Jordan D. Skelly
Jordan D. Skelly has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jie Song
Department of Orthopedics and Physical Rehabilitation, Department of Biochemistry and Molecular Biotechnology, University of Massachusetts Chan Medical School, 55 Lake Avenue North, Worcester, Massachusetts 01655, United States
4 shared publications David C. Ayers
Department of Orthopedics and Physical Rehabilitation, UMass Chan Medical School, 55 Lake Avenue North, Worcester, Massachusetts 01655, United States
2 shared publications- Feiyang Chen
Chemistry Department
2 shared publications - Shing-Yun Chang
Department of Orthopedics & Physical Rehabilitation, Department of Biochemistry & Molecular Biotechnology, UMass Chan Medical School, 55 Lake Avenue North, Worcester, Massachusetts 01655, United States
2 shared publications Ananta Ghimire
Department of Orthopedics and Physical Rehabilitation, UMass Chan Medical School, 55 Lake Avenue North, Worcester, Massachusetts 01655, United States
1 shared publication- Ben Zhang
Sinopec Key Laboratory of Research and Application of Medical and Hygienic Materials Sinopec (Beijing) Research Institute of Chemical Industry Co., Ltd., 14 Beisanhuan East Road, Chao Yang District, Beijing 100013, P. R. China
1 shared publication
Latest Publications
- 31 March 2026
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 12 (4) , 1434-1447
Modulating Micrococcal Nuclease-Triggered Antibiotic Releases for One-Stage Revisions of Staphylococcus aureus -Infected Prostheses
Periprosthetic joint infections caused by Staphylococcus aureus (S. aureus) pose significant health risks and economic burdens. Following revisions of infected arthroplasty prostheses, the reinfection rate can be as high as 30%. We previously developed hydrogel coatings for intramedullary metallic pins where vancomycin or ampicillin was covalently attached through an oligonucleotide linker cleavable by micrococcal nuclease secreted by S. aureus. When these pins were implanted in S. aureus-inoculated rat femoral canals, the on-demand release of antibiotics from the coating prevented infections from developing. Here, we test the hypothesis that a combination coating with rapid and more sustained S. aureus-triggered antibiotic releases could mitigate infections following one-stage revisions of previously infected prostheses. We implemented varying degrees of phosphorothioate modification of the oligonucleotide linker tethering ampicillin to the coating to achieve rapid and more sustained on-demand antibiotic releases. We first demonstrated that rat femoral infections, established by the inoculation of 200 CFU S. aureus at the time of uncoated primary intramedullary pin insertion, could not be resolved after one-stage revision without a proper pin coating, consistent with clinically observed challenges. However, bacterial burdens were significantly reduced following a one-stage revision with intramedullary pins coated with ampicillin-releasing coatings, with the combination of rapid and more sustained releases proving the most effective. When the combination coating was augmented with a single systemic vancomycin injection at the time of revision, infection was eradicated, outperforming local or systemic treatment alone and achieving unprecedented revision outcomes.
- 31 March 2026
- Published by American Chemical Society (ACS) in ACS Infectious Diseases
- Vol. 12 (4) , 1434-1447
Modulating Micrococcal Nuclease-Triggered Antibiotic Releases for One-Stage Revisions of Staphylococcus aureus -Infected Prostheses
Periprosthetic joint infections caused by Staphylococcus aureus (S. aureus) pose significant health risks and economic burdens. Following revisions of infected arthroplasty prostheses, the reinfection rate can be as high as 30%. We previously developed hydrogel coatings for intramedullary metallic pins where vancomycin or ampicillin was covalently attached through an oligonucleotide linker cleavable by micrococcal nuclease secreted by S. aureus. When these pins were implanted in S. aureus-inoculated rat femoral canals, the on-demand release of antibiotics from the coating prevented infections from developing. Here, we test the hypothesis that a combination coating with rapid and more sustained S. aureus-triggered antibiotic releases could mitigate infections following one-stage revisions of previously infected prostheses. We implemented varying degrees of phosphorothioate modification of the oligonucleotide linker tethering ampicillin to the coating to achieve rapid and more sustained on-demand antibiotic releases. We first demonstrated that rat femoral infections, established by the inoculation of 200 CFU S. aureus at the time of uncoated primary intramedullary pin insertion, could not be resolved after one-stage revision without a proper pin coating, consistent with clinically observed challenges. However, bacterial burdens were significantly reduced following a one-stage revision with intramedullary pins coated with ampicillin-releasing coatings, with the combination of rapid and more sustained releases proving the most effective. When the combination coating was augmented with a single systemic vancomycin injection at the time of revision, infection was eradicated, outperforming local or systemic treatment alone and achieving unprecedented revision outcomes.
