Abraham Schoe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abraham Schoe has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Evert de Jonge
All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
6 shared publications- Evert de Jonge
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
5 shared publications - Franciska van der Velde-Quist
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
5 shared publications - Jacob W. M. Bsc Snoep
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
5 shared publications - Florence Elise Smits
Department of Intensive Care, Leiden University Medical Center, Leiden, 2333 ZA, the Netherlands
4 shared publications Jaap T. van Dissel
Department of infectious diseases, Leiden University Medical Centre, University of Leiden, Leiden, the Netherlands
4 shared publications
Latest Publications
- Open Access
- 4 April 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 256, 108809
Prognostic value of the dead space fraction in invasive mechanical ventilation using the Enghoff equation - a single center retrospective cohort study
- 4 April 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 256, 108809
Open AccessPrognostic value of the dead space fraction in invasive mechanical ventilation using the Enghoff equation - a single center retrospective cohort study
- Open Access
- 12 August 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (11) , e2261-e2270
The Association Between Patient-Ventilator Asynchrony and Clinical Outcomes in Mechanically Ventilated Patients: A Systematic Review
OBJECTIVES: To evaluate associations between patient-ventilator asynchrony (PVA) and clinical outcome measures. DATA SOURCES: For this systematic review, the databases of PubMed, Web of Science, Embase, Cochrane Library, and Emcare were screened until June 20, 2024. STUDY SELECTION: The main inclusion criterion was the assessment of the association of PVA with clinical outcome measures (length of ICU stay, mechanical ventilation duration, and mortality). DATA EXTRACTION: All forms of PVA subtypes reported in the articles were systematically collected. Furthermore, the method used to identify asynchrony and the clinical outcomes described were recorded from each study. DATA SYNTHESIS: A total of 19 studies were included with a total of 2672 patients. The results of the meta-analysis show that overall PVA and ineffective triggering and double triggering are associated with a longer duration of mechanical ventilation (mean difference, 3.29 d; 95% CI, 0.13–6.44 d), and with a longer ICU length of stay (mean difference, 3.65 d; 95% CI, 1.20–6.11 d). No association was found between PVA and mortality. In addition, reverse triggering appears to have a potential positive association with outcome. CONCLUSIONS: PVA and specifically ineffective triggering and double triggering, are associated with a longer duration of mechanical ventilation and longer ICU length of stay.
- 12 August 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (11) , e2261-e2270
Open AccessThe Association Between Patient-Ventilator Asynchrony and Clinical Outcomes in Mechanically Ventilated Patients: A Systematic Review
OBJECTIVES: To evaluate associations between patient-ventilator asynchrony (PVA) and clinical outcome measures. DATA SOURCES: For this systematic review, the databases of PubMed, Web of Science, Embase, Cochrane Library, and Emcare were screened until June 20, 2024. STUDY SELECTION: The main inclusion criterion was the assessment of the association of PVA with clinical outcome measures (length of ICU stay, mechanical ventilation duration, and mortality). DATA EXTRACTION: All forms of PVA subtypes reported in the articles were systematically collected. Furthermore, the method used to identify asynchrony and the clinical outcomes described were recorded from each study. DATA SYNTHESIS: A total of 19 studies were included with a total of 2672 patients. The results of the meta-analysis show that overall PVA and ineffective triggering and double triggering are associated with a longer duration of mechanical ventilation (mean difference, 3.29 d; 95% CI, 0.13–6.44 d), and with a longer ICU length of stay (mean difference, 3.65 d; 95% CI, 1.20–6.11 d). No association was found between PVA and mortality. In addition, reverse triggering appears to have a potential positive association with outcome. CONCLUSIONS: PVA and specifically ineffective triggering and double triggering, are associated with a longer duration of mechanical ventilation and longer ICU length of stay.
