Emma R. Biglin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emma R. Biglin has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Amy L. Chadwick
Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
2 shared publications - Gareth Price
Department of Radiotherapy Related Research, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
2 shared publications Adam H Aitkenhead
The Christie NHS Foundation Trust, Wilmslow Road, Manchester, M20 4BX, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publicationAdam H. Aitkenhead
Division of Cancer Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, 3rd floor Proton Beam Therapy Centre, Manchester, UK
1 shared publication- Adam H. Aitkenhead
Christie Medical Physics and Engineering, The Christie NHS Foundation Trust , Manchester , UK
1 shared publication - Alan McWilliam
Division of Cancer Sciences, University of Manchester, Manchester, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 29 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 037004
A survey of dosimetry quality assurance practice at UK small animal radiation research platform (SARRP) facilities
Introduction: Improvements in preclinical radiation research have been made to better mimic the equipment and techniques implemented in the clinic. The development of dedicated small animal radiation units facilitates such advances by combining treatment planning, image guidance and conformal delivery. One area significantly behind its clinical equivalent are standardised dosimetry quality assurance (QA) protocols, hampering the translatability of results into the development of clinical interventions. Approach: The aim of the study described herein was to summarise the current QA procedures implemented at several institutions on Small Animal Radiation Research Platforms (SARRPs), the system used by the six institutions surveyed, and to determine the barriers to implementing a standard dosimetry protocol. Participants at UK research institutions were invited to complete a questionnaire to ascertain their current preclinical QA practice. Main results: All participants involved undertake regular dose output measurements and most perform image guidance QA measurements. Consistency in QA procedures differed when more complex plan verification or end-to-end testing was discussed. Significance: This survey demonstrates that, although improvements are being made in the awareness of the importance of regular dosimetry tests, there is still a way to go to standardise the procedures with regards to more complex verifications. Incorporating robust QA procedures and strict dose constraints would ensure the reliability and ethical integrity of experiments involving small animals. This approach not only protects the welfare of the animals but also enhances the quality and reproducibility of the preclinical results.
- 29 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 037004
Open AccessA survey of dosimetry quality assurance practice at UK small animal radiation research platform (SARRP) facilities
Introduction: Improvements in preclinical radiation research have been made to better mimic the equipment and techniques implemented in the clinic. The development of dedicated small animal radiation units facilitates such advances by combining treatment planning, image guidance and conformal delivery. One area significantly behind its clinical equivalent are standardised dosimetry quality assurance (QA) protocols, hampering the translatability of results into the development of clinical interventions. Approach: The aim of the study described herein was to summarise the current QA procedures implemented at several institutions on Small Animal Radiation Research Platforms (SARRPs), the system used by the six institutions surveyed, and to determine the barriers to implementing a standard dosimetry protocol. Participants at UK research institutions were invited to complete a questionnaire to ascertain their current preclinical QA practice. Main results: All participants involved undertake regular dose output measurements and most perform image guidance QA measurements. Consistency in QA procedures differed when more complex plan verification or end-to-end testing was discussed. Significance: This survey demonstrates that, although improvements are being made in the awareness of the importance of regular dosimetry tests, there is still a way to go to standardise the procedures with regards to more complex verifications. Incorporating robust QA procedures and strict dose constraints would ensure the reliability and ethical integrity of experiments involving small animals. This approach not only protects the welfare of the animals but also enhances the quality and reproducibility of the preclinical results.
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e723-e724
Validation of Hypoxia Detection Sequences on the MR Linac
- 29 September 2023
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 117 (2) , e723-e724
Validation of Hypoxia Detection Sequences on the MR Linac
- Open Access
- 26 April 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
A preclinical radiotherapy dosimetry audit using a realistic 3D printed murine phantom
Preclinical radiation research lacks standardized dosimetry procedures that provide traceability to a primary standard. Consequently, ensuring accuracy and reproducibility between studies is challenging. Using 3D printed murine phantoms we undertook a dosimetry audit of Xstrahl Small Animal Radiation Research Platforms (SARRPs) installed at 7 UK centres. The geometrically realistic phantom accommodated alanine pellets and Gafchromic EBT3 film for simultaneous measurement of the dose delivered and the dose distribution within a 2D plane, respectively. Two irradiation scenarios were developed: (1) a 10 × 10 mm2 static field targeting the pelvis, and (2) a 5 × 5 mm2 90° arc targeting the brain. For static fields, the absolute difference between the planned dose and alanine measurement across all centres was 4.1 ± 4.3% (mean ± standard deviation), with an overall range of − 2.3 to 10.5%. For arc fields, the difference was − 1.2% ± 6.1%, with a range of − 13.1 to 7.7%. EBT3 dose measurements were greater than alanine by 2.0 ± 2.5% and 3.5 ± 6.0% (mean ± standard deviation) for the static and arc fields, respectively. 2D dose distributions showed discrepancies to the planned dose at the field edges. The audit demonstrates that further work on preclinical radiotherapy quality assurance processes is merited.