- 1 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (19) , 24421-24430
Triggered Release of Ampicillin from Metallic Implant Coatings for Combating Periprosthetic Infections
Periprosthetic infections caused by Staphylococcus aureus (S. aureus) pose unique challenges in orthopedic surgeries, in part due to the bacterium's capacity to invade surrounding bone tissues besides forming recalcitrant biofilms on implant surfaces. We previously developed prophylactic implant coatings for the on-demand release of vancomycin, triggered by the cleavage of an oligonucleotide (Oligo) linker by micrococcal nuclease (MN) secreted by the Gram-positive bacterium, to eradicate S. aureus surrounding the implant in vitro and in vivo. Building upon this coating platform, here we explore the feasibility of extending the on-demand release to ampicillin, a broad-spectrum aminopenicillin β-lactam antibiotic that is more effective than vancomycin in killing Gram-negative bacteria that may accompany S. aureus infections. The amino group of ampicillin was successfully conjugated to the carboxyl end of an MN-sensitive Oligo covalently integrated in a polymethacrylate hydrogel coating applied to titanium alloy pins. The resultant Oligo-Ampicillin hydrogel coating released the β-lactam in the presence of S. aureus and successfully cleared nearby S. aureus in vitro. When the Oligo-Ampicillin-coated pin was delivered to a rat femoral canal inoculated with 1000 cfu S. aureus, it prevented periprosthetic infection with timely on-demand drug release. The clearance of the bacteria from the pin surface as well as surrounding tissue persisted over 3 months, with no local or systemic toxicity observed with the coating. The negatively charged Oligo fragment attached to ampicillin upon cleavage from the coating did diminish the antibiotic's potency against S. aureus and Escherichia coli (E. coli) to varying degrees, likely due to electrostatic repulsion by the anionic surfaces of the bacteria. Although the on-demand release of the β-lactam led to adequate killing of S. aureus but not E. coli in the presence of a mixture of the bacteria, strong inhibition of the colonization of the remaining E. coli on hydrogel coating was observed. These findings will inspire considerations of alternative broad-spectrum antibiotics, optimized drug conjugation, and Oligo linker engineering for more effective protection against polymicrobial periprosthetic infections.
- 1 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (19) , 24421-24430
Triggered Release of Ampicillin from Metallic Implant Coatings for Combating Periprosthetic Infections
Periprosthetic infections caused by Staphylococcus aureus (S. aureus) pose unique challenges in orthopedic surgeries, in part due to the bacterium's capacity to invade surrounding bone tissues besides forming recalcitrant biofilms on implant surfaces. We previously developed prophylactic implant coatings for the on-demand release of vancomycin, triggered by the cleavage of an oligonucleotide (Oligo) linker by micrococcal nuclease (MN) secreted by the Gram-positive bacterium, to eradicate S. aureus surrounding the implant in vitro and in vivo. Building upon this coating platform, here we explore the feasibility of extending the on-demand release to ampicillin, a broad-spectrum aminopenicillin β-lactam antibiotic that is more effective than vancomycin in killing Gram-negative bacteria that may accompany S. aureus infections. The amino group of ampicillin was successfully conjugated to the carboxyl end of an MN-sensitive Oligo covalently integrated in a polymethacrylate hydrogel coating applied to titanium alloy pins. The resultant Oligo-Ampicillin hydrogel coating released the β-lactam in the presence of S. aureus and successfully cleared nearby S. aureus in vitro. When the Oligo-Ampicillin-coated pin was delivered to a rat femoral canal inoculated with 1000 cfu S. aureus, it prevented periprosthetic infection with timely on-demand drug release. The clearance of the bacteria from the pin surface as well as surrounding tissue persisted over 3 months, with no local or systemic toxicity observed with the coating. The negatively charged Oligo fragment attached to ampicillin upon cleavage from the coating did diminish the antibiotic's potency against S. aureus and Escherichia coli (E. coli) to varying degrees, likely due to electrostatic repulsion by the anionic surfaces of the bacteria. Although the on-demand release of the β-lactam led to adequate killing of S. aureus but not E. coli in the presence of a mixture of the bacteria, strong inhibition of the colonization of the remaining E. coli on hydrogel coating was observed. These findings will inspire considerations of alternative broad-spectrum antibiotics, optimized drug conjugation, and Oligo linker engineering for more effective protection against polymicrobial periprosthetic infections.