- Open Access
- 11 June 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (8) , e1650-e1658
P0.1 is an Unreliable Measure of Effort in Support Mechanical Ventilation in Comparison With Esophageal-Derived Measures of Effort: A Comparison Study
OBJECTIVE: Respiratory effort should be assessed in patients on mechanical ventilation in support mode. With the insertion of esophageal balloons, it is possible to measure different parameters of effort, such as change in esophageal pressure (ΔPes), work of breathing (WOB), and pressure-time product (PTP). Although some studies advocate for the use of P0.1 as a measure of effort, there is significant controversy as it is considered more a measure of respiratory drive. This study investigates the correlation between P0.1 and esophageal-derived parameters of effort. DESIGN: This was a retrospective observational comparison study. SETTING: This study is conducted in the mixed medical-surgical ICU at the Leiden University Medical Center (Leiden, The Netherlands). PATIENTS: Data were collected from 30 mechanically ventilated patients in spontaneous breathing mode. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: From each patient, a minimum of three different time frames of 5 minutes were used to collect the average values of P0.1, WOB, PTP, and ΔPes over this time frame. Statistical models accounting for repeated measurements were applied to assess correlations among these parameters. In total, 117 timeframes were analyzed from 39 patient cases. The analysis revealed poor correlations between P0.1, as measured in this study, and WOB (R 2 = 0.111), PTP (R 2 = 0.113), and ΔPes (R 2 = 0.034), whereas the esophageal-derived parameters showed high correlations with each other (PTP vs. WOB, R 2 = 0.886; ΔPes vs. WOB, R 2 = 0.848; and ΔPes vs. PTP, R 2 = 0.876). CONCLUSIONS: The results demonstrated poor correlations between P0.1 and the other effort parameters, whereas strong correlations were observed among ΔPes, WOB, and PTP. These findings underscore the need for careful consideration of monitoring tools to ensure appropriate assessment and management, and the importance of using esophageal catheters for accurate monitoring of respiratory effort, particularly in spontaneously breathing patients.
- 11 June 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (8) , e1650-e1658
Open AccessP0.1 is an Unreliable Measure of Effort in Support Mechanical Ventilation in Comparison With Esophageal-Derived Measures of Effort: A Comparison Study
OBJECTIVE: Respiratory effort should be assessed in patients on mechanical ventilation in support mode. With the insertion of esophageal balloons, it is possible to measure different parameters of effort, such as change in esophageal pressure (ΔPes), work of breathing (WOB), and pressure-time product (PTP). Although some studies advocate for the use of P0.1 as a measure of effort, there is significant controversy as it is considered more a measure of respiratory drive. This study investigates the correlation between P0.1 and esophageal-derived parameters of effort. DESIGN: This was a retrospective observational comparison study. SETTING: This study is conducted in the mixed medical-surgical ICU at the Leiden University Medical Center (Leiden, The Netherlands). PATIENTS: Data were collected from 30 mechanically ventilated patients in spontaneous breathing mode. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: From each patient, a minimum of three different time frames of 5 minutes were used to collect the average values of P0.1, WOB, PTP, and ΔPes over this time frame. Statistical models accounting for repeated measurements were applied to assess correlations among these parameters. In total, 117 timeframes were analyzed from 39 patient cases. The analysis revealed poor correlations between P0.1, as measured in this study, and WOB (R 2 = 0.111), PTP (R 2 = 0.113), and ΔPes (R 2 = 0.034), whereas the esophageal-derived parameters showed high correlations with each other (PTP vs. WOB, R 2 = 0.886; ΔPes vs. WOB, R 2 = 0.848; and ΔPes vs. PTP, R 2 = 0.876). CONCLUSIONS: The results demonstrated poor correlations between P0.1 and the other effort parameters, whereas strong correlations were observed among ΔPes, WOB, and PTP. These findings underscore the need for careful consideration of monitoring tools to ensure appropriate assessment and management, and the importance of using esophageal catheters for accurate monitoring of respiratory effort, particularly in spontaneously breathing patients.
