Kazuyuki Minami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kazuyuki Minami has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Masanao Kobayashi
Graduate School of Medical Sciences, Fujita Health University, Toyoake, Japan
5 shared publications - Yasuki Asada
School of Medical Sciences Fujita Health University Toyoake Aichi Japan
5 shared publications - Yuta Matsunaga
School of Medical Sciences Fujita Health University Toyoake Aichi Japan
4 shared publications - Kenichi Kobayashi
Department of Radiology, Fujita Health University Hospital , Toyoake , Japan
3 shared publications - Koichi Chida
Department of Radiological Technology, Tohoku University Graduate School of Medicine, Sendai, Japan
3 shared publications - Shoichi Suzuki
School of Health Sciences, Fujita Health University, 1-98, Dengakugakubo, Kutsukake-cho, Toyoake, Aichi 470-1192, Japan
3 shared publications
Latest Publications
- 27 April 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (6) , 339-348
SIZE-SPECIFIC DOSE ESTIMATES IN FETAL COMPUTED TOMOGRAPHY
During fetal computed tomography (CT) imaging, because of differences in the pregnancy period and scanning conditions, different doses of radiation are absorbed by the fetus. We propose a correction coefficient for determining the fetal size-specific dose estimate (SSDE) from the CT dose index (CTDI) displayed on the console at tube voltages of 80–135 kVp. The CTDIs corresponding to pregnant women and fetuses were evaluated using a Monte Carlo (MC) simulation, and the ratio of these CTDIs was defined as the Fetus-factor. When the effective diameter of a fetus was approximately 10 cm, the Fetus-factor was 1.0. The estimated pregnant SSDE was multiplied by the Fetus-factor to estimate the fetal SSDE, which was compared with the fetal dose obtained by the MC simulation of the image of the fetal CT examination. The fetal dose could be estimated with an error of 31.5% in fetal examinations conducted using helical CT.
- 27 April 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (6) , 339-348
SIZE-SPECIFIC DOSE ESTIMATES IN FETAL COMPUTED TOMOGRAPHY
During fetal computed tomography (CT) imaging, because of differences in the pregnancy period and scanning conditions, different doses of radiation are absorbed by the fetus. We propose a correction coefficient for determining the fetal size-specific dose estimate (SSDE) from the CT dose index (CTDI) displayed on the console at tube voltages of 80–135 kVp. The CTDIs corresponding to pregnant women and fetuses were evaluated using a Monte Carlo (MC) simulation, and the ratio of these CTDIs was defined as the Fetus-factor. When the effective diameter of a fetus was approximately 10 cm, the Fetus-factor was 1.0. The estimated pregnant SSDE was multiplied by the Fetus-factor to estimate the fetal SSDE, which was compared with the fetal dose obtained by the MC simulation of the image of the fetal CT examination. The fetal dose could be estimated with an error of 31.5% in fetal examinations conducted using helical CT.
- Open Access
- 14 September 2020
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (4) , 1195-1206
Evaluation of exposure dose in fetal computed tomography using organ-effective modulation
Organ-effective modulation (OEM) is a computed tomography scanning technique that reduces the exposure dose to organs at risk. Ultrasonography is commonly used for prenatal imaging, but its reliability is reported to be limited. Radiography and computed tomography (CT) are reliable but pose risk of radiation exposure to the pregnant woman and her fetus. Although there are many reports on the exposure dose associated with fetal CT scans, no reports exist on OEM use in fetal CT scans. We measured the basic characteristics of organ-effective modulation (X-ray output modulation angle, maximum X-ray output modulation rate, total X-ray output modulation rate, and noise modulation) and used them in a Monte Carlo simulation to evaluate the effect of this technique on fetal CT scans in terms of image quality and exposure dose to the pregnant woman and fetus. Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation occurred at tube currents of 80 mA or below. Our findings suggest that OEM has only a minimal effect in reducing organ exposure in pregnant women; therefore, it should be used on the anterior side (OEMON,front) to reduce the exposure dose to the fetus.
- 14 September 2020
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (4) , 1195-1206
Open AccessEvaluation of exposure dose in fetal computed tomography using organ-effective modulation
Organ-effective modulation (OEM) is a computed tomography scanning technique that reduces the exposure dose to organs at risk. Ultrasonography is commonly used for prenatal imaging, but its reliability is reported to be limited. Radiography and computed tomography (CT) are reliable but pose risk of radiation exposure to the pregnant woman and her fetus. Although there are many reports on the exposure dose associated with fetal CT scans, no reports exist on OEM use in fetal CT scans. We measured the basic characteristics of organ-effective modulation (X-ray output modulation angle, maximum X-ray output modulation rate, total X-ray output modulation rate, and noise modulation) and used them in a Monte Carlo simulation to evaluate the effect of this technique on fetal CT scans in terms of image quality and exposure dose to the pregnant woman and fetus. Using ImPACT MC software, Monte Carlo simulations of OEMON and OEMOFF were run on 8 cases involving fetal CT scans. We confirmed that the organ-effective modulation X-ray output modulation angle was 160°; the X-ray output modulation rate increased with increasing tube current; and no modulation occurred at tube currents of 80 mA or below. Our findings suggest that OEM has only a minimal effect in reducing organ exposure in pregnant women; therefore, it should be used on the anterior side (OEMON,front) to reduce the exposure dose to the fetus.
