Fatima Hameed Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fatima Hameed Khan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Wala Saadeh
Electrical Engineering Department, Western Washington University, Bellingham, WA, USA
2 shared publications Amer Yaqub
The Eye Consultants, Rawalpindi Pakistan
1 shared publicationAmjad Akram
Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Pakistan
1 shared publicationAmmara Ashraf
Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Pakistan
1 shared publication- Muhammad Awais Bin Altaf
Department of Electrical and Computer Engineering, Western Washington University, Bellingham, WA 98225, USA
1 shared publication Shafaq Rabbani
Armed Forces Institute of Ophthalmology/National University of Medical Sciences (NUMS) Pakistan
1 shared publication
Latest Publications
- Open Access
- 31 May 2022
- Published by Army Medical College in Pakistan Armed Forces Medical Journal
- Vol. 72 (SUPPL-2) , S293-96
Comparison of Biometric Parameters and the Level of Agreement Between OB820 and Iol Master
Objective: The primary aim of this study was measure and compare the axial length (AXL), keratometric indices (K1, K2) and anterior chamber depth (ACD) by biometric devices; IOL Master and OB 820, to seek evidence on level of agreement for these parameters between these two devices. Study Design: Quasi-experimental study. Place and Duration of Study: Armed Forces Institute of Ophthalmology, Rawalpindi Pakistan, from Jul 2016 to Apr 2018. Methodology: This study was carried out at Armed Forced Institute of Ophthalmology on seventy eyes of 53 patients with senile grade II and grade III cataract. All patients underwent comprehensive ophthalmic and biometric examination using two different optical biometry devices the IOL-Master (Carl Zeiss Meditec, Jena, Germany) and OB-820 (Wave Light, Germany). Parameters of study were axial length (AXL), kera to metric indices (K1, K2) and anterior chamber depth (ACD). The results were evaluated using Bland–Altman analyses for level of agreement (LoA). The differences between both methodologies were assessed using the paired samples t test, and their correlation was evaluated by intra class correlation coefficient (ICC). Results: The mean age was 62.97 ± 7.97 years with the male/female ratio of 28/25. Mean axial length assessed by OB820 and IOL Master differed significantly in two groups, with a p-value of 0.018. Bland-Altman analysis further confirm significant difference range and 95% limits of agreement and ICC=0.659) of agreement for AXL. While, other parameters, K1, K2 and ACD showed an outstanding agreement (range within 95% confidence interval by Bland -Altman analysis) and internal consistency and.................
- 31 May 2022
- Published by Army Medical College in Pakistan Armed Forces Medical Journal
- Vol. 72 (SUPPL-2) , S293-96
Open AccessComparison of Biometric Parameters and the Level of Agreement Between OB820 and Iol Master
Objective: The primary aim of this study was measure and compare the axial length (AXL), keratometric indices (K1, K2) and anterior chamber depth (ACD) by biometric devices; IOL Master and OB 820, to seek evidence on level of agreement for these parameters between these two devices. Study Design: Quasi-experimental study. Place and Duration of Study: Armed Forces Institute of Ophthalmology, Rawalpindi Pakistan, from Jul 2016 to Apr 2018. Methodology: This study was carried out at Armed Forced Institute of Ophthalmology on seventy eyes of 53 patients with senile grade II and grade III cataract. All patients underwent comprehensive ophthalmic and biometric examination using two different optical biometry devices the IOL-Master (Carl Zeiss Meditec, Jena, Germany) and OB-820 (Wave Light, Germany). Parameters of study were axial length (AXL), kera to metric indices (K1, K2) and anterior chamber depth (ACD). The results were evaluated using Bland–Altman analyses for level of agreement (LoA). The differences between both methodologies were assessed using the paired samples t test, and their correlation was evaluated by intra class correlation coefficient (ICC). Results: The mean age was 62.97 ± 7.97 years with the male/female ratio of 28/25. Mean axial length assessed by OB820 and IOL Master differed significantly in two groups, with a p-value of 0.018. Bland-Altman analysis further confirm significant difference range and 95% limits of agreement and ICC=0.659) of agreement for AXL. While, other parameters, K1, K2 and ACD showed an outstanding agreement (range within 95% confidence interval by Bland -Altman analysis) and internal consistency and.................
