Florence Elise Smits
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Florence Elise Smits has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abraham Schoe
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
4 shared publications - Evert de Jonge
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
3 shared publications - Franciska van der Velde-Quist
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
3 shared publications - Jacob W. M. Bsc Snoep
Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
3 shared publications - Petra J. Bsc Rietveld
All authors: Department of Intensive Care, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications Abraham Schoe
Both authors: Department of Intensive Care, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 4 April 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 256, 108809
Prognostic value of the dead space fraction in invasive mechanical ventilation using the Enghoff equation - a single center retrospective cohort study
- 4 April 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 256, 108809
Open AccessPrognostic value of the dead space fraction in invasive mechanical ventilation using the Enghoff equation - a single center retrospective cohort study
- 2 December 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (12) , e2794-e2795
The authors reply:
- 2 December 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (12) , e2794-e2795
The authors reply:
- Open Access
- 11 June 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (8) , e1650-e1658
P0.1 is an Unreliable Measure of Effort in Support Mechanical Ventilation in Comparison With Esophageal-Derived Measures of Effort: A Comparison Study
OBJECTIVE: Respiratory effort should be assessed in patients on mechanical ventilation in support mode. With the insertion of esophageal balloons, it is possible to measure different parameters of effort, such as change in esophageal pressure (ΔPes), work of breathing (WOB), and pressure-time product (PTP). Although some studies advocate for the use of P0.1 as a measure of effort, there is significant controversy as it is considered more a measure of respiratory drive. This study investigates the correlation between P0.1 and esophageal-derived parameters of effort. DESIGN: This was a retrospective observational comparison study. SETTING: This study is conducted in the mixed medical-surgical ICU at the Leiden University Medical Center (Leiden, The Netherlands). PATIENTS: Data were collected from 30 mechanically ventilated patients in spontaneous breathing mode. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: From each patient, a minimum of three different time frames of 5 minutes were used to collect the average values of P0.1, WOB, PTP, and ΔPes over this time frame. Statistical models accounting for repeated measurements were applied to assess correlations among these parameters. In total, 117 timeframes were analyzed from 39 patient cases. The analysis revealed poor correlations between P0.1, as measured in this study, and WOB (R 2 = 0.111), PTP (R 2 = 0.113), and ΔPes (R 2 = 0.034), whereas the esophageal-derived parameters showed high correlations with each other (PTP vs. WOB, R 2 = 0.886; ΔPes vs. WOB, R 2 = 0.848; and ΔPes vs. PTP, R 2 = 0.876). CONCLUSIONS: The results demonstrated poor correlations between P0.1 and the other effort parameters, whereas strong correlations were observed among ΔPes, WOB, and PTP. These findings underscore the need for careful consideration of monitoring tools to ensure appropriate assessment and management, and the importance of using esophageal catheters for accurate monitoring of respiratory effort, particularly in spontaneously breathing patients.
- 11 June 2025
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 53 (8) , e1650-e1658
Open AccessP0.1 is an Unreliable Measure of Effort in Support Mechanical Ventilation in Comparison With Esophageal-Derived Measures of Effort: A Comparison Study
OBJECTIVE: Respiratory effort should be assessed in patients on mechanical ventilation in support mode. With the insertion of esophageal balloons, it is possible to measure different parameters of effort, such as change in esophageal pressure (ΔPes), work of breathing (WOB), and pressure-time product (PTP). Although some studies advocate for the use of P0.1 as a measure of effort, there is significant controversy as it is considered more a measure of respiratory drive. This study investigates the correlation between P0.1 and esophageal-derived parameters of effort. DESIGN: This was a retrospective observational comparison study. SETTING: This study is conducted in the mixed medical-surgical ICU at the Leiden University Medical Center (Leiden, The Netherlands). PATIENTS: Data were collected from 30 mechanically ventilated patients in spontaneous breathing mode. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: From each patient, a minimum of three different time frames of 5 minutes were used to collect the average values of P0.1, WOB, PTP, and ΔPes over this time frame. Statistical models accounting for repeated measurements were applied to assess correlations among these parameters. In total, 117 timeframes were analyzed from 39 patient cases. The analysis revealed poor correlations between P0.1, as measured in this study, and WOB (R 2 = 0.111), PTP (R 2 = 0.113), and ΔPes (R 2 = 0.034), whereas the esophageal-derived parameters showed high correlations with each other (PTP vs. WOB, R 2 = 0.886; ΔPes vs. WOB, R 2 = 0.848; and ΔPes vs. PTP, R 2 = 0.876). CONCLUSIONS: The results demonstrated poor correlations between P0.1 and the other effort parameters, whereas strong correlations were observed among ΔPes, WOB, and PTP. These findings underscore the need for careful consideration of monitoring tools to ensure appropriate assessment and management, and the importance of using esophageal catheters for accurate monitoring of respiratory effort, particularly in spontaneously breathing patients.