- 31 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (31) , 37174-37183
Modulating On-Demand Release of Vancomycin from Implant Coatings via Chemical Modification of a Micrococcal Nuclease-Sensitive Oligonucleotide Linker
Periprosthetic infections are one of the most serious complications in orthopedic surgeries, and those caused by Staphylococcus aureus (S. aureus) are particularly hard to treat due to their tendency to form biofilms on implants and their notorious ability to invade the surrounding bones. The existing prophylactic local antibiotic deliveries involve excessive drug loading doses that could risk the development of drug resistance strains. Utilizing an oligonucleotide linker sensitive to micrococcal nuclease (MN) cleavage, we previously developed an implant coating capable of releasing covalently tethered vancomycin, triggered by S. aureus-secreted MN, to prevent periprosthetic infections in the mouse intramedullary (IM) canal. To further engineer this exciting platform to meet broader clinical needs, here, we chemically modified the oligonucleotide linker by a combination of 2'-O-methylation and phosphorothioate modification to achieve additional modulation of its stability/sensitivity to MN and the kinetics of MN-triggered on-demand release. We found that when all phosphodiester bonds within the oligonucleotide linker 5'-carboxy-mCmGTTmCmG-3-acrydite, except for the one between TT, were replaced by phosphorothioate, the oligonucleotide (6PS) stability significantly increased and enabled the most sustained release of tethered vancomycin from the coating. By contrast, when only the peripheral phosphodiester bonds at the 5'- and 3'-ends were replaced by phosphorothioate, the resulting oligonucleotide (2PS) linker was cleaved by MN more rapidly than that without any PS modifications (0PS). Using a rat femoral canal periprosthetic infection model where 1000 CFU S. aureus was inoculated at the time of IM pin insertion, we showed that the prophylactic implant coating containing either 0PS- or 2PS-modified oligonucleotide linker effectively eradicated the bacteria by enabling the rapid on-demand release of vancomycin. No bacteria were detected from the explanted pins, and no signs of cortical bone changes were detected in these treatment groups throughout the 3 month follow-ups. With an antibiotic tethering dose significantly lower than conventional antibiotic-bearing bone cements, these coatings also exhibited excellent biocompatibility. These chemically modified oligonucleotides could help tailor prophylactic anti-infective coating strategies to meet a range of clinical challenges where the risks for S. aureus prosthetic infections range from transient to long-lasting.
- 31 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (31) , 37174-37183
Modulating On-Demand Release of Vancomycin from Implant Coatings via Chemical Modification of a Micrococcal Nuclease-Sensitive Oligonucleotide Linker
Periprosthetic infections are one of the most serious complications in orthopedic surgeries, and those caused by Staphylococcus aureus (S. aureus) are particularly hard to treat due to their tendency to form biofilms on implants and their notorious ability to invade the surrounding bones. The existing prophylactic local antibiotic deliveries involve excessive drug loading doses that could risk the development of drug resistance strains. Utilizing an oligonucleotide linker sensitive to micrococcal nuclease (MN) cleavage, we previously developed an implant coating capable of releasing covalently tethered vancomycin, triggered by S. aureus-secreted MN, to prevent periprosthetic infections in the mouse intramedullary (IM) canal. To further engineer this exciting platform to meet broader clinical needs, here, we chemically modified the oligonucleotide linker by a combination of 2'-O-methylation and phosphorothioate modification to achieve additional modulation of its stability/sensitivity to MN and the kinetics of MN-triggered on-demand release. We found that when all phosphodiester bonds within the oligonucleotide linker 5'-carboxy-mCmGTTmCmG-3-acrydite, except for the one between TT, were replaced by phosphorothioate, the oligonucleotide (6PS) stability significantly increased and enabled the most sustained release of tethered vancomycin from the coating. By contrast, when only the peripheral phosphodiester bonds at the 5'- and 3'-ends were replaced by phosphorothioate, the resulting oligonucleotide (2PS) linker was cleaved by MN more rapidly than that without any PS modifications (0PS). Using a rat femoral canal periprosthetic infection model where 1000 CFU S. aureus was inoculated at the time of IM pin insertion, we showed that the prophylactic implant coating containing either 0PS- or 2PS-modified oligonucleotide linker effectively eradicated the bacteria by enabling the rapid on-demand release of vancomycin. No bacteria were detected from the explanted pins, and no signs of cortical bone changes were detected in these treatment groups throughout the 3 month follow-ups. With an antibiotic tethering dose significantly lower than conventional antibiotic-bearing bone cements, these coatings also exhibited excellent biocompatibility. These chemically modified oligonucleotides could help tailor prophylactic anti-infective coating strategies to meet a range of clinical challenges where the risks for S. aureus prosthetic infections range from transient to long-lasting.
- 24 July 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (502)
Multifunctional scaffolds for facile implantation, spontaneous fixation, and accelerated long bone regeneration in rodents
Self-stiffening, macroporous, shape-memory scaffolds delivering a low dose of osteogenic factors accelerate segmental long bone regeneration in rats.
- 24 July 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 11 (502)
Multifunctional scaffolds for facile implantation, spontaneous fixation, and accelerated long bone regeneration in rodents
Self-stiffening, macroporous, shape-memory scaffolds delivering a low dose of osteogenic factors accelerate segmental long bone regeneration in rats.