- Open Access
- 3 March 2025
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 7 (3) , e1224
Mechanical Power in Pressure-Controlled Ventilation: A Simple and Reliable Bedside Method
BACKGROUND: Mechanical power (MP) represents the amount of energy applied by the ventilator to the respiratory system over time. There are two main methods to calculate MP in mechanical ventilation. The first is the geometric method, which directly measures the dynamic inspiratory area of the pressure-volume loop during the respiratory cycle. The second involves using various algebraic equations to estimate MP. However, almost all calculations are either complex or not reliable compared with the geometric method, considered the gold standard. This study aimed to develop an easy to use, reliable equation for bedside calculation of MP and to compare its accuracy with other existing equations for calculating MP. METHODS: In a preliminary study, we measured MP in 56 cases who were mechanically ventilated and without spontaneous breathing efforts. The measurements were done at the ICU of a single university medical center in the Netherlands. RESULTS: We found that the MP can be accurately calculated using an equation that incorporates the plateau pressure in 56 cases in 42 patients. The MP estimated with our new proposed equation (MP calculated using plateau pressure) correlated well with the reference value of MP with a bias of 0.2 J/min. The 95% limits of agreement (LoAs) were –3.1 to + 3.4 J/min. Other equations give the following bias and LoAs; bias of –0.8, LoA –3.8 to 1.9 J/min (van der Meijden equation), bias of –1.9, LoA –3.7 to –0.0 J/min (comprehensive Becher equation), bias of –2.4, LoA –4.5 to –0.3 J/min (simplified Becher equation), and a bias of –1.9, LoA –3.7 to 0.1 J/min (linear model equation). CONCLUSIONS: The equation we propose to calculate MP in pressure-controlled ventilation is a reliable, simple, and accurate alternative for the previously published equations. Consequently, this method is highly suitable for routine use in clinical practice.
- 3 March 2025
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 7 (3) , e1224
Open AccessMechanical Power in Pressure-Controlled Ventilation: A Simple and Reliable Bedside Method
BACKGROUND: Mechanical power (MP) represents the amount of energy applied by the ventilator to the respiratory system over time. There are two main methods to calculate MP in mechanical ventilation. The first is the geometric method, which directly measures the dynamic inspiratory area of the pressure-volume loop during the respiratory cycle. The second involves using various algebraic equations to estimate MP. However, almost all calculations are either complex or not reliable compared with the geometric method, considered the gold standard. This study aimed to develop an easy to use, reliable equation for bedside calculation of MP and to compare its accuracy with other existing equations for calculating MP. METHODS: In a preliminary study, we measured MP in 56 cases who were mechanically ventilated and without spontaneous breathing efforts. The measurements were done at the ICU of a single university medical center in the Netherlands. RESULTS: We found that the MP can be accurately calculated using an equation that incorporates the plateau pressure in 56 cases in 42 patients. The MP estimated with our new proposed equation (MP calculated using plateau pressure) correlated well with the reference value of MP with a bias of 0.2 J/min. The 95% limits of agreement (LoAs) were –3.1 to + 3.4 J/min. Other equations give the following bias and LoAs; bias of –0.8, LoA –3.8 to 1.9 J/min (van der Meijden equation), bias of –1.9, LoA –3.7 to –0.0 J/min (comprehensive Becher equation), bias of –2.4, LoA –4.5 to –0.3 J/min (simplified Becher equation), and a bias of –1.9, LoA –3.7 to 0.1 J/min (linear model equation). CONCLUSIONS: The equation we propose to calculate MP in pressure-controlled ventilation is a reliable, simple, and accurate alternative for the previously published equations. Consequently, this method is highly suitable for routine use in clinical practice.
