Hakam Shehadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hakam Shehadeh has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jamal Siam
Department of Electrical and Computer Engineering, Birzeit University, Birzeit, Palestine
8 shared publications - Ali Abdo
Department of Electrical and Computer Engineering, Birzeit University, Birzeit, Palestine
7 shared publications - Eleonora Riva Sanseverino
Department of Engineering, University of Palermo, 90128 Palermo, Italy
3 shared publications - Rashad Mustafa
Department of Mechanical and Mechatronics Engineering, Faculty of Engineering and Technology, Birzeit University, Birzeit 9730000, Palestine
3 shared publications - Salvattore Favuzza
Department of Engineering, University of Palermo, 90128 Palermo, Italy
3 shared publications Ahmed Abdou
Electronic and Communication Engineering Department, Al-Quds University, Jerusalem, Palestine
2 shared publications
Latest Publications
- Open Access
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 20671-20680
Fault-Tolerant Control Strategies for Switching Motor Stator Windings Under Single Phasing
Single-phasing faults in three-phase induction motors can lead to a significant rise in stator winding temperatures, posing a risk of thermal damage and reduced motor lifespan. While the conventional response is to shut down the motor during such faults, this approach can disrupt industrial operations and critical services such as elevators, cooling, and ventilation systems. This research presents a practical and innovative fault tolerant control strategy that enables continued motor operation under single-phasing conditions without compromising reliability or longevity. The proposed method employs a switching technique to redistribute current flow within the stator windings, thereby mitigating overheating. A detailed thermal model is developed and analyzed to assess the temperature behavior and ensure effective protection of the motor. Experimental validation confirms that the control scheme maintains safe operating temperatures, allowing the motor to function efficiently during single-phasing. This solution offers a reliable alternative to shutdowns, enhancing the resilience and availability of three-phase induction motors in essential applications.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 20671-20680
Open AccessFault-Tolerant Control Strategies for Switching Motor Stator Windings Under Single Phasing
Single-phasing faults in three-phase induction motors can lead to a significant rise in stator winding temperatures, posing a risk of thermal damage and reduced motor lifespan. While the conventional response is to shut down the motor during such faults, this approach can disrupt industrial operations and critical services such as elevators, cooling, and ventilation systems. This research presents a practical and innovative fault tolerant control strategy that enables continued motor operation under single-phasing conditions without compromising reliability or longevity. The proposed method employs a switching technique to redistribute current flow within the stator windings, thereby mitigating overheating. A detailed thermal model is developed and analyzed to assess the temperature behavior and ensure effective protection of the motor. Experimental validation confirms that the control scheme maintains safe operating temperatures, allowing the motor to function efficiently during single-phasing. This solution offers a reliable alternative to shutdowns, enhancing the resilience and availability of three-phase induction motors in essential applications.
- Open Access
- 29 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4690
Practical Test on the Operation of the Three-Phase Induction Motor under Single-Phasing Fault
Single-phasing is a common problem in the three-phase electrical grid. Despite the fact that the fault occurs in one phasing, the three-phase load is affected, and therefore the load is typically turned off. The three-phase induction motor is the most commonly used in the industry; therefore, this research investigates the behavior of the three-phase induction motor under a single-phasing fault. The main aim of this paper is to answer the question, should the three-phase induction motor be turned off under a single-phasing fault? The problem is investigated theoretically and compared with practical tests to explore the parameters of the induction motor (current, stator temperature, and vibration) that are affected under healthy and single-phasing fault conditions. A practical test machine is built to test the motor behavior under single-phasing faults, where the practical experiment results are compared to those of the simulations. Despite the common recommendation under single-phasing fault is to turn off the induction motors, the preliminary results of this study show that turning off an induction motor under single-phasing can be avoided under certain operating conditions with a simple protection scheme, which is useful in some practical situations.
- 29 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4690
Open AccessPractical Test on the Operation of the Three-Phase Induction Motor under Single-Phasing Fault
Single-phasing is a common problem in the three-phase electrical grid. Despite the fact that the fault occurs in one phasing, the three-phase load is affected, and therefore the load is typically turned off. The three-phase induction motor is the most commonly used in the industry; therefore, this research investigates the behavior of the three-phase induction motor under a single-phasing fault. The main aim of this paper is to answer the question, should the three-phase induction motor be turned off under a single-phasing fault? The problem is investigated theoretically and compared with practical tests to explore the parameters of the induction motor (current, stator temperature, and vibration) that are affected under healthy and single-phasing fault conditions. A practical test machine is built to test the motor behavior under single-phasing faults, where the practical experiment results are compared to those of the simulations. Despite the common recommendation under single-phasing fault is to turn off the induction motors, the preliminary results of this study show that turning off an induction motor under single-phasing can be avoided under certain operating conditions with a simple protection scheme, which is useful in some practical situations.
