Feng Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Feng Hong has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Baojian Ji
Nanjing University of Science and Technology, Nanjing, China
10 shared publications Baojian Ji
Department of Automation, Nanjing University of Science and Technology, Nanjing, China
4 shared publications- Yufei Zhou
College of Electronic and Information Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications Yu Wu
College of Electronic and Information Engineering Nanjing University of Aeronautics and Astronautics Nanjing People's Republic of China
3 shared publicationsLongchun Li
College of Electrical Engineering and Control Science Nanjing Tech University Nanjing People's Republic of China
2 shared publications- Shuai Liu
Department of Electronic Information Engineering, Nanjing University of Aeronautics and Astronautics, NanJing, China
2 shared publications
Latest Publications
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13088-13102
A Full-Load Range Soft-Switching Method for Full Bridge Converter Based on Small Magnetizing Inductance and Segmented Fixed-Frequency Control
The rapid advancement of unmanned aerial vehicles (UAVs), military applications, and industrial technologies has placed higher demands on power sources: further enhancement of power density, coupled with the realization of high-efficiency conversion over the entire load range. In this paper, a soft-switching method is proposed for a full-bridge converter based on a small magnetizing inductance. The method does not require any auxiliary circuits. The reduction in magnetizing inductance can decrease the size of magnetic components, which is conducive to the enhancement of power density. The reduction in transformer magnetizing inductance poses new challenges for achieving soft-switching over the entire load range. This paper further proposes a segmented fixed-frequency PWM strategy, along with a corresponding dynamic dead-time adjustment method, to achieve soft-switching across the entire load range. The proposed method remains PWM-based, retaining its simplicity and fast dynamic response, without increasing the size of magnetic components. The paper analyzes the operating modes of the proposed converter under phase-shift control. It derives the coupling relationships among soft-switching conditions, leakage and magnetizing inductance, switching frequency, and dead time. Parameter design guidelines are provided, and the impact of the segmented fixed-frequency PWM strategy on power density is also discussed. A prototype with a power rating of 1kW and a rated switching frequency of 500kHz has been developed. Experimental validation has confirmed the effectiveness of the theoretical analysis. The prototype achieves a power density of 8.3kW/L, a peak efficiency of 95.5%, and an efficiency of 91.1% at light loads.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 13088-13102
A Full-Load Range Soft-Switching Method for Full Bridge Converter Based on Small Magnetizing Inductance and Segmented Fixed-Frequency Control
The rapid advancement of unmanned aerial vehicles (UAVs), military applications, and industrial technologies has placed higher demands on power sources: further enhancement of power density, coupled with the realization of high-efficiency conversion over the entire load range. In this paper, a soft-switching method is proposed for a full-bridge converter based on a small magnetizing inductance. The method does not require any auxiliary circuits. The reduction in magnetizing inductance can decrease the size of magnetic components, which is conducive to the enhancement of power density. The reduction in transformer magnetizing inductance poses new challenges for achieving soft-switching over the entire load range. This paper further proposes a segmented fixed-frequency PWM strategy, along with a corresponding dynamic dead-time adjustment method, to achieve soft-switching across the entire load range. The proposed method remains PWM-based, retaining its simplicity and fast dynamic response, without increasing the size of magnetic components. The paper analyzes the operating modes of the proposed converter under phase-shift control. It derives the coupling relationships among soft-switching conditions, leakage and magnetizing inductance, switching frequency, and dead time. Parameter design guidelines are provided, and the impact of the segmented fixed-frequency PWM strategy on power density is also discussed. A prototype with a power rating of 1kW and a rated switching frequency of 500kHz has been developed. Experimental validation has confirmed the effectiveness of the theoretical analysis. The prototype achieves a power density of 8.3kW/L, a peak efficiency of 95.5%, and an efficiency of 91.1% at light loads.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8285-8299
A High-Efficiency TPCM/DCM Mixed Conduction Mode for Five-Level Inverter
Discontinuous conduction mode (DCM) leverages its ZCS characteristics to significantly improve inverter efficiency. However, its inherent drawback of higher peak-to-average ratio (PAR) in inverter-side inductor current leads to increased current stress and device losses, thereby limiting practical applications. To address this issue, this article takes the T-type hybrid bridge five-level topology as an example and proposes a fixed-frequency mixed conduction mode modulation strategy for five-level inverters. By introducing a half-level implementation to achieve trapezoidal conduction mode, the inductor current is divided into three stages within one switching period, effectively reducing PAR and minimizing losses. When the instantaneous power is insufficient to maintain trapezoidal conduction mode, the inverter operates in five-level DCM, where the introduced half-level not only reduces PAR, but also improves duty cycle utilization in DCM. This article systematically analyzes the operational characteristics of the inverter under the proposed hybrid conduction mode modulation strategy. Mathematical derivations are provided for switch duty cycle calculations in each operating mode, along with a unified decision logic for mode selection based on real-time circuit conditions, enabling seamless mode transitions. Furthermore, an inductance selection methodology is developed to minimize both losses and current stress in the inverter-side inductor. A 500 W experimental prototype was constructed to validate the theoretical analysis, and the efficiency was significantly improve.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8285-8299