- Open Access
- 16 January 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 237, 107949
Oxygen consumption, effort, and weaning in the mechanically ventilated patient in the intensive care unit: The extubate study: A protocol for an observational study
- 16 January 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 237, 107949
Open AccessOxygen consumption, effort, and weaning in the mechanically ventilated patient in the intensive care unit: The extubate study: A protocol for an observational study
- Open Access
- 19 December 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (12) , e1190
Mechanical Power Is Associated With Mortality in Pressure-Controlled Ventilated Patients: A Dutch, Single-Center Cohort Study
IMPORTANCE: Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES: This study aims to investigate the association between MP and hospital mortality across varying degrees of lung disease severity, classified by Pao 2/Fio 2 ratios. DESIGN, SETTING, AND PARTICIPANTS: This is a retrospective cohort study using automatically extracted data. Patients admitted to the ICU of a tertiary referral hospital in The Netherlands between 2018 and 2024 and ventilated in pressure-controlled mode were included. MAIN OUTCOMES AND MEASURES: Logistic regression, adjusted for age, sex, Acute Physiology and Chronic Health Evaluation-IV score, and Pao 2/Fio 2 ratio, was used to calculate the odds ratio (OR) for all-cause in-hospital mortality. RESULTS: A total of 2184 patients were analyzed, with a mean age of 62.5 ± 13.8 years, of whom 1508 (70.2%) were male. The mean MP was highest in patients with the lowest Pao 2/Fio 2 ratios (21.5 ± 6.5 J/min) compared with those with the highest ratios (12.0 ± 3.8 J/min; p < 0.001). Adjusted analyses revealed that increased MP was associated with higher mortality (OR, 1.06; 95% CI, 1.03–1.09 per J/min increase). Similarly, MP normalized for body weight showed a stronger association with mortality (OR, 1.004; 95% CI, 1.002–1.006 per J/min/kg increase). An increase in mortality was seen when MP exceeded 16–18 J/min. CONCLUSIONS AND RELEVANCE: Our findings demonstrate a significant association between MP and hospital mortality, even after adjusting for key confounders. Mortality increases notably when MP exceeds 16–18 J/min. Normalized MP presents an even stronger association with mortality. These results underscore the need for further research into ventilation strategies that consider MP adjustments.
- 19 December 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (12) , e1190
Open AccessMechanical Power Is Associated With Mortality in Pressure-Controlled Ventilated Patients: A Dutch, Single-Center Cohort Study
IMPORTANCE: Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES: This study aims to investigate the association between MP and hospital mortality across varying degrees of lung disease severity, classified by Pao 2/Fio 2 ratios. DESIGN, SETTING, AND PARTICIPANTS: This is a retrospective cohort study using automatically extracted data. Patients admitted to the ICU of a tertiary referral hospital in The Netherlands between 2018 and 2024 and ventilated in pressure-controlled mode were included. MAIN OUTCOMES AND MEASURES: Logistic regression, adjusted for age, sex, Acute Physiology and Chronic Health Evaluation-IV score, and Pao 2/Fio 2 ratio, was used to calculate the odds ratio (OR) for all-cause in-hospital mortality. RESULTS: A total of 2184 patients were analyzed, with a mean age of 62.5 ± 13.8 years, of whom 1508 (70.2%) were male. The mean MP was highest in patients with the lowest Pao 2/Fio 2 ratios (21.5 ± 6.5 J/min) compared with those with the highest ratios (12.0 ± 3.8 J/min; p < 0.001). Adjusted analyses revealed that increased MP was associated with higher mortality (OR, 1.06; 95% CI, 1.03–1.09 per J/min increase). Similarly, MP normalized for body weight showed a stronger association with mortality (OR, 1.004; 95% CI, 1.002–1.006 per J/min/kg increase). An increase in mortality was seen when MP exceeded 16–18 J/min. CONCLUSIONS AND RELEVANCE: Our findings demonstrate a significant association between MP and hospital mortality, even after adjusting for key confounders. Mortality increases notably when MP exceeds 16–18 J/min. Normalized MP presents an even stronger association with mortality. These results underscore the need for further research into ventilation strategies that consider MP adjustments.
