MLMichael Lechner

Michael Lechner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Lechner has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • F. Mayer

    Department of Surgery, Paracelsus Medical University Salzburg, University Hospital Salzburg, Salzburg, Austria

    6 shared publications
  • K. Emmanuel

    Department of Surgery, Paracelsus Medical University, Salzburg, Austria

    5 shared publications
  • K. Borhanian

    Department of Surgery, Paracelsus Medical University, Salzburg, Austria

    3 shared publications
  • R. Bittner

    Department of Surgery, Paracelsus Medical University, Salzburg, Austria

    3 shared publications
  • S. Mitterwallner

    Department of Surgery, Paracelsus Medical University, Salzburg, Austria

    3 shared publications
  • F. Singhartinger

    Department of Surgery, Paracelsus Medical University, Salzburg, Austria

    2 shared publications

Latest Publications

  • Open Access

    Endoscopic vacuum therapy for Boerhaave’s syndrome—a single tertiary referral center retrospective cohort analysis with a treatment algorithm

    by Franz Singhartinger, Antonia Gantschnigg, Angela Wimmer, Patrick Rebnegger, Michael Lechner, Jaroslav Presl, Bernhard Wernly, Jörg Hutter, Charlotte Rabl, Oliver Koch, et al.

    Summary: Background: Boerhaave’s syndrome (BS) is a rare but often fatal condition with high mortality rates despite intensive treatment. Data are scarce. We herein report a single-center experience with BS. The aim of this study was to investigate and point out the role of endoluminal vacuum therapy (EVT) in BS. Methods: Between June 2011 and April 2024, all patients with BS in our tertiary referral center with a unit specialized in surgical endoscopy were analyzed regarding age, gender, delay of diagnosis, treatment technique, and outcome. Results: During the study period, 12 consecutive patients (9 male) were treated for BS. The median age was 64.8 years. Five patients were treated with EVT only, four with surgery and simultaneous EVT, and three by surgery only. After implementation of EVT, all patients were treated with either EVT only or surgery with simultaneous EVT. Intensive care unit stay was significantly shorter in patients treated with EVT only. The 30-day mortality was 25% (3 patients). No long-term complications occurred. Conclusion: This investigation led to our current strategy of applying only EVT in patients in a stable condition and no CT signs of vast pleural content. Otherwise, surgery plus EVT is performed.

  • Open Access

    Clip migration into the duodenum after laparoscopic oncological hemicolectomy—a case report

    by I. Dornauer, T. Jäger, P. Schredl, I. Mühlbacher, K. Rokitte, K. Emmanuel, J. Holzinger, F. Singhartinger, J. M. Kern, M. Lechner

    Summary: Clip migration is a rare but serious complication following laparoscopic procedures. Only isolated case reports of clip migration after colon resections have been published to date. We report a case of migration of a polymer vascular ligature clip into the duodenum in a 40-year-old, otherwise physically fit patient, who presented with acute abdomen 7 months after undergoing laparoscopic right hemicolectomy for cecal cancer. Intraoperatively a clip was found in the duodenal lumen associated with anastomotic stump insufficiency and fistula formation into the duodenum, confirmed by CT scan showing a chronically inflamed intraabdominal cavity resembling an abscess. Nine days after emergency surgery the patient was discharged home and is currently in oncological and clinical remission.

  • Open Access

    Is there a role for botulinum toxin in inguinal hernia surgery? Case report on the management of a giant scrotal hernia

    by C. Schmutzhart, F. Mayer, J. Grünfelder, K. Rokitte, I. Dornauer, P. Rebnegger, N. Schörghofer, F. Singhartinger, K. Emmanuel, M. Lechner

    Summary: The use of botulinum toxin A in the management of ventral hernias is a well-established method to potentially spare the patient a surgical component operation or a visceral resection during the repair of loss-of-domain hernias with the goal of reducing the intra-abdominal pressure and avoiding complications like ischemia as result of decreased organ perfusion. For very large inguinal hernias, this approach has not yet gained general acceptance as a treatment option. Standard procedures for inguinal hernia repair to date include Lichtenstein, TAPP/TEPP, or Shouldice procedures. Preconditioning of the abdominal wall with botulinum toxin is not currently part of the standard procedure for the management of inguinal hernias, since these are less frequently associated with loss of domain and, therefore, rarely demand surgical component separation or visceral resection for the reduction of herniated organs. We discuss the case of a 73-year-old patient who was presented to the clinic with a bilateral inguinal hernia. Since the left-sided hernia was a massive scrotal hernia with loss of domain, a staged approach to the repair was planned. We discuss the findings, management, and outcome of the treatment.