A High-Efficiency TPCM/DCM Mixed Conduction Mode for Five-Level Inverter
Discontinuous conduction mode (DCM) leverages its ZCS characteristics to significantly improve inverter efficiency. However, its inherent drawback of higher peak-to-average ratio (PAR) in inverter-side inductor current leads to increased current stress and device losses, thereby limiting practical applications. To address this issue, this article takes the T-type hybrid bridge five-level topology as an example and proposes a fixed-frequency mixed conduction mode modulation strategy for five-level inverters. By introducing a half-level implementation to achieve trapezoidal conduction mode, the inductor current is divided into three stages within one switching period, effectively reducing PAR and minimizing losses. When the instantaneous power is insufficient to maintain trapezoidal conduction mode, the inverter operates in five-level DCM, where the introduced half-level not only reduces PAR, but also improves duty cycle utilization in DCM. This article systematically analyzes the operational characteristics of the inverter under the proposed hybrid conduction mode modulation strategy. Mathematical derivations are provided for switch duty cycle calculations in each operating mode, along with a unified decision logic for mode selection based on real-time circuit conditions, enabling seamless mode transitions. Furthermore, an inductance selection methodology is developed to minimize both losses and current stress in the inverter-side inductor. A 500 W experimental prototype was constructed to validate the theoretical analysis, and the efficiency was significantly improve.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12706-12718
A Full Duty Cycle Range Soft-Switching High Frequency and High-Efficiency Dual-Buck-ZVT Inverter
The dual buck inverter excels as a highly reliable solution for demanding applications such as aeronautical static converters and traction converters. This is due to its features of no risk of high-frequency bridge-leg shoot-through and independent freewheeling diodes. As these applications evolve toward higher frequencies and greater efficiency, existing dual buck inverters face limitations. Restricted by limited progress in soft-switching (SS) techniques, they currently suffer from low-switching frequencies and the need for bulky magnetic components. These limitations do not align with the evolving demands of these applications. This article proposes a novel single inductor dual-buck-zero-voltage transition (ZVT) SS inverter structure, and based on the SPWM high-frequency modulation with this new ZVT structure, a new dynamic lead time control method is proposed, which helps the ZVT circuit to utilize the auxiliary inductor to transfer the energy to the load and reduces the conduction loss of the ZVT circuit, thus ensuring high efficiency of the inverter during high-frequency operation. This article comprehensively analyzes the control strategy, circuit performance, and parametric design of the proposed dual-buck-ZVT SS inverter, including a detailed investigation of SS region and current stress. To validate the effectiveness of this inverter, an experimental prototype operating at 400 kHz and 1000 W was built. This prototype achieved full duty cycle range SS with a peak efficiency of 97.5%.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12706-12718
A Full Duty Cycle Range Soft-Switching High Frequency and High-Efficiency Dual-Buck-ZVT Inverter
The dual buck inverter excels as a highly reliable solution for demanding applications such as aeronautical static converters and traction converters. This is due to its features of no risk of high-frequency bridge-leg shoot-through and independent freewheeling diodes. As these applications evolve toward higher frequencies and greater efficiency, existing dual buck inverters face limitations. Restricted by limited progress in soft-switching (SS) techniques, they currently suffer from low-switching frequencies and the need for bulky magnetic components. These limitations do not align with the evolving demands of these applications. This article proposes a novel single inductor dual-buck-zero-voltage transition (ZVT) SS inverter structure, and based on the SPWM high-frequency modulation with this new ZVT structure, a new dynamic lead time control method is proposed, which helps the ZVT circuit to utilize the auxiliary inductor to transfer the energy to the load and reduces the conduction loss of the ZVT circuit, thus ensuring high efficiency of the inverter during high-frequency operation. This article comprehensively analyzes the control strategy, circuit performance, and parametric design of the proposed dual-buck-ZVT SS inverter, including a detailed investigation of SS region and current stress. To validate the effectiveness of this inverter, an experimental prototype operating at 400 kHz and 1000 W was built. This prototype achieved full duty cycle range SS with a peak efficiency of 97.5%.