- Open Access
- 15 August 2022
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 4 (8) , e0741
Mechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes
OBJECTIVES: Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The pressure-volume (PV) loop, from which the MP is calculated, is different for VCV compared with PCV. We aimed to compare the MP of VCV with zero pause time (VCV-0), VCV with 10% pause time (VCV-10), and PCV within patients in different patient categories based on severity of lung injury. DESIGN: In a proof-of-concept study, we enrolled 46 mechanically ventilated patients without spontaneous breathing efforts. Baseline measurements were done in pressure-controlled mode. Subsequently, measurements were done in VCV-0 and VCV-10. Tidal volume and all other settings were kept the same. SETTING: ICU, single university medical center. PATIENTS: Fifty-eight cases in 46 patients on controlled ventilation modes. INTERVENTIONS: Comparison between the MP of PCV, VCV-0, and VCV-10. MEASUREMENT AND MAIN RESULTS: The mean MP of VCV-0, VCV-10, and PCV was 19.30, 21.80, and 20.87 J/min, respectively (p < 0.05 for all comparisons). The transpulmonary MP of VCV-0, VCV-10, and PCV was 6.75, 8.60, and 7.99 J/min, respectively (p < 0.05 for all comparisons). CONCLUSIONS: In patients ventilated in a controlled mode, VCV without pause time had the lowest MP followed by PCV. VCV with 10% pause time had the highest MP.
- 15 August 2022
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 4 (8) , e0741
Open AccessMechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes
OBJECTIVES: Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The pressure-volume (PV) loop, from which the MP is calculated, is different for VCV compared with PCV. We aimed to compare the MP of VCV with zero pause time (VCV-0), VCV with 10% pause time (VCV-10), and PCV within patients in different patient categories based on severity of lung injury. DESIGN: In a proof-of-concept study, we enrolled 46 mechanically ventilated patients without spontaneous breathing efforts. Baseline measurements were done in pressure-controlled mode. Subsequently, measurements were done in VCV-0 and VCV-10. Tidal volume and all other settings were kept the same. SETTING: ICU, single university medical center. PATIENTS: Fifty-eight cases in 46 patients on controlled ventilation modes. INTERVENTIONS: Comparison between the MP of PCV, VCV-0, and VCV-10. MEASUREMENT AND MAIN RESULTS: The mean MP of VCV-0, VCV-10, and PCV was 19.30, 21.80, and 20.87 J/min, respectively (p < 0.05 for all comparisons). The transpulmonary MP of VCV-0, VCV-10, and PCV was 6.75, 8.60, and 7.99 J/min, respectively (p < 0.05 for all comparisons). CONCLUSIONS: In patients ventilated in a controlled mode, VCV without pause time had the lowest MP followed by PCV. VCV with 10% pause time had the highest MP.
