control strategy that enables continued motor operation under single-phasing conditions without compromising reliability or longevity. The proposed method employs a switching technique to redistribute current flow within the stator windings, thereby mitigating overheating. A detailed thermal model is developed and analyzed to assess the temperature behavior and ensure effective protection of the motor. Experimental validation confirms that the control scheme maintains safe operating temperatures, allowing the motor to function efficiently during single-phasing. This solution offers a reliable alternative to shutdowns, enhancing the resilience and availability of three-phase induction motors in essential applications.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Fault Detection and Fault-Tolerant Control of Single Phasing on Three-Phase System
This paper introduces a new and cost-effective solution to the long-standing problem of single phasing in electrical systems. It addresses the challenges caused by the failure of one phase in three-phase systems, improving reliability and performance for industrial and residential applications. The proposed method uses boost converter circuits to create a fault-tolerant approach. We describe a technique that converts the three-phase signal into direct current (DC) to compensate for the missing phase. Then, it reconstructs a balanced three-phase output using an inverter. This method ensures stable and efficient power generation, providing a versatile solution suitable for various load requirements. We conducted extensive analysis to assess power output, boost converter efficiency, and the impact of inverter integration. We also examined critical issues such as power delivery to loads, transient responses, and harmonic distortions under faulty conditions. Additionally, we investigated the system’s performance when multiple phases may be lost. Our findings offer valuable insights into the feasibility and practicality of implementing this method in real-world electrical systems. Specifically, this approach demonstrates significant potential to enhance safety and operational reliability in power generation. Moreover, it shows considerable promise in improving the performance and dependability of three-phase loads. A practical test is added to verify the effectiveness of the proposed approach.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Fault Detection and Fault-Tolerant Control of Single Phasing on Three-Phase System
This paper introduces a new and cost-effective solution to the long-standing problem of single phasing in electrical systems. It addresses the challenges caused by the failure of one phase in three-phase systems, improving reliability and performance for industrial and residential applications. The proposed method uses boost converter circuits to create a fault-tolerant approach. We describe a technique that converts the three-phase signal into direct current (DC) to compensate for the missing phase. Then, it reconstructs a balanced three-phase output using an inverter. This method ensures stable and efficient power generation, providing a versatile solution suitable for various load requirements. We conducted extensive analysis to assess power output, boost converter efficiency, and the impact of inverter integration. We also examined critical issues such as power delivery to loads, transient responses, and harmonic distortions under faulty conditions. Additionally, we investigated the system’s performance when multiple phases may be lost. Our findings offer valuable insights into the feasibility and practicality of implementing this method in real-world electrical systems. Specifically, this approach demonstrates significant potential to enhance safety and operational reliability in power generation. Moreover, it shows considerable promise in improving the performance and dependability of three-phase loads. A practical test is added to verify the effectiveness of the proposed approach.
- Open Access
- 29 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4690
Practical Test on the Operation of the Three-Phase Induction Motor under Single-Phasing Fault
Single-phasing is a common problem in the three-phase electrical grid. Despite the fact that the fault occurs in one phasing, the three-phase load is affected, and therefore the load is typically turned off. The three-phase induction motor is the most commonly used in the industry; therefore, this research investigates the behavior of the three-phase induction motor under a single-phasing fault. The main aim of this paper is to answer the question, should the three-phase induction motor be turned off under a single-phasing fault? The problem is investigated theoretically and compared with practical tests to explore the parameters of the induction motor (current, stator temperature, and vibration) that are affected under healthy and single-phasing fault conditions. A practical test machine is built to test the motor behavior under single-phasing faults, where the practical experiment results are compared to those of the simulations. Despite the common recommendation under single-phasing fault is to turn off the induction motors, the preliminary results of this study show that turning off an induction motor under single-phasing can be avoided under certain operating conditions with a simple protection scheme, which is useful in some practical situations.
- 29 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4690
Open AccessPractical Test on the Operation of the Three-Phase Induction Motor under Single-Phasing Fault
Single-phasing is a common problem in the three-phase electrical grid. Despite the fact that the fault occurs in one phasing, the three-phase load is affected, and therefore the load is typically turned off. The three-phase induction motor is the most commonly used in the industry; therefore, this research investigates the behavior of the three-phase induction motor under a single-phasing fault. The main aim of this paper is to answer the question, should the three-phase induction motor be turned off under a single-phasing fault? The problem is investigated theoretically and compared with practical tests to explore the parameters of the induction motor (current, stator temperature, and vibration) that are affected under healthy and single-phasing fault conditions. A practical test machine is built to test the motor behavior under single-phasing faults, where the practical experiment results are compared to those of the simulations. Despite the common recommendation under single-phasing fault is to turn off the induction motors, the preliminary results of this study show that turning off an induction motor under single-phasing can be avoided under certain operating conditions with a simple protection scheme, which is useful in some practical situations.