- 23 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 29 (5) , 950-961
An EEG-Based Hypnotic State Monitor for Patients During General Anesthesia
Most surgical procedures are not possible without general anesthesia which necessitates continuous and accurate monitoring of the patients' level of hypnosis (LoH). Currently, the LoH is monitored using the conventional methods of either observing the patient's physiological parameters or using electroencephalogram (EEG)-based monitors. To overcome the limitations of the conventional methods, this work implements an accurate EEG-based LoH monitoring processor using a bagged tree machine-learning (BTML) classifier. It is based on 12 temporal and spectral features to incorporate robustness against age variation and achieve high classification accuracy. Spectral features are computed using discrete wavelet transform (DWT) that uses time-multiplexed filter (TMF) architecture. The TMF DWT consumes 110.6-nJ/feature vector for a 100-tap filter while reducing the area by 11% compared with the conventional method. Moreover, the BTML is implemented using a pipelined approach which enables an efficient on-chip implementation to reduce the hardware cost by 15x compared with the parallel approach. The proposed processor is implemented using a 180-nm CMOS process with an active area of 0.9 mm² while consuming 1.6 mW. The accuracy of the proposed hypnotic state monitor is verified using two EEG databases with a total of 95 patients and achieves a sensitivity and specificity of 95.4% and 97.7%, respectively.
- 23 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 29 (5) , 950-961
An EEG-Based Hypnotic State Monitor for Patients During General Anesthesia
Most surgical procedures are not possible without general anesthesia which necessitates continuous and accurate monitoring of the patients' level of hypnosis (LoH). Currently, the LoH is monitored using the conventional methods of either observing the patient's physiological parameters or using electroencephalogram (EEG)-based monitors. To overcome the limitations of the conventional methods, this work implements an accurate EEG-based LoH monitoring processor using a bagged tree machine-learning (BTML) classifier. It is based on 12 temporal and spectral features to incorporate robustness against age variation and achieve high classification accuracy. Spectral features are computed using discrete wavelet transform (DWT) that uses time-multiplexed filter (TMF) architecture. The TMF DWT consumes 110.6-nJ/feature vector for a 100-tap filter while reducing the area by 11% compared with the conventional method. Moreover, the BTML is implemented using a pipelined approach which enables an efficient on-chip implementation to reduce the hardware cost by 15x compared with the parallel approach. The proposed processor is implemented using a 180-nm CMOS process with an active area of 0.9 mm² while consuming 1.6 mW. The accuracy of the proposed hypnotic state monitor is verified using two EEG databases with a total of 95 patients and achieves a sensitivity and specificity of 95.4% and 97.7%, respectively.
- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (4) , 658-669
Design and Implementation of a Machine Learning Based EEG Processor for Accurate Estimation of Depth of Anesthesia
Accurate monitoring of the depth of anesthesia (DoA) is essential for intraoperative and postoperative patient's health. Commercially available electroencephalograph (EEG)-based DoA monitors are recommended only for certain anesthetic drugs and specific age-group patients. This paper presents a machine learning classification processor for accurate DoA estimation irrespective of the patient's age and anesthetic drug. The classification is solely based on six features extracted from EEG signal, i.e. spectral edge frequency (SEF), beta ratio, and four bands of spectral energy (FBSE). A machine learning fine decision tree classifier is adopted to achieve a four-class DoA classification (deep, moderate, and light DoA versus awake state). The feature selection and the classification processor are optimized to achieve the highest classification accuracy for the state of moderate anesthesia required for the surgical operations. The proposed 256-point Fast Fourier Transform (FFT) accelerator is implemented to realize SEF, beta ratio and FBSE that enables minimal latency and high accuracy feature extraction. The proposed DoA processor is implemented using a 65nm CMOS technology and experimentally verified using FPGA based on the EEG recordings of 75 patients undergoing elective surgery with different types of anesthetic agents. The processor achieves an average accuracy of 92.2% for all DoA states, with a latency of 1 sec. The 0.09mm $^2$ DoA processor consumes 140nJ/classification.- 10 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (4) , 658-669
Design and Implementation of a Machine Learning Based EEG Processor for Accurate Estimation of Depth of Anesthesia
Accurate monitoring of the depth of anesthesia (DoA) is essential for intraoperative and postoperative patient's health. Commercially available electroencephalograph (EEG)-based DoA monitors are recommended only for certain anesthetic drugs and specific age-group patients. This paper presents a machine learning classification processor for accurate DoA estimation irrespective of the patient's age and anesthetic drug. The classification is solely based on six features extracted from EEG signal, i.e. spectral edge frequency (SEF), beta ratio, and four bands of spectral energy (FBSE). A machine learning fine decision tree classifier is adopted to achieve a four-class DoA classification (deep, moderate, and light DoA versus awake state). The feature selection and the classification processor are optimized to achieve the highest classification accuracy for the state of moderate anesthesia required for the surgical operations. The proposed 256-point Fast Fourier Transform (FFT) accelerator is implemented to realize SEF, beta ratio and FBSE that enables minimal latency and high accuracy feature extraction. The proposed DoA processor is implemented using a 65nm CMOS technology and experimentally verified using FPGA based on the EEG recordings of 75 patients undergoing elective surgery with different types of anesthetic agents. The processor achieves an average accuracy of 92.2% for all DoA states, with a latency of 1 sec. The 0.09mm $^2$ DoA processor consumes 140nJ/classification.