  • Open Access

    Stability of Bipolar Plate Materials for Proton‐Exchange Membrane Water Electrolyzers: Dissolution of Titanium and Stainless Steel in DI Water and Highly Diluted Acid

    by Lena Fiedler, Tien‐Ching Ma, Birk Fritsch, Jan H. Risse, Michael Lechner, Dominik Dworschak, Marion Merklein, Karl J. J. Mayrhofer, Andreas Hutzler

    The widespread use of proton exchange membrane water electrolyzers (PEMWE) is hindered by their high cost, of which a colossal factor is caused by the bipolar plates (BPP). In this paper, we investigate the stability of two BPP materials on‐line with an optimized scanning flow cell setup coupled to an inductively coupled plasma mass spectrometer (SFC‐ICP‐MS), as well as scanning electron microscopy (SEM). The stability of currently used titanium and a cheaper alternative, stainless steel (SS) 316L, were characterized in deionized (DI) water and 0.5 mM H2SO4 to mimic the conditions at the BPP under operation. We show that the dissolution of Ti is negligible, whereas SS 316L degrades notably. Here, besides pH, the applied potentials play a crucial role. Nonetheless, even for the highest measured dissolution rate of SS 316L, the contamination in a full cell is estimated to remain below 1 ppm. This work illustrates the capabilities of on‐line high‐throughput stability tests for BPP materials and could therefore contribute towards optimization of cost‐effective PEMWE.


  • Open Access

    Surgical and radiological behavior of MRI-depictable mesh implants after TAPP repair: the IRONMAN study

    by M. Lechner, M. Meissnitzer, K. Borhanian, R. Bittner, R. Kaufmann, F. Mayer, T. Jäger, S. Mitterwallner, K. Emmanuel, R. Forstner

    Purpose Knowledge of postoperative behavior of mesh implants used for hernia repair is generally limited to cases of recurrence, local complications or return to the previous operative field in other pathological conditions. Previous studies with MRI-visible mesh implants in different parts of the abdominal wall have led to variable findings with regard to mesh properties and mostly described a reduction in size over time with subsequently limited mesh overlap over hernia defects which could contribute to recurrence. We aimed to evaluate implant properties in a mechanically stable anatomical region after TAPP repair of primary unilateral inguinal hernias in men with clinical and MRI examinations 4 weeks and 1 year after surgery. Methods From 11/2015 to 01/2019, 23 men with primary, unilateral, inguinal hernias underwent TAPP repair with iron particle-loaded, MRI-visible mesh implants in a prospective cohort study. In 16 patients the operative outcome could be evaluated 4 weeks and 12 months after surgery by clinical examination and MRI evaluation with regard to postoperative course, possible adverse outcomes and radiological findings related to implant behavior—namely MRI-identifiability, mesh dislocation or reduction in surface area. Results All included patients had an uneventful postoperative clinical course. MRI after 4 weeks revealed one postoperative seroma, which resolved spontaneously. No recurrence was detected. Mesh implants could be accurately delineated in DIXON-IN studies and showed neither clinically nor statistically significant changes in size or position. Conclusion 4 weeks and 1 year after a standardized TAPP procedure the mesh implant used in this study showed no tendency towards dislocation or reduction in size in this anatomical position. Its MRI visibility allows accurate delineation during the postoperative course by experienced radiologists in appropriate MRI protocols. Larger patient series are desirable to further support these findings. Shrinkage of implants in the groin as a reason for early recurrence may be overestimated.