- Open Access
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 128721-128731
Power Loss and Total Load Demand Coverage in Stand-Alone Microgrids: A Combined and Conventional Droop Control Perspectives
Conventional droop control plays an essential role in microgrids with distributed generators, DGs, and variable load demand. Despite its advantages, the conventional droop scheme does not take into account the minimization of power losses and the maximization of the total load coverage. Moreover, most of the nonconventional droop control studies that address power loss consider one variable load. This study proposes a combined droop scheme and inspects its effects on power loss minimization and total load coverage. The proposed scheme combines conventional and nonconventional droop schemes and constructs a 3D P-f droop characteristic that takes into account the presence of two variable loads. Four and six-bus microgrids are adopted to simulate and illustrate the system behavior in MatLab. Results are compared to the standard fully conventional droop approach; results showed that the combined scheme has higher performance in terms of power loss gain and total load coverage.
- 6 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 128721-128731
Open AccessPower Loss and Total Load Demand Coverage in Stand-Alone Microgrids: A Combined and Conventional Droop Control Perspectives
Conventional droop control plays an essential role in microgrids with distributed generators, DGs, and variable load demand. Despite its advantages, the conventional droop scheme does not take into account the minimization of power losses and the maximization of the total load coverage. Moreover, most of the nonconventional droop control studies that address power loss consider one variable load. This study proposes a combined droop scheme and inspects its effects on power loss minimization and total load coverage. The proposed scheme combines conventional and nonconventional droop schemes and constructs a 3D P-f droop characteristic that takes into account the presence of two variable loads. Four and six-bus microgrids are adopted to simulate and illustrate the system behavior in MatLab. Results are compared to the standard fully conventional droop approach; results showed that the combined scheme has higher performance in terms of power loss gain and total load coverage.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Electrical Fault Detection in Three-Phase Induction Motor Based on Acoustics
This study presents the methodology for detecting single phasing fault of three-phase induction motors in steady-state operation based on acoustic sound signal analysis. In the proposed methodology, the signal analysis based on the Root Mean Square (RMS) parameter is used as a comparison between a healthy and a faulty motor in the time-domain. Whereas for the frequency-domain, the Fast Fourier Transform (FFT) with the Average power parameter is used. The hypothesis test is used to prove the statistical significance of the difference between the calculated parameters of the faulty and healthy three-phase induction motors. To illustrate the functionality of the proposed technique many tests have been carried out on a real machine. The results show that integrating motor sound with the traditional control system can increase the protection and reliability of three-phase induction motors.
- 1 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Electrical Fault Detection in Three-Phase Induction Motor Based on Acoustics
This study presents the methodology for detecting single phasing fault of three-phase induction motors in steady-state operation based on acoustic sound signal analysis. In the proposed methodology, the signal analysis based on the Root Mean Square (RMS) parameter is used as a comparison between a healthy and a faulty motor in the time-domain. Whereas for the frequency-domain, the Fast Fourier Transform (FFT) with the Average power parameter is used. The hypothesis test is used to prove the statistical significance of the difference between the calculated parameters of the faulty and healthy three-phase induction motors. To illustrate the functionality of the proposed technique many tests have been carried out on a real machine. The results show that integrating motor sound with the traditional control system can increase the protection and reliability of three-phase induction motors.
- 3 June 2019
- Published by Springer Nature in International Journal on Interactive Design and Manufacturing (IJIDeM)
- Vol. 13 (4) , 1579-1586
Residual-signal generation for vehicle lateral dynamics disturbances: a switched-observers approach
- 3 June 2019
- Published by Springer Nature in International Journal on Interactive Design and Manufacturing (IJIDeM)
- Vol. 13 (4) , 1579-1586
Residual-signal generation for vehicle lateral dynamics disturbances: a switched-observers approach
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Approach for Fault Detection and Fault Tolerant Control of Wind Turbines
This paper presents an efficient technique for monitoring and control of wind turbines. Fault tolerant control (FTC) is designed using Parity-Space approach to diagnose the sensor faults in the wind turbine. Based on the fault detection system an FTC scheme is proposed to accommodate and reconfigurable the control signals. The main contribution of this study is to develop a monitoring and control system of wind turbine, which reduces the system components as well as to increase the reliability and safety of wind turbines. The sensors which considered in this study are pitch position, generator speed and rotor speed sensors. Real data of wind measurement and real parameters of wind turbine is used to illustrate the proposed scheme.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Approach for Fault Detection and Fault Tolerant Control of Wind Turbines
This paper presents an efficient technique for monitoring and control of wind turbines. Fault tolerant control (FTC) is designed using Parity-Space approach to diagnose the sensor faults in the wind turbine. Based on the fault detection system an FTC scheme is proposed to accommodate and reconfigurable the control signals. The main contribution of this study is to develop a monitoring and control system of wind turbine, which reduces the system components as well as to increase the reliability and safety of wind turbines. The sensors which considered in this study are pitch position, generator speed and rotor speed sensors. Real data of wind measurement and real parameters of wind turbine is used to illustrate the proposed scheme.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fault Tolerant Control of an Industrial Manufacturing Process Using Image Processing