- 30 July 2019
- Published by Wiley in X-Ray Spectrometry
- Vol. 48 (6) , 691-695
Development of a small X‐ray source using an ultraviolet laser and pyroelectric crystal
We investigate a miniaturized X‐ray source using an ultraviolet (UV) laser and a pyroelectric crystal and discuss potential applications in medicine. The UV laser is the fourth harmonic of a Nd:YAG laser with a wavelength of 266 nm, repetition rate of 10 Hz, and pulse energy of 40 mJ. The pyroelectric crystal is a LiNbO 3 cylinder of diameter 10 mm and length 6 mm. The prototype X‐ray source we fabricated is an aluminum parallelepiped of dimensions 3 × 3 × 5 cm. The X‐ray count rate of the X‐ray source is maximized at approximately 1,400 cps for UV laser irradiation of approximately 5 min. After 30 min of irradiation by the UV laser, the temperature of the pyroelectric crystal rose from 295 K to 312 K. The principles of X‐ray generation ensure that X‐ray sources using UV lasers and pyroelectric crystals offer ample opportunity for miniaturization. We believe the X‐ray source developed in this work is suitable for medical applications, although further study is needed to address points such as increasing the X‐ray count rate and adjusting the temperature of the pyroelectric crystal.
- 30 July 2019
- Published by Wiley in X-Ray Spectrometry
- Vol. 48 (6) , 691-695
Development of a small X‐ray source using an ultraviolet laser and pyroelectric crystal
We investigate a miniaturized X‐ray source using an ultraviolet (UV) laser and a pyroelectric crystal and discuss potential applications in medicine. The UV laser is the fourth harmonic of a Nd:YAG laser with a wavelength of 266 nm, repetition rate of 10 Hz, and pulse energy of 40 mJ. The pyroelectric crystal is a LiNbO 3 cylinder of diameter 10 mm and length 6 mm. The prototype X‐ray source we fabricated is an aluminum parallelepiped of dimensions 3 × 3 × 5 cm. The X‐ray count rate of the X‐ray source is maximized at approximately 1,400 cps for UV laser irradiation of approximately 5 min. After 30 min of irradiation by the UV laser, the temperature of the pyroelectric crystal rose from 295 K to 312 K. The principles of X‐ray generation ensure that X‐ray sources using UV lasers and pyroelectric crystals offer ample opportunity for miniaturization. We believe the X‐ray source developed in this work is suitable for medical applications, although further study is needed to address points such as increasing the X‐ray count rate and adjusting the temperature of the pyroelectric crystal.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180290
Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey
Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180290
Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey
Objective: To propose a new set of Japanese diagnostic reference levels (DRLs) and achievable doses (ADs) for 2017 and to verify the usefulness of Japanese DRLs (DRLs 2015) for CT, by investigating changes in the volume CT dose index (CTDIvol) from 2014 to 2017. Methods: Detailed information on the CT scan parameters used throughout Japan were obtained by questionnaire survey. The CTDIvol and dose-length product for the 11 commonest adult and 6 commonest paediatric CT examinations were surveyed and compared with 2014 data and DRLs 2015. Results: Evaluations of adult head (helical), and abdomen and pelvis without contrast agent, paediatric chest without contrast agent, and abdomen and pelvis without contrast agent showed a slightly lower mean CTDIvol in 2017 than in 2014 (t-test, p < 0.05). The interquartile range of CTDIvol for all 2017 examinations was lower than in 2014. Conclusions: This study verified the lower mean, 75th percentile, and interquartile range by investigating changes in the CTDIvol from 2014 to 2017. The DRLs 2015 contributed to CT radiation dose reduction. Advances in knowledge: The widespread implementation of iterative reconstruction algorithms and low-tube voltage in CT scanners is likely to facilitate further reduction in the CT radiation dose used in Japan. Although radiological technologists may require further education on appropriate CTDIvol and DLP usage, the DRLs 2015 greatly contributed to the reduction of the CT radiation dose used in Japan.
- 1 February 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1058) , 20150671
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Objectives:The aims of this study were to estimate the effective radiation doses from computed tomography (CT) examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses.Methods:A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest, and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software.Results:The mean effective doses for chest and abdominal examinations using 80–110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80–110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers (Siemens, Philips, and GE) were significantly lowe...
- 1 February 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1058) , 20150671
Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study
Objectives:The aims of this study were to estimate the effective radiation doses from computed tomography (CT) examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses.Methods:A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest, and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software.Results:The mean effective doses for chest and abdominal examinations using 80–110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80–110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers (Siemens, Philips, and GE) were significantly lowe...