- 4 November 2023
- Published by Springer Nature in International Journal of Automotive Technology
- Vol. 24 (6) , 1567-1575
Dual Clutch Transmission Performance Analysis Using the MGMS-GA Friction Model: Effect of the Piston Seal
- 4 November 2023
- Published by Springer Nature in International Journal of Automotive Technology
- Vol. 24 (6) , 1567-1575
Dual Clutch Transmission Performance Analysis Using the MGMS-GA Friction Model: Effect of the Piston Seal
- Open Access
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 128721-128731
Power Loss and Total Load Demand Coverage in Stand-Alone Microgrids: A Combined and Conventional Droop Control Perspectives
Conventional droop control plays an essential role in microgrids with distributed generators, DGs, and variable load demand. Despite its advantages, the conventional droop scheme does not take into account the minimization of power losses and the maximization of the total load coverage. Moreover, most of the nonconventional droop control studies that address power loss consider one variable load. This study proposes a combined droop scheme and inspects its effects on power loss minimization and total load coverage. The proposed scheme combines conventional and nonconventional droop schemes and constructs a 3D P-f droop characteristic that takes into account the presence of two variable loads. Four and six-bus microgrids are adopted to simulate and illustrate the system behavior in MatLab. Results are compared to the standard fully conventional droop approach; results showed that the combined scheme has higher performance in terms of power loss gain and total load coverage.
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 128721-128731
Open AccessPower Loss and Total Load Demand Coverage in Stand-Alone Microgrids: A Combined and Conventional Droop Control Perspectives
Conventional droop control plays an essential role in microgrids with distributed generators, DGs, and variable load demand. Despite its advantages, the conventional droop scheme does not take into account the minimization of power losses and the maximization of the total load coverage. Moreover, most of the nonconventional droop control studies that address power loss consider one variable load. This study proposes a combined droop scheme and inspects its effects on power loss minimization and total load coverage. The proposed scheme combines conventional and nonconventional droop schemes and constructs a 3D P-f droop characteristic that takes into account the presence of two variable loads. Four and six-bus microgrids are adopted to simulate and illustrate the system behavior in MatLab. Results are compared to the standard fully conventional droop approach; results showed that the combined scheme has higher performance in terms of power loss gain and total load coverage.
- Open Access
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 126516-126524
Piston-Seals Friction Modeling Using a Modified Maxwell Slip Formation and Genetic Identification Algorithm
Improving spontaneity, shifting control, and efficiency are the main goals of actuators for hydraulic automated transmissions. Friction losses of piston-seals play an essential role in achieving these goals. Therefore, modeling the complex friction behavior of piston seals leads to a better understanding of the determinant factors of energy losses and, consequently, the realization of more efficient transmission actuators. This paper proposes a piston-seal friction model based on the Generalized Maxwell-Slip model. The proposed model introduces an additional hydraulic-pressure dependency that emulates the influence of cylinder-pressure on the displacement variable while accounting for various piston-seal structures. A Genetic Algorithm is also applied to identify and optimize the parameters of the proposed friction model. Simulations with O-Ring, D-Ring, and Bonded Piston seals were developed to show the validity of the proposed model in practical scenarios. The results were also compared with the original Generalized Maxwell Slip friction model to show the superiority of the proposed model in representing the experimental data.
- 28 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 126516-126524
Open AccessPiston-Seals Friction Modeling Using a Modified Maxwell Slip Formation and Genetic Identification Algorithm
Improving spontaneity, shifting control, and efficiency are the main goals of actuators for hydraulic automated transmissions. Friction losses of piston-seals play an essential role in achieving these goals. Therefore, modeling the complex friction behavior of piston seals leads to a better understanding of the determinant factors of energy losses and, consequently, the realization of more efficient transmission actuators. This paper proposes a piston-seal friction model based on the Generalized Maxwell-Slip model. The proposed model introduces an additional hydraulic-pressure dependency that emulates the influence of cylinder-pressure on the displacement variable while accounting for various piston-seal structures. A Genetic Algorithm is also applied to identify and optimize the parameters of the proposed friction model. Simulations with O-Ring, D-Ring, and Bonded Piston seals were developed to show the validity of the proposed model in practical scenarios. The results were also compared with the original Generalized Maxwell Slip friction model to show the superiority of the proposed model in representing the experimental data.
- Open Access
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 149520-149528
A Fault-Tolerant Control Approach Based on Image Processing Applied to Three-Tank System
This paper presents an innovative and practical solution for fault-tolerant control of industrial systems based on hybrid redundant measurements. The paper proposes a fault-tolerant control scheme against single and multiple sensor faults that can occur in typical tank-based industrial applications. A robust fault detection filter based on H-/H∞ index is designed to generate a residual signal that is robust against disturbance and sensitive to the fault, simultaneously. It also integrates camera information and image processing techniques in the control scheme to get level-measurement redundancy. The proposed scheme was tested using the well-known three-tank benchmark, with both offline and online computation. Results showed that the proposed scheme tolerated the sensor faults and preserved the correct operation of the tank levels in both single and multiple-sensor faults, without changing the original structure of the controller.