  • Open Access

    Is round ligament varicosity in pregnancy a common precursor for the later development of inguinal hernias? The prospective analysis of 28 patients over 9 years

    by M. Lechner, R. Bittner, K. Borhanian, S. Mitterwallner, K. Emmanuel, F. Mayer

    Purpose Short-term effects of round ligament varicosity (RLV) in pregnancy have been investigated in small-scale studies. The long-term effects are unknown. This study aims to evaluate the risk of groin hernia manifestation after RLV in pregnancy, to delineate possible risk factors and to analyze the natural course of pregnancy and post-partum period with regard to RLV. Methods In a prospective analysis 28 pregnant women with RLV presented to the hernia clinic over 9 years. After clinical and ultrasound examination during pregnancy and publication of early results in 2013 a second structured follow-up was conducted. Demographic data, hernia-specific risk factors, comorbidities, pregnancy and birth-related data as well as post-partum period were documented without loss of follow-up. In these women, all pregnancies that occurred, including the ones without RLV, were analyzed. Results Median follow-up was 68 months (11.4–104.9). Only one groin hernia was found. No risk factors could be identified. After uncomplicated childbirth complaints subsided spontaneously in all but one patient within 4 weeks. Recurrence rates in subsequent pregnancies are up to 89%. Conclusion Temporary RLV-induced dilation of the deep inguinal ring in pregnancy is not a common precursor for the development of inguinal hernias later in life. All findings support the theory that the hindrance of venous blood flow caused by the gravid uterus is an important contributing factor for RLV in pregnancy, which is self-limited but has a high risk of recurrence and is not an indication for surgery before or after delivery or for cesarean section.


  • Open Access

    Retroperitoneal Liposarcoma: A Concern in Inguinal Hernia Repair

    by M. Lechner, K. Borhanian, S. Mitterwallner, R. Bittner, E. Klieser, G. Köhler, K. Emmanuel, F. Mayer

    The goal of the study was to evaluate retroperitoneal sarcomas with continuous growth into the scrotum through the inguinal canal with regard to diagnostic approach, surgical treatment, and outcome. The analysis is based on a comprehensively documented ...


  • Open Access

    Is the age of >65 years a risk factor for endoscopic treatment of primary inguinal hernia? Analysis of 24,571 patients from the Herniamed Registry

    by F. Mayer, M. Lechner, D. Adolf, D. Öfner, G. Köhler, R. Fortelny, R. Bittner, F. Köckerling

    Several analyses of hernia registries have demonstrated that patients older than 65 years have significantly higher perioperative complication rates compared with patients up to the age of 65. To date, no special analyses of endoscopic/laparoscopic inguinal hernia surgery or of the relevant additional influence factors have been carried out. Besides, there is no definition to determine whether 65 years should really be considered to be the age limit. In the Herniamed Hernia Registry, it was possible to identify 24,571 patients with a primary inguinal hernia and aged at least 16 years who had been operated on between September 1, 2009, and April 15, 2013, using either the TAPP technique (n = 17,214) or TEP technique (n = 7,357). Patients in the age group up to and including 65 years (≤65 years) were compared with those older than 65 years (>65 years) in terms of their perioperative outcome. That was done first using unadjusted analysis and then multivariable analysis. Unadjusted analysis revealed significantly different results for the intraoperative (1.19 vs 1.60%; p = 0,010), postoperative surgical (2.72 vs 4.59%; p < 0.001) and postoperative general complications (0.85 vs 1.98%; p < 0.001) as well as for complication-related reoperations (1.07 vs 1.37%; p = 0,044), which were more favorable in the ≤65 years age group. However, in multivariable analysis, it was not possible to confirm that for the intraoperative complications or the reoperations. Reoperations were needed more often for bilateral procedures (p < 0.001; OR 2.154 [1.699; 2.730]), higher ASA classification (IV vs I: p = 0.004; OR 6.001 [1.786; 20.167]), larger hernia defect and scrotal hernias. The impact of these factors, in addition to that of age >65 years, was also reflected in the postoperative complication rates. The age limit for increased onset of perioperative complication rates tends to be more than 80 rather than 65 years. The higher perioperative complication rate associated with endoscopic/laparoscopic inguinal hernia surgery in patients older than 65 years is of multifactorial genesis and is observed in particular as from the age of 80 years.


  • Suspected inguinal hernias in pregnancy—handle with care!

    by M. Lechner, R. Fortelny, D. Öfner, F. Mayer

    With a newly described diagnostic pathway, we aim to avoid unnecessary surgical exploration for suspected symptomatic groin hernias in pregnancy.