- 1 August 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1052) , 20150219
Survey of volume CT dose index in Japan in 2014
The aims of this study are to propose a new set of Japanese diagnostic reference levels (DRLs) for 2014 and to study the impact of tube voltage and the type of reconstruction algorithm on patient doses. The volume CT dose index (CTDI(vol)) for adult and paediatric patients is assessed and compared with the results of a 2011 national survey and data from other countries. Scanning procedures for the head (non-helical and helical), chest and upper abdomen were examined for adults and 5-year-old children. A questionnaire concerning the following items was sent to 3000 facilities: tube voltage, use of reconstruction algorithms and displayed CTDI(vol). The mean CTDI(vol) values for paediatric examinations using voltages ranging from 80 to 100 kV were significantly lower than those for paediatric examinations using 120 kV. For adult examinations, the use of iterative reconstruction algorithms significantly reduced the mean CTDI(vol) values compared with the use of filtered back projection. Paediatric chest and abdominal scans showed slightly higher mean CTDI(vol) values in 2014 than in 2011. The proposed DRLs for adult head and abdominal scans were higher than those reported in other countries. The results imply that further optimization of CT examination protocols is required for adult head and abdominal scans as well as paediatric chest and abdominal scans. Low-tube-voltage CT may be useful for reducing radiation doses in paediatric patients. The mean CTDI(vol) values for paediatric scans showed little difference that could be attributed to the choice of reconstruction algorithm.
- 1 August 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1052) , 20150219
Survey of volume CT dose index in Japan in 2014
The aims of this study are to propose a new set of Japanese diagnostic reference levels (DRLs) for 2014 and to study the impact of tube voltage and the type of reconstruction algorithm on patient doses. The volume CT dose index (CTDI(vol)) for adult and paediatric patients is assessed and compared with the results of a 2011 national survey and data from other countries. Scanning procedures for the head (non-helical and helical), chest and upper abdomen were examined for adults and 5-year-old children. A questionnaire concerning the following items was sent to 3000 facilities: tube voltage, use of reconstruction algorithms and displayed CTDI(vol). The mean CTDI(vol) values for paediatric examinations using voltages ranging from 80 to 100 kV were significantly lower than those for paediatric examinations using 120 kV. For adult examinations, the use of iterative reconstruction algorithms significantly reduced the mean CTDI(vol) values compared with the use of filtered back projection. Paediatric chest and abdominal scans showed slightly higher mean CTDI(vol) values in 2014 than in 2011. The proposed DRLs for adult head and abdominal scans were higher than those reported in other countries. The results imply that further optimization of CT examination protocols is required for adult head and abdominal scans as well as paediatric chest and abdominal scans. Low-tube-voltage CT may be useful for reducing radiation doses in paediatric patients. The mean CTDI(vol) values for paediatric scans showed little difference that could be attributed to the choice of reconstruction algorithm.
- 1 September 1995
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 5 (3) , 237-242
Excimer laser induced CVD and its application to selective non-planar metallization
Ultraviolet laser induced selective chromium metallization of a non-planar microscopic surface is established. The chromium film deposited from the gas phase Cr(CO)6 precursor showed low electric conductivity because of impurities such as carbon oxygen produced as side-products of the photochemical reaction of the precursor. In order to obtain highly conductive metallization on non-planar surface, a two-step patterning method is studied. As the first step, conductive nickel film is formed around three-dimensional polyurethane substrates by using an electroless plating method. In the second step, chromium is selectively deposited on the nickel layer employing the UV laser induced CVD method. The nickel layer is then selectively etched using the chromium as a mask. The conductive nickel pattern is successfully achieved employing the two-step patterning method. As an application example of these new fabrication techniques, we propose a built-in tactile sensor at the probe-head of a catheter. A fabricated prototype of the tactile sensor is reported.
- 1 September 1995
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 5 (3) , 237-242
Excimer laser induced CVD and its application to selective non-planar metallization
Ultraviolet laser induced selective chromium metallization of a non-planar microscopic surface is established. The chromium film deposited from the gas phase Cr(CO)6 precursor showed low electric conductivity because of impurities such as carbon oxygen produced as side-products of the photochemical reaction of the precursor. In order to obtain highly conductive metallization on non-planar surface, a two-step patterning method is studied. As the first step, conductive nickel film is formed around three-dimensional polyurethane substrates by using an electroless plating method. In the second step, chromium is selectively deposited on the nickel layer employing the UV laser induced CVD method. The nickel layer is then selectively etched using the chromium as a mask. The conductive nickel pattern is successfully achieved employing the two-step patterning method. As an application example of these new fabrication techniques, we propose a built-in tactile sensor at the probe-head of a catheter. A fabricated prototype of the tactile sensor is reported.
- Open Access
- 1 January 1994
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 50 (8) , 1419
504. Evaluation of dual head gamma camera
- 1 January 1994
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 50 (8) , 1419
Open Access504. Evaluation of dual head gamma camera