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13113-13125
A Passive Lossless and Nonshoot-Through Soft-Switching High Power Density Inverter
Soft switching technique is the main method to increase the inverter switching frequency and thus improve the power density, which is one of the current research hotspots. Inverter soft switching needs to operate in four quadrants, wide range, time-varying load current conditions, the realization of the more complex. At this stage, soft-switching inverters are mainly based on bridge circuits, and the intertwined soft-switching and shoot-through deadtime problems in bridge circuits are one of the difficulties in limiting the improvement of inverter switching frequency and power density. To solve this problem, a passive lossless and nonshoot-through soft-switching inverter is designed in this article, which fundamentally eliminates the constraints of shoot-through to soft-switching of the inverter. The four-quadrant operating mode is given, in which the high-frequency chopper bridge operates at unidirectional voltage and current conditions, thus achieving full-load range soft switching using passive coupled inductors. Increased switching frequency and the size of the filtering components is significantly reduced. This article analyses the specific operating modes, soft switching conditions, losses, parameters, and control methods. A 1-kW prototype is established, and the results of the experiment verify the correctness of the theoretical analysis. The prototype achieves the power density of 5.8 kW/L and the peak efficiency of 97.1% at 400 kHz.
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13113-13125
A Passive Lossless and Nonshoot-Through Soft-Switching High Power Density Inverter
Soft switching technique is the main method to increase the inverter switching frequency and thus improve the power density, which is one of the current research hotspots. Inverter soft switching needs to operate in four quadrants, wide range, time-varying load current conditions, the realization of the more complex. At this stage, soft-switching inverters are mainly based on bridge circuits, and the intertwined soft-switching and shoot-through deadtime problems in bridge circuits are one of the difficulties in limiting the improvement of inverter switching frequency and power density. To solve this problem, a passive lossless and nonshoot-through soft-switching inverter is designed in this article, which fundamentally eliminates the constraints of shoot-through to soft-switching of the inverter. The four-quadrant operating mode is given, in which the high-frequency chopper bridge operates at unidirectional voltage and current conditions, thus achieving full-load range soft switching using passive coupled inductors. Increased switching frequency and the size of the filtering components is significantly reduced. This article analyses the specific operating modes, soft switching conditions, losses, parameters, and control methods. A 1-kW prototype is established, and the results of the experiment verify the correctness of the theoretical analysis. The prototype achieves the power density of 5.8 kW/L and the peak efficiency of 97.1% at 400 kHz.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (1) , 259-270
High-Frequency High-Power Density Multicell Transformer-Coupled Input-Series-Output-Parallel (ISOP) Double Clamp ZVS Flyback Converter
Double-clamp zero-voltage-switching (DCZVS) fullbridge flyback converter is one of the most attractive solutions for high power density applications with wide input range, because of its features of primary side regulation (PSR) and excellent softswitching. By analyzing the ZVS process and the maximum output power at maximum flux, this paper reveals that the dead-time is one of the key parameters to restrict the output power of the DCZVS converter at high switching frequency. Then, the multicell transformer-coupled input-series-output-parallel (ISOP) structure is proposed in this paper to shorten the dead-time so as to improve the output power of the DCZVS converter, which does not increase the size of the transformer. In the multi-cell converters, the number of cells and the transformer design are also discussed. Finally, A DCZVS prototype with two transformercoupled ISOP cells is built up to validate the design, which achieves a wide input range of 160V-420V and realizes a 28V/20A output with a power density of 1203 W/inch3 and a peak efficiency of 93.69%. Compared with the original DCZVS converter, the proposed two-cell DCZVS converter achieves a 15% increase in power density with the same transformer size and maximum flux.
