Bin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bin Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ming Ren
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Chenxi Guo
State Key Laboratory of Electrical Insulation for Power Equipment Xi'an Jiaotong University Xianning Road 28th Xi'an People's Republic of China
2 shared publications - Ming Dong
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Ricardo Albarracín
Universidad Politécnica de Madrid
2 shared publications - Chongxing Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
1 shared publication - Chunling Wu
School of Energy and Electrical Engineering, Chang’an University, Xi’an 710064, China
1 shared publication
Latest Publications
- 17 February 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 84, 110711
Automatically constructing a health indicator for lithium-ion battery state-of-health estimation via adversarial and compound staked autoencoder
- 17 February 2024
- Published by Elsevier in Journal of Energy Storage
- Vol. 84, 110711
Automatically constructing a health indicator for lithium-ion battery state-of-health estimation via adversarial and compound staked autoencoder
- Open Access
- 22 April 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (11) , 2202-2208
Transformer failure diagnosis using fuzzy association rule mining combined with case‐based reasoning
In the field of transformer failure diagnosis, the potential correlation between different characteristic parameters and failures is difficult to detect using traditional methods. Further, the quantities of inspection data have not been fully utilized. To improve the accuracy of transformer diagnosis, this study establishes a diagnosis model based on fuzzy association rules combined with case‐based reasoning (CBR) to evaluate the failure types, fault locations, and cause of breakdown in power transformers. First, the inspection data of transformers are collected from several substations over 10 years. Then, the pre‐processed data are randomly separated into training and testing sets. For the training set, fuzzy association rules are built for multiple parameters to narrow the search scope of base case preliminarily. Next, CBR is applied to determine the most similar cases. The failure information of the target transformer can be obtained in detail along with the most similar base case. Finally, the accuracy of the model is validated shown in case studies using the testing data set. The result demonstrates that the diagnosis model provides a higher accuracy than the classic IEC 60599 three‐ratio method used in the current industry, which means that this diagnosis model has better performance on diagnosis accuracy.
- 22 April 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (11) , 2202-2208
Open AccessTransformer failure diagnosis using fuzzy association rule mining combined with case‐based reasoning
In the field of transformer failure diagnosis, the potential correlation between different characteristic parameters and failures is difficult to detect using traditional methods. Further, the quantities of inspection data have not been fully utilized. To improve the accuracy of transformer diagnosis, this study establishes a diagnosis model based on fuzzy association rules combined with case‐based reasoning (CBR) to evaluate the failure types, fault locations, and cause of breakdown in power transformers. First, the inspection data of transformers are collected from several substations over 10 years. Then, the pre‐processed data are randomly separated into training and testing sets. For the training set, fuzzy association rules are built for multiple parameters to narrow the search scope of base case preliminarily. Next, CBR is applied to determine the most similar cases. The failure information of the target transformer can be obtained in detail along with the most similar base case. Finally, the accuracy of the model is validated shown in case studies using the testing data set. The result demonstrates that the diagnosis model provides a higher accuracy than the classic IEC 60599 three‐ratio method used in the current industry, which means that this diagnosis model has better performance on diagnosis accuracy.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (8) , 5345-5355
Automatic Fault Diagnosis of Infrared Insulator Images Based on Image Instance Segmentation and Temperature Analysis
As an onsite condition monitoring method, infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. To improve the efficiency of onsite diagnosis of insulators in substations, this paper proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. To develop this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of Mask R-CNN it was possible to extract multiple insulators automatically in the infrared images. Transfer learning as well as the dynamic learning rate algorithm were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mAP of the model is 0.77 and the FPS is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (8) , 5345-5355
Automatic Fault Diagnosis of Infrared Insulator Images Based on Image Instance Segmentation and Temperature Analysis
As an onsite condition monitoring method, infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. To improve the efficiency of onsite diagnosis of insulators in substations, this paper proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. To develop this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of Mask R-CNN it was possible to extract multiple insulators automatically in the infrared images. Transfer learning as well as the dynamic learning rate algorithm were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mAP of the model is 0.77 and the FPS is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1221-1229
Joint Visualization Diagnosis of Outdoor Insulation Status With Optical and Acoustical Detections
This paper proposes a joint visualization detection method to diagnose outdoor insulation status of high-voltage (HV) equipment in substations, which applies image matching and fusion techniques to accurately combine the results of ultrasonic, ultraviolet, and infrared detection in an image. This image can then be used to quickly and clearly locate the region of corona discharge and overheating of outdoor substation HV equipment. First, ultrasonic localization visualization of corona discharge is proposed, which is based on the designed double-helix array and multi-signal classification algorithm. This method provides a more intuitive way for the diagnosis of outdoor insulation status. Then, ultraviolet localization visualization method is detailed, and an adaptive affine matrix is designed for the accurate location of corona discharge. Following this, infrared-visible detection of overheating failure is introduced, and the speeded-up robust features (SURF) algorithm and random sample consensus (RANSAC) algorithm are used to implement image fusion process. Finally, the results of image fusion are provided, and location error evaluations are conducted for each module. With acceptable cost and advantages of three detection method, the proposed visualization method is used for evaluating the insulation status of substation equipment more intuitively and conveniently, and thus has an extensive application prospect.
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1221-1229
Joint Visualization Diagnosis of Outdoor Insulation Status With Optical and Acoustical Detections
This paper proposes a joint visualization detection method to diagnose outdoor insulation status of high-voltage (HV) equipment in substations, which applies image matching and fusion techniques to accurately combine the results of ultrasonic, ultraviolet, and infrared detection in an image. This image can then be used to quickly and clearly locate the region of corona discharge and overheating of outdoor substation HV equipment. First, ultrasonic localization visualization of corona discharge is proposed, which is based on the designed double-helix array and multi-signal classification algorithm. This method provides a more intuitive way for the diagnosis of outdoor insulation status. Then, ultraviolet localization visualization method is detailed, and an adaptive affine matrix is designed for the accurate location of corona discharge. Following this, infrared-visible detection of overheating failure is introduced, and the speeded-up robust features (SURF) algorithm and random sample consensus (RANSAC) algorithm are used to implement image fusion process. Finally, the results of image fusion are provided, and location error evaluations are conducted for each module. With acceptable cost and advantages of three detection method, the proposed visualization method is used for evaluating the insulation status of substation equipment more intuitively and conveniently, and thus has an extensive application prospect.