- 4 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 149520-149528
Open AccessA Fault-Tolerant Control Approach Based on Image Processing Applied to Three-Tank System
This paper presents an innovative and practical solution for fault-tolerant control of industrial systems based on hybrid redundant measurements. The paper proposes a fault-tolerant control scheme against single and multiple sensor faults that can occur in typical tank-based industrial applications. A robust fault detection filter based on H-/H∞ index is designed to generate a residual signal that is robust against disturbance and sensitive to the fault, simultaneously. It also integrates camera information and image processing techniques in the control scheme to get level-measurement redundancy. The proposed scheme was tested using the well-known three-tank benchmark, with both offline and online computation. Results showed that the proposed scheme tolerated the sensor faults and preserved the correct operation of the tank levels in both single and multiple-sensor faults, without changing the original structure of the controller.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Electrical Fault Detection in Three-Phase Induction Motor Based on Acoustics
This study presents the methodology for detecting single phasing fault of three-phase induction motors in steady-state operation based on acoustic sound signal analysis. In the proposed methodology, the signal analysis based on the Root Mean Square (RMS) parameter is used as a comparison between a healthy and a faulty motor in the time-domain. Whereas for the frequency-domain, the Fast Fourier Transform (FFT) with the Average power parameter is used. The hypothesis test is used to prove the statistical significance of the difference between the calculated parameters of the faulty and healthy three-phase induction motors. To illustrate the functionality of the proposed technique many tests have been carried out on a real machine. The results show that integrating motor sound with the traditional control system can increase the protection and reliability of three-phase induction motors.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Electrical Fault Detection in Three-Phase Induction Motor Based on Acoustics
This study presents the methodology for detecting single phasing fault of three-phase induction motors in steady-state operation based on acoustic sound signal analysis. In the proposed methodology, the signal analysis based on the Root Mean Square (RMS) parameter is used as a comparison between a healthy and a faulty motor in the time-domain. Whereas for the frequency-domain, the Fast Fourier Transform (FFT) with the Average power parameter is used. The hypothesis test is used to prove the statistical significance of the difference between the calculated parameters of the faulty and healthy three-phase induction motors. To illustrate the functionality of the proposed technique many tests have been carried out on a real machine. The results show that integrating motor sound with the traditional control system can increase the protection and reliability of three-phase induction motors.
- 1 October 2019
- Published by Taylor & Francis in International Journal of Computer Integrated Manufacturing
- Vol. 33 (6) , 531-549
Multiple-sensor fault detection and isolation using video processing in production lines
Production-line sensors are essential for synchronisation and execution of the correct workflow in a manufacturing process. Usually, sensor faults lead to serious delays, or even the complete termination of the manufacturing process, to carry out maintenance. Thus, sensor faults compromise the reliability of the manufacturing system and disturb the production schedule. This study proposes a multiple-sensor fault detection and isolation scheme for manufacturing series production lines. The proposed scheme adopts a global-redundancy method, using a digital camera and an ad-hoc video processing algorithm to detect and isolate faulty sensors. The main objective of this research is to preserve continuity of the production workflow and solve the problem of production delays and interruptions. Moreover, the scheme provides the possibility of online and post-process system maintenance. Further, the collected information on sensor false alarm rates can be used for a reliability analysis of the production line. The proposed scheme was tested using a laboratory production line model. The results show that the proposed scheme achieves the established objectives and improves the reliability of the manufacturing process.
- 1 October 2019
- Published by Taylor & Francis in International Journal of Computer Integrated Manufacturing
- Vol. 33 (6) , 531-549
Multiple-sensor fault detection and isolation using video processing in production lines
Production-line sensors are essential for synchronisation and execution of the correct workflow in a manufacturing process. Usually, sensor faults lead to serious delays, or even the complete termination of the manufacturing process, to carry out maintenance. Thus, sensor faults compromise the reliability of the manufacturing system and disturb the production schedule. This study proposes a multiple-sensor fault detection and isolation scheme for manufacturing series production lines. The proposed scheme adopts a global-redundancy method, using a digital camera and an ad-hoc video processing algorithm to detect and isolate faulty sensors. The main objective of this research is to preserve continuity of the production workflow and solve the problem of production delays and interruptions. Moreover, the scheme provides the possibility of online and post-process system maintenance. Further, the collected information on sensor false alarm rates can be used for a reliability analysis of the production line. The proposed scheme was tested using a laboratory production line model. The results show that the proposed scheme achieves the established objectives and improves the reliability of the manufacturing process.