- 22 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 6 (1) , 259-270
High-Frequency High-Power Density Multicell Transformer-Coupled Input-Series-Output-Parallel (ISOP) Double Clamp ZVS Flyback Converter
Double-clamp zero-voltage-switching (DCZVS) fullbridge flyback converter is one of the most attractive solutions for high power density applications with wide input range, because of its features of primary side regulation (PSR) and excellent softswitching. By analyzing the ZVS process and the maximum output power at maximum flux, this paper reveals that the dead-time is one of the key parameters to restrict the output power of the DCZVS converter at high switching frequency. Then, the multicell transformer-coupled input-series-output-parallel (ISOP) structure is proposed in this paper to shorten the dead-time so as to improve the output power of the DCZVS converter, which does not increase the size of the transformer. In the multi-cell converters, the number of cells and the transformer design are also discussed. Finally, A DCZVS prototype with two transformercoupled ISOP cells is built up to validate the design, which achieves a wide input range of 160V-420V and realizes a 28V/20A output with a power density of 1203 W/inch3 and a peak efficiency of 93.69%. Compared with the original DCZVS converter, the proposed two-cell DCZVS converter achieves a 15% increase in power density with the same transformer size and maximum flux.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2846-2854
External Embedded Multi-U-Shaped Column Rotary Transformer With High Efficiency and Stability
The contactless rotary transformer based on wireless power transmission technology can solve the problems of excessive friction loss and low system stability, which caused by the rotation of traditional conductive slip rings in the operation time. In this paper, an external embedded multi-U-shaped rotary transformer(EEMUCRT) based on discrete spliced core is proposed. This structure embeds the outer core into the inner core. Compared with the structures mentioned earlier in the article, the coupling coefficient of the system is higher on the premise of smaller volume and weight. Based on the analysis of the magnetic core arrangement and the magnetic circuit model, the optimal structural parameters and arrangement of the primary and secondary magnetic cores are obtained by theoretical calculation and simulation. In order to verify the rotational stability and offset tolerance of the structure, an experimental prototype was built, and the results showed that the EEMUCRT can transmit energy efficiently and has good stabilit
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2846-2854
External Embedded Multi-U-Shaped Column Rotary Transformer With High Efficiency and Stability
The contactless rotary transformer based on wireless power transmission technology can solve the problems of excessive friction loss and low system stability, which caused by the rotation of traditional conductive slip rings in the operation time. In this paper, an external embedded multi-U-shaped rotary transformer(EEMUCRT) based on discrete spliced core is proposed. This structure embeds the outer core into the inner core. Compared with the structures mentioned earlier in the article, the coupling coefficient of the system is higher on the premise of smaller volume and weight. Based on the analysis of the magnetic core arrangement and the magnetic circuit model, the optimal structural parameters and arrangement of the primary and secondary magnetic cores are obtained by theoretical calculation and simulation. In order to verify the rotational stability and offset tolerance of the structure, an experimental prototype was built, and the results showed that the EEMUCRT can transmit energy efficiently and has good stabilit
- 11 April 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (4) , 2367-2377
The Misaligned Coupling Improvement of Loosely Coupled Transformer with Multi-Receivers for IPT System
- 11 April 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (4) , 2367-2377
The Misaligned Coupling Improvement of Loosely Coupled Transformer with Multi-Receivers for IPT System
- 4 June 2021
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (5) , 2573-2584
Design Methodology of LLC Resonant Converters for Single-stage Power Factor Correction Application
- 4 June 2021
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 16 (5) , 2573-2584
Design Methodology of LLC Resonant Converters for Single-stage Power Factor Correction Application
- Open Access
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 79643-79650
An Isolated Single-Stage Four-Quadrant Inverter With Energy Storage Capacitor
In this paper, a single-stage full-bridge inverter with energy storage capacitor is proposed. The high-frequency transformer is used to achieve boosting voltage and electrical isolation. The energy storage capacitor is introduced in the secondary side and the stored energy is fed back into the bus capacitor through the body diode when energy is fed back reversely. Accordingly when energy flows forward, the energy stored in the bus capacitor is released to reach the energy balance of bus capacitor in each power frequency cycle, and thereby achieve the four-quadrant operation of inverter. Thus, problems of energy being fed back into the DC bus directly and increasing complexity of circuit are avoided. When the inverter is connected to the grid, the bus capacitor can be disconnected from the circuit and a single-phase single-stage grid-connected inverter is achieved. The operating principle and control strategy of the topology are analyzed in detail and the feasibility is proved by experiments.
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 79643-79650
Open AccessAn Isolated Single-Stage Four-Quadrant Inverter With Energy Storage Capacitor
In this paper, a single-stage full-bridge inverter with energy storage capacitor is proposed. The high-frequency transformer is used to achieve boosting voltage and electrical isolation. The energy storage capacitor is introduced in the secondary side and the stored energy is fed back into the bus capacitor through the body diode when energy is fed back reversely. Accordingly when energy flows forward, the energy stored in the bus capacitor is released to reach the energy balance of bus capacitor in each power frequency cycle, and thereby achieve the four-quadrant operation of inverter. Thus, problems of energy being fed back into the DC bus directly and increasing complexity of circuit are avoided. When the inverter is connected to the grid, the bus capacitor can be disconnected from the circuit and a single-phase single-stage grid-connected inverter is achieved. The operating principle and control strategy of the topology are analyzed in detail and the feasibility is proved by experiments.
- 17 November 2020
- Published by Springer Nature in Journal of Power Electronics
- Vol. 21 (1) , 113-125
Soft-switching buck inverter
- 17 November 2020
- Published by Springer Nature in Journal of Power Electronics
- Vol. 21 (1) , 113-125
Soft-switching buck inverter