- Open Access
- 16 January 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 237, 107949
Oxygen consumption, effort, and weaning in the mechanically ventilated patient in the intensive care unit: The extubate study: A protocol for an observational study
- 16 January 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 237, 107949
Open AccessOxygen consumption, effort, and weaning in the mechanically ventilated patient in the intensive care unit: The extubate study: A protocol for an observational study
- Open Access
- 19 December 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (12) , e1190
Mechanical Power Is Associated With Mortality in Pressure-Controlled Ventilated Patients: A Dutch, Single-Center Cohort Study
IMPORTANCE: Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES: This study aims to investigate the association between MP and hospital mortality across varying degrees of lung disease severity, classified by Pao 2/Fio 2 ratios. DESIGN, SETTING, AND PARTICIPANTS: This is a retrospective cohort study using automatically extracted data. Patients admitted to the ICU of a tertiary referral hospital in The Netherlands between 2018 and 2024 and ventilated in pressure-controlled mode were included. MAIN OUTCOMES AND MEASURES: Logistic regression, adjusted for age, sex, Acute Physiology and Chronic Health Evaluation-IV score, and Pao 2/Fio 2 ratio, was used to calculate the odds ratio (OR) for all-cause in-hospital mortality. RESULTS: A total of 2184 patients were analyzed, with a mean age of 62.5 ± 13.8 years, of whom 1508 (70.2%) were male. The mean MP was highest in patients with the lowest Pao 2/Fio 2 ratios (21.5 ± 6.5 J/min) compared with those with the highest ratios (12.0 ± 3.8 J/min; p < 0.001). Adjusted analyses revealed that increased MP was associated with higher mortality (OR, 1.06; 95% CI, 1.03–1.09 per J/min increase). Similarly, MP normalized for body weight showed a stronger association with mortality (OR, 1.004; 95% CI, 1.002–1.006 per J/min/kg increase). An increase in mortality was seen when MP exceeded 16–18 J/min. CONCLUSIONS AND RELEVANCE: Our findings demonstrate a significant association between MP and hospital mortality, even after adjusting for key confounders. Mortality increases notably when MP exceeds 16–18 J/min. Normalized MP presents an even stronger association with mortality. These results underscore the need for further research into ventilation strategies that consider MP adjustments.
- 19 December 2024
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 6 (12) , e1190
Open AccessMechanical Power Is Associated With Mortality in Pressure-Controlled Ventilated Patients: A Dutch, Single-Center Cohort Study
IMPORTANCE: Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES: This study aims to investigate the association between MP and hospital mortality across varying degrees of lung disease severity, classified by Pao 2/Fio 2 ratios. DESIGN, SETTING, AND PARTICIPANTS: This is a retrospective cohort study using automatically extracted data. Patients admitted to the ICU of a tertiary referral hospital in The Netherlands between 2018 and 2024 and ventilated in pressure-controlled mode were included. MAIN OUTCOMES AND MEASURES: Logistic regression, adjusted for age, sex, Acute Physiology and Chronic Health Evaluation-IV score, and Pao 2/Fio 2 ratio, was used to calculate the odds ratio (OR) for all-cause in-hospital mortality. RESULTS: A total of 2184 patients were analyzed, with a mean age of 62.5 ± 13.8 years, of whom 1508 (70.2%) were male. The mean MP was highest in patients with the lowest Pao 2/Fio 2 ratios (21.5 ± 6.5 J/min) compared with those with the highest ratios (12.0 ± 3.8 J/min; p < 0.001). Adjusted analyses revealed that increased MP was associated with higher mortality (OR, 1.06; 95% CI, 1.03–1.09 per J/min increase). Similarly, MP normalized for body weight showed a stronger association with mortality (OR, 1.004; 95% CI, 1.002–1.006 per J/min/kg increase). An increase in mortality was seen when MP exceeded 16–18 J/min. CONCLUSIONS AND RELEVANCE: Our findings demonstrate a significant association between MP and hospital mortality, even after adjusting for key confounders. Mortality increases notably when MP exceeds 16–18 J/min. Normalized MP presents an even stronger association with mortality. These results underscore the need for further research into ventilation strategies that consider MP adjustments.