This paper proposes a fault-tolerant control technique, for industrial applications, based on image processing. It is known that, sensor faults disturb the normal sequences of manufacturing operations. This causes a serious delay in the manufacturing process, or even it terminated for maintenance. Cameras with ad-hoc video and image processing algorithms can be used to detect and track objects, thus they can play the role of sensors in industrial application. The proposed technique uses visual information, collected by cameras, to raise the fault-tolerant of the manufacturing system. The visual information is used to generate a redundant sensing signal to substitute the faulty-sensor signal in case of faults. The main advantages of the proposed technique are: the continuity throughout the manufacturing process as well as the detection and isolation of faulty-sensors. The proposed technique was applied to a real production line model to illustrate its performance.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fault Tolerant Control of an Industrial Manufacturing Process Using Image Processing
This paper proposes a fault-tolerant control technique, for industrial applications, based on image processing. It is known that, sensor faults disturb the normal sequences of manufacturing operations. This causes a serious delay in the manufacturing process, or even it terminated for maintenance. Cameras with ad-hoc video and image processing algorithms can be used to detect and track objects, thus they can play the role of sensors in industrial application. The proposed technique uses visual information, collected by cameras, to raise the fault-tolerant of the manufacturing system. The visual information is used to generate a redundant sensing signal to substitute the faulty-sensor signal in case of faults. The main advantages of the proposed technique are: the continuity throughout the manufacturing process as well as the detection and isolation of faulty-sensors. The proposed technique was applied to a real production line model to illustrate its performance.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Nonlinear droop control for minimum power losses operation in islanded microgrids
In this work, a modified primary regulation technique is proposed to control one of the inverter interfaced units feeding an islanded microgrid. The proposed approach employs an off-line minimum losses Optimal Power Flow, OPF, to extract a lookup table for the composition of the droop curve. Simulations prove that generators reach an operating point that corresponds to a minimum loss operation for the relevant power flow distribution. Since OPF has been implemented with frequency and voltage dependent models, the results of the modified droop are stable and also energy efficient. Further studies will address further analysis on systems showing different R/X ratio and modeling of more generators using the modified droop control.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Nonlinear droop control for minimum power losses operation in islanded microgrids
In this work, a modified primary regulation technique is proposed to control one of the inverter interfaced units feeding an islanded microgrid. The proposed approach employs an off-line minimum losses Optimal Power Flow, OPF, to extract a lookup table for the composition of the droop curve. Simulations prove that generators reach an operating point that corresponds to a minimum loss operation for the relevant power flow distribution. Since OPF has been implemented with frequency and voltage dependent models, the results of the modified droop are stable and also energy efficient. Further studies will address further analysis on systems showing different R/X ratio and modeling of more generators using the modified droop control.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mathematical modelling of an inverter-based distributed generator
In this paper, a modeling approach of a three phase power inverter based on an electrostatic synchronous machine is presented. By the proposed approach, any inverter-based distributed generator in a microgrid can be replaced by an equivalent electrostatic machine. This paper aims to promote the use of the proposed modeling approach in the analysis of microgrid stability. Thanks to the proposed modeling approach, transient performances of on-grid operation of converter-based distributed generators could be easily analyzed by multi-machine models. Parameters of the equivalent synchronous electrostatic machine model are derived to achieve equivalence with the inverter model. Small signal models in the d-q synchronous reference frame of both the inverter and the machine are compared. An integrated simulation setup including the electrical power inverter with a sinusoidal Pulse Width Modulation scheme and the small signal models of both the inverter and the electrostatic machine is implemented. Simulation results are shown to validate the modeling approach.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mathematical modelling of an inverter-based distributed generator
In this paper, a modeling approach of a three phase power inverter based on an electrostatic synchronous machine is presented. By the proposed approach, any inverter-based distributed generator in a microgrid can be replaced by an equivalent electrostatic machine. This paper aims to promote the use of the proposed modeling approach in the analysis of microgrid stability. Thanks to the proposed modeling approach, transient performances of on-grid operation of converter-based distributed generators could be easily analyzed by multi-machine models. Parameters of the equivalent synchronous electrostatic machine model are derived to achieve equivalence with the inverter model. Small signal models in the d-q synchronous reference frame of both the inverter and the machine are compared. An integrated simulation setup including the electrical power inverter with a sinusoidal Pulse Width Modulation scheme and the small signal models of both the inverter and the electrostatic machine is implemented. Simulation results are shown to validate the modeling approach.