- 26 April 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Open AccessA preclinical radiotherapy dosimetry audit using a realistic 3D printed murine phantom
Preclinical radiation research lacks standardized dosimetry procedures that provide traceability to a primary standard. Consequently, ensuring accuracy and reproducibility between studies is challenging. Using 3D printed murine phantoms we undertook a dosimetry audit of Xstrahl Small Animal Radiation Research Platforms (SARRPs) installed at 7 UK centres. The geometrically realistic phantom accommodated alanine pellets and Gafchromic EBT3 film for simultaneous measurement of the dose delivered and the dose distribution within a 2D plane, respectively. Two irradiation scenarios were developed: (1) a 10 × 10 mm2 static field targeting the pelvis, and (2) a 5 × 5 mm2 90° arc targeting the brain. For static fields, the absolute difference between the planned dose and alanine measurement across all centres was 4.1 ± 4.3% (mean ± standard deviation), with an overall range of − 2.3 to 10.5%. For arc fields, the difference was − 1.2% ± 6.1%, with a range of − 13.1 to 7.7%. EBT3 dose measurements were greater than alanine by 2.0 ± 2.5% and 3.5 ± 6.0% (mean ± standard deviation) for the static and arc fields, respectively. 2D dose distributions showed discrepancies to the planned dose at the field edges. The audit demonstrates that further work on preclinical radiotherapy quality assurance processes is merited.
- Open Access
- 31 July 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
Preclinical dosimetry: exploring the use of small animal phantoms
Preclinical radiotherapy studies using small animals are an indispensable step in the pathway from in vitro experiments to clinical implementation. As radiotherapy techniques advance in the clinic, it is important that preclinical models evolve to keep in line with these developments. The use of orthotopic tumour sites, the development of tissue-equivalent mice phantoms and the recent introduction of image-guided small animal radiation research platforms has enabled similar precision treatments to be delivered in the laboratory. These technological developments, however, are hindered by a lack of corresponding dosimetry standards and poor reporting of methodologies. Without robust and well documented preclinical radiotherapy quality assurance processes, it is not possible to ensure the accuracy and repeatability of dose measurements between laboratories. As a consequence current RT-based preclinical models are at risk of becoming irrelevant. In this review we explore current standardization initiatives, focusing in particular on recent developments in small animal irradiation equipment, 3D printing technology to create customisable tissue-equivalent dosimetry phantoms and combining these phantoms with commonly used detectors.
- 31 July 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
Open AccessPreclinical dosimetry: exploring the use of small animal phantoms
Preclinical radiotherapy studies using small animals are an indispensable step in the pathway from in vitro experiments to clinical implementation. As radiotherapy techniques advance in the clinic, it is important that preclinical models evolve to keep in line with these developments. The use of orthotopic tumour sites, the development of tissue-equivalent mice phantoms and the recent introduction of image-guided small animal radiation research platforms has enabled similar precision treatments to be delivered in the laboratory. These technological developments, however, are hindered by a lack of corresponding dosimetry standards and poor reporting of methodologies. Without robust and well documented preclinical radiotherapy quality assurance processes, it is not possible to ensure the accuracy and repeatability of dose measurements between laboratories. As a consequence current RT-based preclinical models are at risk of becoming irrelevant. In this review we explore current standardization initiatives, focusing in particular on recent developments in small animal irradiation equipment, 3D printing technology to create customisable tissue-equivalent dosimetry phantoms and combining these phantoms with commonly used detectors.