- Open Access
- 13 March 2020
- Published by Springer Nature in BMC Anesthesiology
- Vol. 20 (1) , 1-8
Mortality prediction by SOFA score in ICU-patients after cardiac surgery; comparison with traditional prognostic–models
Background: There are many prognostic models and scoring systems in use to predict mortality in ICU patients. The only general ICU scoring system developed and validated for patients after cardiac surgery is the APACHE-IV model. This is, however, a labor-intensive scoring system requiring a lot of data and could therefore be prone to error. The SOFA score on the other hand is a simpler system, has been widely used in ICUs and could be a good alternative. The goal of the study was to compare the SOFA score with the APACHE-IV and other ICU prediction models. Methods: We investigated, in a large cohort of cardiac surgery patients admitted to Dutch ICUs, how well the SOFA score from the first 24 h after admission, predict hospital and ICU mortality in comparison with other recalibrated general ICU scoring systems. Measures of discrimination, accuracy, and calibration (area under the receiver operating characteristic curve (AUC), Brier score, R2, and Ĉ-statistic) were calculated using bootstrapping. The cohort consisted of 36,632 Patients from the Dutch National Intensive Care Evaluation (NICE) registry having had a cardiac surgery procedure for which ICU admission was necessary between January 1st, 2006 and June 31st, 2018. Results: Discrimination of the SOFA-, APACHE-IV-, APACHE-II-, SAPS-II-, MPM24-II - models to predict hospital mortality was good with an AUC of respectively: 0.809, 0.851, 0.830, 0.850, 0.801. Discrimination of the SOFA-, APACHE-IV-, APACHE-II-, SAPS-II-, MPM24-II - models to predict ICU mortality was slightly better with AUCs of respectively: 0.809, 0.906, 0.892, 0.919, 0.862. Calibration of the models was generally poor. Conclusion: Although the SOFA score had a good discriminatory power for hospital- and ICU mortality the discriminatory power of the APACHE-IV and SAPS-II was better. The SOFA score should not be preferred as mortality prediction model above traditional prognostic ICU-models.
- 13 March 2020
- Published by Springer Nature in BMC Anesthesiology
- Vol. 20 (1) , 1-8
Open AccessMortality prediction by SOFA score in ICU-patients after cardiac surgery; comparison with traditional prognostic–models
Background: There are many prognostic models and scoring systems in use to predict mortality in ICU patients. The only general ICU scoring system developed and validated for patients after cardiac surgery is the APACHE-IV model. This is, however, a labor-intensive scoring system requiring a lot of data and could therefore be prone to error. The SOFA score on the other hand is a simpler system, has been widely used in ICUs and could be a good alternative. The goal of the study was to compare the SOFA score with the APACHE-IV and other ICU prediction models. Methods: We investigated, in a large cohort of cardiac surgery patients admitted to Dutch ICUs, how well the SOFA score from the first 24 h after admission, predict hospital and ICU mortality in comparison with other recalibrated general ICU scoring systems. Measures of discrimination, accuracy, and calibration (area under the receiver operating characteristic curve (AUC), Brier score, R2, and Ĉ-statistic) were calculated using bootstrapping. The cohort consisted of 36,632 Patients from the Dutch National Intensive Care Evaluation (NICE) registry having had a cardiac surgery procedure for which ICU admission was necessary between January 1st, 2006 and June 31st, 2018. Results: Discrimination of the SOFA-, APACHE-IV-, APACHE-II-, SAPS-II-, MPM24-II - models to predict hospital mortality was good with an AUC of respectively: 0.809, 0.851, 0.830, 0.850, 0.801. Discrimination of the SOFA-, APACHE-IV-, APACHE-II-, SAPS-II-, MPM24-II - models to predict ICU mortality was slightly better with AUCs of respectively: 0.809, 0.906, 0.892, 0.919, 0.862. Calibration of the models was generally poor. Conclusion: Although the SOFA score had a good discriminatory power for hospital- and ICU mortality the discriminatory power of the APACHE-IV and SAPS-II was better. The SOFA score should not be preferred as mortality prediction model above traditional prognostic ICU-models.
- 22 October 2019
- Published by Springer Nature in Intensive Care Medicine
- Vol. 46 (3) , 568-569
Calculation of the mechanical power for pressure-controlled ventilation: a response
- 22 October 2019
- Published by Springer Nature in Intensive Care Medicine
- Vol. 46 (3) , 568-569
Calculation of the mechanical power for pressure-controlled ventilation: a response
- Open Access
- 1 August 2019
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 16, e00126
Interchangeability of sodium and chloride measurements by indirect and direct ISE assays: Stakeholders, take responsibility!
- 1 August 2019
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 16, e00126
Open AccessInterchangeability of sodium and chloride measurements by indirect and direct ISE assays: Stakeholders, take responsibility!